• Title/Summary/Keyword: Biliary stent

Search Result 30, Processing Time 0.025 seconds

Biliary ascariasis misidentified as a biliary stent in a patient undergoing liver resection

  • Hochang Chae;Suk Won Suh;Yoo Shin Choi;Hee Ju Sohn;Seung Eun Lee;Jae Hyuk Do;Hyun Jeong Park
    • Parasites, Hosts and Diseases
    • /
    • v.61 no.2
    • /
    • pp.194-197
    • /
    • 2023
  • Ascaris lumbricoides causes one of the most common soil-transmitted helminthiases globally. The worms mostly infect the human small intestine and elicit negligible or nonspecific symptoms, but there are reports of extraintestinal ectopic ascariasis. We describe a rare case of biliary ascariasis mistaken for biliary stent in a 72-year-old female patient with a history of liver resection. She visited our outpatient clinic complaining of right upper quadrant pain and fever for the past week. She had previously undergone left lateral sectionectomy for recurrent biliary and intrahepatic duct stones 2 years ago. Besides mildly elevated gamma-glutamyl transferase levels, her liver function tests were normal. Magnetic resonance cholangiopancreatography revealed a linear filling defect closely resembling an internal stent from the common bile duct to the right intrahepatic bile duct. A live female A. lumbricoides adult worm was removed by endoscopic retrograde cholangiopancreatography (ERCP). Despite a significant decrease of the ascariasis prevalence in Korea, cases of biliary ascariasis are still occasionally reported. In this study, a additional case of biliary ascariasis, which was radiologically misdiagnosed as the biliary stent, was described in a hepatic resection patient by the worm recovery with ERCP in Korea.

Mechanical Property and Problems of the Self-expandable Metal Stent in Pancreaticobiliary Cancer

  • Thanawat Luangsukrerk
    • Journal of Digestive Cancer Research
    • /
    • v.10 no.2
    • /
    • pp.92-98
    • /
    • 2022
  • Self-expandable metal stent (SEMS) is effective for biliary drainage, especially in pancreaticobiliary cancer. The mechanical properties, material, and design of SEMS are important in preventing recurrent biliary obstruction and complication. Radial and chronic expansion forces play roles in preventing stent migration and collapse. Complications, such as stent impaction, cholecystitis, and pancreatitis, were related to the axial force. The nickel-titanium alloy shows more flexibility, conformability, and optimal axial force compared to previously used stainless steel. Additionally, the stent structure affected the mechanical properties of SEMS. Therefore, understanding the mechanical properties, material, and design of SEMS will provide the best outcome for biliary drainage, as well as better SEMS development.

Percutaneous Transhepatic Treatment of Benign Bile Duct Strictures Using Retrievable Covered Stents: Long-Term Outcomes in 148 Patients

  • Byung Soo Im;Dong Il Gwon;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.889-900
    • /
    • 2022
  • Objective: To investigate the long-term outcomes of percutaneous treatment of benign biliary strictures using temporary placement of a retrievable expanded polytetrafluoroethylene (PTFE) covered stent. Materials and Methods: We retrospectively analyzed the outcomes of 148 patients (84 male and 64 female; age range, 11-92 years) who underwent percutaneous transhepatic placement and removal of a retrievable PTFE-covered stent for the treatment of benign biliary strictures between March 2007 and August 2019 through long-term follow-up. Ninety-two patients had treatment-naïve strictures and 56 had recurrent/refractory strictures. Results: Stent placement was technically successful in all 148 patients. The mean indwelling period of the stent was 2.4 months (median period, 2.3 months; range, 0.2-7.7 months). Stent migration, either early or late, occurred in 28 (18.9%) patients. Clinical success, defined as resolution of stricture after completing stent placement and removal, was achieved in 94.2% (131 of 139 patients). The overall complication rate was 15.5% (23 of 148 patients). During the mean follow-up of 60.2 months (median period, 52.7 months; range, 1.6-146.1 months), 37 patients had a recurrence of clinically significant strictures at 0.5-124.5 months after removal of biliary stent and catheter (median, 16.1 months). The primary patency rates at 1, 3, 5, 7, and 10 years after removal of biliary stent and catheter were 88.2%, 70.0%, 66.2%, 60.5%, and 54.5%, respectively. In the multivariable Cox proportional hazard regression analysis, sex, age, underlying disease, relation to surgery, stricture type, biliary stones, history of previous treatment, and stricture site were not significantly associated with the primary patency. Conclusion: Long-term outcomes suggest that percutaneous treatment of benign biliary strictures using temporary placement of retrievable PTFE-covered stents may be a clinically effective method.

Comparison of Outcomes between 7-French and 10-French Plastic Stents for Patients with Biliary Tract Cancer (담도암 환자에서 7-프렌치와 10-프렌치 플라스틱 스텐트의 결과 비교)

  • Lee, Kyong Joo;Kang, Yong Seok;Seong, Jae Ho;Jung, Saehyun;Kim, Jae Woo
    • The Korean Journal of Pancreas and Biliary Tract
    • /
    • v.22 no.4
    • /
    • pp.165-171
    • /
    • 2017
  • Background/Aim: There is little data on whether plastic stents with a larger diameter are patent for longer than small stents in patients with bile duct cancer. The aim of this study was to compare the stent survival between 7-French (Fr) and 10-Fr plastic stents and evaluate the factors affecting stent survival. Methods: Patients with biliary obstruction due to biliary tract cancer were enrolled at Yonsei University Wonju College of Medicine from January 2010 to October 2014. Results: A total of 215 patients (7-Fr:10-Fr = 89:126 patients) were retrospectively enrolled. The primary tumor sites were common bile duct (n = 111), hilar (n = 45), and ampulla of Vater (n = 59). Rates of stent migration and stent obstruction were not different between the two groups. The median duration of stent survival was 3.3 months in the 7-Fr group and 5.9 months in the 10-Fr group (p = 0.543). The diameter of the stent did not have an effect on stent survival (hazard ratio 1.11, 95% confidence interval 0.71-1.73, p = 0.649). Conclusions: 7-Fr and 10-Fr stents have similar rates of stent migration and stent obstruction. The stent survival of 7-Fr was not inferior to 10-Fr stents in the management of biliary tract cancer.

Clinical Characteristics and Treatment Outcomes of Patients with Unresectable Cholangiocarcinoma in Thailand: Are there Differences Dependent on Stent Type?

  • Prachayakul, Varayu;Chaisayan, Suthasinee;Aswakul, Pitulak;Deesomsak, Morakod
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.529-532
    • /
    • 2013
  • Cholangiocarcinoma, though very rare in Western countries, is one of the commonest liver malignancies in Southeast Asia, especially in Thailand. More than half of the patients present with advanced stage disease. Given the poor treatment outcomes of adjuvant therapeutic options, many patients undergo only biliary drainage for palliative treatment. Clinical characteristics and treatment outcomes after biliary stenting were here analyzed for a total of 224 uresectable cholangiocarcinoma cases, 58.9% in men. The mean age was 61.5 years. Hilar involvement was the most common location. The patients underwent biliary drainage using plastic and metallic stents equally, early stent occlusion being encountered in 21.4% and 10.7%, respectively. The median survival time was 4.93 months for patients who received plastic and 5.87 months for patients who received metallic stents.

Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction

  • Yang, Min Jae;Kim, Jin Hong;Hwang, Jae Chul;Yoo, Byung Moo;Lee, Sang Hyub;Ryu, Ji Kon;Kim, Yong-Tae;Woo, Sang Myung;Lee, Woo Jin;Jeong, Seok;Lee, Don Haeng
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.722-727
    • /
    • 2018
  • Background/Aims: Although endoscopic bilateral stent-instent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Methods: Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Results: Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Conclusions: Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

A case report of gastrointestinal perforation in patient after biliary stent insertion and the overview of gastrointestinal perforation (담도 스텐트 시술 후 장천공 증례보고 및 장천공에 대한 고찰)

  • Ga-Young Lee;Chan-Ran Park;Jung-hyo Cho;Chang-gue Son;Nam-hun Lee
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.195-203
    • /
    • 2022
  • Objectives: This study aimed to emphasize the importance of accurate and timely diagnosis of acute abdominal pain with simple radiography by reporting a case of gastrointestinal perforation. Methods: We closely observed the diagnosis and progress of acute abdominal pain after biliary stent and reviewed the outline of gastrointestinal perforation. Results: Patient diagnosed with urethral cancer metastasis to lung and peritoneum was treated with complex Korean medicinal treatments to deal with anorexia, abdominal pain, jaundice and oliguria. During hospitalization, the patient's acute abdominal pain after biliary stent was diagnosed with gastrointestinal perforation by using plain chest and abdominal radiography. Conclusion: Using simple radiography to find out the emergency diseases such as perforation in acute abdominal pain is important clinically.

Septicemia Caused by Leuconostoc lactis with Intrinsic Resistance to Vancomycin in a Patient with Biliary Stent

  • Shin, Kyeong Seob;Han, Kyudong;Hong, Seung Bok
    • Biomedical Science Letters
    • /
    • v.19 no.3
    • /
    • pp.280-283
    • /
    • 2013
  • Leuconostoc spp. is intrinsically resistant against vancomycin and rarely causes the infection in immunocompromised patients. In this report, we describe a fatal case of Leuconostoc lactis bacteremia in a patient with biliary tract stent insertion to resolve the biliary tract obstruction by multiple pseudocysts in the pancreatic head region. Leuconostic lactis isolated from the blood of the patients was confirmed by 16S rRNA sequencing and this isolate was susceptible against most antibiotics, including levofloxacin, penicillin, erythromycin and cefotaxime except vancomycin. The septic shock and multi-organ failure was abruptly progressed due to delayed use of adequate antibiotic. Using vancomycin as the empirical antibiotics in a bacteremic patient by Gram positive cocci, the treatment failures by the isolates with intrinsic resistance against vancomycin have to be considered. In addition, the prompt and accurate identification of Leuconostoc spp. are very important to select the adequate antibiotics.

Transcatheter Intravascular Stent Placement in a Shih Tzu Dog with Refractory Pulmonic Stenosis (카테터를 통한 혈관스텐트 장착을 통한 심한 폐동맥협착증 치료 1례)

  • Kim, Hyun-Wook;Kim, Sung-Soo;Lee, Joon-Soek;Nam, So-Jeong;Choi, Ran;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.48-53
    • /
    • 2009
  • A 4-year-old intact male Shih Tzu dog (5.4 kg of body weight) was referred with primary complaints of heart murmur and exercise intolerance. Diagnostic studies found severe valvular pulmonic stenosis (peak velocity of 6.4 m/s, pressure gradient 165 mmHg). The dog was treated with 3 cm (length) ${\times}$ 1.5 cm (diameter) of Palmaz biliary stent. The outcome of stent placement was favorable and remarkably reduced the severity of PS (6.4 m/s to 3.0 m/s of peak velocity). Clinical condition was remarkably improved with the absence of cardiac murmur, although mild pulmonic regurgitation existed from the day of stent placement. To our best knowledge, this case is the first clinical trial for treating PS with intravascular stent in Korea.