• 제목/요약/키워드: Bi-direction DC-DC converter

검색결과 5건 처리시간 0.028초

직류전기철도에서 운행시격에 따른 에너지저장장치의 효율에 관한 연구 (A Study on the Efficiency of Energy Storage System Applied to the Power Traction System of DC Electric Railway)

  • 김성대;최규형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.754-760
    • /
    • 2011
  • In the DC traction system, a large load current of electric railcar leads to a voltage drop when a vehicle starts, and the regenerative power generated by brake system increases the catenary voltage. To minimize the voltage fluctuation during the train operation and make use of the regenerative power, several types of energy storage systems are being studied. The energy storage system that is being recently introduced consists of the supercapacitors for energy storage and the bi-direction DC/DC converter for charge/discharge control. The efficiency of the energy storage system depends on the train operation pattern. In this paper, the operation efficiency of the energy storage system was quantitatively analyzed via simulation study taking consideration of the train operation patterns. The simulation was conducted changing the headway of trains with the energy storage system that uses the bi-direction DC/DC converter and supercapacitor. The simulation results showed that the operation efficiency of the energy storage system increases as the headway increase.

  • PDF

에너지저장시스템의 충, 방전 Auto Level-Tuning 알고리즘에 관한 연구 (Study for Charge-Discharge Auto Level-Tuning Algorithm of Energy storage system)

  • 백승길;임지영;차준일;김길동;권경민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.514-520
    • /
    • 2010
  • This paper is about control algorithms that bi-direction DC-DC Converter using Super Capacitor and regenerative power from DC feeding system in train. In order to take advantage of regenerative energy efficient, charge and discharge level value of energy storage system serve as an important factor. Respect to output fluctuations of the substation and catenary voltage changing, we offers Charge-Discharge Auto Level Tuning Algorithms to improve system following of Energy Storage System.

  • PDF

건물 조명을 위한 PV ESS 동작모드 및 제어기법 (Operation mode and Control method of PV ESS for Building Lighting)

  • 팽성일;박운호;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.118-119
    • /
    • 2017
  • This paper proposes the operation mode and control method of the PV ESS for building lighting. The PV ESS is consisted of 3.3kW single phase grid connected PV inverter, Bi-direction DC/DC converter for Charging/Discharging for battery and DC48V Buck DC/DC converter for LED lighting.

  • PDF

방향 절환이 자유로운 양방향 DC/DC 컨버터 개발 (Development of a Bidirectional DC/DC Converter with Smooth Transition Between Different Operation Modes)

  • 유창규;이우철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권4호
    • /
    • pp.224-230
    • /
    • 2006
  • The conventional way to implement a bidirectional converter with boost/buck has been to use two general purpose PWM ICs with a single supply voltage. In this case, when one direction mode is in operation, the other is disabled and the output of the error amplifier of the disabled IC may be saturated to a maximum value or zero. Therefore, during mode transition, a circuit which can disable the switching operation for a certain time interval is required making it impossible to get a seamless transition. In this paper, the limitations of the conventional 42V/14V bi-directional DC/DC converter implemented with general current mode PWM ICs with a single supply voltage are reviewed and a new current mode PWM controller circuit with a dual voltage system is proposed. The validity of the proposed circuit is investigated through simulation. and experiments.

영전류 모드 도통손실 저감을 위한 ZVT Interleaved Bi-directional LDC의 위상 제어 (Phase Control of ZVT Interleaved Bi-directional LDC for Reducing Conduction Losses in Zero-Current Mode)

  • 정원상;이순령;이종영;박윤지;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.367-368
    • /
    • 2017
  • 본 논문에서는 영전류 모드로 진입한 zero voltage transition(ZVT) interleaved bi-direction low voltage DC-DC converter(IB-LDC)의 도통 손실을 최소화하기 위한 위상 제어가 제안된다. IB-LDC의 출력단 배터리가 완충되어 영전류 모드로 진입하면 IB-LDC의 입 출력 평균 전류는 0[A]로 감소하지만 보조 회로 전류는 기존의 설계 값에 의해 감소하지 않아 지속적인 도통 손실을 일으킨다. 따라서 본 논문에서는 영전류 모드로 진입한 IB-LDC의 보조 회로에 ZVT 조건을 만족시키는 공진 전류만 흐르도록 하여 도통 손실을 최소화하는 위상 제어를 제안하였다. 또한 PSIM simulation 및 실험을 통해 증명하였다.

  • PDF