• Title/Summary/Keyword: Bileaflet Mechanical Heart Valve

Search Result 27, Processing Time 0.026 seconds

Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves- (도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구-)

  • Jin, Seong-Hun;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF

Short and Intermediate Term Results of the ATS Heart Valve Replacement (ATS 인공 심장 판막의 단기 및 중기 임상성적)

  • Lim, Chang-Young;Moon, Seung-Chul;Yang, Jin-Young;Koo, Won-Mo;Kim, Dae-Sig;Lee, Gun;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

Low-intensity Oral Anticoagulation Versus High-intensity Oral Anticoagulation in Patients with Mechanical Bileaflet Prosthetic Heart Valves (이엽성 기게 심장판막 환자에 대한 낮은 강도의 항응고제 요법의 결과에 대한 임상분석)

  • Jeong, Seong-Cheol;Kim, Mi-Jung;Song, Chang-Min;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.430-438
    • /
    • 2008
  • Background: All the patients with mechanical valves require warfarin therapy in order to prevent them from developing thromboembolic complications. According to the ACC/AHA practice guidelines, after AVR with bileaflet mechanical prostheses in patients with no risk factors, warfarin is indicated to achieve an INR of 2.0 to 3.0. After MVR with any mechanical valve, warfarin is indicated to achieve an INR of 2.5 to 3.5. But in our clinical experience, bleeding complications (epistaxis, hematuria, uterine bleeding, intracerebral hemorrhage etc.) frequently developed in patients who maintained their INR within this value. So, we retrospectively reviewed the patients with bileaflet mechanical heart valve prosthesis and we determined the optimal anticoagulation value. Material and Method: From January 1984 to February 2007, 311 patients have been followed up at a national medical center. We classified the AVR patients (n=60) into three groups as follows: an INR from 1.5 to 2.0 in Group I, an INR from 2.0 to 2.5 in Group II and an INR from 2.5 to 3.0 in Group III. We classified the MVR (n=171) and DVR (n=80) patients into four groups as follows: an INR from 1.5 to 2.0 in Group I, an INR from 2.0 to 2.5 in Group II, an INR from 2.5 to 3.0 in Group III and an INR from 3.0 to 3.5 in Group III. We compared the groups for their thromboembolic and bleeding complications by means of the Kaplan Meier method. Result: In the AVR patients, 2 thromboembolic complications and 4 bleeding complications occurred and the log rank test failed to identify any statistical significance between the groups for thethromboembolic complication rate, but groups I and II had lower bleeding complication rates than did group III. Thirteen thromboembolic complication and 15 bleeding complication occurred in the MVR and DVR patients, and the log rank test also failed to identify statistical significance between the groups for the thromboembolic complication rate, but groups I and II had lower bleeding complication rates that did groups III and IV. Conclusion: The thromboembolic complication rate was not statistically different between groups I and II and groups III and IV, but the bleeding complication rates of groups I and II were lower than those of groups III and IV. So this outcome encouraged us to continue using our low intensive anticoagulation regime, that is, an INR of 1.5 to 2.5.

Clinical Evaluation of St.Jude Medical Valve Replacement (St.Jude 기계판막을 이용한 인공심장판막 치환의 외과적 고찰)

  • Jin, Ung;Rha, Suk-Joo;Cho, Kyu-Do;Kim, Chi-Kyung;Jo, Keon-Hyon;Wang, Young-Pil;Lee, Sun-Hee;Kwak, Moon-Sub;Kim, Se-Wha;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.27 no.4
    • /
    • pp.272-280
    • /
    • 1994
  • Total 400 St.Jude Medical Bileaflet Valves were implanted in 336 pts from January 1983 to June 1993; 64 were aortic, 205 were mitral, 64 were double valve and 3 were tricuspid position. The follow up period extended from 6 months to 10 years[mean 24.3 months]. Male to female ratio was 1:1.7. There were total 27 deaths[cardiac related 20, cardiac non-related 7]. Overall mortality was 2.9%/pt-yr. There were 10 early deaths[3.0%] and 10 late cardiac related deaths [3.0%]. Prosthetic valve related complications occurred in 19 patients[5.7%] and among them, seven died; four died of thromboembolic events, two died of anticoagulants therapy related hemorrhagic complications and one died of bacterial endocarditis. NYHA class improved significantly especially in aortic valve replacement and double valve replacement. In AVR cases, the mean NYHA was 2.8 preoperatively and 1.3 postoperatively. And in DVR cases, 3.3 preoperatively and 2.2 postoperatively. The decision to employ a particular prosthesis was made according to the anticipated or known complications of the valve. The St.Jude Medical Valve retains all the hazards of other mechanical valves, most notably, thromboembolism. But the hemodynamic performance of St.Jude Medical Valve compared most favorably with other substitute valves in many reports. 0ur experience didn`t show any differences compared other authors in terms of valve related complication. So we concluded St. Jude Medical Valve can be primarily considered in the selection of artificial valve except in the patients when the usage of anticoagulant therapy is contraindicated.

  • PDF

Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve (On-X 기계판막을 이용한 판막치환술의 단기성적분석)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.742-748
    • /
    • 2004
  • The On-X valve was recently introduced. It was the aim of this study to assess the safety and feasibility from the data derived from 28 patients who underwent aortic and/or mitral valve replacement with this prosthesis in National Medical Center. Material and Method: From May 1999 and May 2003, a series of 28 consecutive patients who had been implanted with 32 On-X prosthesis were reviewed, The operative procedure comprised of 12 MVR, 10 AVR and 6 DVR. The study followed the guidelines of AATS/STS. Mean follow-up was 27 months (total 04 patient-years). Result: Early ($\leq$30 days) mortality was 7.44% (2/28) and no late mortality occurred in the study. Total actuarial freedom from mortality at 2 years was 92.86$\pm$4.87% for all cases, 100% for MVR, 90$\pm$9.49% for AVR, and 83.3$\pm$1.52% for DVR. Thromboembolic event occurred in 2 MVR patients and that was the only complication; therefore, the linearized incidence of valve related complications was 3.17%/ patient-years for all cases and 6.5%/patient-years for MVR and the actuarial freedom from valve related complications at 2 years was 84.85$\pm$10.75%. Preoperatively, 24 (85.71%) patients were in NYHA functional class III or IV but postoperatively, 25 (89,29%) patients were in NYHA functional class I or II. The levels of hemoglobin, hematocrit, serum LDH, reticulocyte rate and indirect bilirubin were all within normal range at postoperative 3 month. In mitral position, the peak gradient was 6.1$\pm$1.8 mmHg and the mean gradient was 3.0$\pm$0.6 mmHg and EOA were 2.54$\pm$0.56 $m^2$, 2.39$\pm$0.73 $m^2$, 2.34$\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$ at 27 mm, 29 mm, 31 mm, 33 mm respectively. In aortic postion, the peak gradient was 21.1 $\pm$14.12 mmHg and the mean gradient was 12.3$\pm$6.52 mmHg. Conclusion: Since there was no significant difference in the postoperative mortality, valve related complications and echocardiographic hemodynamic data compared to standard bileaflet design and since there was an improvement in the NYHA functional class and normal values of hemolytic indicators, it can be assumed that On-X valve is safe and feasible. However, accumulation of cases and long-term follow-up of this patient group is needed to establish this result.

Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves (수종의 기계판막치환후 초음파심음향도를 이용한 판막간의 혈류역학적 비교)

  • Kang Joon Kyu;Hong Joon Hwa;Kim Hyung Tai;Park In Duk;Lee Cheol Joo
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.496-500
    • /
    • 2005
  • There was no difference between the bileaflet mechanical valves on the midterm and longterm clinical outcome. We reviewed the hemodynamic comparison between recently available mechanical valves by Doppler Echocardiography. Material and Method: We retrospectively reviewed 396 postoperative hemodynamic datas (EOA, MDPG, and MSPG) by doppler echocardiography in 345 patients. Mechanical valves from 5 venders (Sorin Bicarbon, SJM, ATS, On-X, and Edward MIRA) were compared. There were 232 valves in mitral position, 162 in aortic, and 2 in tricuspid. Result: There were 178 men (mean age; $50.6\pm13.9$ years old) and 167 women $(52.6\pm,4.6)$. MDPG/EOA of 27 mm in mitral position was Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$. In 29mm, Sorin, SJM, ATS, On-X, MIRA revealed $3.4\pm1.2/3.1\pm0.6,\;3.3\pm1.1/2.7\pm0.4,\;3.8\pm0.8/3.2\pm0.6,\;4.0\pm3.0/3.1\pm0.9,\;2.9\pm0.9/3.0\pm0.8$ In 31mm, Sorin, SJM, ATS, MIRA revealed $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$. In 33mm, Sorin, SJM, MIRA revealed $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$. MSPG/EOA of 19mm aortic position was Sorin, SJM, ATS, On-X, MIRA $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$ in that order. In 21mm, SJM, ATS, On-X, MIRA revealed $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$. In 23mm Sorin, SJM, ATS, On-X, MIRA revealed $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$. In 25mm, SJM and MIRA revealed $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$. There was no statistically significant difference in these values between the venders given the same position and size. 2 redo valve replacements were performed, 1 due to severe hemolysis in ATS and 1 due to leaflet immobilization in SJM. Conclusion: Postoperative hemodynamic comparison by doppler echocardiography shows no statistically significant difference between recently available mechanical valves in this country.