• Title/Summary/Keyword: Biochemical corrosion

Search Result 27, Processing Time 0.027 seconds

A Study on the Development of ppb Level Dissolved Oxygen Measuring Technology using Clark Cell (Clark Cell을 이용한 ppb Level 용존산소 측정기술 개발에 관한 연구)

  • 정경열;이후락;동은석;이수태;류길수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.197-201
    • /
    • 2001
  • Measuring of the dissolved oxygen is widely used for the environmental control of natural waters, sewage waste treatment, medical and biochemical studies, soil husbandry, food and drug process control, and prevention of corrosion in boilers. Especially, a power plants need special management for preventing accidents from corrosion, therefore, it is essential to measure the concentration of dissolved oxygen in real-time. In this paper we present a method of measuring dissolved oxygen very accurately up to ppb units. This method, called polarographic method, is based on the measures of the electric current generated by the oxidation process in cathode and de-oxidation process in anode, assuming that the amount of the current is proportional to the density of dissolved oxygen.

  • PDF

Evaluation of Resistance to Biochemical Corrosion by Simulation Test (시뮬레이션 시험에 의한 생화학적 부식 저항성 평가)

  • Kim, Gyu-Yong;Lee, Eui-Bae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.903-906
    • /
    • 2008
  • To analyze the growth of SOB (Thiobacillus novellus) and biochemical corrosion of concrete, simulation test method and device were developed. And two types of simulation tests were conducted according to a transplant method and a concentration of H2SO4. As a result, the SOB growth in distinct manners and antibiosis of specimen were observed. In the case of the specimens indirectly transplanted with SOB through culture solution submersion at a hydrogen sulfide level of 120ppm, the rapid activation of SOB and the resulting sulfuric acid production were observed. However, SOB were shown to grow rapidly and then die out in a relative short period of time. Meanwhile, in the case of the specimens directly transplanted with SOB at a hydrogen sulfide level of 50ppm, the long-term growth of SOB was possible, but the production of sulfuric acid by SOB did not progress. In the case of the antibiotic metal-mixed specimens, SOB with destroyed cell membranes and internal organizations were observed.

  • PDF

Development on Antibiotic Concrete Mixed with Antibacterial Metals and Metallic Salts (금속 및 금속염계 항균제가 혼입된 항균 콘크리트 개발)

  • Choi, Hong-Shik;Heo, Kwon;Lee, Ho-Beom;Lee, Si-Woo;Kwak, Hong-Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.136-143
    • /
    • 2013
  • In the sewage structures and wastewater facilities, concrete is exposed to hydrogen sulfide ($H_2S$) which acts as an acid material in a solution, and a strongly acidic sulfate ion ($SO{_4}^{-2}$) is generated by a sulfuric bacteria. Hence, a degradation of concrete with biochemical corrosion would be accelerated. Finally, durability of concrete and concrete structures may be greatly reduced. In this study, in order to remove the hydrogen sulfide which is used by the sulfuric bacteria organic-biologically, the antibiotic metal and metallic salt powders were mixed to concrete, and a suppressing performance of the sulfate ion was assessed. For the sulfuric acid bacteria, a comparative evaluation of antimicrobial performance on neutralized concrete specimens were carried out, also by a rapid chloride penetration test, chloride penetration depths and diffusion coefficients were measured for antibiotic concrete in accordance with the amount of metal and metallic salt-based antibacterial agents. Eventually, by an observation of the biochemical state of the surface of concrete specimens exposed outdoors, the performance and applicability of antibiotic concrete were confirmed.

A Study on the Applicability of Water-soluble Decontaminant to the Contaminated Aircraft Using SEM/EDS analysis (SEM/EDS 분석을 통한 수용성 제독제의 오염 항공기 적용 가능성 연구)

  • Kim, Jae-Kyun;Kim, Ik-Sik;Shin, Ki-Su
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.48-54
    • /
    • 2008
  • Biochemical weapons, called as a poor nation's nuclear-weapon, are most favorable Weapons of Mass Destruction(WMD). At the beginning of war, these biochemical weapons, which can threaten the operations of our forces and cause the anxiety and chaos of people, should be used to attack our principle facilities. And these attacks might be conducted as a long term scenario over the war. Consequentially, our military training as well as civilian-military joint training have been focused on these circumstances to improve defense capability against the invasion of biochemical weapons. Add to these efforts, there have been a lot of researches to develop advanced decontaminations that can secure our troops and equipments. In this study, applicability of the water-soluble decontaminant for the contaminated aircraft was evaluated. The water-soluble decontaminant has been applied to the military stations and ground weapon systems only. According to the theoretical analyses and published papers, the water-soluble decontaminant has been shown better decontamination capability than commercial cleaner by roughly 50%. Furthermore, as a result of experiment efforts in this study, it was showed that the water-soluble decontaminant can reduce corrosion risk which is primary concern for the aircraft structures.

A Study on the Surface-Treatment Agent as Concrete Repair Materials (콘크리트 보수재료로서 도포형 표면강화물질 검토)

  • 김도겸;고경택;김성욱;류금성;이장화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.497-502
    • /
    • 2001
  • We examined the silicate-based material to develop the surface-treatment agent, which would be used to restore performance of the deteriorated concrete and to inhibit corrosion of the reinforcing bar. As a part of the study, we carried out experiments of the penetration and strengthening properties of concrete treated by the considering agent. The variables of experiment, were the type of silicates, the ratio of distilled water-silicate, the usage of surface-strengthening material, and the usage of biochemical material. The penetrating ability of concrete is assessed by viscosity and surface tension. Also assessments of strengthening effects of concrete are performed on compressive strength, absorption, and water permeability tests.

  • PDF

An Experimental Study on the Fundamental Properties of. Sewage Concrete Covered with Inorganic and Complex Antibiotics (무기계 항균제 및 유$\cdot$무기계 복합 항균제를 도포한 하수시설 콘크리트의 기초물성에 관한 실험적 연구)

  • Lee Eui-Bae;Lee Dong Heck;Na Chul Sung;Khil Bae Su;Kim Gyu Yong;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.499-502
    • /
    • 2005
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, physical properties such as bond strength, resistance to abraision, water absorption and air permeability of concrete covered with inorganic and complex antibiotics were investigated.

  • PDF

Antibacterial Performance of Inorganic Liquified Antibiotics for antibacterial Concrete used in Sewage Facilities (하수시설에 사용되는 항균 콘크리트용 무기계 액상 항균제의 항균성능)

  • Kim Do Su;Khil Bae Su;Kim Gyu Yong;Lee Seung Hoan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.49-52
    • /
    • 2005
  • This study was performed to evaluate antibacterial performance antibiotics(RCF-95, Antibio-C) which could control biochemical corrosion of concrete used sewage facilities by sulfate oxidizing bacteria. As antibacterial methods, Broth MIC testing was used for investigating controlled growth effect of sulfate oxidizing bacteria. Also, color-changed testing by indicator was used for confirming between $H_{2}SO_{4}$ diffusion rate by bacteria and antibiotics. It confirmed that Antibio-C was superior to RCF-95 in the antibacterial performance and hence anticipated that this developed Antibio-C was enough to replace imported antibiotics from Japan.

  • PDF