• Title/Summary/Keyword: Bio-Sensing

Search Result 217, Processing Time 0.032 seconds

A microfluidic multiple bio-analysis platform based on the enzyme-immobilized barcoded strip

  • Kim, Sung-Rak;Lee, Sang-Hoon
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.159-162
    • /
    • 2005
  • In this paper, we report a novel technique for the manufacture of polymeric bar-coded strips having diverse characteristics such as sensing with biocatalysts using a microfluidic platform and 'on the fly' photopolymerization. This method is a very simple, cost-effective means for mass production, and diverse materials sensitive to hazardous environments such as enzymes, DNA, or antigens are expected to be immobilized stably, as the fabrication process does not need any hazardous environments. On the basis of this technology, we fabricated enzyme-immobilized barcoded strip for multiple bio-analysis.

  • PDF

Development of Motion Mechanisms for Health-Care Riding Robots (지능형 헬스케어 승마로봇의 모션 메카니즘 개발)

  • Kim, Jin-Soo;Lim, Mee-Seub;Lim, Joon-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1735-1736
    • /
    • 2008
  • In this research, a riding robot system named as "RideBot" is developed for health-care and entertainments. The developed riding robot can follow the intention of horseman and can simulate the motion of horse. The riding robot mechanisms are used for many functions of attitude detection, motion sensing, recognition, common interface and motion-generations. This riding robot can react on health conditions, bio-signals and intention informations of user. One of the objectives of this research is that the riding robot could catch user motion and operate spontaneous movements. In this paper, we develope the saddle mechanism which can generate 3 degrees-of-freedom riding motion based on the intention of horseman. Also, we develope reins and spur mechanism for the recognition of the horseman's intention estimation and the bio-signal monitoring system for the health care function of a horseman. In order to evaluate the performance of the riding robot system, we tested several riding motions including slow and normal step motion, left and right turn motion.

  • PDF

Bio-inspired self powered nervous system for civil structures

  • Shoureshi, Rahmat A.;Lim, Sun W.
    • Smart Structures and Systems
    • /
    • v.5 no.2
    • /
    • pp.139-152
    • /
    • 2009
  • Globally, civil infrastructures are deteriorating at an alarming rate caused by overuse, overloading, aging, damage or failure due to natural or man-made hazards. With such a vast network of deteriorating infrastructure, there is a growing interest in continuous monitoring technologies. In order to provide a true distributed sensor and control system for civil structures, we are developing a Structural Nervous System that mimics key attributes of a human nervous system. This nervous system is made up of building blocks that are designed based on mechanoreceptors as a fundamentally new approach for the development of a structural health monitoring and diagnostic system that utilizes the recently developed piezo-fibers capable of sensing and actuation. In particular, our research has been focused on producing a sensory nervous system for civil structures by using piezo-fibers as sensory receptors, nerve fibers, neuronal pools, and spinocervical tract to the nodal and central processing units. This paper presents up to date results of our research, including the design and analysis of the structural nervous system.

Inorganic Materials and Process for Bioresorbable Electronics

  • Seo, Min-Ho;Jo, Seongbin;Koo, Jahyun
    • Journal of Semiconductor Engineering
    • /
    • v.1 no.1
    • /
    • pp.46-56
    • /
    • 2020
  • This article highlights new opportunities of inorganic semiconductor materials for bio-implantable electronics, as a subset of 'transient' technology defined by an ability to physically dissolve, chemically degrade, or disintegrate in a controlled manner. Concepts of foundational materials for this area of technology with historical background start with the dissolution chemistry and reaction kinetics associated with hydrolysis of nanoscale silicon surface as a function of temperature and pH level. The following section covers biocompatibility of silicon, including related other semiconductor materials. Recent transient demonstrations of components and device levels for bioresorbable implantation enable the future direction of the transient electronics, as temporary implanters and other medical devices that provide important diagnosis and precisely personalized therapies. A final section outlines recent bioresorbable applications for sensing various biophysical parameters, monitoring electrophysiological activities, and delivering therapeutic signals in a programmed manner.

Transient Receptor Potential Channels and Metabolism

  • Dhakal, Subash;Lee, Youngseok
    • Molecules and Cells
    • /
    • v.42 no.8
    • /
    • pp.569-578
    • /
    • 2019
  • Transient receptor potential (TRP) channels are nonselective cationic channels, conserved among flies to humans. Most TRP channels have well known functions in chemosensation, thermosensation, and mechanosensation. In addition to being sensing environmental changes, many TRP channels are also internal sensors that help maintain homeostasis. Recent improvements to analytical methods for genomics and metabolomics allow us to investigate these channels in both mutant animals and humans. In this review, we discuss three aspects of TRP channels, which are their role in metabolism, their functional characteristics, and their role in metabolic syndrome. First, we introduce each TRP channel superfamily and their particular roles in metabolism. Second, we provide evidence for which metabolites TRP channels affect, such as lipids or glucose. Third, we discuss correlations between TRP channels and obesity, diabetes, and mucolipidosis. The cellular metabolism of TRP channels gives us possible therapeutic approaches for an effective prophylaxis of metabolic syndromes.

Digital Olfactory Based Dementia Screening and Cognitive Enhancer Content (후각 바이오 정보 기반 치매 가상증강콘텐츠 기술 동향)

  • Choi, J.W.;Chang, S.J.;Bang, J.H.;Lee, H.R.;Kim, J.S.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.4
    • /
    • pp.89-97
    • /
    • 2019
  • The olfactory bio technology is largely based on its corresponding recognition technology and smell stimulus that acquires, analyzes, and processes volatile organic compounds present in chemical molecules, which are present in the breath or air evoked by an electronic nose artificially imitating the human biological nose. The olfactory bio technology is also based on a scent display technology that automatically diverges various digital flavors based on aesthetics, concentration, duration, and intensity information required to enhance the sensibility using a computer. Recently, attempts have been made to apply noninvasive screening of dementia by sensing, analyzing, encoding, and transmitting bio information obtained through an olfactory interface, both domestically and externally; further, the olfactory medical content technology has been applied to delay or reduce the onset of dementia. In this study, we will focus on early screening of dementia using olfactory biology information and dementia cognitive enhancer content that delays or reduces the onset of dementia.

Portable Amperometric Perchlorate Selective Sensors with Microhole Array-water/organic Gel Interfaces

  • Lee, Sang Hyuk;Kim, Hyungi;Girault, Hubert H.;Lee, Hye Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2577-2582
    • /
    • 2013
  • A novel stick-shaped portable sensing device featuring a microhole array interface between the polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel and water phase was developed for in-situ sensing of perchlorate ions in real water samples. Perchlorate sensitive sensing responses were obtained based on measuring the current changes with respect to the assisted transfer reaction of perchlorate ions by a perchlorate selective ligand namely, bis(dibenzoylmethanato)Ni(II) (Ni(DBM)2) across the polarized microhole array interface. Cyclic voltammetry was used to characterize the assisted transfer reaction of perchlorate ions by the $Ni(DBM)_2$ ligand when using the portable sensing device. The current response for the transfer of perchlorate anions by $Ni(DBM)_2$ across the micro-water/gel interface linearly increased as a function of the perchlorate ion concentration. The technique of differential pulse stripping voltammetry was also utilized to improve the sensitivity of the perchlorate anion detection down to 10 ppb. This was acquired by preconcentrating perchlorate anions in the gel layer by means of holding the ion transfer potential at 0 mV (vs. Ag/AgCl) for 30 s followed by stripping the complexed perchlorate ion with the ligand. The effect of various potential interfering anions on the perchlorate sensor was also investigated and showed an excellent selectivity over $Br^-$, $NO_2{^-}$, $NO_3{^-}$, $CO{_3}^{2^-}$, $CH_3COO^-$ and $SO{_4}^{2^-}$ ions. As a final demonstration, some regional water samples from the Sincheon river in Daegu city were analyzed and the data was verified with that of ion chromatography (IC) analysis from one of the Korean-certified water quality evaluation centers.

Investigation of Feasibility of Tunneling Field Effect Transistor (TFET) as Highly Sensitive and Multi-sensing Biosensors

  • Lee, Ryoongbin;Kwon, Dae Woong;Kim, Sihyun;Kim, Dae Hwan;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.141-146
    • /
    • 2017
  • In this letter, we propose the use of tunneling field effect transistors (TFET) as a biosensor that detects bio-molecules on the gate oxide. In TFET sensors, the charges of target molecules accumulated at the surface of the gate oxide bend the energy band of p-i-n structure and thus tunneling current varies with the band bending. Sensing parameters of TFET sensors such as threshold voltage ($V_t$) shift and on-current ($I_D$) change are extracted as a function of the charge variation. As a result, it is found that the performances of TFET sensors can surpass those of conventional FET (cFET) based sensors in terms of sensitivity. Furthermore, it is verified that the simultaneous sensing of two different target molecules in a TFET sensor can be performed by using the ambipolar behavior of TFET sensors. Consequently, it is revealed that two different molecules can be sensed simultaneously in a read-out circuit since the multi-sensing is carried out at equivalent current level by the ambipolar behavior.

Reduced Graphene Oxide Field-effect Transistor as a Transducer for Ion Sensing Application

  • Nguyen, T.N.T.;Tien, Nguyen Thanh;Trung, Tran Quang;Lee, N.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.562-562
    • /
    • 2012
  • Recently, graphene and graphene-based materials such as graphene oxide (GO) or reduced graphene oxide (R-GO) draws a great attention for electronic devices due to their structures of one atomic layer of carbon hexagon that have excellent mechanical, electrical, thermal, optical properties and very high specific surface area that can be high potential for chemical functionalization. R-GO is a promising candidate because it can be prepared with low-cost from solution process by chemical oxidation and exfoliation using strong acids and oxidants to produce graphene oxide (GO) and its subsequent reduction. R-GO has been used as semiconductor or conductor materials as well as sensing layer for bio-molecules or ions. In this work, reduced graphene oxide field-effect transistor (R-GO FET) has been fabricated with ITO extended gate structure that has sensing area on ITO extended gate part. R-GO FET device was encapsulated by tetratetracontane (TTC) layer using thermal evaporation. A thermal annealing process was carried out at $140^{\circ}C$ for 4 hours in the same thermal vacuum chamber to remove defects in R-GO film before deposition of TTC at $50^{\circ}C$ with thickness of 200 nm. As a result of this process, R-GO FET device has a very high stability and durability for months to serve as a transducer for sensing applications.

  • PDF