Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves

수종의 기계판막치환후 초음파심음향도를 이용한 판막간의 혈류역학적 비교

  • Kang Joon Kyu (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine) ;
  • Hong Joon Hwa (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine) ;
  • Kim Hyung Tai (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine) ;
  • Park In Duk (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine) ;
  • Lee Cheol Joo (Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine)
  • 강준규 (아주대학교 의과대학 흉부외과학교실) ;
  • 홍준화 (아주대학교 의과대학 흉부외과학교실) ;
  • 김형태 (아주대학교 의과대학 흉부외과학교실) ;
  • 박인덕 (아주대학교 의과대학 흉부외과학교실) ;
  • 이철주 (아주대학교 의과대학 흉부외과학교실)
  • Published : 2005.07.01

Abstract

There was no difference between the bileaflet mechanical valves on the midterm and longterm clinical outcome. We reviewed the hemodynamic comparison between recently available mechanical valves by Doppler Echocardiography. Material and Method: We retrospectively reviewed 396 postoperative hemodynamic datas (EOA, MDPG, and MSPG) by doppler echocardiography in 345 patients. Mechanical valves from 5 venders (Sorin Bicarbon, SJM, ATS, On-X, and Edward MIRA) were compared. There were 232 valves in mitral position, 162 in aortic, and 2 in tricuspid. Result: There were 178 men (mean age; $50.6\pm13.9$ years old) and 167 women $(52.6\pm,4.6)$. MDPG/EOA of 27 mm in mitral position was Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$. In 29mm, Sorin, SJM, ATS, On-X, MIRA revealed $3.4\pm1.2/3.1\pm0.6,\;3.3\pm1.1/2.7\pm0.4,\;3.8\pm0.8/3.2\pm0.6,\;4.0\pm3.0/3.1\pm0.9,\;2.9\pm0.9/3.0\pm0.8$ In 31mm, Sorin, SJM, ATS, MIRA revealed $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$. In 33mm, Sorin, SJM, MIRA revealed $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$. MSPG/EOA of 19mm aortic position was Sorin, SJM, ATS, On-X, MIRA $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$ in that order. In 21mm, SJM, ATS, On-X, MIRA revealed $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$. In 23mm Sorin, SJM, ATS, On-X, MIRA revealed $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$. In 25mm, SJM and MIRA revealed $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$. There was no statistically significant difference in these values between the venders given the same position and size. 2 redo valve replacements were performed, 1 due to severe hemolysis in ATS and 1 due to leaflet immobilization in SJM. Conclusion: Postoperative hemodynamic comparison by doppler echocardiography shows no statistically significant difference between recently available mechanical valves in this country.

심장판막질환의 외과적 교정에 사용되는 수종의 기계판막들은 각기의 장점들을 주장하고 있으나, 중장기의 임상적 결과에는 유의한 차이를 보이지 않는다. 기계적 기능의 차이를 단순 비교하기는 어려우나 수술 후에 시행한 초음파심음향도로 측정한 판막간 압력차와 유효개구면적을 비교하여 다양한 기계판막들간의 기능을 비교하고자 한다. 대상 뜻 방법: 1995년부터 2003년 사이에 아주대학교병원 흥부외과에서 기계판막으로 치환술을 받았던 345명의 환자들에 사용되었던 396개의 기계판막을 대상으로 후향적 분석을 하였다. 사용되었던 판막으로는 Sorin Bicarbon, SJM, ATS, On-X, 그리고 Edward MRA로 5종류였다. 판막의 위치는 승모판막이 232개, 대동맥판막이 162, 그리고 삼첨판막이 2개였으며, 이중 다중판막치환술이 51예에서 있었다. 수술 후 14일이 지난 후에 시행한 초음파심음향도에서 유효개구면적, 수축기 평균압력차, 그리고 이완기 평균압력차를 지표로 통계학적인 비교분석을 하였다. 결과: 345명의 대상환자중 남자가 178명, 여자가 167이었고, 평균연령은 남자/여자가 $50.6\pm13.9/52.6\pm14.6$세였다. 승모판막의 경우 27mm에서는 MDPG/EOA가 Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$였으며, 31m에서는 Sorin, SJM, ATS, Mmh가 $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\p,0.2,\;3.7\pm1.5/2.7\pm0.7$ 였으며, 31mmdptjsms Sorin, SJM, ATS, MIRA가 $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$였으며, 33 m에서는 Sorin, SJM, MIRA가 $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$이었다. 대동맥판막의 경우 19mm에서 MSPG/EOA가 Sorin, SJM, ATS, On-X, MIRA가 $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$였으며, 21mm에서는 SJM, ATS, On-X, MIRA가 $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$였으며, 23 m에서는 Sorin, SJM, ATS On-X, MIRA가 $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$이었다 25mm에서는 SJM과 MIRA가 $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$이었다. 통계학적인 분석을 한 결과 같은 위치에 같은 크기의 판막들간에는 통계적으로 유의한 차이가 없었다. 판막재치환을 한 경우는 용혈로 인한 재치환이 ATS에서 1예, 판엽고정에 의한 재치환이 SJM에서 1예 있었다. 결론: 최근 국내에서 흔히 사용되고 있는 5종의 기계판막을 수술 후에 초음파심음향도로 추적조사한 결과 동일한 판막크기에서 각 판막간의 기능적 차이는 없는 것으로 조사되었다.

Keywords

References

  1. Bonchek LI, Starr A. Ball valve prosthesis;Current appraisal of late results. Am J Cardiol 1975;35:843-54 https://doi.org/10.1016/0002-9149(75)90121-6
  2. Carpenter A, Deloche A, Relland J, et al. Six-year follow-up of glutaraldehyde-preserved heterografts;with particular reference to the treatment of congenital valve malformations. J Thorac Cardiuovasc Surg 1974;68:771-82
  3. Cho BK, Chang BC, Kang MS, Bang JH, Hong SN. Short- term and Intermediate-term Follow-up After Valve Replacement with the St.Jude Medical Prosthesis. Korean J Thorac Cardiovasc Surg 1992;25:57-65
  4. Kim BY, Moon JH, Kang KH, Ahn WS, Lee JH, Ryu HS. ClinicAl Experience of Carbomedics Valve. Korean J Thorac Cardiovasc Surg 1994;27:995-1001
  5. Kang MS, Yoo KJ, Yoon CS, Park HK. The Clinical ExPeriences of 'New Duromedics Valve' Replacement. Korean J Thorac Cardiovasc Surg 1997;30:979-85
  6. Kim HJ, Cho SJ, Ryu YJ, Cho WM, Son YS, Choi YH. Clinical Evaluation of the ATS Valve Replacement. Korean J Thorac Cardiovasc Surg 1997;30:293-9
  7. Lee CJ, Choi H, Kim JT, Soh DM, Roh HK. Short Term Clinical Experiences of 52 Sorin Bicarbon Mechanical Valves. Korean J Thorac Cardiovasc Surg 1998;31:679-83
  8. Kang CH, Kim KH, Kim KB, Ahn H. Long-term Results after 1,144 Carbomedics Mechanical Valve Implantation. Korean J Thorac Cardiovasc Surg 2004;37:559-69
  9. Jung SC, Kim IS, Kim WS, Shin YC, Yoo HK, Kim BY. Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve. Korean J Thorac Cardiovasc Surg 2004;37:742-8
  10. Fiore AC, Barner HB, Swartz MT, et al. Mitral valve replacement: Randomized trial of St. Jude and Medtronic Hall prosthesis. Ann Thorac Surg 1998;66:707-13 https://doi.org/10.1016/S0003-4975(98)00670-5
  11. Fraud S, Pethig K, Wahlers T, et al. On-X Bileaflet valve in aortic position-Early experience shows an improved hemodynamic profile. Thorac Cardiovasc Surg 1998;46:293-7 https://doi.org/10.1055/s-2007-1010241
  12. Bjornerheim R, Ihlen H, Simonsen S, Sire S, Svennevig J. Hemodynamic characterization of the Carbomedics mital valve prosthesis. J Heart Valve Dis 1997;6:115-22
  13. Chambers J, Ely JL. Early postoperative echocardiographic hemodynamic performance of the On-X prosthetic heart valve. A multicenter study. J Heart Valve Dis 1998;7:569-73