• Title/Summary/Keyword: Binocular function

Search Result 70, Processing Time 0.021 seconds

Comparative Analysis of the Training Fidelity of Vision Training Trainee (시기능 훈련 대상자의 훈련 충실도 비교 분석)

  • Kim, Ki-Hong;Lee, Chang-Seon;Lee, Jae Yoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.47-51
    • /
    • 2009
  • Purpose: The purpose of this case study is to analyze of the training fidelity of vision training trainee. Mehtods: The vision training observation group included 75 clients (male=40, female=35) who had binocular vision disorders without opthalmic diseases or vertical phoria. Results: A high degree of visiting rate and training fidelity showed improvement of binocular vision function, sensation and symptoms. It had a high degree of success rate and preference rate. Conclusions: We suggest that high training fidelity is an effective and alternative method for binocular vision disorder therapy.

  • PDF

The Effect of Vision Training on Exophoria and Intermittent Extropia Using MYSTERY CIRCLE System (MYSTERY CIRCLE 시스템을 이용한 폭주부족형 사위 및 간헐성 사시 환자의 시기능 훈련 효과 연구)

  • Lee, Chang-Seon;Kim, Kun-Kyu;Jeon, Young-Ki;Kim, Kong-Ki;Choi, Chul-Hee;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effect of vision training using MYSTERY CIRCLE system on patients with exophoria and intermittent extropia. Mehtods: The vision training observation group consists of 26 clients who had exophoria (n=18) and intermittent extropia (n=8) without opthalmic diseases or vertical phoria. Our clients took each vision training once a week for eight weeks and were investigated for the symptoms changes of binocular vision. Results: According to the results, MISTERY CIRCLE vision training methods improved the binocular vision function and sensation symptoms. For Worth 4 Dot test, Titmus test and red lenses showed fusion rate changes. Conclusions: The study proved that MISTERY CIRCLE vision training system for patients with binocular vision was effective for the improvement of the binocular vision symptoms of these patients.

The Application of Accommodative Facility Test in Accommodation Assessment (조절평가시 조절용이성 검사의 적용)

  • Park, Hyun-Ju;Cho, Young-Rae;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.167-171
    • /
    • 2004
  • The accommodative facility test can be use the very benetit in visual function test. The purpose of this study was mainly to check the binocular function and to estimate the amount of accommodation with the hand held flipper. It was measured as the subjective time needed to clear an accommodative target (20/20 letters) at 40 em through +/-2.00 D flipper(Bernell Corp., USA). The subjects have an irrespective of sex and no eye disease. Seventy five of youth applicants participated for the accommodative facility test. The reagents using the flipper had higher expected value than the other reagents. In test for the binocular function, the accommodative facility test is a important part due to a serviceable and simple examination. Therefore, these binocular checkup have to be developed through a survey of normative value in the near future.

  • PDF

The Study on Effects of After Vision Training for Elementary School Children in Muan (무안군 소재 초등학생들의 시훈련 효과에 관한 연구)

  • Jang, Jung Un;Kim, In Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.137-142
    • /
    • 2013
  • Purpose: This study was designed to investigate the current status of visual acuity for elementary school students in Muan-gun and to analyze improvements of their visual function after vision training for the elementary school students who have either insufficiency of accommodation or vergence. Methods: Subjective refraction, objective refraction and binocular function were examined for 335 elementary school children from year 1 to year 6 live in Muan area, and then 47 students who have symptoms of binocular dysfunction among them were selected. We analyzed and compared between before and after vision training (VT) in binocular vision function results. Results: The results show that most of the subjects had much problem in near point convergence (NPC) than accommodation. After the vision training, the average of subjects NPC was improved about 5.93 cm, from $11.57 {\pm}1.850$ cm for before VT to $5.66{\pm}0.965$ cm for after VT. After VT positive fusional vergence at near distance after VT was $19.64{\pm}3.66$ $\Delta$, which was as much as double of near phoria. Accommodative amplitude was improved from $10.02{\pm}2.566$ D for before VT to $12.30{\pm}1.397$ D for after VT, which similar to mean of expected accommodative amplitude of 11.27 years old. Conclusions: Among insufficiency of accommodation and vergence NPC was improved specially, and accommodative facility and other ocular functions were also improved. Therefore, it is considered the vision training is very effective to recover from visual function problems.

The Change in Binocular Function and Sensory Anomaly After vision Training on Intermittent Exotropia and Recurrent Intermittent Exotropia Patients After Surgical Correction (간헐성 외사시 및 외사시 재발환자에 대한 시기능 훈련 후 양안시 기능 및 감각이상 변화)

  • Lee, Chang-Seon;Kim, Jong-Ki;Shin, Jeong-Hoon;Kim, Dae-Nyoun;Lee, Hyun Mee;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.345-350
    • /
    • 2011
  • Purpose: This was a study of the effects of the vision training on binocular function and sensory anomaly for intermittent exotropia and recurrent intermittent exotropia patients. Mehtods: The change was examined weekly at the clinic during the 8 week vision training. The sample group of 17 patients, intermittent exotropia and recurrent intermittent exotropia patients without amblyopia, were chosen from the patients with the short and the long-distance deviation angle p=0.558 and p=0.338, and also greater than 10${\Delta}$, respectively. Results: The longdistance deviation angle was reduced by 67.9(${\pm}$32.7)%, and the short-distance deviation angle by 75.4(${\pm}$32.9)% after the vision training. There is an improvement on the binocular function and sensory anomaly according to the fusion reverse and Worth 4 dot tests. Conclusions: This study shows that the vision training is effective for phoria, function and sensory anomalyon of the intermittent extropia and recurrent intermittent exotropia patients.

The Factors Influencing the Asthenopia of Myopia with Phoria (사위를 가진 근시안의 안정피로에 영향을 미치는 요인)

  • Kim, Jung-Hee;Kim, Chang-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.419-428
    • /
    • 2005
  • The aim of this study was to provide data for the relief of asthenopia during binocular vision by determining the characteristics of ocular function in adults. A total of 260 subjects were between the age of 19-35years. We measured individually the refractive error correction, pupillary distance, optical center distance, phoria, convergence, accommodation and the AC/A as well as the asthenopia during binocular vision using a questionnaire. After analysis of factors affecting asthenopia, we also examined the reductive effect of asthenopia in subjects who had asthenopia using prism. To determine the factors affecting asthenopia during binocular vision, statistic analyses were carried out the multivariate Logistic regression model. The results of this study were as follow. The asthenopia during binocular vision was found 26.9% of subjects. Multivariate logistic regression model was used to determine factors affecting binocular vision of myopia. When the accommodation and convergence were low compared to being high, when subjects had esophoria or there was more exophoria, and when AC/A was lower than the standard, the rate of asthenopia was higher. Therefore the accommodation, convergence and AC/A could be predictive factors for asthenopia. We used prism for subjects who had asthenopia during binocular vision, the results showed that the symptom of asthenopia was eased up to 74.3%.

  • PDF

Analysis of Binocular Vision by Wesson Fixation Disparity Card (Wesson Fixation Disparity Card를 이용한 양안시 분석)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • A commonly used device to determine fixation disparity curves is the Wesson Fixation Disparity Card. A fixation disparity curve is an x, y coordinate plot of the angular amount of fixation disparity as a function of the power of prisms through which the patient views. The fixation disparity curve variables that are used to aid in the diagnosis and management of binocular vision disorders include the x-intercept, y-intercept, curve slope and curve type. Fixation disparity curves were measured on 102 subjects with the Wesson fixation disparity card. The purpose of this study is to investigate distribution of the curve types obtained with Wesson card. Fixation Disparity by Wesson Fixation Disparity Card were that in case of type I 63.0%, in case of type II 0.0%, in case of type III 25.0% and in case of type IV 12.0%.

  • PDF

Phase Modulation effects on the imamging performance of the binocular objective having rotationally symmetrical aberrations (위상변조가 회전대칭적 수차를 갖는 쌍안경 결상력에 미치는 효과)

  • 홍경희;오병완;정창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.143-147
    • /
    • 1992
  • 1)iscussed in this paper are the effects of phase modulation on the line spread functions (LSF) and MTFs of ;I binocular objective system. The binocular objective lens is made in Korea. It has rotationally symmetric aberrations. The LSFs and MTFs are measured experimentally. The phase modulation is carried out by applying phase retardation $\pi$ on the aperture. The area where the phase is not retarded presents a double annular type. The OTF curves of phase modulated aperture are compared with that of unmodulated aperture. The comparison shows that there is the aberration compensation effect in aberration loaded system. Therefore the performance of many optical system can be improved without any loss of light energy by properly modulating the phase on the aperture.

  • PDF

Comparison of Binocular Function in Normal Subjects and Convergence Insufficiency (정상안과 폭주부족안의 양안시기능 검사값 비교)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.287-291
    • /
    • 2010
  • Purpose: The aim of this study was to compare binocular functions such as near point of convergence (NPC), AC/A ratios, heterophoria, accommodation, accommodation lag, positive relative accommodation (PRA), negative relative accommodation (NRA), positive relative convergence (PRC), negative relative convergence (NRC) in normal subjects and convergence insufficiency. Methods: 86 subject (male n=45, female n=41, mean $age{\pm}SD=23.27{\pm}2.85$ years) without amblyopia, strabismus, and ocular pathology were studied. Forty three patients each group were classified as normal subjects and convergence insufficiency group based on AC/A ratio and far and near phoria. Binocular function of the two groups was measured using phoropter. r. Results: The values between normal subjects and convergence insufficiency were 5.71 cm and 7.07 cm for NPC, 5.28 and 2.81 for Heterophria AC/A, 0.92 exo/3.36 exo and 2.17 exo/10.84 exo for far and near phoria, 15.49/23.30/13.30 and 13.50/20.02/9.09 for PRC, respectively. However, there were no significant differences between normal subjects and convergence insufficiency for accommodative amplitude, accommodative lag, PRA, NRA, BI vergence test, BO vergence test, NRC. Conclusions: Both groups were a significant difference for cover test, NPC, Heterophria AC/A, far and near phoria, break point of PRC, and recovery point of PRC.