• Title/Summary/Keyword: Bio Sensor

Search Result 593, Processing Time 0.025 seconds

RFID-based Medicine Logistics System for Quick Response in Hospital (병원내 신속 대응을 위한 RFID 기반의 의약품 물류 시스템)

  • Lee, Kang-Dae;Lee, Young-Ho;Kang, Un-Gu;Chung, Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.10
    • /
    • pp.1-10
    • /
    • 2008
  • The traditional barcode based medicine logistics system have the problems such as loss, management error, online track, public information due to the hand-operated logistic process. Otherwise, quick response allows that the company observe the requests consistently and design medicine and establish manufacture schedule rapidly so that they could prohibit the product stocked. In this paper, we analyzed how to process medicine circulation logistics and information steps practically and proposed the RFID based medicine logistics system for the quick response in hospital. The proposed method provided the medical history tracing service, the traditional system connection, the efficiency logistic service, and the narcotic specified management service using the medicine logistics information from RFID tag. Accordingly, the satisfaction and the productivity will be improved the efficient medicine logistics by reducing the loss as well as the management error.

A Review Study of Biosensors applicable to Wellness Wear (웰니스 의류에 적용 가능한 바이오센서 동향 연구)

  • Kim, Hyo-Jin
    • Journal of Digital Convergence
    • /
    • v.15 no.11
    • /
    • pp.231-243
    • /
    • 2017
  • This paper provides a review of the electrical sensing biosensors and examine research cases of biosensors based on clothing and textiels. A biosensor which can measure bio-signals is a device that senses the physical and chemical characteristics of biological materials by using biological sensing materials. Therefore, wellness wear that is closely integrated with the user's real life will play an important role in achieving U-Health. The biosensors' unique feature which can be differentiated from the existing sensors is it's using of selective reactions and binding of biological substances. The electrical sensing biosensors are very small in size due to the processing of electrical signals, which can be used to create ubiquitous. Therefore, it is necessary to study electrical sensing biosensors that are easy to miniaturize to develop wellness wear. This paper describes the electrical sensing biosensor (an electrochemical method nanowire/carbon nanotube FET method) in detail. Finally, the future direction of biosensors to be applied to wellness wear is suggested.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

Inference of Sequencing Batch Reactor Process using Oxidation Reduction Potential (ORP profile을 이용한 연속 회분식 반응기(Sequencing Batch Reactor)에서 무산소공정 추론)

  • Sim, Mun Yong;Bu, Gyeong Min;Im, Jeong Hun;U, Hye Jin;Kim, Chang Won
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.245-250
    • /
    • 2004
  • The SBR(Sequencing Batch Reactor) process is ideally suited to treat high loading wastewater due to its high dilution rate. SBR operates by a cycle of periods consisting of filling, reacting, settling, decanting and idling. The react phases such as aeration or non-aeration, organic oxidation, nitrification, denitrification and other bio-logical reactions can be achieved in a reactor. Although the whole reactions can be achieved in a SBR with time distributing, it is hard to manage the SBR as a normal condition without recognizing a present state. The present state can be observed with nutrient sensors such as ${NH_{4}}^{+}-N$, ${NO_{2}}^{-}-N$, ${NO_{3}}^{-}-N} and ${PO_{4}}^{ 3-}-P.$ However, there is still a disadvantage to use the nutrient sensors because of their high expense and inconvenience to manage. Therefore, it is very useful to use common on-line sensors such as DO, ORP and pH, which are less expensive and more convient. Moreover, the present states and unexpected changes of SBR might be predicted by using of them. This study was conducted to get basic materials for making an inference of SBR process from ORP(oxidation reduction potential) of synthetic wastewater. The profiles of ORP, DO, and pH were under normal nitrification and denitrification were obtained to compare abnormal condition. And also, nitrite and nitrate accumulation were investigated during reaction of SBR. The bending point on ORP profile was not entirely in the low COD/NOx ratio condition. In this case, NOx was not entirely removed, and minimum ORP value was presented over -300mV. Under suitable COD/NOx ratio which complete denitrification was achieved, ORP bending point was observed and minimum ORP value was under -300m V. Under high COD/NOx ratio, ORP bending point was not detected at the first subcycle because of the fast denitrification and minimum ORP value was under -300mV at the time.

A Study on the Implementation of Mobile Healthcare System using Hybrid App (하이브리드 앱을 이용한 모바일 헬스케어 시스템 구현에 관한 연구)

  • Cho, Yang-Hyun;Kim, Sung Wan;Jeong, Pil-Seong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.503-514
    • /
    • 2013
  • Mobile Healthcare is a new type of health care services for managing health and life irrespective of time and space by uniting IT and BT. For this service bio-signal measurement using WBAN, and data analysis and monitoring technologies based on mobile devices are essential. Generally, however, mobile application has low compatibility because of the features of mobile platform, we have to redevelop it to support the corresponding platform. In this paper we introduce a Mobile Healthcare System which can function as gateway and monitoring based on hybrid app to create ubiquitous healthcare monitoring system compatible with various mobile devices by overcoming the difference of platforms. The proposed system consists of sensor composition part, monitoring composition part, and server composition part.

Investigation of Feasibility of Tunneling Field Effect Transistor (TFET) as Highly Sensitive and Multi-sensing Biosensors

  • Lee, Ryoongbin;Kwon, Dae Woong;Kim, Sihyun;Kim, Dae Hwan;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.141-146
    • /
    • 2017
  • In this letter, we propose the use of tunneling field effect transistors (TFET) as a biosensor that detects bio-molecules on the gate oxide. In TFET sensors, the charges of target molecules accumulated at the surface of the gate oxide bend the energy band of p-i-n structure and thus tunneling current varies with the band bending. Sensing parameters of TFET sensors such as threshold voltage ($V_t$) shift and on-current ($I_D$) change are extracted as a function of the charge variation. As a result, it is found that the performances of TFET sensors can surpass those of conventional FET (cFET) based sensors in terms of sensitivity. Furthermore, it is verified that the simultaneous sensing of two different target molecules in a TFET sensor can be performed by using the ambipolar behavior of TFET sensors. Consequently, it is revealed that two different molecules can be sensed simultaneously in a read-out circuit since the multi-sensing is carried out at equivalent current level by the ambipolar behavior.

Pre-processing of load data of agricultural tractors during major field operations

  • Ryu, Myong-Jin;Kabir, Md. Shaha Nur;Choo, Youn-Kug;Chung, Sun-Ok;Kim, Yong-Joo;Ha, Jong-Kyou;Lee, Kyeong-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • Development of highly efficient and energy-saving tractors has been one of the issues in agricultural machinery. For design of such tractors, measurement and analysis of load on major power transmission parts of the tractors are the most important pre-requisite tasks. Objective of this study was to perform pre-processing procedures before effective analysis of load data of agricultural tractors (30, 75, and 82 kW) during major field operations such as plow tillage, rotary tillage, baling, bale wrapping, and to select the suitable pre-processing method for the analysis. A load measurement systems, equipped in the tractors, were consisted of strain-gauge, encoder, hydraulic pressure, and radar speed sensors to measure torque and rotational speed levels of transmission input shaft, PTO shaft, and driving axle shafts, pressure of the hydraulic inlet line, and travel speed, respectively. The entire sensor data were collected at a 200-Hz rate. Plow tillage, rotary tillage, baling, wrapping, and loader operations were selected as major field operations of agricultural tractors. Same or different farm works and driving levels were set differently for each of the load measuring experiment. Before load data analysis, pre-processing procedures such as outlier removal, low-pass filtering, and data division were performed. Data beyond the scope of the measuring range of the sensors and the operating range of the power transmission parts were removed. Considering engine and PTO rotational speeds, frequency components greater than 90, 60, and 60 Hz cut off frequencies were low-pass filtered for plow tillage, rotary tillage, and baler operations, respectively. Measured load data were divided into five parts: driving, working, implement up, implement down, and turning. Results of the study would provide useful information for load characteristics of tractors on major field operations.

Strength analysis of mechanical transmission using equivalent torque of plow tillage of an 82 kW-class tractor

  • Kim, Taek-Jin;Kim, Wan-Soo;Kim, Yeon-Soo;Chung, Sun-Ok;Park, Seong-Un;Hong, Soon-Jung;Choi, Chang-Hyun;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.4
    • /
    • pp.723-735
    • /
    • 2019
  • The power-train is the most important component of an agricultural tractor. In this study, the strength of the driving gear transmission of an 82 kW-class tractor was analyzed using equivalent torque during plow tillage. The load measurement system consisted of an engine revolution speed sensor, torque-meters, revolution speed sensors for four axles, and pressure sensors for two hydraulic pumps. The load data were measured during plow tillage for four speed stages: F2 (2.78 km/h), F5 (5.35 km/h), F7 (7.98 km/h), and F8 (9.75 km/h). Aspects of the gear-strength such as bending stress, contact stress, and safety factors were analyzed under two torque conditions: the equivalent torque at the highest plow load for the F8 speed stage and the maximum engine torque. The simulation results using KISSsoft showed that the maximum engine torque conditions had a lower safety factor than did the highest equivalent torque condition. The bending safety factors were > 1 at all gear stages, indicating that gear breakage did not occur under actual measured operating conditions, nor under the maximum torque conditions. However, the equivalent torque condition in the contact stress safety factor was > 1, and the maximum torque condition was < 1 at the first gear pair. The method of analysis using the equivalent torque showed lower stress and higher safety factor than did the method using maximum torque. Therefore, when designing a tractor by applying actual working torque, equivalent torque method would support more reliable product development.

A Study on Walking Stabilization and Path Tracking of Biped Robot Using RFID (이족 보행 로봇의 보행 안정화 및 RFID를 이용한 경로 추종에 관한 연구)

  • Park, Jong-Han;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.51-56
    • /
    • 2013
  • In order to apply a biped robot in real world, the robot requires a robust walking and a function of localization, path planning and navigation. Recently, localization and path planning using RFID of mobile robot has been studying. However, when the biped robot walks, it has unstability and tends to leave the path. In the paper we propose a method of walking stabilization using FSR(Force Sensing Resistor), Gyro and accelerometer for the real biped robot. Also a path tracking algorithm using RFID sensor attached in robot's foot is proposed based on localization of the robot. The proposed algorithm is verified from walking experiments using real biped robot on uneven terrain and path tracking experiments on the RFID environments.

Determination of L-Asparagine Using Proteus mirabilis Bacterial Electrode (Proteus mirabilis 박테리아 전극을 이용한 L-Asparagine의 정량)

  • Ihn Gwon-Shik;Moo-Jeong Sohn
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.422-427
    • /
    • 1988
  • The bio-electrode for L-asparagine, excellent in the reproducibility of responsibility, has been constructed by immobilizing the bacterium Proteus mirabilis on an ammonia gas sensor. This electrode was investigated for the effects of pH, temperature, buffer solution, bacterial amounts and interferences, and stability with the lapse of time. The response of the bacterial electrode was linear in the range of $9.0{\times}10^{-5}$$1.0{\times}10^{-2}M$ L-asparagine with a slope of 58.9mV/decade in pH 7.8, 0.05M phosphate buffer solution at $30^{\circ}C$. The bacterial amounts used for this electrode was 3 mg and response time was 7∼9 min. Therefore, this assembly can be used for the determination of L-asparagine.

  • PDF