• Title/Summary/Keyword: Biomechanical Method

Search Result 233, Processing Time 0.027 seconds

The Endotoxin Assay of Contaminated Titanium Implants following Various Techniques of Detoxification (오염된 임프란트 표면의 해독 방법에 따른 내독소 제거 효과에 관한 연구)

  • Park, Joong-Hee;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.71-81
    • /
    • 2004
  • Peri-implantitis could be the result of biomechanical and occlusal overload as well as microbiologic invasion. The dental implant may be more susceptible to dental plaque than the natural tooth, as the predictability of a stable soft tissue attachment complex has not yet been confirmed. With the development of peri-implantitis, the implant surface would be exposed to the oral environment and becomes coated with bacteria. The objective of therapy for this condition is to regain integration of the implant with bone. Since fibroblast adherence to surfaces is impeded by endotoxin, it would seem that decontamination would be desirable to obtain maximum osseointegration. The purpose of this study was to determine whether various chemotherapeutic and mechanical treatments(distilled water, air-powder abrasive, hypersaturated citric acid, tetracycline) can detoxify contaminated titanium implant surface by means of kinetic LAL test. Experimental rough surface titanium disks were fabricated. All of them were divided into two groups(A.a group and P.g group) and each contaminated by A. actinomycetemcomitans and P. gingivalis suspension. Contaminated disks were treated with distilled water, air-powder abrasive, citric acid and tetracycline, and then all disks were placed into LPS-free water for elution. The results were as follows : 1. In A.a group, LPS elute level of all test groups were significantly lower than control group(p<0.05). 2. In A.a group, LPS elute level of test 2, test 3 and test4 groups were significantly lower than that of control group(p<0.05). But, among the test 2, test 3, test4 groups, the significant differences were not detected. 3. In P.g group, LPS elute level of test 2, test 3 and test 4 groups were lower than that of control group(p<0.05). But, among the test groups, the significant differences were not detected. From the result of this study, it would be concluded that air-powder abrasive, hypersaturated citric acid and tetracycline treatments may be effective at reducing endotoxin level on rough titanium implant surfaces, and can be clinically used. But the treatments in peri-implantitis differentially impact osseointegration making one method clinically superior. To gain this knowledges, further molecular biologic and histopathologic studies should be developed.

Effects of Loading on Biomechanical Analysis of Lower Extremity Muscle and Approximate Entropy during Continuous Stair Walking (지속적인 계단 보행에서 부하가 하지 근육의 생체역학적 변인과 근사 엔트로피에 미치는 영향)

  • Kim, Sung-Min;Kim, Hye-Ree;Ozkaya, Gizem;Shin, Sung-Hoon;Kong, Se-Jin;Kim, Eon-Ho;Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.323-333
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the changes of gait patterns and muscle activations with increased loads during stair walking. Also, it can be used as descriptive data about continuous stair walking in a real life setting. Method : Twelve sedentary young male adults(Age: $27.0{\pm}1.8yrs$, Weight: $65.8{\pm}9.9kg$) without any lower extremity injuries participated in this study. Participants performed stair walking up 7 floors and their ascending and descending motion on each floor was analyzed. A wireless electromyography(EMG) were attached on the Rectus Femoris(RF), Biceps Femoris(BF), Gastrocnemius(GN), Tibialis Anterior(TA) muscle to calculate integrated EMG(iEMG), median frequency(MDF) and co-contraction index(CI). Chest and left heel accelerometer signal were recorded by wireless accelerometer and those were used to calculate approximate entropy(ApEn) for analyzing gait pattern. All analyses were performed with SPSS 21.0 and for repeated measured ANOVA and Post-hoc was LSD. Results : During ascending stairs, there were a statistically significant difference in Walking time between 1-2nd and other floors(p=.000), GN iEMG between 2-3th and 6-7th(p=.043) floor, TA MDF between 1-2nd and 5-6th(p=.030), 6-7th(p=.015) floor and TA/GN CI between 2-3th and 6-7th(p=.038) floor and ApEn between 1-2nd and 6-7th(x: p=.003, y: p=.005, z: p=.006) floor. During descending stairs, there were a statistically significant difference in TA iEMG between the 6-5th and 3-2nd(p=.026) floor, and for the ApEn between the 1-2nd and 6-7th(x: p=.037, y: p=.000, z: p=.000) floor. Conclusion : Subjects showed more regular pattern and muscle activation response caused by regularity during ascending stairs. Regularity during the first part of stair-descending could be a sign of adaptation; however, complexity during the second part could be a strategy to decrease the impact.

A Biomechanical Analysis or the Stress Distribution of Dental Implant and Alveolar Bone Utilizing Finite Element Method (유한요소법을 이용한 치과용 고정체와 치조골에서의 응력분포에 대한 생체 역학적 분석)

  • Jung, J.K.;Shin, J.W.;Lee, S.J.;Kim, Y.K.;Kim, J.S.;Park, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.511-514
    • /
    • 1997
  • The objective of this study is to propose a finite element based design of the dental implant replacing unction and shape of natural teeth. For this, geometric actors were varied to investigate stress distribution of the alveolar bone around dental implant. In this study, the results were obtained based on the theory of linear elastic, with geometrically axisymmetric assumption. Geometric actors determining implant shape are ranged as 0.2mm-0.6mm, 0.04mm-0.1mm, 0.46mm-0.84mm or height of thread, radius of curvature of thread, and pitch, respectively. The stresses in the alveolar bone caused by biting force playa major role in determining implant stability. Especially, the stress concentration in the cortical bone causes bone resorption and finally makes the implant unstable. Therefore, the stress distributions were investigated on the side of the alveolar bone focusing on the area of cortical bone. The maximum von Mises stress was found to increase up to 6% as the height of thread increases, while its value was to decrease to 19% when the radius of curvature increase within the assigned ranges. For the variation of pitch, the larger size of pitch results in greater maximum von Mises stress when the length of the implant under consideration is fixed. The existence of the neck below the shoulder did not affect the stress distribution in the region of alveolar bone. However, the stresses on the side of the implant near the neck were found to be different by 20% approximately. Therefore, the neck can provide the stability of the implant against continuing biting movement. As a conclusion, the finite element based study shows a potential in designing the dental implant systematically.

  • PDF

Analysis of Forefoot Bending Angle in Sprint Spikes According to Bobsleigh Start Lap Time for Development of Korean-Specific Bobsledding Shoes

  • Park, Seungbum;Lee, Kyungdeuk;Kim, Daewoong;Yoo, Junghyeon;Jung, Jaemin;Park, Kyunghwan;Park, Sungwon;Kim, Jinhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.315-321
    • /
    • 2016
  • Objective: The aim of this study was to analyze effects of the toe-spring angle of bobsleigh shoes on start speed lap time to develop Korean-specific bobsled shoes suitable for winter environments and for domestic players on the basis of sports science and optimized biomechanical performance. Method: Seven Korean bobsleigh athletes participated in this study, with three pairs of sprint spikes from three companies (Type A, Type B, Type C). To analyze sprint lap time and forefoot bending angle for each shoe, participants were instructed to drag a sled 15 meters from the start line at a maximum sprint. forefoot bending angle was collected by a high speed camera, and lap time speed was measured. Results: Lap time for type B shoes was $3.52{\pm}0.17sec$, type A was $3.55{\pm}0.19sec$, and type C was $3.56{\pm}0.18sec$. Forefoot bending angles were: angle 1, $6.88{\pm}5.55^{\circ}$; angle 2, $9.23{\pm}6.38^{\circ}$; angle 3, $15.56{\pm}5.39^{\circ}$; angle 4, $9.54{\pm}3.85^{\circ}$; angle 5, $9.22{\pm}5.08^{\circ}$; angle 6, $7.66{\pm}6.44^{\circ}$; and angle 7, $4.30{\pm}6.24^{\circ}$ (p<.001). Forefoot bending in angle 3 was as follows: type A, $16.47{\pm}6.01^{\circ}$; type B, $14.30{\pm}4.96^{\circ}$; and type C, $15.90{\pm}5.17^{\circ}$. Conclusion: Hard outsoles and midsoles are better than soft type for reduced start lap time when developing a prototype Korean bobsled shoe.

A Biomechanical Analysis of Four Different Taekwondo Body Punch Types in Horseback-Riding Stance (태권도 주춤 서 몸통지르기 유형별 생체역학적 변인 비교 분석)

  • Kang, Sung-Chul;Kim, Eui-Hwan;Shin, Hyun-Moo;Kim, Sung-Sup;Kim, Tae-Whan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.201-208
    • /
    • 2007
  • The purpose of this study is to compare 4 different body punch types(type 1: a punch using a shoulder, type 2: a punch using a waist, type 3: a punch using lower extremities, and type 4: a punch with elbows by your side at chest level) in horseback-riding stance and establish suitable teaching theory and method, which would be a useful reference to Taekwondo instructors on the spot(in Taekwondo dojangs all around Korea). Five exhibition players from Korean national Taekwondo exhibition team participated in this study. Each participant was asked to perform the four different types of punches and their kinematic and kinetic data were recorded with 7 vicon cameras(125Hz) and two force plates(AMTI, 1200Hz). We analyzed displacement, time, resultant center of body mass trajectory, velocity, trunk angular velocity, and ground reaction force(GRF) from each body segment in body punch and the result. I performed 1-way ANOVA(RM) for average values of each player after standardization and statistical significance was set as p<.05. was as the following ; First, they showed a tendency to take the body punch posture with the biggest motion at a shoulder and on descending order a waist and a knee. Second, a mean time for each body punch on ascending order 0.46sec. for type 2, 0.49sec for type 3, 0.50sec. for type 4, and 0.56sec. for type 1. Third, a mean resultant center of body mass trajectory for each body punch the longest 4.07cm for type 3 and the shortest 2.458cm for type 1. Fourth, a mean of maximal velocity of a fist strike was the fastest 5.99m/s for type 3, 5.93m/s for type 4, 5.67m/s for type 2, and 5.01m/s for type 1 on the descending order. Fifth, a mean of maximal trunk angular velocity of the fastest 495.6deg./sec. for type 4 and 337.7deg./sec. for type 1 on the descending order. Sixth, strongest value was type 3, 2 for anterior-posterior ground reaction force(left -54.89N, right 60.58N), type 4 for medial-lateral GRF(left 83.59N, right -80.12N), and type 3 for vertical GRF(left 341.79N, right 426.11N).

Numerical Analysis on Stress Distribution of Vertebra and Stability of Intervertebral Fusion Cage with Change of Spike Shape (척추체간 유합케이지의 스파이크형상 변화에 따른 척추체의 응력분포 및 케이지의 안정성에 대한 수치적 해석)

  • 심해영;김철생;오재윤
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.361-367
    • /
    • 2004
  • The axial compressive strength, relative 3-D stability and osteoconductive shape design of an intervertebral fusion cage are important biomechanical factors for successful intervertebral fusion. Changes in the stress distribution of the vertebral end plate and in cage stability due to changes in the spike shape of a newly contrived box-shaped fusion cage are investigated. In this investigation, the initial contact of the cage's spikes with the end plate and the penetration of the cage's spikes into the end plate are considered. The finite element analysis is conducted to study the effects of the cage's spike height, tip width and angle on the stress distribution of the vertebral end plate, and the micromigration of the cage in the A-P direction. The stress distribution in the end plate is examined when a normal load of 1700N is applied to the vertebra after inserting 2 cages. The micromigration of the cage is examined when a pull out load of l00N is applied in the A-P direction. The analysis results reveal that the spike tip width significantly influences the stress concentration in the end plate, but the spike height and angle do not significantly influence the stress distribution in the end plate touching the cage's spikes. In addition, the analysis results show that the micromigration of the cage can be reduced by adjusting the spike angle and spike arrangement in the A-P direction. This study proposes the optimal shape of an intervertebral fusion cage, which promotes bone fusion, reduces the stress concentration in a vertebral end plate, and increases mechanical stability.

Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis (지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향)

  • Park, Hyun-Soo;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

Stiffness Analysis of External Fixation System with System Configuration Parameters (시스템 구성 인자를 고려한 외고정장치 시스템의 강성 해석)

  • Kim Yoon Hyuk;Lee Hyun Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.531-536
    • /
    • 2004
  • In fracture treatment with external fixators, the inter-fragmentary movements at the fracture site affect the fracture healing process, and these movements are highly related to the stiffness of external fixation systems. Therefore, in order to provide the optimal fracture healing at the fracture site, it is essential to understand the relationship between the stiffness and the system configurations in external fixation system. In this study we investigated the influences of system configuration parameters on the stiffness in the finite element analysis of an external fixation system of a long bone. The system alignment, the geometric and the material non-linearity of the pin, the joint stiffness and the callus formation were considered in the finite element model. In the first, the system stiffness of the developed finite element model was compared with the experiment data for model validation. The consideration of the joint stiffness and nonlinearity of the model improved the system stiffness results. The joint stiffness, the non-alignment of the system decreased the system stiffness while the callus formation increased the system stiffness. The present results provided the biomechanical basis of rational guidelines for design improvements of external fixators and pre-op. planning to maximize the system stiffness in fracture surgery.

The Effects of Different Surface Level on Muscle activity of the Upper Body and Exercise Intensity during Mountain Climbing Exercise (지면에서의 마운틴 클라이밍 운동 시 상체의 위치 변화가 운동 강도와 근활성도에 미치는 영향)

  • Park, Jun-Ho;Jung, Jae-Hu;Kim, Jong-Geun;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2021
  • Objective: The purpose of this study was to investigate relations and effectiveness about mountain climbling exercise with different level of support surfaces by analyzing heart rate and EMG data. A total of 10 male college students with no musculoskeltal disorder were recruited for this study. Method: The biomechanical analysis was performed using heart rate monitor (Polar V800, Polar Electro Oy, Finland), step-box, exercise mat, and EMG device (QEMG8, Laxtha Inc. Korea, sampling frequency = 1,024 Hz, gain = 1,000, input impedance > 1012 Ω, CMRR > 100 dB). In this research, step-box were used to create different surface levels on the upper body (flat surface, 10% of subject's height, 20% of subject's height, and 30% of subject's hight). Based on these different conditions, data was collected by performing mountain climbing exercise during 30 seconds. Subjects were given 5 minutes of break to prevent muscular fatigue after each exercise. For each dependent variable, a one-way analysis of variance with repeated measures was conducted to find significant differences and Bonferroni post-hoc test was performed. Results: The results of this study showed that exercise intensity was reduced statistically as increased surface level on the upper body. Muscle activity of the upper rectus abdominis and biceps femoris for 30% of surface level was significantly higher than the corresponding values for flat surface. However, the opposite was found in the rectus femoris. In general, muscle activity of the lower rectus abdominis, erector spinae, external oblique abdominis, and gluteus maximus increased when surface level increased, but the differences were not significant. Conclusion: As a result, the increase in surface level of the body would change muscle activity of the upper body, indicating that different surface level of the upper body may cause significant effect on particular muscles to be more active during mountain climbing exercise. Based on results of this study, it is suggested to set up an appropriate surface level to target particular muscle to expect an effective training. It is also important to set adequate surface levels to create an effective training condition for preventing exercise injuries.

A 10-year retrospective study on the risk factors affecting the success rate of internal connection implants after prosthetic restoration (내부연결 임플란트의 보철 수복 후 성공률에 미치는 위험요소에 관한 10년간의 후향적 연구)

  • Seoin Lee;Min-Jeong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.113-124
    • /
    • 2023
  • Purpose. The purpose of this study is to help increase the success rate by analyzing the types and characteristics of implant prosthesis and the survival rate. Materials and methods. Among implants placed between 2011 and 2020 at Sanbon Dental Hospital, College of Dentistry, Wonkwang University, a case restored by a prosthetic surgeon was investigated for the characteristics and correlation of failure. The causes of failure were classified as failure of osseointegration, peri-implantitis, fixture fracture, abutment fracture, screw fracture, screw loosening, prosthesis fracture, and loss of prosthesis retention. Prosthetic method, cantilever presence, placement location, etc. were analyzed for their correlation with implant failure. Results analysis was derived through Chi-square test and Kaplan-Meier survival analysis using SPSS ver 25.0 (IBM, Chicago, IL, USA). Results. A total of 2587 implants were placed, of which 1141 implants were restored with Single Crown and 1446 implants with Fixed Partial Denture, and the cumulative survival rate was 88.1%. The success rate of SC was 86.2% (984) and the success rate of FPD was 89.6% (1295), showing statistically significant differences, among which factors that had significant differences were abutment fracture, screw fracture, and screw loosening (P < .05). Conclusion. As a result of the 10-year follow-up, more failures occurred due to biomechanical factors than biological factors. Further studies on the success of implants will be needed in the future.