• 제목/요약/키워드: Biconical antenna

검색결과 27건 처리시간 0.027초

$SF_6$ 가스중 방전진전과정에 따른 방사전자파의 주파수 스펙트럼 분포 특성 (The Frequency Spectrum Characteristics of Radiated Electromagnetic Wave by the Process of Discharge Progress in $SF_6$)

  • 박광서;김해준;최병주;전영주;이동헌;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1747-1749
    • /
    • 2001
  • This paper simulated discharge progress and partial discharge using needle-plan electrodes system in $SF_6$, studied the distribution of frequency spectrum of the radiated electromagnetic waves using biconical antenna and spectrum analyzer. From results of this study, a method was introduced for measurement and analysis of the radiated electromagnetic waves in accordance with discharge progress in $SF_6$. Besides, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress in $SF_6$ can be possible.

  • PDF

액체질소중 정극성 직류방전시 방사전자파의 주파수 스펙트럼 특성 (The Frequency Spectrum Characteristics of the Radiated Electromagnetic Waves during Positive DC Discharge in Liquid Nitrogen)

  • 박광서;신호영;최병주;최상태;김기채;이광식;이동인
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.648-655
    • /
    • 1999
  • In this study, a relationship between DC discharge and the radiated electromagnetic waves is investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The characteristics of frequency spectrum ofthe radiated electromagnetic waves was measured at the atmospheric pressure in Liquid Nitrogen $(LN_2)$ during partial discharges in nonuniform and uniform electric field depend on positive DC power. From this experiment results, it was confirmed that when partial discharge was produced in Liquid Nitrogen and Air, the signal of partial discharge was detected by this experiment and the analysis method. It is considered thatthese results obtained from this investigation may be used as fundamental data for diagnosis and prediction of insulation on the equipments ultra-high voltage, superconducting and cryogenic applications.

  • PDF

대기중 방전진전에 따른 방사전자파의 주파수 스펙트럼 특성 (The Characteristic of Frequency Spectrum of Electromagnetic Waves Radiated from Discharge in Air)

  • 박광서;이상훈;주재현;최병주;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2245-2247
    • /
    • 1999
  • Insulation diagnosis techniques of power equipments for the stable power supply and prevention from accidents are of high importance. Diagnosis techniques is able to prevent from large accidents before they happen by finding signs of the accidents. From this point of view, this paper simulated discharge progress and partial discharge using needle-plan electrode system in air, studied the distribution of frequency spectrum of the radiated electromagnetic waves using biconical antenna and spectrum analyzer. From results of this study. the new method was introduced for measurement and analyzation of the radiated electromagnetic waves in accordance with discharge progress in air. Besides, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress were possible.

  • PDF

액체질소중 교류방전 진전에 따른 방사전자파 주파수 특성 (The Frequency Characteristics of Radiated Electromagnetic Waves in accordance with AC Discharge Progress in Liquid Nitrogen)

  • 박광서;이상훈;주재현;최병주;김기채;박원주;도대호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1975-1977
    • /
    • 2000
  • In this study, a relationship between AC discharge progress and the radiated electromagnetic waves were investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The characteristics of frequency spectrum of the radiated electromagnetic waves was measured at the atmospheric pressure in liquid nitrogen($LN_2$) during partial discharges progress in nonuniform electric field depend on AC power supply. From this results, it was confirmed that when partial discharge was produced in liquid nitrogen, the signal of partial discharge was detected by frequency spectrum of the radiated electromagnetic waves. It is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of insulation on superconducting and cryogenic power equipments.

  • PDF

친환경 가스 중 전극과 고체절연체의 불량접촉에 관한 절연진단연구 (Study on Insulation Diagnosis of Poor Contact between Electrode and Solid Insulator in Eco-Gas)

  • 임동영;최은혁;배성우;최상태;이광식;최병주
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.97-103
    • /
    • 2015
  • This paper presents the characteristics of partial discharge and radiated electromagnetic waves in the existence of a poor contact for the insulation diagnosis of eco-friendly power equipment. AC surface discharge experiment was conducted to simulate the poor contact between a hive voltage electrode (anode) and a solid insulator in $N_2/O_2$ mixture gas under a non-uniform field. The partial discharge voltage to be measured at 0.3MPa increased with the increase of the poor contact gap and was saturated with the gap. In addition to the partial discharge characteristics, it was verified that the defect of the poor contact can be diagnosed using the radiated electromagnetic waves due to the partial discharge, which measured by a biconical EMC antenna and a spectrum analyzer.

실내에서 I-UWB 시스템의 채널 모델링 및 검증 (The Verification of I-UWB Channel Model in Indoor)

  • 장필선;이석희;고영은;방성일
    • 대한전자공학회논문지TC
    • /
    • 제44권5호
    • /
    • pp.76-84
    • /
    • 2007
  • 본 논문에서는 가구나 생활 가전기기가 포함된 실내 아파트 환경에서의 I-UWB 시스템의 전송채널 특성을 측정하였다. 전송환경 특성은 10[MHz]${\sim}$16.01[GHz]의 영역에 대해 LOS와 NLOS 환경에서 주파수 영역과 시간 영역에 대해 측정하였다. 측정 데이터로부터 전파특성을 분석하기 위해 파라미터 도출 프로그램을 제작하여 PDP를 도출하였고, PDP로부터 다양한 전파 특성 파라미터를 산출하였다. 또한 채널특성에 따른 시스템의 성능을 평가하기 위해 Simulink로 I-UWB 시스템의 simulator를 모델링하고, 측정된 채널 모델을 삽입하여 모의실험 하였다. 모의실험 결과 SNR 20[dB] 이상에서 BER이 $10^{-5}$ 이하인 것을 확인할 수 있었다.

고체절연체표면의 오염상태에 따른 방전현상과 방사전자파의 주파수 특성 (The Frequency Characteristics of Electromagnetic Waves and Discharge Phenomena Caused by Polluted Condition of Solide Insulator Surface)

  • 김충년;박원주;이광식;이동인;김인식
    • 조명전기설비학회논문지
    • /
    • 제15권4호
    • /
    • pp.43-50
    • /
    • 2001
  • 본 논문은 구대구전극 사이에 고체절연체와 화염을 배치하여 방전시 절연체표면에서 발생되는 연면방전광과 화염의 변화를 CCD(Charged Coupled Device) 카메라로 관측하였으며, 방전시 발생되는 방사전자파는 스펙트럼 분석기와 바이코니칼 안테나를 이용하여 측정하였다. 인가전압 증가에 따른 고체절연체 표면에서 발생되는 연면 방전광은 커졌으며, 화염의 크기는 작아지는 것을 확인하였다. 또한 절연체표면 오염시와 화염시에는 전압강하에 의한 전압왜곡현상이 나타났다. 방사전자파의 전계세기는 절연체표면 무오염시에는 오염시보다 10∼17(dBuV/m), 절연체표면 오염시와 화염시에는 5∼9[dBuV/m]정도 높게 나타났다.

  • PDF