• 제목/요약/키워드: Biocompatibility

검색결과 796건 처리시간 0.03초

Dental Implant 금속재료의 성분차이에 따른 세포독성에 관한 연구 (A STUDY ON CYTOTOXICITY OF THE NEW TITANIUM ALLOYS FOR DENTAL IMPLANT MATERIAL)

  • 김태인;한준현;이인석;이규환;신명철;최부병
    • 대한치과보철학회지
    • /
    • 제34권4호
    • /
    • pp.675-686
    • /
    • 1996
  • Today, dental implants are an acceptable alternative, capable of providing bone-anchored fixed prostheses for improved quality of life and self esteem for many patients. Research advances in dental implantology have led to the development of several different types of materials, and it is anticipated that continued research will likewise lead to advanced dental implant materials. Currently used pure titanium has relatively low hardness and strength which possibly limits its ability to resist the functional loads as a dental implant. Ti-6Al-4V also has potential problems such as corrosion resistance, bone biocompatibility etc. The carefully selected Zr, Nb, Ta, Pd, In constituents could improve mechanical strength, corrosion resistance, and biocompatibility compared to that of currently used implant metals. On the basis of the totality of the data from our study, it can be concluded that new titanium alloys containing Zr, Nb, Ta, Pd, In are able to provide improved mechanical properties, corrosion resistance and biocompatibility to warrant further investigation of it's potential as new biomaterials for dental implants.

  • PDF

In Vitro Biocompatibility Test of Multi-layered Plasmonic Substrates with Flint Glasses and Adhesion Films

  • Kim, Nak-Hyeon;Byun, Kyung Min;Hwang, Seoyoung;Lee, Yena;Jun, Sang Beom
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.174-179
    • /
    • 2014
  • Since in vitro neural recording and imaging applications based on a surface plasmon resonance (SPR) technique have expanded dramatically in recent years, cytotoxicity assessment to ensure the biosafety and biocompatibility for those applications is crucial. Here, we report the cytotoxicity of the SPR substrate incorporating a flint glass whose refractive index is larger than that of a conventional crown glass. A high refractive index glass substrate is essential in neural signal detection due to the advantages such as high sensitivity and wide dynamic range. From experimental data using primary hippocampal neurons, it is found that a lead-based flint glass is not appropriate as a neural recording template although the neuron cells are not directly attached to the toxic glass. We also demonstrate that the adhesion layer between the glass substrate and the gold film plays an important role in achieving the substrate stability and the cell viability.

골육세포 성장 촉진을 위한 스마트 써피스 텍스처링 임플란트 스템 제작 기술 (Smart Surface Texturing Implant Stem for Enhancement of Osteoblast Cell Biocompatibility)

  • 김경한;이제훈;박종권;진석원;최완해;이홍진
    • 한국정밀공학회지
    • /
    • 제31권5호
    • /
    • pp.375-380
    • /
    • 2014
  • To enhance biocompatibility between the orthopedic implant stem and obsteoblast cells, bone-forming cells, micro-size holes are patterned in Ti plate surface. Initially, the house built laser power stabilization system is applied to the laser micro patterning machine to convince repeatable result. Various pulse widths are irradiated Ti plate and relationship between diameters of patterned holes and pulsed width is derived. Effect of multi pulse is observed and optimal pulse number is considered to avoid heat affected zone. After MG-63 osbeoblast cells are cultured, micro patterned Ti plates are compared with control plates. In SEM image, cells are well aligned and aggregation is observed in both 60, and $100{\mu}m$ patterned plates. Finally, free form surface stem model is prepared to test micro hole patterning.

침의 재료인 스테인리스강 STS304 및 STS316의 생체적합성에 대한 고찰 (Biocompatibility of STS304, 316 acupuncture needle)

  • 황의형;구성태;이인환;이민호;장인수
    • Korean Journal of Acupuncture
    • /
    • 제24권1호
    • /
    • pp.59-63
    • /
    • 2007
  • Objectives : To discuss the biocompatibility of stainless steel for using acupuncture needles. Results and Conclusions : It is widely assumed that stainless steel is one of the good corrosion-resistant materials and is safe for human body, Most of metal acupuncture needles are made of STS304 and STS316 in light of human body safety: STS304 in more differences between STS304 and STS316 in light of human body safety: STS304 is more vulnerable to oxidation than STS316. A variety of literature survey showed that although STS316 is more corrosion-resistant than STS304 there is no evidence supporting the hypothesis that STS304 has the potential danger to human body, Further study would be necessary to draw more decisive conclusion.

  • PDF

Designing Materials for Hard Tissue Replacement

  • Nath, Shekhar;Basu, Bikramjit
    • 한국세라믹학회지
    • /
    • 제45권1호
    • /
    • pp.1-29
    • /
    • 2008
  • In last two decades, an impressive progress has been recorded in terms of developing new materials or refining existing material composition/microstructure in order to obtain better performance in biomedical applications. The success of such efforts clearly demands better understanding of various concepts, e.g. biocompatibility, host response, cell-biomaterial interaction. In this article, we review the fundamental understanding that is required with respect to biomaterials development, as well as various materials and their properties, which are relevant in applications, such as hard tissue replacement. A major emphasize has been placed to present various design aspects, in terms of materials processing, of ceramics and polymer based biocomposites, Among the bioceramic composites, the research results obtained with Hydroxyapatite (HAp)-based biomaterials with metallic (Ti) or ceramic (Mullite) reinforcements as well as $SiO_2-MgO-Al_2O_3-K_2O-B_2O_3-F$ glass ceramics and stabilized $ZrO_2$ based bioinert ceramics are summarized. The physical as well as tribological properties of Polyethylene (PE) based hybrid biocomposites are discussed to illustrate the concept on how can the physical/wear properties be enhanced along with biocompatibility due to combined addition of bioinert and bioactive ceramic to a bioinert polymeric matrix. The tribological and corrosion properties of some important orthopedic metallic alloys based on Ti or Co-Cr-Mo are also illustrated. At the close, the future perspective on orthopedic biomaterials development and some unresolved issues are presented.

Effect of the Mg Ion Containing Oxide Films on the Biocompatibility of Plasma Electrolytic Oxidized Ti-6Al-4V

  • Lee, Kang;Choe, Han-Cheol
    • 한국표면공학회지
    • /
    • 제49권2호
    • /
    • pp.135-140
    • /
    • 2016
  • In this study, we prepared magnesium ion containing oxide films formed on the Ti-6Al-4V using plasma electrolytic oxidation (PEO) treatment. Ti-6Al-4V surface was treated using PEO in Mg containing electrolytes at 270V for 5 min. The phase, composition and morphology of the Mg ion containing oxide films were evaluated with X-ray diffraction (XRD), Attenuated total reflectance Fourier transform infrared (ATR-FTIR) and filed-emission scanning electron microscopy (FE-SEM) with energy dispersive X-ray spectrometer (EDS). The biocompatibility of Mg ion containing oxide films was evaluated by immersing in simulated body fluid (SBF). According to surface properties of PEO films, the optimum condition was formed when the applied was 270 V. The PEO films formed in the condition contained the properties of porosity, anatase phase, and near 1.7 Ca(Mg)/P ratio in the oxide film. Our experimental results demonstrate that Mg ion containing oxide promotes bone like apatite nucleation and growth from SBF. The phase and morphologies of bone like apatite were influenced by the Mg ion concentration.

BIocompatible Reduced Graphene Oxide Multilayers for Neural Interfaces

  • 김성민;주필재;안국문;김병수;윤명한
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.278.1-278.1
    • /
    • 2013
  • Among the prerequisites for stable neural interfacing are the long-term stability of electrical performance of and the excellent biocompatibility of conducting materials in implantable neural electrodes. Reduced graphene oxide offers a great potential for a variety of biomedical applications including biosensors and, particularly, neural interfaces due to its superb material properties such as high electrical conductivity, decent optical transparency, facile processibility, and etc. Nonetheless, there have been few systematic studies on the graphene-based neural interfaces in terms of biocompatibility of electrode materials and long term stability in electrical characteristics. In this research, we prepared the primary culture of rat hippocampal neurons directly on reduced graphene oxide films which is chosen as a model electrode material for the neural electrode. We observed that the viability of primary neuronal culture on the present structure is minimally affected by nanoscale graphene flakes below. These results implicate that the multilayer films of reduced graphene oxides can be utilized for the next-generation neural interfaces with decent biocompatibility and outstanding electrical performance.

  • PDF

Physical Properties, Antimicrobial Efficacy, and Biocompatibility of Denture Base Resins Coated with Natural Peony Extract

  • Myung-Jin Lee;Yu-Ri Choi;Min-Kyung Kang
    • 한국재료학회지
    • /
    • 제33권2호
    • /
    • pp.47-53
    • /
    • 2023
  • When exposed to different types of bacteria in the oral cavity, denture based resins are prone to bacteria attachment. The purpose of this study was to investigate the physical, biological, and antimicrobial properties of denture base resins coated with Peony extract (200, 400, and 600 ㎍/mL). Specifically, the surface properties (microhardness, contact angle, and color change of the coated specimens), cell cytotoxicity (measured using MTT assay), and antimicrobial activity (against S. mutans (Streptococcus mutans) and C. albicans (Candida albicans) using a growth inhibition assay) were evaluated. The polyphenol content was measured using ultraviolet-visible (UV-vis) spectrometry. The experimental groups (specimens coated with Peony extract) and a control group (specimens coated without Peony extract) were statistically compared using a one-way analysis of variance and Tukey's post-hoc tests. No statistically significant differences in surface properties or cell cytotoxicity were observed, which demonstrated their biocompatibility. Conversely, a statistically significant difference in antimicrobial activity was observed between the experimental and control groups after 48 h. This confirms the antimicrobial activity of the denture base resin coated with Peony extract and demonstrates that it is a promising dental material for preventing stomatitis.

MoS2 코팅된 치과용 임플란트의 표면특성과 생체적합성 (Surface Characteristics and Biocompatibility of MoS2-coated Dental Implant)

  • 권민기;이준식;김미은;최한철
    • Corrosion Science and Technology
    • /
    • 제23권1호
    • /
    • pp.72-81
    • /
    • 2024
  • The Ti-6Al-4V alloy is widely used as an implant material due to its higher fatigue strength and strengthto-weight ratio compared to pure titanium, excellent corrosion resistance, and bone-like properties that promote osseointegration. For rapid osseointegration, the adhesion between the titanium surface and cellular biomolecules is crucial because adhesion, morphology, function, and proliferation are influenced by surface characteristics. Polymeric peptides and similar coating technologies have limited effectiveness, prompting a demand for alternative materials. There is growing interest in 2D nanomaterials, such as MoS2, for good corrosion resistance and antibacterial, and bioactive properties. However, to coat MoS2 thin films onto titanium, typically a low-temperature hydrothermal synthesis method is required, resulting in the synthesis of films with a toxic 1T@2H crystalline structure. In this study, through high-temperature annealing, we transformed them into a non-toxic 2H structure. The implant coating technique proposed in this study has good corrosion resistance and biocompatibility, and antibacterial properties.

In vivo와 in vitro 에서 양극산화 처리한 타이타늄 시편의 상대적인 생체적합성 평가 (Relative Biocompatibility Evaluation of Anodized Titanium Specimens in vivo and in vitro)

  • 이유미;이은정;염동선;김도순;이성태;김병일;조현욱
    • 생명과학회지
    • /
    • 제16권2호
    • /
    • pp.302-309
    • /
    • 2006
  • 처리하지 않은 타이타늄과 양극 산화 처리한 타이타늄 시편의 생체적합성을 평가하기 위해, 시편을 마우스의 복부 피하 조직에 이식하고 2주 동안 생존시켰다. 그 시편에 대한 복부 피하 결합조직의 반응을 조직학적으로 조사하였다. 시편 주위를 둘러싸는 섬유성 결합조직 막이 관찰되었으며 이 막은 섬유모세포, 섬유세포 및 기타 세포로서 중성호성백혈구, 대식세포, 거대다핵세포 등으로 이루어져 있었다. 시편을 둘러싸는 이 막에 새로이 형성된 혈관이 존재하기도 하였다. 임플란트와 접하는 섬유성 막에 거대다핵세포가 관찰되었다. 섬유성 막에 있는 세포 종류와 막의 두께를 조사하였다. 막에 있는 대부분의 세포는 섬유모세포와 섬유세포이었다. 양극 산화 처리를 하지 않은 타이타늄 시편에 비해 산화 처리를 한 시편을 둘러싸는 섬유성 막의 평균 두께가 더 얇았다. 또한 타이타늄 시편의 생체적합성을 세포 배양법으로 조사하였다. 산화 처리를 한 시편 위에서 배양한 MG-63 세포의 수가 유의하게 증가되었다. 이런 결과들은 in vivo 와 in vitro 실험에서 산화 처리를 한 타이타늄 시편이 생체적합성을 증가시키는데 효과적이라는 것을 말해준다.