Browse > Article

Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves  

Kang Joon Kyu (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine)
Hong Joon Hwa (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine)
Kim Hyung Tai (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine)
Park In Duk (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine)
Lee Cheol Joo (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine)
Publication Information
Journal of Chest Surgery / v.38, no.7, 2005 , pp. 496-500 More about this Journal
Abstract
There was no difference between the bileaflet mechanical valves on the midterm and longterm clinical outcome. We reviewed the hemodynamic comparison between recently available mechanical valves by Doppler Echocardiography. Material and Method: We retrospectively reviewed 396 postoperative hemodynamic datas (EOA, MDPG, and MSPG) by doppler echocardiography in 345 patients. Mechanical valves from 5 venders (Sorin Bicarbon, SJM, ATS, On-X, and Edward MIRA) were compared. There were 232 valves in mitral position, 162 in aortic, and 2 in tricuspid. Result: There were 178 men (mean age; $50.6\pm13.9$ years old) and 167 women $(52.6\pm,4.6)$. MDPG/EOA of 27 mm in mitral position was Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$. In 29mm, Sorin, SJM, ATS, On-X, MIRA revealed $3.4\pm1.2/3.1\pm0.6,\;3.3\pm1.1/2.7\pm0.4,\;3.8\pm0.8/3.2\pm0.6,\;4.0\pm3.0/3.1\pm0.9,\;2.9\pm0.9/3.0\pm0.8$ In 31mm, Sorin, SJM, ATS, MIRA revealed $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$. In 33mm, Sorin, SJM, MIRA revealed $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$. MSPG/EOA of 19mm aortic position was Sorin, SJM, ATS, On-X, MIRA $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$ in that order. In 21mm, SJM, ATS, On-X, MIRA revealed $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$. In 23mm Sorin, SJM, ATS, On-X, MIRA revealed $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$. In 25mm, SJM and MIRA revealed $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$. There was no statistically significant difference in these values between the venders given the same position and size. 2 redo valve replacements were performed, 1 due to severe hemolysis in ATS and 1 due to leaflet immobilization in SJM. Conclusion: Postoperative hemodynamic comparison by doppler echocardiography shows no statistically significant difference between recently available mechanical valves in this country.
Keywords
Heart valve diseases; Heart valve, mechanical; Echocardiography;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Bonchek LI, Starr A. Ball valve prosthesis;Current appraisal of late results. Am J Cardiol 1975;35:843-54   DOI   ScienceOn
2 Kim HJ, Cho SJ, Ryu YJ, Cho WM, Son YS, Choi YH. Clinical Evaluation of the ATS Valve Replacement. Korean J Thorac Cardiovasc Surg 1997;30:293-9
3 Fiore AC, Barner HB, Swartz MT, et al. Mitral valve replacement: Randomized trial of St. Jude and Medtronic Hall prosthesis. Ann Thorac Surg 1998;66:707-13   DOI   ScienceOn
4 Kang MS, Yoo KJ, Yoon CS, Park HK. The Clinical ExPeriences of 'New Duromedics Valve' Replacement. Korean J Thorac Cardiovasc Surg 1997;30:979-85
5 Kang CH, Kim KH, Kim KB, Ahn H. Long-term Results after 1,144 Carbomedics Mechanical Valve Implantation. Korean J Thorac Cardiovasc Surg 2004;37:559-69
6 Bjornerheim R, Ihlen H, Simonsen S, Sire S, Svennevig J. Hemodynamic characterization of the Carbomedics mital valve prosthesis. J Heart Valve Dis 1997;6:115-22
7 Lee CJ, Choi H, Kim JT, Soh DM, Roh HK. Short Term Clinical Experiences of 52 Sorin Bicarbon Mechanical Valves. Korean J Thorac Cardiovasc Surg 1998;31:679-83
8 Jung SC, Kim IS, Kim WS, Shin YC, Yoo HK, Kim BY. Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve. Korean J Thorac Cardiovasc Surg 2004;37:742-8
9 Fraud S, Pethig K, Wahlers T, et al. On-X Bileaflet valve in aortic position-Early experience shows an improved hemodynamic profile. Thorac Cardiovasc Surg 1998;46:293-7   DOI   ScienceOn
10 Cho BK, Chang BC, Kang MS, Bang JH, Hong SN. Short- term and Intermediate-term Follow-up After Valve Replacement with the St.Jude Medical Prosthesis. Korean J Thorac Cardiovasc Surg 1992;25:57-65
11 Chambers J, Ely JL. Early postoperative echocardiographic hemodynamic performance of the On-X prosthetic heart valve. A multicenter study. J Heart Valve Dis 1998;7:569-73
12 Kim BY, Moon JH, Kang KH, Ahn WS, Lee JH, Ryu HS. ClinicAl Experience of Carbomedics Valve. Korean J Thorac Cardiovasc Surg 1994;27:995-1001
13 Carpenter A, Deloche A, Relland J, et al. Six-year follow-up of glutaraldehyde-preserved heterografts;with particular reference to the treatment of congenital valve malformations. J Thorac Cardiuovasc Surg 1974;68:771-82