• Title/Summary/Keyword: Biomedical Engineering convergence

Search Result 401, Processing Time 0.025 seconds

Cultural Implications of Moving into the World - Focusing On section of 『Samkukyousa』 (세상으로 나아가기의 문화적 의미 - 『삼국유사』 <피은>편을 중심으로)

  • Kim, Kyung-Seop;Kim, Jeong-Lae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.333-339
    • /
    • 2022
  • Finding traces of the numerous contexts that exist in our culture surrounding an old-narrative and leading to it's textualization provides a chance to read the story anew. The 'Pieun(避隱)' section of 'Samgukyusa' contains the stories of people who hide from the world and avoid it, as well as the different types of stories by the compiler, the Buddihist monk, Ilyeon. In other words, the compiler has textualized the story. This study aims to attentively analyze the specific story in the 'Pieun' section and read the insights of the compiler on whether to move into the world or hide from the world. Through this analysis, it is apparent that the episode of 'Pieun' does not only illustrate the characters who wish to escape or hide from the world, but it also enables readers to grasp the intention of Ilyeon who deliberately includes the banquet story which is contrary to the meaning of the title. In the 'Pieun', he emphasizes that the behavior of revealing and hiding oneself to and from the world has significant religious and cultural meanings for an individual. The writer, without distinguishing people who move into the world or hide from it, used the Buddhist Dialectictics method to present a different interpretation.

Cell-cultivable ultrasonic transducer integrated on glass-coverslip (세포 배양 가능한 커버슬립형 초음파 변환자)

  • Keunhyung Lee;Jinhyoung Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.412-421
    • /
    • 2023
  • Ultrasound brain stimulation is spot-lighted by its capability of inducing brain cell activation in a localized deep brain region and ultimately treating impaired brain function while the efficiency and directivity of neural modulation are highly dependent on types of stimulus waveforms. Therefore, to optimize the types of stimulation parameters, we propose a cell-cultivable ultrasonic transducer having a series stack of a spin-coated polymer piezoelectric element (Poly-vinylidene fluoride-trifluorethylene, PVDF-TrFE) and a parylene insulating layer enhancing output acoustic pressure on a glass-coverslip which is commonly used in culturing cells. Due to the uniformity and high accuracy of stimulus waveform, tens of neuronal cell responses located on the transducer surface can be recorded simultaneously with fluorescence microscopy. By averaging the cell response traces from tens of cells, small changes to the low intensity ultrasound stimulations can be identified. In addition, the reduction of stimulus distortions made by standing wave generated from reflections between the transducers and other strong reflectors can be achieved by placing acoustic absorbers. Through the proposed ultrasound transducer, we could successfully observe the calcium responses induced by low-intensity ultrasound stimulation of 6 MHz, 0.2 MPa in astrocytes cultured on the transducer surface.

A Study on the Measurement of Respiratory Rate Using Image Alignment and Statistical Pattern Classification (영상 정합 및 통계학적 패턴 분류를 이용한 호흡률 측정에 관한 연구)

  • Moon, Sujin;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.10
    • /
    • pp.63-70
    • /
    • 2018
  • Biomedical signal measurement technology using images has been developed, and researches on respiration signal measurement technology for maintaining life have been continuously carried out. The existing technology measured respiratory signals through a thermal imaging camera that measures heat emitted from a person's body. In addition, research was conducted to measure respiration rate by analyzing human chest movement in real time. However, the image processing using the infrared thermal image may be difficult to detect the respiratory organ due to the external environmental factors (temperature change, noise, etc.), and thus the accuracy of the measurement of the respiration rate is low.In this study, the images were acquired using visible light and infrared thermal camera to enhance the area of the respiratory tract. Then, based on the two images, features of the respiratory tract region are extracted through processes such as face recognition and image matching. The pattern of the respiratory signal is classified through the k-nearest neighbor classifier, which is one of the statistical classification methods. The respiration rate was calculated according to the characteristics of the classified patterns and the possibility of breathing rate measurement was verified by analyzing the measured respiration rate with the actual respiration rate.

A parallel plate viscometer for blood viscosity measurement (혈액점도 측정용 평행판 점도계)

  • Donggil Seo;Kyung Hyun Ahn;Jihoon Kang;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.331-335
    • /
    • 2023
  • As the viscosity of the blood increases, the blood becomes more sticky and difficult to flow, so the possibility of thrombosis increases and the probability of ischemic cerebral infarction increases. The importance of measuring blood viscosity has recently been emphasized for the prevention of circulatory system diseases, and the need for a viscometer capable of easily and accurately measuring blood viscosity has emerged. In this study, the measured values of a viscosity standard solution and an artificial blood by a parallel-plate viscometer ARS-Medi were compared with the those by Ares-G2 of TA instrument, which is internationally recognized for its accuracy and reliability. The viscosity of N44 standard solution, which is a Newtonian solution, was almost perfectly matched between the two instruments at all shear rates. In the case of an artificial blood, which is a non-Newtonian solution, the measured values between the two instruments showed a difference of about 10% at the lowest shear rate 1 rad/s; however, at a clinically significant shear rate of 10 rad/s or higher, the measured values between them were consistent within the error range. We expect that ARS-Medi, a newly developed parallel-plate viscometer for blood, using disposable plates, will be very useful in clinical practice as it improves the convenience and hygiene of blood viscosity measurement.

Regulations on Wheelchair Power Assist Add-ons in Korea, Europe and United States (한국, 미국, 유럽의 휠체어동력보조장치 규제 현황)

  • Ki-Won Choi;Suk-Min Lee;Inhyuk Moon;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.2
    • /
    • pp.525-531
    • /
    • 2023
  • In Korea, which is entering a super-aged society, the number of elderly patients who have difficulty walking independently is expected to increase rapidly, and it is necessary to develop wheelchair products with various functions to improve the quality of life of people with walking disabilities. Recently, wheelchair power assist devices that provide propulsion power by being attached to a manual wheelchair has been developed and is entering the domestic and global markets. In this study, we compared and analyzed the process of obtaining medical device certification for wheelchair power assist devices in Korea, the United States, and Europe. In Korea, a Class 2 medical device certification process was developed in 2021, and in the US FDA, it corresponds to Class 2 like the existing electric wheelchair and must pass the 510k certification process. In the case of Europe, it is uniquely regulated as Class I, and the CE mark can be attached through a relatively easy self-declaration of conformity. The Korean medical device industry, which is struggling with MDR certification, a new European medical device regulation, should pay attention to the relatively easy entry into the global market for wheelchair power assist products.

Literary Significance and Cultural Character of 'Personal Narrative' ('체험이야기'의 문학적 의의와 문화적 성격)

  • Kyung-Seop Kim;Jeong-Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.133-140
    • /
    • 2023
  • The origin of texts we refer to as literary or artistic may be imagination, but many are based on experiences. In fact, experiences can be the source of artistic imagination since imagination often builds upon experiences. Therefore, the act of verbalizing human experiences using them as raw material can become a great form of art. Transforming past experiences into stories and infusing them with vitality inevitably requires a creative process of reconstruction, which is essentially a literary process. As such, 'Personal Narrative' holds significance as a literary process that weaves facts into stories and shapes them into forms. Individual experiences are stored as personal memories, and these 'personal memories' continuously generate stories. Collections of individual stories are stored as multiple memories, which gradually form 'collective memories' with distinct social and cultural inclinations through the passage of time and invisible yet potent societal and cultural censorship. The problem lies in the fact that individuals may tend to align their own memories with the inclinations of collective memory rather than simply recalling what they personally experienced. In the context of actual history, personal memories and collective memories communicate with each other, producing non-fictional content close to reality and sometimes manifesting as fiction content enriched with imagination. 'Personal Narrative' holds a significant genre as one genre of non-fiction content within our culture.

Imaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm (가상의 단일 에너지 영상 재구성 기법을 이용한 하지 단층촬영 혈관조영술에서 말초 동맥 질환 영상 소견)

  • Jun Seong Kim;So Hyun Park;Suyoung Park;Jung Han Hwang;Jeong Ho Kim;Seong Yong Pak;Kihyun Lee;Bernhard Schmidt
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1032-1045
    • /
    • 2022
  • Peripheral arterial disease (PAD) is common in elderly patients. Lower-extremity CT angiography (LE-CTA) can be useful for detecting PAD and planning its treatment. PAD can also be accurately evaluated on reconstructed monoenergetic images (MEIs) from low kiloelectron volt (keV) to high keV images using dual-energy CT. Low keV images generally provide higher contrast than high keV images but also feature more severe image noise. The noise-reduced virtual MEI reconstruction algorithm, called the Mono+ technique, was recently introduced to overcome such image noise. Therefore, this pictorial review aimed to present the imaging findings of PAD on LE-CTA and compare low and high keV images with those subjected to the Mono+ technique. We found that, in many cases, the overall and segmental image qualities were better and metal artifacts and venous contamination were decreased in the high keV images.

Development of a hip model for impact testing of bedsore prevention cushions (욕창예방 방석의 충격시험용 둔부 모형 개발)

  • JUNG, SUNGBAE;YUK, SUNWOO;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.7-11
    • /
    • 2024
  • The bedsore prevention cushion serves to prevent the skin on the buttocks of a wheelchair user from being damaged through friction with the wheelchair seat. This is because it absorbs some of the weight applied to the wheelchair seat and allows the weight to be applied evenly to the entire contact surface. For the impact test, which is part of the performance testing of bedsore prevention cushions, a hip model that represents the sitting posture of a wheelchair user is required. In this study, a hip model was manufactured for impact testing of bedsore prevention cushions for wheelchairs. Performance tests for pressure bedsore prevention cushions for wheelchairs include KSP 0236, a Korean standard, and KS P ISO 16840-2, an ISO international standard. The hip model proposed in KS P ISO 16840-2 was more suitable for impact testing of bedsore prevention cushions for wheelchairs. However, the guidelines for making hip models proposed by international standards need to be modified to reflect the advancement of model making technology and use easier methods. We propose a new hip model production method that produces a hip model out of plastic all at once and additionally attaches SS-41 steel plates processed into the shape of the hip to make the mass of the model similar to the human body.

Analyze dosimetry with and without shielding when amplifying scattered rays (산란선 증폭시 차폐체 유무에 따른 선량 분석)

  • Chang Ho Cho;Jeong Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.819-825
    • /
    • 2024
  • The reason for recording dose data when using a diagnostic radiation source is to record and manage the dose to healthcare personnel and patients. The purpose of this study was to verify the difference in radiation dose when using diagnostic radiation generating devices and to inform users' awareness of dose reduction through measurement and analysis of dose in situations with and without shielding. The dose analysis of each equipment for two Korean C-arms and two German C-arms showed that the Korean FPD type C-arm had the highest dose value, followed by the German I.I type C-arm, German FPD type C-arm, Korean, and I.I type C-arm. The results of the dose analysis with and without shielding showed that the dose to the human phantom in a normal atmosphere increased by about 2 times due to scattered radiation, but the dose to the human phantom was reduced by about 5 times by wearing a shield (0.5mm/lead apron). More important than the management of radiation dose is the study of how to reduce exposure when using radiation, and since the radiation dose output from different equipment is different, it is necessary to provide dose information with and without shielding.

EVA Sheet and Butyl Rubber based Waterproofing·Anti-Corrosion Sheet for Corrosion Maintenance and Repairing in the Interior Side of the Large Steel Pipes in Water Treatment Facilities (상수도용 대구경 녹 발생 강관 내부의 보수 및 성능 유지를 위한 EVA 시트와 부틸고무를 합지한 자착식 방수방식 시트의 부착성능 평가)

  • An, Ki-Won;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.267-274
    • /
    • 2017
  • This study discusses the applicability of environmental friendly EVA based butyl rubber self-adhesive waterproof sheet designed to prevent corrosion of large scale pipes used in the water treatment facilities during th water treatment process. The experiments conducted tested the waterproofing sheet's adhesion strength on the steel surface of the pipes and checked for whether the material has the proper response properties against the various environmental conditions. In addition, it the sheet adhered to the steel pipe was to see if the adhesion hold against the water pressure due to the ingress of inflow water. Finally, the waterproofing sheet's adhesion strength was tested on a rusted steel surface to confirm whether the material has the necessary properties to secure stable adhesion strength and prevent corrosion of steel pipes at the same time during the process of installation or maintenance. As a result, the self-adhesive waterproof sheets showed that all attachments in the untreated, long term pressuring, immersion in chemical substance (hydrochloric acid, hypochlorous acid, sodium hydroxide), low temperature ($-20^{\circ}C$) conditions showed a adhesion performance of higher than 1.5N/mm, which is the performance standard of KS F 4934. Also, in the testing to check for the adhesion property against inverse water pressure, it was observed that the adhesion failure did not occur even up to $3.0N/mm^2$ pressure. Also, in the process of assessing the adhesion performance on rusted steel surface, specimens after 12 hours of corrosion treatment was shown to have 2.1N/mm, and specimens after 168 hours of corrosion treatment was shown to have 2.0N/mm adhesion strength performance.