• Title/Summary/Keyword: Biochemical oxygen demand (BOD)

Search Result 182, Processing Time 0.026 seconds

An aerobic granular sludge process for treating low carbon/nitrogen ratio sewage

  • Yae, JaeBin;Ryu, JaeHoon;Tuyen, Nguyen Van;Kim, HyunGu;Hong, SeongWan;Ahn, DaeHee
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.238-245
    • /
    • 2019
  • This study investigated the characteristic of aerobic granular sludge (AGS) process to treat the sewage having low carbon/nitrogen ratio (Biochemical oxygen demand ($BOD_5$):Total nitrogen (T-N), 4.5:1) in sequencing batch reactor (SBR). The removal efficiency of $BOD_5$, suspended solid (SS), T-N and phosphorus ($PO_4{^{3-}}$-P) were 92.6%, 64.3% and 90.1%. Concentration and size of AGS were changed in proportion to the organic matters and nitrogen concentration of the influent (Concentration and size of AGS: 1,700-3,000 mg/L, 0.5-1.0 mm). Mixed liquor suspended solid (MLSS) also changed with the concentration of AGS (MLSS: 2,000-3,500 mg/L). When the settling time was shortened from 15 min to 10 min, size and shape of AGS were maintained (Size of AGS: 1.0-1.5 mm). In addition, the concentration of AGS and MLSS increased (Concentration of AGS: 3,500 mg/L, MLSS: 4,000 mg/L). Concentration, size and shape of AGS were affected the settling time of the reactor more than the concentration of organic matter and nitrogen in the influent. In the results of removal efficiency and changes in AGS, we confirmed that the SBR process using AGS can be used to treat the sewage having low carbon/nitrogen ratio by applying short settling time.

A Study on the Selection of the Total Pollution Load Management at Tributaries by Evaluation of Water Quality Volatility: Case Study for Chungcheongnam-do (수질변동성 평가를 통한 지류총량제 도입 대상유역 선정에 관한 연구: 충청남도를 중심으로)

  • Jeongho Choi;Hongsu Kim;Byunguk Cho;Sanghyun Park;Mukyu Lee;Byeonggu Lee;Uram Kang
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.5
    • /
    • pp.377-389
    • /
    • 2023
  • Chungcheongnam-do has been measuring the flow rate and water quality of streams in the province once a month since 2011 in order to water environment policies. Based on the results, after evaluating the coefficient of variation and the tendency of the water quality trend by using the Mann-Kendall test and Sen's Slope for each stream, the streams subject to priority introduction of Total Pollution Load Management at Tributaries were selected through the Stream Grouping Method. The water quality trend analysis results for 125 streams using the Mann-Kendall test and Sen's Slope were evaluated as streams showing a tendency of deteriorating water quality Biochemical oxygen demand (BOD): 13 streams, Total Phosphorus (T-P): 16 streams). Streams with deteriorating water quality were classified into A-D groups using the Stream Grouping Method. Group A, which has a high flow rate and high water quality, is a stream that requires priority management, and was selected as a stream for introduction of Total Pollution Load Management at Tributaries. There are 7 streams that need to be introduced into the BOD category, and there are 7 streams that need to be introduced into the T-P category. In this study, based on flow and water quality monitoring data accumulated over a long period of time (2011-2022), statistical techniques are used to select watersheds in which water quality is deteriorating. Accordingly, it is expected that it will be useful in establishing a water quality improvement plan in the future.

A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities (국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구)

  • Chan-woo Jeong;Sun-ick Lee;Sung-woo Shin;Chang-hyun Song;Bu-geun Jo;Jae-won Choi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

The Quality of Water and Distribution of Vegetation According to Land Use Pattern (토지이용패턴에 따른 하천수질과 식생분포)

  • Oh, Young-Ju;Kang, Byoung-Wha;Kim, Byoung-Woo;Kim, Sung-Pil;Han, Min-Su;Kim, Jin-Ho;Na, Young-Eun
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.1
    • /
    • pp.34-39
    • /
    • 2006
  • The land use pattern, water quality and vegetation were investigated in the six tributaries, including Hanggeumcheon and Satancheon of the Namhan hydrosphere, Iksancheon, Jeonjucheon and Gosancheon of the Mankyung hydrosphere as well as Jongeupcheon of the Dongjin hydrosphere. Forest and farmland area were extensive in Hanggeumcheon, Satancheon and Gosancheon. Farmland and livestock area were wide in Iksancheon. Jeonjucheon were occupied with broad urban. Industrial and urban area were extensive in Jongeupcheon. The loading amounts of biochemical oxygen demand (BOD), total nitrogen (T-N), total phosphorus (T-P) of Iksancheon and chemical oxygen demand (COD) of Jeonjucheon were determined to be very high, respectively. The quality of water in Hanggeumcheon, Satancheon and Gosancheon were determined to be good quality. The species diversity was lower in the down stream than in the upper stream except for the Gosancheon. Life form of plane were mostly perennial plane in the upper stream and annual plants in the down stream of rivers. It was estimated that there is high level of disturbance in the down stream of rivers. The quality of water was significantly correlated with farmland and forest area. In conclusion, human impact, such as farmland and housing lot exerted an influence on the disturbance of down stream and the water quality of rivers.

A Study on the Design Factors of the Cylinder-Shaped Filter for Improving Reservoir Water Quality (호소수질 개선을 위한 원통형 여과장치의 설계요소 연구)

  • Lee, Sun-Ho;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.655-662
    • /
    • 2009
  • In order to obtain knowledge on the design and operation of practical?scale Cylinder-Shaped Filters, pilot experiments were conducted to observe the effects of stepwise augmentation of production rate on water quality and clogging. A production rate increase from 0.8 L/min to 2.4 L/min did not appear to affect the removal efficiencies of BOD(Biochemical Oxygen Demand), SS(Suspended Solids), and turbidity, as the values were maintained around 80%, over 95%, and over 90% respectively;however, COD(Chemical Oxygen Demand) removal decreased from 44% to 29%. In addition, results indicated an inverse relationship between production rate and detention time required to remove unit contaminant concentration, the observed detention time in the filter to remove 1 mg-COD/L being 83 minutes for the production rate of 0.8 L/min and 45 minutes for the production rate of 2.4 L/min, suggesting that a relatively higher production rate is likely to be more advantageous in the purification of reservoir water when compared to a lower production rate. Clogging was observed to originate from the surface and advance to the center of the filter, and although clogging seemed to increase as the production rate increased, this did not cause any difficulties in normal functioning of the filter for more than 2 years of operation, suggesting that this filter system can be used effectively in the purification of reservoir water.

Application of Subsurface Flow Wetland using the Phragmites australis for Water Quality Improvement of the Agricultural Reservoi (농업용 저수지 수질개선을 위한 지하흐름 갈대 인공습지의 적용)

  • Nam, Gui Sook;Pae, Yo Sop;Kim, Hyung Joong;Lee, Sang Joon;Lee, Gwang Sik
    • Journal of Wetlands Research
    • /
    • v.6 no.4
    • /
    • pp.59-69
    • /
    • 2004
  • Constructed wetlands are regarded as an important water treatment system for agricultural water quality improvement and management. The purpose of this study is to evaluate the application of subsurface flow wetland(SFW), using the Pharagmites australis as macrophytes, and to clarify the basic and essential factors to be considered in the construction and management of constructed wetlands. This study was carried out relatively short hydraulic residence time(HRT), 6hr ~ 72hr (3days), using eutrophic reservoir water with relatively low concentrations of influent and large quantity to be treated. The effluent satisfied the criteria of agricultural water quality. Removal efficiencies of Biochemical oxygen demand(BOD), Chemical oxygen demand(COD), Suspended solids(SS) and Chlorophyll a(Chl-a) were high in HRT 24hr, not any more significant increasement of removal efficiencies in HRT 48hr and 72hr. However, removal efficiencies of nitrogen and phosphorus increased as HRT increased, showing the highest efficiency at the 72hr of HRT in nitrogen, and 48hr in phosphorous. The SFW was very effective system for reservoir water quality improvement, and had the advantages of the reduction of purchasing cost to land required, lack of odors, and harmful insects, especially mosquito, the improvement of the scenic beauty and minimal risk of public exposure. Therefore, it was evaluated that the SFW was very available water treatment system for the water quality improvement of agricultural reservoir. However, it was need to consider with application of the SFW in high cost of construction and troublesome of management.

  • PDF

Changes of Microbial Community Structure According to a Changes of Season and Influent Characteristics in Biological Wastewater Treatment (생물학적 폐수처리 공정에서의 계절 및 유입수 성상 변화에 따른 미생물 군집 특성 변화)

  • Son, Hyeng-Sik;Son, Hee-Jong;Kim, Mi-A;Ryu, Eun-Yeon;Lee, Geon;Lee, Sang-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.780-786
    • /
    • 2010
  • The bacterial community structure in biological reactor in wastewater treatment system was investigated by denaturing gradient gel electrophoresis (DGGE) and fluorescent in situ hybridization (FISH). Samples were collected at different three points in wastewater treatment system. Through treatment processes, BOD (biochemical oxygen demand) and COD (chemical oxygen demand) of was removal efficiency was 83.1~98.6%, 67.2~85.2% respectively. Microbial community of aerobic tank and oxic tank were similar but anoxic tank was different (RRP group was increased about tripple) by DGGE and FISH in sludge (2007 October and 2008 January). Samples in 2007 October and 2008 January were dominant ${\alpha}$-Proteobacteria and CF group respectively. Sludge in 2008 April were different comparing former results dominant others as 65~80%. Others group was dominant. Eubacteria by FISH with the probe EUB338 was about $1.7{\sim}7.6{\times}10^9\;cells/mL$. It could be successfully observed bacterial community in biological wastewater system.

Water Quality Characteristics of the Major Tributaries in Yeongsan and Sumjin River Basin using Statistical Analysis (통계분석을 이용한 영산강·섬진강수계 주요 유입지천의 수질 특성)

  • Park, Jinhwan;Jung, Jaewoon;Kim, Daeyoung;Kim, Kapsoon;Han, Sungwook;Kim, Hyunook;Lim, Byungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.2
    • /
    • pp.171-181
    • /
    • 2013
  • In this study, we report the water quality characteristics of pollutants for 4 major tributaries in the Yeongsan and Sumjin river basins using statistical analysis, such as regression equation and factor analysis. The flow rate and water qualtiy data collected from 4 sampling sites(Hwangryoung A, Jiseok A, Chooryeong A, Osu A) in the Yeonsan and Sumjin river basin during the past 3 years were analyzed for 11 parameters(flow rate, dissolved oxgen, pH, water temperature, electric conductivity, biochemical oxygen demand, chemical oxygen deman, total organic carbon, total nitorgen, total phosphorus, suspended solid). The results showed that the concentrations of BOD, COD, TOC, T-N, T-P in Hwangryoung A(HW) and Jiseok A(JS) of the Yeongsan river basin were decreased as the flow rate was increased. This means that rather than nonpoint soources, point sources affect water quality. In the cases of Chooryeong A(CR) and Osu A(OS) in the Sumjin river basin, howerever, nonpoint sources than point sources are an important factor that affects the water quality. Also, the factor analysis technique was employed to analyze principal component influencing on water quality. The results revealed that the first principal component in HW was correlated with EC, DO, T-N, water temperature. This "nitrogen influx according to seasonal pattern" factor may be interpreted. In JS, the first principal component was correlated with BOD, COD, TOC and is likely to represent "organic matter" processes. In CR and OS, BOD, COD, TOC, SS and T-P were significantly correlated and is considered as representing "Organic matter and adsorption of phosphorus on sediments influx". This study is expected to contribute to the effective pollution control/management of the surfac waters in the study sites.

Water Quality Assessment and Turbidity Prediction Using Multivariate Statistical Techniques: A Case Study of the Cheurfa Dam in Northwestern Algeria

  • ADDOUCHE, Amina;RIGHI, Ali;HAMRI, Mehdi Mohamed;BENGHAREZ, Zohra;ZIZI, Zahia
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.563-573
    • /
    • 2022
  • This work aimed to develop a new equation for turbidity (Turb) simulation and prediction using statistical methods based on principal component analysis (PCA) and multiple linear regression (MLR). For this purpose, water samples were collected monthly over a five year period from Cheurfa dam, an important reservoir in Northwestern Algeria, and analyzed for 12 parameters, including temperature (T°), pH, electrical conductivity (EC), turbidity (Turb), dissolved oxygen (DO), ammonium (NH4+), nitrate (NO3-), nitrite (NO2-), phosphate (PO43-), total suspended solids (TSS), biochemical oxygen demand (BOD5) and chemical oxygen demand (COD). The results revealed a strong mineralization of the water and low dissolved oxygen (DO) content during the summer period. High levels of TSS and Turb were recorded during rainy periods. In addition, water was charged with phosphate (PO43-) in the whole period of study. The PCA results revealed ten factors, three of which were significant (eigenvalues >1) and explained 75.5% of the total variance. The F1 and F2 factors explained 36.5% and 26.7% of the total variance, respectively and indicated anthropogenic pollution of domestic agricultural and industrial origin. The MLR turbidity simulation model exhibited a high coefficient of determination (R2 = 92.20%), indicating that 92.20% of the data variability can be explained by the model. TSS, DO, EC, NO3-, NO2-, and COD were the most significant contributing parameters (p values << 0.05) in turbidity prediction. The present study can help with decision-making on the management and monitoring of the water quality of the dam, which is the primary source of drinking water in this region.

Water Quality in Commercial Channel Catfish Ponds and Its Receiving Water Bodies (차넬메기 양어장의 수질과 주변 자연 하천수와의 관계)

  • SEOK Kyu-jin;BOYD C. E.
    • Journal of Aquaculture
    • /
    • v.6 no.3
    • /
    • pp.187-197
    • /
    • 1993
  • Studies related to water quality in catfish ponds were conducted on commercial catfish production ponds and compared with its receiving streams' water quality in central and west-central Alabama. The ponds were stocked with 10,000 fish/ha. The ponds were aerated nightly (0000-0600 hrs). Fish were fed to satiation at about the same time, six-days a week. In order to assess the pollutional strength of effluents from commercial channel catfish ponds, water samples were collected during each calender season from fall 1990 through summer 1991, and selected water quality variables were monitored. Mean values for water temperature, dissolved oxygen concentration, pH, settleable solids, total suspended soilds, volatile solids, total phosphorus, soluble reactive phosphate, biochemical oxygen demand, total ammonia nitrogen, nitrite, nitrate, and total Kjeldahl nitrogen were basically the same (P> 0.05) between samples taken from the surface and near the bottom. Concentrations of most water quality variables of catfish ponds were higher than those of receiving streams, and especially it had much higher average concentrations of nitrogen and phosphorus than streams.

  • PDF