• 제목/요약/키워드: Bio-signal Analysis

검색결과 175건 처리시간 0.027초

New Methodology to Develop Multi-parametric Measure of Heart Rate Variability Diagnosing Cardiovascular Disease

  • Jin, Seung-Hyun;Kim, Wuon-Shik;Park, Yong-Ki
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제3권2호
    • /
    • pp.17-24
    • /
    • 2005
  • The main purpose of our study is to propose a new methodology to develop the multi-parametric measure including linear and nonlinear measures of heart rate variability diagnosing cardiovascular disease. We recorded electrocardiogram for three recumbent postures; the supine, left lateral, and right lateral postures. Twenty control subjects (age: $56.70{\pm}9.23$ years), 51 patients with angina pectoris (age: $59.98{\pm}8.41$ years) and 13 patients with acute coronary syndrome (age: $59.08{\pm}9.86$ years) participated in this study. To develop the multi-parametric measure of HRV, we used the multiple discriminant analysis method among statistical techniques. As a result, the multiple discriminant analysis gave 75.0% of goodness of fit. When the linear and nonlinear measures of HRV are individually used as a clinical tool to diagnose cardiac autonomic function, there is quite a possibility that the wrong results will be obtained due to each measure has different characteristics. Although our study is a preliminary one, we suggest that the multi-parametric measure, which takes into consideration the whole possible linear and nonlinear measures of HRV, may be helpful to diagnose the cardiovascular disease as a diagnostic supplementary tool.

  • PDF

범죄의 두려움에 대한 자극의 유형에 따른 ERP 변화 분석 (An Analysis on the Changes in ERP According to Type of Stimuli about Fear of Crime)

  • 김용우;강행봉
    • 한국멀티미디어학회논문지
    • /
    • 제20권12호
    • /
    • pp.1856-1864
    • /
    • 2017
  • The ultimate goal of multimedia in bio-signal research is to approach multimedia contents through bio-signal. Hence it is important to interpret user's emotions by analyzing his or her bio-signals. In this paper, we construct ERP task of oddball component to analyze EEG signal between normal stimuli and fear stimuli and measure EEG during ERP task. The results from extracted ERP component show that there is a difference in N200 in visual stimuli, P300 in auditory stimuli, and N100 and P300. Moreover, there are larger changes in audiovisual stimuli, indicating that users recognize greater fear of crime when visual and auditory stimuli are simultaneously presented.

생체 신호를 활용한 영아 돌연사 알람 시스템 (Alarm System for Sudden Infant Death using Bio-Signals)

  • 윤수정;인치호
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.197-202
    • /
    • 2016
  • 본 논문에서는 영아 돌연사를 방지하기 위해 영아의 생체신호를 분석하여 위험상황이 발생했을 때 보호자에게 위험신호를 알려주는 영아 돌연사 모니터링 시스템을 제안한다. 영아 돌연사(SID)는 생후 한 달에서 일년 사이의 건강한 아기가 원인불명으로 사망하는 것을 말한다. 제안한 영아 돌연사 모니터링 시스템은 생체신호를 센싱하는 부분과 생체 신호를 처리하는 프로세서부와 모니터링 및 알람부분으로 구성된다. PPG 센서를 사용하여 생체신호를 센싱하고 프로세서부에서는 센서를 통해 획득한 신호를 동잡음을 제거하여 부모에게 알람 및 모니터링 할 수 있게 하였다. 제안한 시스템은 영아의 심박동을 분석하여 위험상황인 경우 보호자에게 모니터링 및 경고 알람을 보내게 된다. 시스템의 실제 구현을 통해 모니터링 시스템의 성능을 평가하였다.

인터렉티브 스쿼트운동기구의 설계방법에 관한 연구 (A Study of the design method for Interactive squat exercise Instrument)

  • 정병호;박주훈;김지원
    • 한국융합학회논문지
    • /
    • 제9권2호
    • /
    • pp.303-311
    • /
    • 2018
  • 스쿼트운동은 안전하고 효과적인 운동성과를 기대할 수 있는 중요한 프리웨이트운동의 하나로 하체강화운동에 가장 효과적인 운동으로 알려져 있다. 인터렉티브 스쿼트운동 장치를 활용하여 동적인 운동과정을 단순화하여 스쿼트 운동 동작을 모델링하고 이를 기반으로 한 생체신호 및 동작 분석을 수행할 수 있으며 또한 장치를 통해 사용자 자세교정을 통해 올바르고 효과 높은 스쿼트운동 과정을 확립할 수 있다. 제안된 모델링을 기반으로 설계된 풋플레이트에 위치한 로드셀의 검출된 신호를 활용하여 스쿼트동작을 생체신호검출과 검출된 신호처리과정을 거쳐 스쿼트운동의 오류동작을 검출해 내는 신호출력을 확보할 수 있다. 본 논문에서 제안된 인터랙티브 스쿼트운동장치의 설계방법과 동작의 안전성 분석방법은 생체역학 신호처리 방법에 기인하며 사용자의 스쿼트 운동자세를 해석을 위한 검출된 생체신호 및 동작신호를 통해 올바르지 못한 스쿼트 동작을 교정함으로서 바른 스쿼트 운동을 유도할 수 있으며 연구 결과를 VR 장치에 적용하거나 운동 평가를 위한 장치로 활용할 수 있다.

위전도 계측시스템의 개발 (Development of Electrogastrography System)

  • 한완택;김인영;김원기;박기원;김희찬;손정일;이풍렬;이종철
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.403-406
    • /
    • 1997
  • Electrogastrogaphy(EGG) is the technique by which gastric myoelectrical activity is recorded noninvasively, from electrodes on the abdominal skin. Despite many attempts made over the decades, the clinical application of the EGG signal has not improved to the identification of waveform characteristics using comparison of EGG signal to be detected other EGG system. Cutaneous measurements of EGG are yet to be standardized in methods of detection and analysis. This may be responsible in part for some of the variability in the results. Thus, we develope EGG system composed of amplifiers, analysis methods, patient database or standardization. we introduce configurations of EGG system and their functions. Several important EGG parameters are introduced, including the dominant frequency and power of the EGG, the relative, period EGG-dominant frequency and power, the instability coefficient of EGG-dominant frequency and power, standard deviation, the percentage of running spectrum activity of gastric slow waves.

  • PDF

수면 분석을 위한 다중 모달 생체신호 측정 시스템 (Multimodal Bio-signal Measurement System for Sleep Analysis)

  • 김상규;유선국
    • 한국멀티미디어학회논문지
    • /
    • 제21권5호
    • /
    • pp.609-616
    • /
    • 2018
  • In this paper, we designed a multimodal bio-signal measurement system to observe changes in the brain nervous system and vascular system during sleep. Changes in the nervous system and the cerebral blood flow system in the brain during sleep induce a unique correlation between the changes in the nervous system and the blood flow system. Therefore, it is necessary to simultaneously observe changes in the brain nervous system and changes in the blood flow system to observe the sleep state. To measure the change of the nervous system, EEG, EOG and EMG signal used for the sleep stage analysis were designed. We designed a system for measuring cerebral blood flow changes using functional near-infrared spectroscopy. Among the various imaging methods to measure blood flow and metabolism, it is easy to measure simultaneously with EEG signal and it can be easily designed for miniaturization of equipment. The sleep stage was analyzed by the measured data, and the change of the cerebral blood flow was confirmed by the change of the sleep stage.

부정맥 신호의 조기진단을 위한 연속 심전도 모니터링 기기 개발 (Development of Continuous ECG Monitor for Early Diagnosis of Arrhythmia Signals)

  • 최정현;강민호;박준호;권기구;배태욱;박준모
    • 융합신호처리학회논문지
    • /
    • 제22권2호
    • /
    • pp.45-50
    • /
    • 2021
  • 최근 IT기술이 발달함에 따라 다양한 생체신호 측정 기기에 대한 연구 및 관심이 높아지고 있으나, 가장 대표적인 생체 신호 중 하나인 심전도, 특히 부정맥 신호 검출과 관련한 연구는 미비한 현실이다. 부정맥은 그 발병원인이 다양하며 발병이후 예후가 좋지 않으므로 조기진단을 통한 예방치료가 최선이다. 하지만 부정맥을 진단하기 위한 도구인 24시간 홀터 심전계는 사용지속시간의 제약, 일상생활로 인한 동잡음 분석의 어려움, 위험상황에서 사용자의 실시간 알람 기능에 단점을 보인다. 본 연구에서는 장시간 연속 측정이 가능한 심전도 및 맥박 모니터링 기기와 실시간 모니터링 앱, 분석용 소프트웨어를 개발하였으며, 측정한 값의 경향성을 확인하였다. 향후 연구에서는 심전도 신호 측정 분석의 정량적 결과 도출에 관한 연구가 필요하며, 이를 바탕으로 하는 부정맥 신호 검출 알고리즘 개발과 관련한 추가 연구를 진행해야 한다.

Analysis of Secretion Behavior of Human Lysozyme from Recombinant Saccharomyces cerevisiae

  • MARTEN, MARK R.;NAM SOO HAN;JIN BYUNG PARK;JIN-HO SEO
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권5호
    • /
    • pp.576-581
    • /
    • 1999
  • Effects of signal sequences, protein sizes and dissolved oxygen on the secretion of human lysozyme from a recombinant yeast were experimentally characterized. The systems consisted of Saccharomyces cerevisiae host SEY2102 that was transformed with two different plasmids. These plasmids were identical with an exception to the plasmid pMC614, which contained the native yeast MFα1 sequence and the plasmid pMC632 with the non-native rat α-amylase signal sequence. The expression of human lysozyme was controlled by the ADHI promoter. The native yeast MFαl signal sequence was more efficient than the non-native rat α-amylase signal sequence in directing the secretion of human lysozyme. Lysozyme secreted with the α-amylase signal was retained inside the cells and released to the medium very slowly, thereby causing a lower cell growth rate and a decreased product secretion rate. Lysozyme was secreted more efficiently than invertase, which is an order of magnitude bigger in molecular size compared to lysozyme, which was under the direction of the MFαl signal sequence, suggesting that protein sizes may affect the secretion efficiency. When expressed in anaerobic conditions in the medium where the ADHI promoter was derepressed, the amount of lysozyme secreted was about twice higher than that of the aerobic culture. However, the secretion rates were identical. This result showed that the dissolved oxygen level may affect the efficiency of protein secretion only, and not the secretion rate of the product protein.

  • PDF

신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현 (Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis)

  • 김성철
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5403-5408
    • /
    • 2012
  • 본 논문에서는 신체 성분 분석을 위한 다주파수 생체전기 임피던스 분석법에 대하여 소개하고 이를 기반으로 다주파수 생체전기 임피던스 분석 시스템을 구현하고 그 과정 및 결과를 제시하였다. 시스템의 구성요소들을 다주파수 교류 신호 발생부, 위상 신호 검출부, 전압 신호 검출부, 제어부, 입 출력부, 전극부, 전원부로 구분하여 설명하고, 구체적으로 구현 기법을 소개하였다. 체성분 데이터의 임상적 의의를 검토하고자 세계 최고 수준의 기술을 적용하여 높은 재현도와 고정밀도의 데이터를 제공하는 전문가용 체성분 분석기로 측정한 데이터와 비교 검토하고 두 측정치간의 상관관계를 구한 결과 시스템에 의한 체성분 분석은 상당히 높은 재현성을 나타낸다고 할 수 있다.

열차 시뮬레이터 조작 시 운전자의 생체신호 변화에 대한 연구 (A Study on Driver's Physiological Response in Train Simulator)

  • 장혜연;장재호;김태식;한창수;한정수;안재용
    • 대한인간공학회지
    • /
    • 제25권4호
    • /
    • pp.129-135
    • /
    • 2006
  • he purpose of this study is to measure bio-signal to investigate the driver's physiological response change under real situation using train simulator. The train simulator used in this study is KTX model and according to changes of driving situation, The bio-signal controlled by autonomic nervous system, such as GSR(Galvanic Skin Response), SpO2(Saturation percent O2), HR(Heart Rate), ECG(Electrocardiograph), EEG(Electroencephagram) and movement and response of eye were measured. Statistically significant difference in bio-signal data and eye movement activity pattern were investigated under several different driving speeds using analysis of variance (p<0.05). The GSR and HR value measured in average and mission speed operation is higher than in high-speed operation. β wave of EEG in average speed operation become more activated than in high speed operation. In accordance with a characteristic of rail vehicle, movement and response of eye in high-speed operation requiring relatively simple maneuver become less activated than in either average or mission speed operations. Conclusively, due to more careful driving controls in average and mission speed operation are required than in high-speed operation, level of mental and physical stresses of train driver was increased and observed through changes of bio-signal and eye movement measured in this study.