• Title/Summary/Keyword: Biomechanical analysis

Search Result 478, Processing Time 0.024 seconds

Application of the Chaos Theory to Gait Analysis (카오스 이론을 적용한 보행분석 연구)

  • Park, Ki-Bong;Ko, Jae-Hun;Moon, Byung-Young;Suh, Jeung-Tak;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.194-201
    • /
    • 2006
  • Gait analysis is essential to identify accurate cause and knee condition from patients who display abnormal walking. Traditional linear tools can, however, mask the true structure of motor variability, since biomechanical data from a few strides during the gait have limitation to understanding the system. Therefore, it is necessary to propose a more precise dynamic method. The chaos analysis, a nonlinear technique, focuses on understand how variations in the gait pattern change over time. Eight healthy eight subjects walked on a treadmill for 100 seconds at 60 Hz. Three dimensional walking kinematic data were obtained using two cameras and KWON3D motion analyzer. The largest Lyapunov exponent from the measured knee angular displacement time series was calculated to quantify local stability. This study quantified the variability present in time series generated from gait parameter via chaos analysis. Knee flexion-extension patterns were found to be chaotic. The proposed Lyapunov exponent can be used in rehabilitation and diagnosis of recoverable patients.

A Study on Kinetic Gait Analysis of the Normal Adult (정상 성인의 운동역학적 보행분석)

  • Kim, Geon;Yoon, Na-Mi
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.87-95
    • /
    • 2009
  • Purpose: This study reports the basic reference data of the specific gait parameters for Korean normal adults. Methods: The basic gait parameters were extracted from 73 Adults (35 men and 38 women), 18 to 33 years of age, using a Vicon MX motion analysis system. The segment kinetics, such as joint moment and power, was analyzed at the hip, knee and ankle. Results: The motion patterns are typically associated with a specific phase of the gait cycle. The temporal-spatial gait parameters of Korean normal adults, such as cadence, walking speed, stride length, single support and double support, were similar to the other western reference data. The kinetic parameters of Korean normal adults, such as joint moments of force, joint mechanical power generation or absorption and ground reaction forces, were also similar to other western reference datasets. Conclusion: This study demonstrates that objective gait analysis can be used to document the gait patterns of normal healthy adults. The techniques of 3-dimensional temporal-spatial gait parameters and kinematic parameters analysis can provide a detailed biomechanical description of a normal and pathological gait.

  • PDF

Analysis on Relation between Rehabilitation Training Movement and Muscle Activation using Weighted Association Rule Discovery (가중연관규칙 탐사를 이용한 재활훈련운동과 근육 활성의 연관성 분석)

  • Lee, Ah-Reum;Piao, Youn-Jun;Kwon, Tae-Kyu;Kim, Jung-Ja
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.6
    • /
    • pp.7-17
    • /
    • 2009
  • The precise analysis of exercise data for designing an effective rehabilitation system is very important as a feedback for planing the next exercising step. Many subjective and reliable research outcomes that were obtained by analysis and evaluation for the human motor ability by various methods of biomechanical experiments have been introduced. Most of them include quantitative analysis based on basic statistical methods, which are not practical enough for application to real clinical problems. In this situation, data mining technology can be a promising approach for clinical decision support system by discovering meaningful hidden rules and patterns from large volume of data obtained from the problem domain. In this research, in order to find relational rules between posture training type and muscle activation pattern, we investigated an application of the WAR(Weishted Association Rule) to the biomechanical data obtained mainly for evaluation of postural control ability. The discovered rules can be used as a quantitative prior knowledge for expert's decision making for rehabilitation plan. The discovered rules can be used as a more qualitative and useful priori knowledge for the rehabilitation and clinical expert's decision-making, and as a index for planning an optimal rehabilitation exercise model for a patient.

The Biomechanical Correlation Analysis of Upper Body according to Forward Head Posture (머리전방자세에 따른 상체의 생체역학적 상관분석)

  • Jung, Yeon-Woo;Gong, Won-Tae;Kwon, Hyeok-Soo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.1-9
    • /
    • 2013
  • Background: The purpose of this study is to analysis of correlation upper body according to forward head posture. Methods: The subjects of this study were 40 female university students who were equally and randomly allocated to a forward head posture group, normal group. Using general posture system, electromyograph, visual analogue scale, tape measurement, neck disability index were evaluated. Results: There was positive correlation between posture analysis and Sternocleidomastoid, neck flexion (p<.05). There was positive correlation between Craniovertebral angle (CVA) and trapezius upper, VAS (p<.05). There was negative correlation between posture analysis and CVA (p<.05). There was negative correlation between Cranial rotation angle and CVA (p<.05). Conclusion: Increased forward head posture lead to increase of pain, muscles activity, so it suggests to be necessary on the prevention of dysfunction and limited activities daily living.

  • PDF

Design Optimization of UMPC Keypad Using Human Finger (인체 손가락 해석을 통한 UMPC 키패드 설계 최적화)

  • Park, Soo-Hyun;Kim, Kwang-Il;Yang, Tae-Seung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.544-547
    • /
    • 2008
  • As the mobile electronic product is getting slimmer and smaller, the necessity of keypad is being increased. But the possibility of mis-typing keypad is increased rapidly due to the integrated keypad in the small mobile product. The business division has not considered the methodology of keypad design essentially. In this paper, analysis method and design evaluation standard to reduce the mis-typing of UMPC(Ultra Mobile Personal Computer) is suggested. First, the finite element analysis model and the biomechanical human body model are implemented in order to simulate the exact contact characteristic between finger and keypad. The reliability of analysis model is guaranteed by the comparison of the contact pressure between analysis result and experiment result of the pressure sensor. The design optimization of key shape and layout is derived through the response surface method. The prototype model is produced with the optimized design of keypad, and then it verified the advanced function with user mis-typing detection test. The optimized keypad design reduced the mis-typing ratio from 35% of existing model to 75 of proposed model. If this paper is widely applied to not only UMPC but also the other electronic products, the emotional quality of all products could be improved considerably.

  • PDF

Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type

  • Ha, Seung-Ryong
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.475-483
    • /
    • 2015
  • PURPOSE. The objective of this study was to evaluate the influence of various cement types on the stress distribution in monolithic zirconia crowns under maximum bite force using the finite element analysis. MATERIALS AND METHODS. The models of the prepared #46 crown (deep chamfer margin) were scanned and solid models composed of the monolithic zirconia crown, cement layer, and prepared tooth were produced using the computer-aided design technology and were subsequently translated into 3-dimensional finite element models. Four models were prepared according to different cement types (zinc phosphate, polycarboxylate, glass ionomer, and resin). A load of 700 N was applied vertically on the crowns (8 loading points). Maximum principal stress was determined. RESULTS. Zinc phosphate cement had a greater stress concentration in the cement layer, while polycarboxylate cement had a greater stress concentration on the distal surface of the monolithic zirconia crown and abutment tooth. Resin cement and glass ionomer cement showed similar patterns, but resin cement showed a lower stress distribution on the lingual and mesial surface of the cement layer. CONCLUSION. The test results indicate that the use of different luting agents that have various elastic moduli has an impact on the stress distribution of the monolithic zirconia crowns, cement layers, and abutment tooth. Resin cement is recommended for the luting agent of the monolithic zirconia crowns.

Biomechanical Analysis of Human Stability According to Running Speed: A Comparative Analysis of Lyapunov Exponent and Coefficient of Variation Methods (달리기 속도에 따른 인체 안정성의 생체역학적 분석: 리아프노프 지수와 변이계수 방법의 비교 분석)

  • Ho-Jong Gil
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.34-44
    • /
    • 2023
  • Objective: The purpose of this study was to examine the effects of increasing running speed on human stability by comparing the Lyapunov Exponent (LyE) and Coefficient of Variation (CV) methods, with the goal of identifying key variables and uncovering new insights. Method: Fourteen adult males (age: 24.7 ± 6.4 yrs, height: 176.9 ± 4.6 cm, weight: 74.7 ± 10.9 kg) participated in this study. Results: In the CV method, significant differences were observed in ankle (flexion-inversion/eversion; p < .05) and hip joint (internal-external rotation; p < .05) movements, while the center of mass (COM) variable in the coronal axis movements showed a significant difference at the p < .001 level. In the LyE method, statistical differences were observed at the p < .05 level in knee (flexion-extension), hip joint (internal-external rotation) movements, and COM across all three directions (sagittal, coronal, and transverse axis). Conclusion: Our results revealed that the stability of the human body is affected at faster running speeds. The movement of the COM and ankle joint were identified as the most critical factors influencing stability. This suggests that LyE, a nonlinear time series analysis, should be actively introduced to better understand human stabilization strategies.

Evaluation for Biomechanical Effects of Metatarsal Pad and Insole on Gait (보행 중 중족골 패드와 인솔의 생체역학적 영향성 평가)

  • Choi, Jung-Kyu;Park, In-Sik;Lee, Hong-Jae;Won, Yong-Gwan;Kim, Jung-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.487-494
    • /
    • 2011
  • The purpose of this study was to evaluate the effects of metatarsal pad (MP) compared with barefoot and MP with using different insoles on gait. 15 healthy females who had no history of injury in the lower extremity with an average age of 22.7 year(SD=1.35), height of 160 cm(SD=3.4), weight of 48.8 kg(SD=5.52) and average foot size of 232.5 mm(SD=6.8) participated in this study as the subjects. The subjects walked on a treadmill under four different experimental conditions: 1) walking with barefoot, 2) walking wearing MP 3) walking wearing a soft insole with MP(SIMP), 4) walking wearing a rigid insole with MP(HIMP). During walking, foot pressure data such as force, contacting area, peak pressure, and mean pressure was collected using Pedar-X System(Novel Gmbh, Germany) and EMG activity of lower limb muscles such as tibialis anterior(TA), lateral gastrocnemius(LG), rectus femoris(RF), and musculus biceps femoris(MBF) was gathered using Delsys EMG Work System(Delsys, USA). Collected data was then analyzed using paired t-test in order to investigate the effects of each of experimental conditions. As a result of the analysis, when MP and HIMP were equipped, overall contacting area was increased while the force, peak pressure and the mean pressure were decreased. Especially, when the SIMP was equipped, every data were significantly decreased. In case of EMG, wearing MP, SIMP and HIMP made three muscles(TA, LG, RF)'s activity decrease. A result of the analysis will be able to apply for manufacturing functional shoes, diabetes shoes, senior shoes and lower extremity orthosis. Significance of the study due to a metatarsal pad and the insole is to analyze the changes in muscle strength.

Analysis of Plantar Foot Pressure according to Insole Types during Treadmill Gait (트레드밀 보행시 인솔 형태 변화에 따른 족저압력 분석)

  • Woo, Jung-Hwi;Lee, Joong-Sook;Yang, Jeong-Ok;Lee, Bom-Jin;Bae, Kang-Ho;Han, Dong-Wook;Park, Sang-Muk;Bae, Jin-Woo
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.113-122
    • /
    • 2015
  • Objective : The purpose of this study was to analyze the foot-pressure distribution of 2D(2 dimensional form) & 3D(3 dimensional form; a customized arch-fit for posture correction) insoles for assessing their biomechanical functionality. Background : Recently there has been increased interest in both foot health and foot pain patients. Analysis of the plantar pressure was often used to solve the problems of the foot displayed by such people as rheumatoid arthritis patients. Method : Subjects who participated in this study were 17 female university students who had no previous injury experience in lower limbs and a normal gait pattern. The shoe size of all subjects was 240 mm. Two models of insoles of 2D(typical flat insole - 2 dimensional form) and 3D(special production - 3 dimensional form) were selected for the test. Using the Pedar-X system and Pedar-X insoles, 4.0 km/h of walking speed, and a compilation of 50 steps walking stages were used to analyze foot-pressure distribution. Results : Results of the foot-pressure distribution and biomechanical functionality on each insole were as follows; analyses of mean plantar pressure, maximum plantar pressure, maximum vertical GRF, and plantar pressure curve shape all showed overall low plantar pressure and GRF. Conclusion : This can be evaluated as an excellent insole for low levels on the plantar pressure and GRF. Therefore, it is possible to conclude that according to this analysis the 3D Customized Arch-fit Insole was better than 2D insole on the basis of these criteria.

Evaluation of Biomechanical Properties of Fractured Adjacent Soft Tissue Due to Fracture Site Spacing During Closed Reduction After Forearm Fracture: Finite Element Analysis (전완 골절 후 도수 정복 시 골절 부위 간격에 따른 골절 인접 연부 조직의 생체역학적 특성 평가: 유한요소해석)

  • Park, Jun-Sung;Lee, Sang Hyun;Song, Chanhee;Ro, Jung Hoon;Lee, Chiseung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.308-318
    • /
    • 2022
  • The purpose of this study is to evaluate the biomechanical properties of fractured adjacent soft tissue during closed reduction after forearm fracture using the finite element method. To accomplish this, a finite element (FE) model of the forearm including soft tissue was constructed, and the material properties reported in previous studies were implemented. Based on this, nine finite element models with different fracture types and fracture positions, which are the main parameters, were subjected to finite element analysis under the same load and boundary conditions. The load condition simulated the traction of increasing the fracture site spacing from 0.4 mm to 1.6 mm at intervals of 0.4 mm at the distal end of the radioulnar bone. Through the finite element analysis, the fracture type, fracture location, and displacement were compared and analyzed for the fracture site spacing of the fractured portion and the maximum equivalent stress of the soft tissues adjacent to the fracture(interosseous membrane, muscle, fat, and skin). The results of this study are as follows. The effect of the major parameters on the fracture site spacing of the fractured part is negligible. Also, from the displacement of 1.2 mm, the maximum equivalent stress of the interosseous membrane and muscle adjacent to the fractured bone exceeds the ultimate tensile strength of the material. In addition, it was confirmed that the maximum equivalent stresses of soft tissues(fat, skin) were different in size but similar in trend. As a result, this study was able to numerically confirm the damage to the adjacent soft tissue due to the fracture site spacing during closed reduction of forearm fracture.