• 제목/요약/키워드: Biological Signal Monitoring

검색결과 88건 처리시간 0.037초

실시간 뇌파분석에 관한 연구 (A Study on the Real-time Electroencephalography analysis)

  • 송재성;유선국;김선호;김남현;김기만;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.278-281
    • /
    • 1995
  • In this paper, we have developed EEG (electroencephalography) analyzer for monitoring the condition of brain in neurological surgery. This system is composed of EEG amplifier. personal-computer and BSP (Digital Signal Processor). By parallel processing of DSP, this system can analysis the power spectral density change of EEG in real-time and display the CSA(Compressed Spectral Array) and CDSA(Color Density Spectral array) of EEG. This system was tested by real EEG and showed the change of EEG.

  • PDF

Monitoring of Gene Regulations Using Average Rank in DNA Microarray: Implementation of R

  • Park, Chang-Soon
    • Journal of the Korean Data and Information Science Society
    • /
    • 제18권4호
    • /
    • pp.1005-1021
    • /
    • 2007
  • Traditional procedures for DNA microarray data analysis are to preprocess and normalize the gene expression data, and then to analyze the normalized data using statistical tests. Drawbacks of the traditional methods are: genuine biological signal may be unwillingly eliminated together with artifacts, the limited number of arrays per gene make statistical tests difficult to use the normality assumption or nonparametric method, and genes are tested independently without consideration of interrelationships among genes. A novel method using average rank in each array is proposed to eliminate such drawbacks. This average rank method monitors differentially regulated genes among genetically different groups and the selected genes are somewhat different from those selected by traditional P-value method. Addition of genes selected by the average rank method to the traditional method will provide better understanding of genetic differences of groups.

  • PDF

마이크로 컴퓨터를 이용한 신경근 차단 감시장치의 개발에 관한 연구

  • 전계록;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.257-268
    • /
    • 1990
  • A system has been developed for monitoring the effect of neuromuscular blocking frugs and the neuromuscular function during anesthesia and surgery. This system is composed of software and hardware, the latter are nerve stimulator, force transducer, interface board(preamplifier, filter, peripheral input/output) and personal computer (apple ll) , the former are programmed in ASSEMBLY and BASIC language. The nerve stimulator which is controlled by personal computer is capable of delivering single shocks at o.)Hz, train of four at 2Hz and tetanic stimulation at 30, 100, 200Hz. The response, adduction of the thumb, is sensed by the force transducer. The output of the force transducer Is amplified, filtered, converted digital signal and then processed by the per- sonal computer. The personal computer quantia4es twitch and traln of four tesponse and calculates the 74 ratio (Ta/Tl )between the first and fourth response of train of four. This ratio is used to estimate the level of the neuromuscular block. This system has reaserch potential for determining the effect of newer neuromuscular blocking drugs for comparlsion with presently used drugs of alternatively, for delerminig the effects of blocking drugs in altered physilogical states.

  • PDF

ECG-NIBP 환자감시장치 개발 (Development of ECG-NIBP Patient Monitoring System)

  • 김남현;심원흠;이건기;라상원;김경하
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.315-318
    • /
    • 1997
  • The ECG-NIBP patient monitor consist of Noninvasive Blood Pressure(NIBP) module that have micro controller inside. This module transfer data by serial communication to the main processor. This system apply the fuzzy inflating method to reduce the blood pressure measuring time, and moving artifact removing algorithm, several parameters used or more accurate measurement. The ECG monitor use the Digital Signal Processor(DSP) or digital filtering, peak detection, heart rate calculation. This system also offer convenient user interface by rotary key, menu bar. With 7" CRT display, auxiliary TFT LCD display adapted to display information on wide screen.

  • PDF

전자 태아감시장치 신호 분석의 알고리듬(Algorithm)에 대한 예비적 연구 (A Preliminary Study on the Algorithm of Signal Analysis of Electronic Fetal Monitoring System)

  • 윤홍준;김용만;목정은;정규식
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.270-273
    • /
    • 1995
  • 중앙 집중식 태아 전자감시 시스템은 태아의 안녕을 판정하는 중요한 평가방법이다. 그러나, 태아감시 시스템은 입력 신호의 장기간의 변동 추이를 검사해야 하며, 따라서 해석하는 사람의 집중력이 쉽게 저하될 수 있다. 컴퓨터를 이용한 태아 감시장치 신호의 자동해석은 분만장의 의사 및 간호사의 업무를 한층 부담없고 손쉽게 할 수 있다. 본 연구에서는 중앙 집중식 태아감시 시스템에서 간단하고 효율적으로 적용할 수 있는 신호 해석 알고리듬을 제시하고, 그에 따른 고속 프로그램을 구현하여 실제 시스템에 적용해 봄으로써 신호 해석 알고리듬의 실효성을 검토해 보고자 한다.

  • PDF

지력측정을 이용한 작업 적합성 평가 시스템개발 (A Development of Working Adaptation Evaluation System using Finger Force Measurement)

  • 변미경;허웅;한상휘;김정국
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2002년도 춘계학술대회
    • /
    • pp.31-36
    • /
    • 2002
  • In this paper, we developed a working adaptation evaluation system using finger force measurement which interact between material and biological system. The system consists of a finger force transducer, a signal conditioner, an A/D converter, a computer, and a software system for data processing. The finger force transducer is made by a load cell and a special mechanism. The data processing software controls the A/D converter, data monitoring, and data analysis for group classification. The developed system were tested by 4 different materials in left hand and the finger forte transducer in the other hand's thumb and index finger with 16 persons. As the results of experiments, the developed system could measure the finger force quantitatively and classify the measured values into four groups.

  • PDF

미세파상 패턴 ECM 에서 세포질 FAK 신호의 실시간 FRET 이미징 (Real-time FRET imaging of cytosolic FAK signal on microwavy patterned-extracellular matrix (ECM))

  • 서정수;장윤관;김태진
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권1호
    • /
    • pp.1-6
    • /
    • 2019
  • Human mesenchymal stem cells (hMSC) are multipotent stromal cells that have great potential to differentiate into a variety of cell types such as osteocytes, chondrocytes, and myocytes. Although there have been many studies on their clinical availability, little is known about how intracellular signals can be modulated by topographic features of the extracellular matrix (ECM). In this study, we investigated whether and how microwavy-patterned extracellular matrix (ECM) could affect the signaling activity of focal adhesion kinase (FAK), a key cellular adhesion protein. The fluorescence resonance energy transfer (FRET)-based FAK biosensor-transfected cells are incubated on microwavy-patterned surfaces and then platelet derived growth factor (PDGF) are treated to trigger FAK signals, followed by monitoring through live-cell FRET imaging in real time. As a result, we report that PDGF-induced FAK was highly activated in cells cultured on microwavy-patterned surface with L or M type, while inhibited by H type-patterned surface. In further studies, PDGF-induced FAK signals are regulated by functional support of actin filaments, microtubules, myosin-related proteins, suggesting that PDGF-induced FAK signals in hMSC upon microwavy surfaces are dependent on cytoskeleton (CSK)-actomyosin networks. Thus, our findings not only provide new insight on molecular mechanisms on how FAK signals can be regulated by distinct topographical cues of the ECM, but also may offer advantages in potential applications for regenerative medicine and tissue engineering.

패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극 (Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System)

  • 이정수;이원규;임용규;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

침대 패드 형태의 용량성 전극에서 측정된 심전도 신호를 처리하기 위한 자동 잡음 제거 및 피크 검출 알고리즘 (Automatic Noise Removal and Peak Detection Algorithm for ECG Measured from Capacitively Coupled Electrodes Included within a Cloth Mattress Pad)

  • 이원규;이홍지;윤희남;정기성;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권4호
    • /
    • pp.87-94
    • /
    • 2014
  • Recent technological advances have increased interest in personal health monitoring. Electrocardiogram(ECG) monitoring is a basic healthcare activity and can provide decisive information regarding cardiovascular system status. In this study, we developed a capacitive ECG measurement system that can be included within a cloth mattress pad. The device permits ECG data to be obtained during sleep by using capacitive electrodes. However, it is difficult to detect R-wave peaks automatically because signals obtained from the system can include a high level of noise from various sources. Because R-peak detection is important in ECG applications, we developed an algorithm that can reduce noise and improve detection accuracy under noisy conditions. Algorithm reliability was evaluated by determining its sensitivity(Se), positive predictivity(+P), and error rate(Er) by using data from the MIT-BIH Polysomnographic Database and from our capacitive ECG system. The results showed that Se = 99.75%, +P = 99.77%, and Er = 0.47% for MIT-BIH Polysomnographic Database while Se = 96.47%, +P = 99.32%, and Er = 4.34% for our capacitive ECG system. Based on those results, we conclude that our R-peak detection method is capable of providing useful ECG information, even under noisy signal conditions.

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.