• Title/Summary/Keyword: Bidirectional AC-DC converter

Search Result 57, Processing Time 0.02 seconds

A PCS Control Strategy for Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 하이브리드 ESS를 위한 PCS 제어전략)

  • Kim, Sang-Jin;Kwon, Min-Ho;Choi, Se-Wan;Paik, Seok-Min;Kim, Mi-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.302-311
    • /
    • 2016
  • This paper proposes a hybrid ESS that integrates an energy storage system (ESS) with an uninterruptible power supply (UPS). The hybrid ESS has a demand management and emergency power supply function while increasing the battery utilization of the UPS, which has just been used in a power failure. In addition to the critical load, the proposed system augments the capacity of emergency generation using an additional load, which has voltage and frequency-dependent characteristics to the grid side. The control algorithm of the AC-DC converter and bidirectional DC-DC converter is proposed for demand management and emergency power supply. Furthermore, seamless and autonomous transfer methods to alleviate the transient during mode transfer are proposed. To validate the proposed control scheme, experimental results from a 5 kW prototype are provided.

Stability Enhancement of a Hybrid Micro-grid System in Grid Fault Condition

  • Ambia, Mir Nahidul;Al-Durra, Ahmed;Caruana, Cedric;Muyeen, S.M.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.225-231
    • /
    • 2013
  • Low voltage ride through capability augmentation of a hybrid micro-grid system is presented in this paper which reflects enhanced reliability in the system. The control scheme involves parallel connected multiple ac-dc bidirectional converters. When the micro-grid system is subjected to a severe voltage dip by any transient fault single power converter may not be able to provide necessary reactive power to overcome the severe voltage dip. This paper discusses the control strategy of additional power converter connected in parallel with main converter to support extra reactive power to withstand the severe voltage dip. During transient fault, when the terminal voltage crosses 90% of its pre-fault value, additional converter comes into operation. With the help of additional power converter, the micro-grid system withstands the severe voltage fulfilling the grid code requirements. This multiple converter scheme provides the micro-grid system the capability of low voltage ride through which makes the system more reliable and stable.

A Study on the phase angle detection of power source for PWM converter based on PLL method (PLL기법에 기반한 PWM 컨버터 전원 위상각 검출에 관한 연구)

  • Choi Cheol;Lee Sang-Hun;Kim Cheol-U
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.284-288
    • /
    • 2005
  • This paper proposes the direct detection method of phase angle for the power source, which is based on the PLL method. The proposed method using a bidirectional photo-coupler is used to directly detect the zero crossing of phase voltage and calculate the angular frequency in the controller based on a M/T algorithm. Through the method, the additional installation space in the traditional method using a potential transformer can be minimized and it can be easy to design. The paper presents straightforward schematic circuits, design and experimental results.

  • PDF

Investigation of "Unified Voltage Conditioner - UVC"

  • Antchev, Mihail;Petkova, Mariya;Gourgoulitsov, Vanjo;Antchev, Hristo
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.357-362
    • /
    • 2012
  • In this paper, a power electronic converter which is composed of two converters - bidirectional AC/DC converter and Series Active Power Filter (SAPF), is discussed. Structural schemas and ways of operation of control systems of converters, which are used to eliminate non sinusoidal parts of the network source voltage, are presented. At the same time, the control used stabilizes the value of the voltage feeding the load. Taking in consideration the combined functions which the device executes, it may be called Unified Voltage Conditioner - UVC.

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

A Study of New Technique of Harmonic Elimination in Three-Phase Bridge AC/DC Converter (3상 브리지 AC/DC 컨버터의 고조파 저감에 대한 연구)

  • 김병진;문학룡;김준환;김상우;전희종
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.21-28
    • /
    • 1998
  • A new technique for shaping the line current and reducing the total hannonic distortion in a threephase rectifier is introduced. A review of the problems inherent in a three-phase diode rectifier feeding capacitive load and the possible solutions are first presented. The proposed 3 bidirectional switches and their operation are presented. The main features of this paper are low cost, high efficiency and simplicity. A simulation and experiment results show its good action.action.

  • PDF

Power Compensator Control for Improving Unbalanced Power of AC Electric Railway (교류전기철도 불평형 전력 개선을 위한 전력보상장치 제어)

  • Woo, Jehun;Jo, Jongmin;Lee, Tae-Hoon;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.213-218
    • /
    • 2020
  • In this study, we propose a control algorithm to reduce the unbalanced characteristics of a three-phase system power caused by the unbalanced load of the AC electric railway. Then, we verify its performance through the design of a power compensator and experiments applying it. Like electric railway systems, a Scott transformer is applied, and the load and single-phase back-to-back converters are connected to the M-phase and T-phase outputs. The back-to-back converter monitors the difference in active power between the unbalanced loads in real-time and compensates for the power by using bidirectional characteristics. The active power is performed through PI control in the synchronous coordinate system, and DC link overall voltage and voltage balancing control are controlled jointly by M-phase and T-phase converters to improve the responsiveness of the system. To verify the performance of the proposed power compensation device, an experiment was performed under the condition that M-phase 5 kW and T-phase 1 kW unbalanced load. As a result of the experiment, the unbalance rate of the three-phase current after the operation of the power compensator decreases by 58.66% from 65.04% to 6.38%, and the excellent performance of the power compensator proposed in this study is verified.