• Title/Summary/Keyword: Best-estimate Analysis

Search Result 306, Processing Time 0.033 seconds

Static Worst-Case Energy and Lifetime Estimation of Wireless Sensor Networks

  • Liu, Yu;Zhang, Wei;Akkaya, Kemal
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.128-152
    • /
    • 2010
  • With the advance of computer and communication technologies, wireless sensor networks (WSNs) are increasingly used in many aspects of our daily life. However, since the battery lifetime of WSN nodes is restricted, the WSN lifetime is also limited. Therefore, it is crucial to determine this limited lifetime in advance for preventing service interruptions in critical applications. This paper proposes a feasible static analysis approach to estimating the worstcase lifetime of a WSN. Assuming known routes with a given sensor network topology and SMAC as the underlying MAC protocol, we statically estimate the lifetime of each sensor node with a fixed initial energy budget. These estimations are then compared with the results obtained through simulation which run with the same energy budget on each node. Experimental results of our research on TinyOS applications indicate that our approach can safely and accurately estimate worst-case lifetime of the WSN. To the best of our knowledge, our work is the first one to estimate the worst-case lifetime of WSNs through a static analysis method.

The Combining Ability Analysis and Heterosis for some Quanitatives Traits in the Silkworm (Bombyx mori L.)

  • Moghaddam S. H. Hosseini;Etebari K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.10 no.2
    • /
    • pp.153-157
    • /
    • 2005
  • Recently two breeding programs were carried out for isolation of new parental inbred lines in Iran. This study was undertaken in order to estimate the combining ability effects and heterosis of these lines. For this purpose an $8\times8$ diallel cross analysis including eight inbred lines of silkworm with four lines from each program were studied for their five quantitative traits. The results indicated that reciprocal effects appeared insignificant for most of traits. Japanese lines of 111 and 113 were best combiners for shell weight, cocoon weight and shell percentage traits. With respect to pupation rate, Chinese line 110 was the best and according to general combining ability (GCA) and specific combining ability (SCA) variances, it is superior in specific combinations. Hybrid $109\times110$ showed better characters for both productive and viability traits. Hybrids with high heterosis had high SCA too.

Frequency Analysis of Extreme Rainfall using Higher Probability Weighted Moments (고차확률가중모멘트에 의한 극치강우의 빈도분석)

  • Lee, Soon-Hyuk;Maeng, Sung-Jin;Ryoo, Kyong-Sik;Kim, Byeong-Jun
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.511-514
    • /
    • 2003
  • This study was conducted to estimate the design rainfall by the determination of best fitting order for Higher Probability Weighted Moments of the annual maximum series according to consecutive duration at sixty-five rainfall stations in Korea. Design rainfalls were obtained by generalized extreme value distribution which was selected to be suitable distribution in 4 applied distributions and by L, L1, L2, L3 and L4-moment. The best fitting order for Higher Probability Weighted Moments was determined with the confidence analysis of estimated design rainfall.

  • PDF

Optimization of Nozzle Arrangement in a Liquid Direct Contact Cooling System : Constant Inlet Flowrate Analysis (액체식 직접 접촉 냉각장치의 노즐배열 최적화 : 정풍량 해석)

  • Kim Won-Nyun;Kim Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.402-409
    • /
    • 2006
  • For the design of a liquid direct contact cooling system, thermal and hydraulic analysis has been carried out. Well-known Zukauskas correlations are used to estimate the Nusselt number between the liquid refrigerant columns and the inlet airflow. The inlet air velocity is set at a typical value used in an actual showcase. For a constant column number, the best nozzle arrangement is determined for the maximum heat transfer. Heat transfer increases as the transverse pitch of the refrigerant column decreases. Among all the cases dealt with in the present study, the staggered arrangement with 140-columns of $14{\times}10$ shows the best thermal peformance and the expected temperature drop is $27.8^{\circ}C$. The effect of downstream refrigerant columns on the overall thermal performance is investigated as well.

Measurement of Na intake in Korean Adult Females (우리나라 성인 여성의 Na 섭취량 측정방법의 모색)

  • 김영선
    • Journal of Nutrition and Health
    • /
    • v.20 no.5
    • /
    • pp.341-349
    • /
    • 1987
  • Dietary intakes of na include both the amount present in food materials (nondiscretionary Na intake) and the amount added during cooking and eating to increase salty taste and flavor (discretionary Na intake). In the present study, total Na intake was measured by duplicate food sample collected from each subject for 1 day, nondiscretionary Na intake was calculated by dietary intake record, optimum gustation of salt was measured of from pooled 3-day urine collection in healthy female college students, to measure Na intake more accurately and to find suitable method to estimate total Na intake. Mean values of total, discretionary and mondiscretionary Na intakes were 169.6 mEq, 46.2mEq, and 123.4mEq. respectively. Mean 24-hour urinary Na excretion was 137.9mEq., which was about 84.5% of total intake. Subjects with optimum gustation of salt equal to or higher than 0.5% had significantly higher total Na intake and urinary Na excretion compared to subjects with optimum gustation of salt lower than 5%. Total Na intake of subjects were significantly correlated with optimum gustation of salt, non-discretionary and discretionary Na intakes, and urinary Na excretion. Multiple regression analysis showed that the best estimate of total Na intake is obtained when both optimum gustation of salt and non-discredinary Na intake were used as independent variables (r=.7071). Among the equations using one independent variable, regression, equation with urinary Na excretion provides the best approximation (r=.6627) of total Na intake.

  • PDF

Loss of a Main Feedwater Pump Test Simulation Using KISPAC Computer Code

  • Jeong, Won-Sang;Sohn, Suk-Whun;Seo, Ho-Taek;Seo, Jong-Tae
    • Nuclear Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.265-273
    • /
    • 1996
  • Among those tests performed during the Yonggwang Nuclear Power Plant Units 3 and 4 (YGN 3&4) Power Ascension Test period, the Loss of a Main Feedwater Pump test at l00% power is one of the major test which characterize the capability of YGN 3&4. In this event, one of the two normally operating main feedwater pumps is tripped resulting in a 50% reduction in the feedwater flow. Unless the NSSS and Turbine/Generator control systems actuate properly, the reactor will be tripped on low SG water level or high pressurizer pressure. The test performed at Unit 3 was successful by meeting all acceptance criteria, and the plant was stabilized at a reduced power level without reactor trip. The measured test data for the major plant parameters are compared with the predictions made by the KISPAC computer code, an updated best-estimate plant performance analysis code, to verify and validate its applicability. The comparison results showed good agreement in the magnitude as well as the trends of the major plant parameters. Therefore, the KISPAC code can be utilized for the best-estimate nuclear power plant design and simulation tool after a further verification using other plant test data.

  • PDF

Probability Funetion of Best Fit to Distribution of Extremal Minimum Flow and Estimation of Probable Drought Flow (극소치유량에 대한 적정분포형의 설정과 확률갈수량의 산정)

  • 김지학;이순탁
    • Water for future
    • /
    • v.8 no.1
    • /
    • pp.80-88
    • /
    • 1975
  • In this paper the authors established the best fit distribution function by applying the concept of probabiaity to the annual minimum flow of nine areas along the Nakdong river basin which is one of the largest Korean rivers and calculated the probable minimum flow suitable to those distribution function. Lastly, the authors tried to establish the best method to estimate the probable minimun flow by comparing some frequency analysis methods. The results obtained are as follows (1) It was considered that the extremal distribution type III was the most suitable one in the distributional types as a result of the comparision with Exponential distribution, Log-Normal distribution, Extremal distribution type-III and so on. (2) It was found that the formula of extremal distribution type-II for the estimation of probable minimum flow gave the best result in deciding the probable minimum flow of the Nakdong river basin. Therfore, it is recommended that the probable minimum flow should be estimated by using the extremal distribution type-III method. (3) It could be understood that in the probable minimum flow the average non-excessive probability appeared to be $Po{\fallingdotseq}1-\frac{1}{2T}$ and gave the same values of the probable variable without any difference in the various methods of plotting technique.

  • PDF

Cost Effectiveness Analysis of Different Management Strategies between Best Supportive Care and Second-line Chemotherapy for Platinum-resistant or Refractory Ovarian Cancer

  • Luealon, Phanida;Khempech, Nipon;Vasuratna, Apichai;Hanvoravongchai, Piya;Havanond, Piyalamporn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.799-805
    • /
    • 2016
  • Background: There is no standard treatment for patients with platinum-resistant or refractory epithelial ovarian cancer. Single agent chemotherapies have evidence of more efficacy and less toxicity than combination therapy. Most are very expensive, with appreciable toxicity and minimal survival. Since it is difficult to make comparison between outcomes, economic analysis of single-agent chemotherapy regimens and best supportive care may help to make decisions about an appropriate management for the affected patients. Objective: To evaluate the cost effectiveness of second-line chemotherapy compared with best supportive care for patients with platinum-resistant or refractory epithelial ovarian cancer. Materials and Methods: A Markov model was used to estimate the effectiveness and total costs associated with treatments. The hypothetical patient population comprised women aged 55 with platinum-resistant or refractory epithelial ovarian cancer. Four types of alternative treatment options were evaluated: 1) gemcitabine followed by BSC; 2) pegylated liposomal doxorubicin (PLD) followed by BSC; 3) gemcitabine followed by topotecan; and 4) PLD followed by topotecan. Baseline comparator of alternative treatments was BSC. Time horizon of the analysis was 2 years. Health care provider perspective and 3% discount rate were used to determine the costs of medical treatment in this study. Quality-adjusted life-years (QALY) were used to measure the treatment effectiveness. Treatment effectiveness data were derived from the literature. Costs were calculated from unit cost treatment of epithelial ovarian cancer patients at various stages of disease in King Chulalongkorn Memorial Hospital (KCMH) in the year 2011. Parameter uncertainty was tested in probabilistic sensitivity analysis by using Monte Carlo simulation. One-way sensitivity analysis was used to explore each variable's impact on the uncertainty of the results. Results: Approximated life expectancy of best supportive care was 0.182 years and its total cost was 26,862 Baht. All four alternative treatments increased life expectancy. Life expectancy of gemcitabine followed by BSC, PLD followed by BSC, gemcitabine followed by topotecan and PLD followed by topotecan was 0.510, 0.513, 0.566, and 0.570 years, respectively. The total cost of gemcitabine followed by BSC, PLD followed by BSC, gemcitabine followed by topotecan and PLD followed by topotecan was 113,000, 124,302, 139,788 and 151,135 Baht, respectively. PLD followed by topotecan had the highest expected quality-adjusted life-years but was the most expensive of all the above strategies. The incremental cost-effectiveness ratios (ICER) of gemcitabine followed by BSC, PLD followed by BSC, gemcitabine followed by topotecan and PLD followed by topotecan was 344,643, 385,322, 385,856, and 420,299 Baht, respectively. Conclusions: All of the second-line chemotherapy strategies showed certain benefits due to an increased life-year gained compared with best supportive care. Moreover, gemcitabine as second-line chemotherapy followed by best supportive care in progressive disease case was likely to be more effective strategy with less cost from health care provider perspective. Gemcitabine was the most cost-effective treatment among all four alternative treatments. ICER is only an economic factor. Treatment decisions should be based on the patient benefit.

THE BIDAS-2007: BIOASSAY DATA ANALYSIS SOFTWARE FOR EVALUATING A RADIONUCLIDE INTAKE AND DOSE

  • Lee, Jong-Il;Lee, Tae-Young;Kim, Bong-Whan;Kim, Jang-Lyul
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.109-114
    • /
    • 2010
  • Bioassay data analysis software (BiDAS-2007) has been developed by KAERI, which adds several new functions to its previous version. New functions of the BiDAS-2007 computer code enable the user not only to do a simultaneous analysis by using two or more types of bioassay for the best internal dose evaluation, but also to do a continual internal dose evaluation from a change of the internal exposure conditions such as an intake type (acute, chronic), an intake pathway (inhalation, ingestion), an absorption type (Type F, M, S), and a particle size (AMAD, activity median aerodynamic diameter), and also to estimate the intakes in various conditions of an internal exposure at a time. The values calculated by the BiDAS-2007 code are consistent and in good agreement with those values by IMIE-2004 code by Berkovski and IMBA code by Birchall. The BiDAS-2007 computer code is very useful and user-friendly to estimate the radionuclide intakes and committed effective doses of a radiation worker.

Simulation Analysis of radar responses with frequencies on subsurface voids in concrete (레이더 주파수대별 콘크리트내 층간 연속공동의 시뮬레이션 해석)

  • 박석균
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1279-1284
    • /
    • 2000
  • This study introduces a simulation model of radar responses with frequencies on subsurface voids in concrete. In this model, the resolution and the attenuation according to radar frequencies in each interface which has different electromagnetic property are analyzed. This model aims to select the best frequency of radar which can analyze the thickness of voids in concrete from radar response. It also can be applied to estimate the limitation of propagation depth of radar on subsurface voids in concrete. The computed results show the radar images based on radar signal processing using convolution technique.