• 제목/요약/키워드: Bias Timing

검색결과 47건 처리시간 0.034초

Effects of hippotherapy on children with cerebral palsy: systematic review and meta-analysis

  • Kim, Kwon-Hoi;Lee, Suk-Min
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권1호
    • /
    • pp.55-65
    • /
    • 2020
  • Objective: The most important goal of hippotherapy is to improve function, gait, and balance. The purpose of this study was to investigate the effects of hippotherapy on function, gait, and balance of children with cerebral palsy (CP). Design: A systematic review and meta-analysis. Methods: We've searched the PubMed, EMBASE, and Cochrane Library CENTRAL databases for English experimental studies published up until September 2018. To analyze the effects of hippotherapy on the function, gait, and balance of children with cerebral palsy, the systematic review and meta-analysis were performed on Patient/Participants/Population Problem, Intervention, Comparison, Outcome with Timing, Setting Study Design. Papers retrieved from the database were removed from the literature management database. Methodological quality evaluation was evaluated using Cochrane's risk of bias. Data was analyzed using the Revman 5.3 program of the Cochrane library. Results: In this study, we found that the effect size of hippotherapy, denoted as d, was -3.82, and that hippotherapy had the most effect on gait, but no statistical significant difference was observed. We also found no significant difference in function and balance after hippotherapy. It was found from the funnel plot that there was no publication bias as the plot was symmetrically distributed around the dotted line. Conclusions: There are many unclear studies and a lack of randomized controlled trials (RCTs) in this research area. More RCTs on the effects of hippotherapy on children with CP should be conducted in the future.

펄스 타이밍 제어를 활용한 Ka-대역 10 W 전력증폭기 모듈 (A Ka-band 10 W Power Amplifier Module utilizing Pulse Timing Control)

  • 장석현;김경학;권태민;김동욱
    • 대한전자공학회논문지TC
    • /
    • 제46권12호
    • /
    • pp.14-21
    • /
    • 2009
  • 본 논문에서는 7개의 MMIC 전력증폭기 칩과 박막기판을 결합하여 MIC 모듈을 구성함으로써 Ka-대역 중심주파수 영역에서 10 W 이상의 출력전력을 가지는 펄스모드 전력증폭기 모듈을 설계하고 제작하였다. 전력증폭기 모듈의 제작에는 밀리미터파 대역에 적합한 수정된 형태의 윌킨슨 전력분배기/합성기와 모듈의 조림과정에서 공진을 억제하고 작은 삽입손실 특성을 보이는 CBFGCPW-Microstrip 천이구조를 활용하였다. 전력용 MMIC 바이어스 회로에 사용된 큰 값의 바이패스 캐패시터에 의해 발생되는 펄스모드 출력전력의 감소를 개선하고자 TTL 펄스 타이밍 제어 기법을 제안하였다. 제안된 방법을 10 kHz, $5\;{\mu}sec$ 펄스모드로 동작하는 전력증폭기 모듈에 적용한 결과 펄스모드 동작시간을 200 nsec 이상 개선할 수 있었고 0.62 W의 출력전력을 향상시킬 수 있었다. 구현된 전력증폭기 모듈은 59.5 dB의 전력이득과 11.89 W의 출력전력을 보여주었다.

Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis

  • Selvaraj, Abirami;Jain, Ravindra Kumar;Nagi, Ravleen;Balasubramaniam, Arthi
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.133-140
    • /
    • 2022
  • Purpose: The aim of this review was to systematically analyze the available literature on the correlation between the gray values (GVs) of cone-beam computed tomography (CBCT) and the Hounsfield units (HUs) of computed tomography (CT) for assessing bone mineral density. Materials and Methods: A literature search was carried out in PubMed, Cochrane Library, Google Scholar, Scopus, and LILACS for studies published through September 2021. In vitro, in vivo, and animal studies that analyzed the correlations GVs of CBCT and HUs of CT were included in this review. The review was prepared according to the PRISMA checklist for systematic reviews, and the risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. A quantitative analysis was performed using a fixed-effects model. Results: The literature search identified a total of 5,955 studies, of which 14 studies were included for the qualitative analysis and 2 studies for the quantitative analysis. A positive correlation was observed between the GVs of CBCT and HUs of CT. Out of the 14 studies, 100% had low risks of bias for the domains of patient selection, index test, and reference standards, while 95% of studies had a low risk of bias for the domain of flow and timing. The fixed-effects meta-analysis performed for Pearson correlation coefficients between CBCT and CT showed a moderate positive correlation (r=0.669; 95% CI, 0.388 to 0.836; P<0.05). Conclusion: The available evidence showed a positive correlation between the GVs of CBCT and HUs of CT.

Source-Follower Type Analog Buffer Using Low Temperature Poly-Si TFTs for AMLCDs

  • Chen, Bo-Ting;Tai, Ya-Hsiang;Wei, Ying-Jyun;Tsai, Chun-Chien;Chen, Hsu-Hsin;Huang, Chun-Yao;Kuo, Yu-Ju;Cheng, Huang-Chung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1243-1246
    • /
    • 2006
  • A new source follower circuit for the integrated circuit of AMLCDs is proposed. Active load is added and calibration operation is applied to compensate the circuits. Proposed circuit is capable of minimizing the variation from both timing and device variations through measured results, the uniformity and bias effect are discussed.

  • PDF

Performance Analysis of the Wireless Localization Algorithms Using the IR-UWB Nodes with Non-Calibration Errors

  • Cho, Seong Yun;Kang, Dongyeop;Kim, Jinhong;Lee, Young Jae;Moon, Ki Young
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제6권3호
    • /
    • pp.105-116
    • /
    • 2017
  • Several wireless localization algorithms are evaluated for the IR-UWB-based indoor location with the assumption that the ranging measurements contain the channelwise Non-Calibration Error (NCE). The localization algorithms can be divided into the Model-free Localization (MfL) methods and Model-based Kalman Filtering (MbKF). The algorithms covered in this paper include Iterative Least Squares (ILS), Direct Solution (DS), Difference of Squared Ranging Measurements (DSRM), and ILS-Common (ILS-C) methods for the MfL methods, and Extended Kalman Filter (EKF), EKF-Each Channel (EKF-EC), EKF-C, Cubature Kalman Filter (CKF), and CKF-C for the MbKF. Experimental results show that the DSRM method has better accuracy than the other MfL methods. Also, it demands smallest computation time. On the other hand, the EKF-C and CKF-C require some more computation time than the DSRM method. The accuracy of the EKF-C and CKF-C is, however, best among the 9 methods. When comparing the EKF-C and CKF-C, the CKF-C can be easily used. Finally, it is concluded that the CKF-C can be widely used because of its ease of use as well as it accuracy.

국내 기준국의 GPS 코드 다중경로오차 격자지도 생성 (Developing GPS Code Multipath Grid Map (CMGM) of Domestic Reference Station)

  • 김규민;김기민;박찬덕
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제13권1호
    • /
    • pp.85-92
    • /
    • 2024
  • This study develops a Global Positioning System (GPS) Code Multipath Grid Map (CMGM) of each individual domestic reference station from the extracted code multipath of measurement data. Multipath corresponds to signal reflection/refraction caused by obstacles around the receiver antenna, and it is a major source of error that cannot be eliminated by differencing. From the receiver-independent exchange format (RINEX) data for two days, the associated code multipath of a satellite tracking arc is extracted. These code multipath data go through bias correction and interpolation to yield the CMGM with respect to the azimuth and elevation angles. The effect of the CMGM on multipath mitigation is then quantitatively analyzed to improve the Root Mean Square (RMS) of averaged pseudo multipath. Furthermore, the single point positioning (SPP) accuracy is analyzed in terms of the RMS of the horizontal and vertical errors. During two weeks in February 2023, the RMSs of the averaged pseudo multipath for five reference stations decreased by about 40% on average after CMGM application. Also, the SPP accuracies increased by about 7% for horizontal errors and about 10% for vertical errors on average after CMGM application. The overall quantitative analysis indicates that the proposed approach will reduce the convergence time of Differential Global Navigation Satellite System (DGNSS), Real-Time Kinematic (RTK), and Precise Point Positioning (PPP)-RTK correction information in real-time to use measurement data whose code multipath is corrected and mitigated by the CMGM.

Efficiency calculation of the nMCP with 10B doping based on mathematical models

  • Yang, Jianqing;Zhou, Jianrong;Zhang, Lianjun;Tan, Jinhao;Jiang, Xingfen;Zhou, Jianjin;Zhou, Xiaojuan;Hou, Linjun;Song, Yushou;Sun, XinLi;Zhang, Quanhu;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2364-2370
    • /
    • 2021
  • The nMCP (Neutron sensitive microchannel plate) combined with advanced readout electronics is widely used in energy selective neutron imaging because of its good spatial and timing resolution. Neutron detection efficiency is a crucial parameter for the nMCP. In this paper, a mathematical model based on the oblique cylindrical channel and elliptical pore was established to calculate the neutron absorption probability, the escape probability of charged particles and overall detection efficiency of nMCP and analyze the effects of neutron incident position, pore diameter, wall thickness and bias angle. It was shown that when the doping concentration of the nMCP was 10 mol%, the thickness of nMCP was 0.6 mm, the detection efficiency could reach maximum value, about 24% for thermal neutrons if the pore diameter was 6 ㎛, the wall thickness was 2 ㎛ and the bias angle was 3 or 6°. The calculated results are of great significance for evaluating the detection efficiency of the nMCP. In a subsequent companion paper, the mathematical model would be extended to the case of the spatial resolution and detection efficiency optimization of the coating nMCP.

실린더 압력을 이용한 SI엔진의 페루프 점화시기 제어에 관한 연구 (SI Engine Closed-loop Spark Advance Control Using Cylinder Pressure)

  • 박승범;윤팔주;선우명호
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2361-2370
    • /
    • 2000
  • The introduction of inexpensive cylinder pressure sensors provides new opportunities for precise engine control. This paper presents a control strategy of spark advance based upon cylinder pressure of spark ignition engines. A location of peak pressure(LPP) is the major parameter for controlling the spark timing, and also the UP is estimated, using a multi-layer feedforward neural network, which needs only five pressure sensor output voltage samples at -40˚, -20˚, 0˚, 20˚, 40˚ after top dead center. The neural network plays an important role in mitigating the A/D conversion load of an electronic engine controller by increasing the sampling interval from 10 crank angle(CA) to 20˚ CA. A proposed control algorithm does not need a sensor calibration and pegging(bias calculation) procedure because the neural network estimates the UP from the raw sensor output voltage. The estimated LPP can be regarded as a good index for combustion phasing, and can also be used as an MBT control parameter. The feasibility of this methodology is closely examined through steady and transient engine operations to control individual cylinder spark advance. The experimental results have revealed a favorable agreement of individual cylinder optimal combustion phasing.

보건소 중심의 노인운동 프로그램에 대한 체계적 문헌고찰 (A Systematic Review of Literature on Community Health Center Exercise Programs)

  • 한숙정;이영란;조정민;임미영
    • 지역사회간호학회지
    • /
    • 제26권1호
    • /
    • pp.18-30
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the research methods, types and effects of community health center exercise programs for the elderly. Methods: We established the PICOTS-SD (Participants, Interventions, Comparisons, Outcomes, Timing of outcome measurement, Setting, Study Design), reviewed 583 studies from electronic database of DBpia, KoreaMed, KISS, RISS, NDSL and Pubmed, and finally selected 20 studies based on the inclusion and exclusion criteria. Methodological quality was assessed with the Risk-of-Bias Assessment tool for non-randomized studies. Results: With regard to research methods, the majority of studies on community health center exercise programs for the elderly were performed after 2010 and using non-equivalent control group pretest-posttest research design. As for the types and effects of exercise programs, the exercise period ranged from 6 to 28 weeks, and the most common exercise frequency was three times a week for 60 minutes. In addition, mixed-type and group exercise programs were performed most commonly. Conclusion: The results of this study provide a basis for the development of exercise programs to improve elders' health.

A Multistage In-flight Alignment with No Initial Attitude References for Strapdown Inertial Navigation Systems

  • Hong, WoonSeon;Park, Chan Gook
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.565-573
    • /
    • 2017
  • This paper presents a multistage in-flight alignment (MIFA) method for a strapdown inertial navigation system (SDINS) suitable for moving vehicles with no initial attitude references. A SDINS mounted on a moving vehicle frequently loses attitude information for many reasons, and it makes solving navigation equations impossible because the true motion is coupled with an undefined vehicle attitude. To determine the attitude in such a situation, MIFA consists of three stages: a coarse horizontal attitude, coarse heading, and fine attitude with adaptive Kalman navigation filter (AKNF) in order. In the coarse horizontal alignment, the pitch and roll are coarsely estimated from the second order damping loop with an input of acceleration differences between the SDINS and GPS. To enhance estimation accuracy, the acceleration is smoothed by a scalar filter to reflect the true dynamics of a vehicle, and the effects of the scalar filter gains are analyzed. Then the coarse heading is determined from the GPS tracking angle and yaw increment of the SDINS. The attitude from these two stages is fed back to the initial values of the AKNF. To reduce the estimated bias errors of inertial sensors, special emphasis is given to the timing synchronization effects for the measurement of AKNF. With various real flight tests using an UH60 helicopter, it is proved that MIFA provides a dramatic position error improvement compared to the conventional gyro compass alignment.