• Title/Summary/Keyword: Bio Radar

Search Result 24, Processing Time 0.031 seconds

A 2.4 GHz Bio-Radar System with Small Size and Improved Noise Performance Using Single Circular-Polarized Antenna and PLL (하나의 원형 편파 안테나와 PLL을 이용하여 소형이면서도 개선된 잡음 성능을 갖는 2.4 GHz 바이오 레이더 시스템)

  • Jang, Byung-Jun;Park, Jae-Hyung;Yook, Jong-Gwan;Moon, Jun-Ho;Lee, Kyoung-Joung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1325-1332
    • /
    • 2009
  • In this paper, we design a 2.4 GHz bio-radar system that can detect human heartbeat and respiration signals with small size and improved noise performance using single circular-polarized antenna and phase-locked loop. The demonstrated bio-radar system consists of single circular-polarized antenna with $90^{\circ}$ hybrid, low-noise amplifier, power amplifier, voltage-controlled oscillator with phase-locked loop circuits, quadrature demodulator and analog circuits. To realize compact size, the printed annular ring stacked microstrip antenna is integrated on the transceiver circuits, so its dimension is just $40\times40mm^2$. Also, to improve signal-to-noise-ratio performance by phase noise due to transmitter leakage signal, the phase-locked loop circuit is used. The measured results show that the heart rate and respiration accuracy was found to be very high for the distance of 50 cm without the additional digital signal processing.

Development of Doppler Radar Using Compact Dual-Circularly Polarized Antenna (소형 이중 원형편파 안테나를 이용한 도플러 레이다 개발)

  • Kim, Tae-Hong;Lee, Hyeonjin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.121-124
    • /
    • 2015
  • In this paper, we developed the compact Doppler radar using the compact dual-circularly polarized antenna for medical application. The operating frequency is 2.47 GHz for considering ISM band. In order to decrease the size of the entire system, we designed the compact antenna and located the circuit board at the back of the antenna. The simulation of the proposed antenna was performed by the finite difference time domain (FDTD) method. The total volume of the proposed system is $65{\times}45{\times}6mm^3$ including the antenna. From the experiment, the developed bio-radar could be used to support the device for medical applications.

A study on a target-tracking and noncontact type biosignal measurment system Using IR-Radar and Pan-Tilt system (원격 비접촉식 목표 추적형 생체신호측정시스템에 관한 연구)

  • Choi, Kwang-Wook;Kim, Cheol-Sung;Yang, Chul-Seung;Lee, Jeong-Gi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2237-2242
    • /
    • 2014
  • As Single households increases for reason of communication development, extending human life, there are many problems occuring all over the world. In order to solve this problem with an invasion of privacy and manintain a healthy life, this paper suggest non-contact type bio-signal measurement system using IR-Radar, displacement sensor and Pan-Tilt system. The proposed system can increse the distance of measured respiration from 1m to over 8m, which is comprised of two IR-Radar for location tracking, one displacement sensor for non-contact type bio-signal measurement and one stepping motor drive system. The proposed system is verified through experiments and were confirmed the possibility.

Wireless Bio-Signal Sensing System Using a Circular Polarized Antenna

  • Kwon Young-Bae;Park Jung-Min;Choe Jung-Hwan;Park Seong-Ook;Ishida Osami
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.3
    • /
    • pp.132-139
    • /
    • 2005
  • Wireless bio-signal sensing system, which is based on the principle of Doppler radar, can measure a respiration and heart rates with a periodic movement of skin and muscle near the heart. Though the sensing monostatic system using a circulator has been studied, this bistatic system can be improved by using a circular polarized antenna which has a high isolation between transmitter and receiver. In this paper, we measured the bio-signal without the direct contact with the person. The design of each system and experimental results are discussed.

A Six-port Bio Radar System for Non-Contact Measurement of Heart and Respiration (호흡 및 심박수 측정을 위한 비 접촉방식의 6-포트 바이오레이더 시스템)

  • Na, Won;Lee, Moon-Que
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1393-1394
    • /
    • 2008
  • 본 논문은 사람의 호흡과 심박 수를 0.5 m 의 거리에서 원격 측정하는 레이더 시스템 설계에 관한 내용을 기술한다. 기존에 많이 사용되었던 능동 주파수 혼합기 회로를 파형 간섭 효과를 이용한 6 -포트 회로로 대치하여 설계하였으며 특히 전력 검출기 성능에 따라 낮은 국부 발진기 전력을 사용할 수 있다는 장점을 가짐을 보였다. 본 논문에서는 수신신호 감지를 위한 최적의 국부 발진기의 전력을 제시하였다.

  • PDF

DSP Embeded Hardware for Non-contact Bio-radar Heart and Respiration Rate Monitoring System (DSP를 이용한 비 접촉식 도플러 바이오 레이더 생체신호 모니터링 시스템 임베디드 하드웨어의 개발)

  • Kim, Jin-Seung;Jang, Byung-Jun;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.97-104
    • /
    • 2010
  • In this paper, we provide an embedded type non-contact bio-radar heart and respiration rate monitoring system. We implemented the rate finding algorithm into the embedded system. The high-speed and reliable real-time signal processor is then tested. To avoid null-point data loss problem, we applied quadrature demodulation. Among several other combining techniques, we suggest arctangent demodulation for quadrature channel combining and DSP is used for real-time signal processing. We also suggest DC-offset compensation technique to preserve the wanted DC components of the IQ signals for accurate demodulation while keeping the dynamic range of the ADC lower. Using Texas Instrument C6711 series DSP and external 12Bit ADC, we implemented proper elliptic digital filter and autocorrelation detection algorithm for robust commercial hand held device.

Antenna sensor skin for fatigue crack detection and monitoring

  • Deshmukh, Srikar;Xu, Xiang;Mohammad, Irshad;Huang, Haiying
    • Smart Structures and Systems
    • /
    • v.8 no.1
    • /
    • pp.93-105
    • /
    • 2011
  • This paper presents a flexible low-profile antenna sensor for fatigue crack detection and monitoring. The sensor was inspired by the sense of pain in bio-systems as a protection mechanism. Because the antenna sensor does not need wiring for power supply or data transmission, it is an ideal candidate as sensing elements for the implementation of engineering sensor skins with a dense sensor distribution. Based on the principle of microstrip patch antenna, the antenna sensor is essentially an electromagnetic cavity that radiates at certain resonant frequencies. By implementing a metallic structure as the ground plane of the antenna sensor, crack development in the metallic structure due to fatigue loading can be detected from the resonant frequency shift of the antenna sensor. A monostatic microwave radar system was developed to interrogate the antenna sensor remotely. Fabrication and characterization of the antenna sensor for crack monitoring as well as the implementation of the remote interrogation system are presented.

Apnea Detection and Respiration Rate Estimation Using IR-UWB Radar Signals (IR-UWB 레이다 기반의 무호흡 검출 및 호흡수 측정)

  • Ko, Inchang;Park, Hyung Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.10
    • /
    • pp.802-809
    • /
    • 2017
  • This paper presents a novel apnea detection and respiration rate estimation method using impulse-radio ultra-wideband (IR-UWB) radar. The proposed method utilizes amplitude, time of arrival, and power in the selected band. The experimental results show that respiration rate can be estimated accurately using proposed method. And, it is shown that the selectivity between apnea and respiration can be improved more than 50 dB using the proposed method.

Algorithm for Air Conditioning Service Based on IR-UWB Sensor (IR-UWB 센서 기반의 에어컨 서비스 알고리즘)

  • Kim, Jong-Min;Kang, Tae-Hyung;Ryu, Gab-Sang
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.4
    • /
    • pp.1-7
    • /
    • 2021
  • Recently, technological differentiation(sensor, AI) of products using IoT technology to satisfy consumer needs in the mature market for smart home appliances has received a lot of positive responses. However, air conditioner products are in the early stages of convergence technology. Therefore, air conditioner products are fields that require ICT technologies for information production, collection, processing, storage, and service development beyond IoT. In this paper, we collect and store contactless bio-signal using IR-UWB radar technology. The blowing direction of the air conditioning is controlled according to bio-signal and user's sleep is monitored to provide an optimal sleep environment. In addition, we propose a service algorithm that can provide comfort with changes in the optimal conditions of air conditioning and emotional lighting depending on the discomfort index environment. Through this study, we developed an intelligent smart air conditioning service platform with ICT technology of bio-signal, discomfort index, and emotional lighting.

Angle-of-Arrival Estimation Algorithm Based on Combined Array Antenna

  • Kim, Tae-yun;Hwang, Suk-seung
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.2
    • /
    • pp.131-137
    • /
    • 2021
  • The Angle-of-Arrival (AOA) estimation in real time is one of core technologies for the real-time tracking system, such as a radar or a satellite. Although AOA estimation algorithms for various antenna types have been studied, most of them are for the single-shaped array antenna suitable to the specific frequency. In this paper, we propose the cascade AOA estimation algorithm for the combined array antenna with Uniform Rectangular Frame Array (URFA) and Uniform Circular Array (UCA), with the excellent performance for various frequencies. The proposed technique is consisted of Capon for roughly finding AOA groups with multiple signal AOAs and Beamspace Multiple Signal Classification (MUSIC) for estimating the detailed signal AOA in the AOA group, for the combined array antenna. In addition, we provide computer simulation results for verifying the estimation performance of the proposed algorithm.