• Title/Summary/Keyword: Binocular

Search Result 323, Processing Time 0.029 seconds

Comparison of Binocular Function and Surgical Outcomes of Tenacious Proximal Fusion and High Accommodative Convergence/Accommodation Ratio Types of Intermittent Exotropia

  • Park, Jun Woo;Lee, Soo Jung
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.483-487
    • /
    • 2018
  • Purpose: To compare the characteristics and surgical outcomes in patients with tenacious proximal fusion (TPF) and high accommodative convergence/accommodation ratio (AC/A) types of intermittent exotropia. Methods: This study retrospectively enrolled 40 patients with intermittent exotropia, 23 with TPF and 17 with high AC/A. Binocular function was evaluated by Worth's 4-dot test. Patients underwent lateral rectus recession, and surgical outcomes were compared. Surgical success was defined as less than ${\pm}10$ prism diopters (PD) at 12 months postoperatively. Results: The proportion of diplopia at near, evaluated by Worth's 4-dot test, was significantly higher in patients with high AC/A than in those with TPF (35.3% vs. 4.3%, p = 0.029). The mean preoperative angles of deviation in TPF and high AC/A types were $28.3{\pm}4.4$ and $28.8{\pm}4.5PD$ at distances, and $14.7{\pm}4.2$ and $15.1{\pm}4.1PD$ at near. Twelve months after surgery, the mean angles of deviation in TPF and high AC/A types were $2.9{\pm}9.8$ and $1.2{\pm}9.6PD$, respectively, at distance and $1.7{\pm}7.7$ and $-1.3{\pm}11.3PD$ at near. The surgical success rates were similar in the TPF and high AC/A types (74.0% vs. 64.7%). Five (21.7%) patients with TPF and 2 (11.8%) with high AC/A type experienced recurrence, with consecutive esotropia occurring in 1 (4.3%) patient with TPF and 4 (23.5%) patients with high AC/A. Conclusions: The proportion of diplopia at near was higher in patients with high AC/A type than in those with TPF intermittent exotropia. However, the surgical success rates were not significantly different between the types.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

Effect of Vision Training using Fresnel Prism Lens on Fusional Vergence and Accommodation (프레넬 프리즘렌즈를 이용한 시기능 훈련이 조절과 융합버전스에 미치는 영향)

  • Kim, Yong-Gil;Kim, Min-Kyung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • Purpose: Of the various methods of vision training, the essay aims to explore the effective ways of using the Fresnel prism lens in order to expand the positive fusional vergence for the patient having specific condition of convergence insufficiency or basic exophoria. Methods: 15 students of city of Daejeon university without an eye disease (average age $22.73{\pm}1.68$) were selected and underwent the subjective refraction test and binocular vision test, and recording their test results before vision training and replacing an identical frame with a lens of same quality after the full calibration, the lens was then adhered with the Fresnel prism lens and continued to train for thirty minutes daily during two weeks. Afterwards, the binocular vision test was reattempted. The observation of the change in the results of the binocular vision test in use of the fresnel prism lens in the vision training test was researched. Results: After training, the positive fusional vergence had increased to a number of $22.27{\pm}2.26$ $\Delta$, to 7.80 $\Delta$, at near, the fused cross cylinder test increased to an average of $0.55{\pm}0.09$ D, 0.40 D after training, showing a normal result. The value of negative relative accommodation after training had an average of $2.22{\pm}0.08$D, showing that 0.42 D had increased. The value of near point of convergence after training had an average of $6.13{\pm}0.53$ cm, showing that 2.80 cm had decreased. To patients who had convergence insufficiency or basic exophoria, the value of the near vision test that used the Fresnel prism lens which was able to expand BO positive fusional vergence had increased without phoria. Conclusions: The changes were tested and the effectiveness of the Fresnel prism lens, due to the nature of the lens itself, helped with both cosmetic effects and cost. It also allows good optical correction effects, in addition to these clinical effects indicated before. Therefore, it may be determined that the Fresnel prism lens binocular vision therapy for patients is more popular and highly recommended.

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

One Year Follow-up for Successfully Treated Children with Accommodative Dysfunction (조절이상이 성공적으로 치료된 어린이에 대한 1년 후의 추적검사)

  • Shin, Hoy Sun;Youk, Do Jin;Sung, Duk Yong;Park, Sang Chul;Lee, Sun Haeng
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.169-174
    • /
    • 2010
  • Purpose: The purpose of this study is to evaluate the long-term stability of the improved symptoms and accommodative functions after completion of accommodative therapy. Methods: Seven children (mean age${\pm}$SD: $12{\pm}1.41$ years) who were successfully treated with a vision therapy program for either accommodative insufficiency or infacility were followed for 1 year. The visual symptoms of the subjects were measured by the College of Optometrists in Vision Development Quality of Life (COVD-QOL) checklist, and this was followed by measurement of the monocular and binocular accommodative facility with ${\pm}2.00$ D flipper lens. Results: The mean visual symptoms at the 1 year follow-up examination ($15.14{\pm}8.59$) showed a small increase, but there was no significant difference (p=0.446) from post-therapy ($11.86{\pm}7.22$). There was small regression in the monocular (left eye, $13.86{\pm}3.93cpm$) and binocular ($11.14{\pm}3.13cpm$) accommodative facility at the 1 year follow-up examination, but there were no significant different from the monocular ($15.86{\pm}4.14cpm$, p=0.147) and binocular ($13.21{\pm}3.76cpm$, p=0.066) accommodative facility measurements at post-therapy. Also, every subject met the normative values of ${\geq}7$ cpm for monocular accommodative facility and ${\geq}5$ cpm for binocular accommodative facility in the long-term. Conclusions: There was long-term maintenance of the improved visual symptoms and accommodative functions, and so it is clear that the positive therapeutic effects persist with accommodative therapy.

Automatic Control of Horizontal-moving Stereoscopic Camera by Disparity Compensation

  • Kwon, Ki-Chul;Choi, Jae-Kwang;Kim, Nam;Young-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.150-155
    • /
    • 2002
  • Horizontally-moving method (HMM) stereoscopic camera has a liner relationship between ver-gence and focus control. We introduced the automatic control method for a stereoscopic camera system that uses the relationship between vergence and focus of an HMM stereoscopic camera. the Automatic control method uses disparity compensation of the acquired image pair from the stereoscopic camera. For faster extraction of disparity information, the proposed binocular dispar-ity estimation method by the one-dimensional cepstral filter algorithm would be investigated. The suggested system in this study substantially reduced the controlling time and error-ratio so as to make it possible to achieve natural and clear images.

Volumetric 3D Display System Based on Rotating Dot-Matrix LEDs

  • Lin, Yuanfang;Liu, Xu;Zhang, Xiaojie;Yao, Yi;Liu, Xiangdong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.440-441
    • /
    • 2004
  • A volumetric three-dimensional (3D) display system was presented, which utilizes a rotating two-dimensional (2D) display panel of light emitting diodes (LEDs) to generate more than 10 million volume pixels (voxels) within a cylindrical volume of 165 mm in height and 292 mm in diameter. Due to persistence of vision, momentarily addressed voxel information is perceived and fused into a 3D image. Important cues for depth perception, such as binocular parallax, accommodation, convergence and motion parallax are satisfied automatically and naturally, thus it is suitable for individual or group viewing, without the need for any special visual aids.

  • PDF

Real-Time Terrain Rendering Framework for GIS Applications

  • Kang, Dong-Soo;Lee, Eun-Seok;Shin, Byeong-Seok
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.2
    • /
    • pp.73-78
    • /
    • 2009
  • Real-time 3D visualization of terrain data is one of the important issues in GIS(Geographic Information System) field. We present a real-time terrain rendering engine that can use several types of GIS data source such as DEM(Digital Elevation Map), DTED(Digital Terrain Elevation Data) and LIDAR(Light Detection And Ranging). Our rendering engine is a quadtree-based terrain rendering framework with several acceleration modules. This can generate an ocular and binocular image. Also it can be applied to the flight simulation, walk-through simulation and a variety of GIS applications.

  • PDF

A Case of Human Thelaziasis Occurred in Both Eyes (양안에 발생한 동양안충증 1예)

  • 민홍기;전규식
    • Parasites, Hosts and Diseases
    • /
    • v.26 no.2
    • /
    • pp.133-136
    • /
    • 1988
  • On October 26, 1987, the authors encountered a case of human thelasiasis involving both eyes. The case in Chollapuk-do, Korea, a farmer aged 23, complained of mild lacrimation for 3 weeks followed by 1 week duration of foreign body sensation in both eyes prior to examination of eyes. The conjunctivae of both eyes appeared slightly reddened. No other abnormalities were noticed. Total 6 worms, one male and two females from each eye, were removed, parasitologically studied, and identified as Thelazia callipaeda Railliet and Henry, 1910.

  • PDF

Ergonomic evaluation of stereoscopic contents for a museum exhibition

  • Abe, N.;Ohta, K.;Kawai, T.;Ando, K.;Kakinuma, T.;Fujita, K.;Kudo, N.
    • Journal of Information Display
    • /
    • v.12 no.3
    • /
    • pp.159-165
    • /
    • 2011
  • This research entailed the production of stereoscopic 3D (S3D) contents using 2D-to-S3D conversion for exhibition at a museum and subjective evaluation. Hybrid production combining S3D images of existing live-action videos using the 2D-to-S3D conversion technology and computer graphic ones created via stereo rendering was conducted. Design and control of the chronological analysis of the parallactic angle was conducted on the produced contents, using binocular information as well as subjective evaluations, with the intent of conducting an investigation on the characteristics of such contents from the perspectives of the producers and viewers. An investigation was also conducted on the effects of the viewing position on the impressions of the S3D images.