잉크젯 프린팅 기술을 이용한 플렉서블 온·습도센서 개발 (Fabrication of Flexible Temperature & Humidity Sensor Using Inkjet-printing Technology)

  • 계지원;한동철;신한재;김헌곤;이왕훈
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.119-123
    • /
    • 2015
  • This paper presents the inkjet-printed flexible temperature and humidity sensor(F-TH sensor) using PEDOT:PSS. The series, mesh and parallel type sensing element using PEDOT:PSS ink was printed on the overhead projector(OHP) film. The fabricated sensor of each structure has the temperature sensitivity of $140{\Omega}/^{\circ}C$, $29{\Omega}/^{\circ}C$ and $1.4{\Omega}/^{\circ}C$ with linearity, respectively. Also the fabricated sensor was not only possible to measure a temperature, but also to detect humidity. The humidity sensitivity of $400{\Omega}/%RH$, $3.4{\Omega}/%RH$ and $3{\Omega}/%RH$ with linearity, respectively. The fabricated F-TH sensor is expected for the various applications such as electronic devices, bio-healthcare, industrial field.

볼로미터형 테라헤르츠 센서의 광학적 특성 연구 (Optical Characteristics of Bolometric Terahertz Sensor)

  • 한명수;송우섭;홍정택;이동희
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.335-339
    • /
    • 2018
  • The optical characteristics of a terahertz (THz) antenna-coupled bolometer (ACB) detector were evaluated using a pulsed quantum cascade laser (QCL) and radiation blackbody sources. We investigated a method for measuring the responsivity and noise-equivalent power (NEP) of the THz detector using two different types of light sources. When using a QCL source with a frequency of 3 THz, the average responsivity of 24 devices was $1.44{\times}10^3V/W$ and the average NEP of those devices was $3.33{\times}10^{-9}W/{\surd}Hz$. The average responsivity and NEP as measured by blackbody source were $1.79{\times}10^5V/W$ and $6.51{\times}10^{-11}W/{\surd}Hz$, respectively, with the measured values varying depending on the light source. This was because the output power of each light source was different, with the laser source being driven by a pulse type wave and the blackbody source being driven by a continuous wave. The power input to the THz sensor was also different. Futhermore, the responsivity and NEP values measured using band pass filter (BPF) were similar to those measured when using only THz windows. It was found that ACB sensor responds normally in the THz region to both the laser and the blackbody source, and the method was confirmed to effectively evaluate the characteristics of the THz sensor.

무선 센서망에서 생체시스템 기반의 전송노드 선택 및 다중 채널 전송 알고리즘 (Bio-inspired Node Selection and Multi-channel Transmission Algorithm in Wireless Sensor Networks)

  • 손재현;양윤기;변희정
    • 인터넷정보학회논문지
    • /
    • 제15권5호
    • /
    • pp.1-7
    • /
    • 2014
  • 무선센서 네트워크(WSNs)는 일반적으로 수많은 센서노드들이 배치되어 데이터를 전송하며, 불필요한 데이터 전송으로 인해 에너지 낭비를 초래한다. 기존의 연구들은 주로 에너지 소모문제를 해결하는데 집중되었다. 하지만 실시간으로 정보전송이 필요한 어플리케이션에 대해서는 지연 보장 역시 고려되어야 한다. 본 논문은 생체시스템을 모방하여 무선센서망에서 에너지의 소모와 연시간을 줄이기 위한 BISA(Bio-inspired Scheduling Algorithm)를 제안한다. BISA는 에너지 효율성이 높은 라우팅경로를 탐색하고 다중채널을 이용해 데이터 전송경로를 다중화함으로써 데이터 전송을 위한 에너지소모와 지연시간을 최소화한다. 실험결과를 통해 제안한 알고리즘의 기존방식 보다 적은 에너지를 사용하며 동시에 요구지연 시간을 보장함을 확인한다.

RF 통신을 이용한 동물 생체정보 센싱 시스템 개발 (Implementation of Bio-information Sensing System using RF Communication)

  • 서용배;정중수
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1180-1185
    • /
    • 2009
  • 정보 콘텐츠 기술의 발달로 인하여 모든 정보들이 데이터베이스화 되어가고 있다. 하지만 아직 가축의 생체정보의 데이터베이스 구축은 생체정보의 수집단계의 어려움으로 그 발전이 미약하다. 본 논문은 젖소의 생체정보를 수집 관리하기 위하여 지그비 RF(Radio frequency)통신을 이용한 가축의 생체정보의 수집을 통해 젖소들의 생체상태를 센싱 할 수 있는 시스템을 개발하였고 이를 데이터베이스 구축에 활용하기 위한 논문이다. 센싱 시스템은 8Bit 마이크로 컨트롤러와 기울기센서, 온도센서, RF 모듈로 구성되었다.

  • PDF

농업기계 내비게이션을 위한 INS/GPS 통합 연구 (Study on INS/GPS Sensor Fusion for Agricultural Vehicle Navigation System)

  • 노광모;박준걸;장영창
    • Journal of Biosystems Engineering
    • /
    • 제33권6호
    • /
    • pp.423-429
    • /
    • 2008
  • This study was performed to investigate the effects of inertial navigation system (INS) / global positioning system (GPS) sensor fusion for agricultural vehicle navigation. An extended Kalman filter algorithm was adopted for INS/GPS sensor fusion in an integrated mode, and the vehicle dynamic model was used instead of the navigation state error model. The INS/GPS system was consisted of a low-cost gyroscope, an odometer and a GPS receiver, and its performance was tested through computer simulations. When measurement noises of GPS receiver were 10, 1.0, 0.5, and 0.2 m ($1{\sigma}$), RMS position and heading errors of INS/GPS system at 5 m/s straight path were remarkably reduced with 10%, 35%, 40%, and 60% of those obtained from the GPS receiver, respectively. The decrease of position and heading errors by using INS/GPS rather than stand-alone GPS can provide more stable steering of agricultural equipments. Therefore, the low-cost INS/GPS system using the extended Kalman filter algorithm may enable the self-autonomous navigation to meet required performance like stable steering or more less position errors even in slow-speed operation.

토양 물리성 측정을 위한 디지털 장치 개발(I) - 디지털 전단저항 측정장치 - (Development of a Digital Device for Measuring Soil Physical Properties (I) - Digital Shear Stress Sensor -)

  • 박준걸;이규승;조성찬;이동훈;장영창;노광모
    • Journal of Biosystems Engineering
    • /
    • 제33권6호
    • /
    • pp.416-422
    • /
    • 2008
  • This study was performed to design and construct a digital soil shear stress sensor in order to replace the conventional devices for measuring soil shear property. The developed digital shear stress measuring device can store measured data with GPS position information as a vector format into a computer. Based on the experiments at various field conditions, the measuring characteristic of the device was quite similar to that of a conventional device, SR-2 that has been a major tool to measure the soil shear property. It was concluded that the digital shear stress measuring device was an effective and comprehensive sensor for measuring soil shear property.

생체자기 신호측정을 위한 고인덕턴스 코일 내장형 온칩 자기센서 (On-chip Magnetic Sensor with Embedded High Inductance Coil for Bio-magnetic Signal Measurement)

  • 류현준;최준림
    • 전자공학회논문지
    • /
    • 제50권6호
    • /
    • pp.91-98
    • /
    • 2013
  • 생체자기신호 측정을 위해 고인덕턴스 코일과 계측 증폭기를 내장한 자기센서칩을 $0.18{\mu}m$ CMOS공정으로 제작하였다. 생체자기신호를 측정하기 적합한 감도와 대역폭을 가지는 고인덕턴스 코일센서를 전자기장 시뮬레이션 프로그램으로 설계하였으며, 온칩에 구현하기 위해 트렌스컨덕턴스 감쇄방법 적용한 low gm OTA를 구현하였다. 자기센서칩의 출력신호 감도는 $3.25fT/{\mu}V$이며, output reference noise는 21.1fT/${\surd}$Hz이다. 계측 증폭기부분은 current feedback 기반으로 설계되었으며, 자기 신호 잡음을 줄이기 위해서 0.5~5kHz의 대역의 BPF를 설계하였다. MPW칩 테스트에서 common mode rejection ratio(CMRR)는 117.5dB로 측정하였으며, input reference noise가 $0.87{\mu}V$ 이하로 유지되도록 설계하였다.

Characteristics of Protein G-modified BioFET

  • Sohn, Young-Soo
    • 센서학회지
    • /
    • 제20권4호
    • /
    • pp.226-229
    • /
    • 2011
  • Label-free detection of biomolecular interactions was performed using BioFET(Biologically sensitive Field-Effect Transistor) and SPR(Surface Plasmon Resonance). Qualitative information on the immobilization of an anti-IgG and antibody-antigen interaction was gained using the SPR analysis system. The BioFET was used to explore the pI value of the protein and to monitor biomolecular interactions which caused an effective charge change at the gate surface resulting in a drain current change. The results show that the BioFET can be a useful monitoring tool for biomolecular interactions and is complimentary to the SPR system.

The Interaction of CO to the Co(salen) Complex in to PEDOT:PSS Film and Sensor Application

  • Memarzadeh, Raheleh;Panahi, Farhad;Javadpour, Sirus;Ali, Khalafi-Nezhad;Noh, Hui-Bog;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권4호
    • /
    • pp.1297-1302
    • /
    • 2012
  • The interaction between carbon monoxide (CO) and a cobalt-salen complex (Co(salen)) was studied and applied to detect CO. The metal complex doped PEDOT:PSS film exhibited good sensitivity to CO and differentiate CO from other gases. The response of the composite to CO was reversible (RSD < 5%) change in resistance upon removal of CO gas from the test chamber. The effects of adding Co(salen) in the probe film on the response of the sensor were investigated using AFM, XPS, and FT-IR spectroscopy. The sensitivity of the sensor increased as the Co(salen) concentration enhanced as it increased from 0.0 to 1.5 wt. %, where the highest sensitivity ($%{\Delta}R/R_o$) of $-25.0{\pm}0.05%$ was achieved with 1.0 wt. % Co(salen). The sensor containing probe exhibited a linear response ($R^2$ = 0.983) in the range of 0.5 to 10.0% CO (v/v) $N_2$, and the detection limit was 1.74% CO (v/v) in $N_2$.