• Title/Summary/Keyword: Bending

Search Result 8,649, Processing Time 0.046 seconds

Effect of water storage on the fracture toughness of dental resin cement used for zirconia restoration (수분이 지르코니아 수복물 전용 레진시멘트의 파괴인성에 미치는 영향에 관한 연구)

  • Goo, Bon-Wook;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung;Ha, Seung-Ryong;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.312-316
    • /
    • 2014
  • Purpose: The aim of this study was to compare the fracture toughness of currently available resin cements for zirconia restorations and evaluate the effect of water storage on fracture toughness of those resin cements. Materials and methods: Single-edge notched specimens ($3mm{\times}6mm{\times}25mm$) were prepared from three currently available dual cure resin cements for zirconia restorations (Panavia F 2.0, Clearfil SA luting and Zirconite). Each resin cement was divided into four groups: immersed in distilled water at $37^{\circ}C$ for 1 (Control group), 30, 90, or 180 days (n=5). Specimens were loaded in three point bending at a cross-head speed of 0.1 mm/s. The maximum load at specimen failure was recorded and the fracture toughness ($K_{IC}$) was calculated. Data were analyzed using one-way ANOVA and multiple comparison $Scheff{\acute{e}}$ test (${\alpha}$=.05). Results: In control group, the mean $K_{IC}$ was $3.41{\pm}0.64MN{\cdot}m^{-1.5}$ for Panavia F, 2.0, $3.07{\pm}0.41MN{\cdot}m^{-1.5}$ for Zirconite, $2.58{\pm}0.30MN{\cdot}m^{-1.5}$ for Clearfil SA luting respectively, but statistical analysis revealed no significant difference between them. Although a gradual decrease of $K_{IC}$ in Panavia F 2.0 and gradual increases of KIC in Clearfil SA luting and Zirconite were observed with storage time, there were no significant differences between immersion time for each cement. Conclusion: The resin cements for zirconia restorations exhibit much higher $K_{IC}$ values than conventional resin cements. The fracture toughness of resin cement for zirconia restoration would not be affected by water storage.

The Effect of Exercise Program on Chronic Low Back Pain in Female Teachers of Elementary School (만성요통 여교사에 대한 운동프로그램의 효과 - 근력, 근지구력, 유연성, 통증, 기능장애, 우울 및 생활만족도를 중심으로 -)

  • Choi, Soon-Young
    • Women's Health Nursing
    • /
    • v.7 no.2
    • /
    • pp.169-187
    • /
    • 2001
  • This study was performed to probe the effect of exercise program on muscle strength, endurance, flexibility, pain, disability level and life satisfaction in female teachers of elementary school who complain of low back pain. For this study, 44 female teachers aged 30-50 years with mechanical low back pain of 6 months' duration, who had the structural normalities in the lumbar spine, were recruited from April 1 to July 10 1999. Twenty three out of them were assigned to the experimental group and twenty one to the control group. The exercise program consisted of education on right postures, the etiology and diagnosis of low back pain, and exercise intervention such as muscle relaxation, elongation and strengthening. With 8 weeks program, the subjects received two sessions of education and six sessions of group exercise in the 1st week, while three sessions of group exercise and four sessions of individual exercise weekly and two sessions of education during the later 7 weeks. The muscle strength and endurance were measured by Cybex 770, the flexibility by flexibility measurement machine, the intensity of pain by Visual Analogue Scale (VAS), the level of disability by Oswestry low back pain disability scale, depression by Beck depression inventory (BDI), and life satisfaction by Life satisfaction index-Z. Study measurements were taken before and after 8 weeks exercise program. Data were analyzed using paired t-test, t-test, and ANCOVA. The results were as follows ; 1. The flexors and extensors peak torque and flexors peak torque per body weight of experimental group were significantly increased at test velocities $30^{\circ}$/sec, $60^{\circ}$/sec compared with those of control group. There was no significant difference in extensors peak torque per flexors peak torque at $30^{\circ}/sec$, $60^{\circ}/sec$ between experimental and control group. 2. The flexors and extensors total work and flexors total work per body weight of experimental group were significantly increased at $120^{\circ}/sec$, compared with those of control group. 3.The flexibility of lumbar spine in experimental group was significantly increased compared with that of control group. The pains in anterior, posterior, left lateral and right lateral bending and in rotation of experimental group were significantly increased compared with those of control group. 4. The Oswestry disability scores of experimental and control group were significantly decreased, and there was no difference in the Oswestry disability score change between experimental and control group. 5. The scores of BDI of experimental group were significantly decreased compared with those of control group. Life satisfaction index-Z scores of experimental group were not changed, but those of control group were significantly decreased. There was no difference in the score change of Life satisfaction index-Z between experimental and control group. 6. ANCOVA analysis for the data variables of inhomogeneous baseline represented that there was no significant difference in extensors peak torque and extensors total work at $120^{\circ}/sec$ and extensor total work per body weight at $120^{\circ}/sec$ change between experimental group and control group. These findings indicate that the exercise program could be effective in increasing the muscle strength, endurance, flexibility and decreasing pain, improving depression in female teachers of elementary school with chronic low back pain. It is suggested that the exercise program could be an essential factor for the effective nursing intervention to the patients suffered from chronic low back pain.

  • PDF

Structural Analysis of Concrete-filled FRP Tube Dowel Bar for Jointed Concrete Pavements (콘크리트 포장에서 FRP 튜브 다웰바의 역학적 특성 분석)

  • Park, Jun-Young;Lee, Jae-Hoon;Sohn, Dueck-Su
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.21-30
    • /
    • 2011
  • As well known, dowel bars are used to transfer traffic load acting on one edge to another edge of concrete slab in concrete pavement system. The dowel bars widely used in South Korea are round shape steel bar and they shows satisfactory performance under bending stress which is developed by repetitive traffic loading and environment loading. However, they are not invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Especially, the erosion could rapidly progress with saline to prevent frost of snow in winter time. The problem under this circumstance is that the erosion not only drops strength of the steel dower bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem in reasonable expenses, dowers bars with various materials are being developed. Fiber reinforced plastic(FRP) dower that is presented in this paper is suggested as an alternative of the steel dowel bar and it shows competitive resistance against erosion and tensile stress. The FRP dowel bar is developed in tube shape and is filled with high strength no shrinkage. Several slab thickness designs with the FRP dowel bars are performed by evaluating bearing stress between the dowel bar and concrete slab. To calculated the bearing stresses, theoretical formulation and finite element method(FEM) are utilized with material properties measured from laboratory tests. The results show that both FRP tube dowel bars with diameters of 32mm and 40mm satisfy bearing stress requirement for dowel bars. Also, with consideration that lean concrete is typical material to support concrete slab in South Korea, which means low load transfer efficiency and, therefore, low bearing stress, the FRP tube dowel bar can be used as a replacement of round shape steel bar.

The Study of Effect and Safety related to Dong-gi Acupuncture(DGA) and Complex therapy on Lumbago due to blood stasis and sprain (좌섬(挫閃)·어혈(瘀血) 요통(腰痛)에 동기침법(動氣鍼法) 및 복합치료(複合治療)의 유효성(有效性) 및 안정성(安定性) 연구(硏究))

  • Kim, Kee-Hyun;Lim, Hyung-Ho;Hwang, Hyeon-Seo;Song, Ho-Sueb;Song, Young-Sang;Kwon, Soon-Jung;Kim, Kyung-Nam;Ahn, Koang-Hyun;Lee, Seong-No;Kang, Mi-Suk;Gyun, Im-Jung
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.107-114
    • /
    • 2002
  • Objective : This study was designed to find the most effective and safest way to overcome Lumbago due to blood stasis and sprain involved in a few Meridian Tendino-musculatures by evaluating the effect of two kinds of Dong-gi(Dong-qi) Acupuncture(DGA) and by reporting their side effects. Material : 97 patients of out and admission patients were selected, who were diagnosed with lumbar sprain caused by repetitive bending, heavy weight lifting, unsuitable posture, concussion and falling down and whose Lumbago due to blood stasis and sprain in the concept of oriental medicine. Methods : 97 patients were divided into three groups. One is exclusive DGA group to which DGA and the method retaining needles on the acupoints for about 20 minutes were applied, the other is DGA combined active exercise group in which patients stretched their Meridian Tendino-muscuIatures with their hips moving up and downward repeatedly during DGA, the third is DGA combined passive exercise group in which patients were made to flex or extend their bodies on the auto flexion-distraction table in a prone position, from 10 to 20 degree, during DGA. In each group, bed rest, physical therapy and herbal medicine were used according to symptoms, in addition to DGA. In DGA method, "Su(Shu)" points of the meridian related to the involved Meridian Tendino-musculature were mainly chosen, that is, Sokkol(Shugu, B65), Hugye(Houxi, SI3), ChungJo(Zhongzhu, TE3) were used, for most LBP belonged to Bladder and Gallbladder Meridian Tendino-musculature disorders. Pyong-Bo-Pyong-Sa(Ping-Bu-Ping-Xie) such as Dong-Gi and Yeom-Jeon(Nian-Zhuan) was applied as Bo-Sa method. For evaluation of effectiveness, new score system was devised by severity of pain and range of movement. the score was given twice at patients' first and last visit and the difference between first and last score was regarded as a evaluation scale, the effectiveness was classified into four grade by evaluation scale.(scale : 12-15; excellent, 8-11; good, 4-7; fair, 0-3; bad) Results : 1. Exclusive DGA, DGA combined active exercise and DGA combined passive exercise group showed 97, 87 and 89% in effectiveness. 2. Exclusive DGA, DGA combined active exercise and DGA combined passive exercise group showed no aggravation of pain, range of movement. 3. In blood test of 34 patients, only one patient showed abnormal rise of sGOT, sGPT and $\gamma$-GTP at his first visit and the others didn't show any detrimental change. DGA had no bad influence upon BUN and creatinine of patients. Conclusion : For complex theraphy combining DGA, exercise, physical therapy and Herbal medicine proved to be highly effective on treating lumbago due to blood stasis and sprain, this is expected to be available for clinical use.

  • PDF

An experimental study on diameter increase of orthodontic wire by electroplating (전기도금을 이용한 스테인레스 스틸 선재의 직경 증가에 관한 실험적 연구)

  • Cho, Jin-Hyoung;Sung, Young-Eun;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.121-130
    • /
    • 2003
  • The purpose of this study was to evaluate the possibile clinical application of electroplating to increase diameter of an orthodontic wire, through examining the change of physical properties. The diameter of stainless steel orthodontic wire was increased from 0.016 inch to 0.018 inch by electroplating in a bath of nickel sulfate 100g/L, nickel chloride 60g/L, boric acid 30g/L, and sodium chloride 50g/L, under the conditions of 1.7V, $25\~29^{\circ}C\;and\;3.1\~3.3pH$. During the electroplating, the rate of diameter increase was measured every minute. To investigate uniformity, the diameter was measured at three different locations of each wire specimen aster electroplating. An X-ray diffraction test was performed to analyze the nature of the electroplated metal. Following heat treatment to improve adhesion between the wire and electroplated metal, a three-point bending test was conducted to compare stiffness, field strength, and ultimate strength among four wire groups; 0.016 inch, electroplated 016, electroplated and heat-treated 016, and 0.018 inch wires. Through the comparison of each wire group, following results were obtained. 1. In the load-deflection graph, the curve of the electroplated group was Placed between that of the 0.016 inch group and the 0.018 inch group, and the owe was closer to the 0.018 inch group by heat treatment. 2. In the electroplated and heat-treated 016 wire group, the values of stiffness, yield strength and ultimate strength showed higher tendency than in the original 0.016 Inch group. Stiffness and ultimate strength showed statistically significant differences between two groups. 3. Stiffness, yield strength, and ultimate strength of electroplated wire presented lower values than those of 0.018 inch wire group. 4. Stiffness, yield strength, and ultimate strength of electroplated and heat-treated wire showed higher tendency than those of electroplated wire group, and ultimate strength showed statistically significant difference between two groups. 5. After electroplating, the difference in diameter between the three locations was within $0.1\~0.3\%$ variation, and showed no statistical significance.

Shear bond strength of rebonded orthodontic bracket with flowable resin (Flowable resin을 이용한 브라켓의 재접착 시 전단결합강도에 대한 연구)

  • Kim, Dong-Woo;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.207-215
    • /
    • 2005
  • This study was performed to evaluate clinical practicality of the rebonding method with flowable resin without the removal of the residual resin on the debonded theeth and debonded bracket base after debonding. The samples of the control group (group I) were rebonded with Transbond XT using the usual rebonding method after the residual resin was removed. At experimental group, the brackets were rebonded with Transbond XT(group II) and CharmFil Flow (group III) without removal of residual resin which is the possibility becoming the index (or rebonding to similar position With initial bonding. The Shear bond Strength of the each group was measured. Patterns of bonding failure were evaluated with modified ARI score. and the shear bond strength according to patterns of bonding failure at experimental group was compared. Between the control group $(6.51\pm1.21MPa)$ and the group II rebonded with Transbond XT $(6.30\pm1.01MPa)$ did not have significantly difference in the shear bond strength (p=0.534), and the shear bond strength of group II was Significantly lower 4han the group III rebonded With CharmFil Flow $(7.29\pm1.54 MPa)$ (P=0.009). At control group, there was not large difference if distribution of bending failure pattern. But at experimental group, bond failure did not occur in interface between the resin-enamel. and bond failure between the resin-bracket, within the resin was distributed similarly. There was not significantly difference in the shear bond strength according to patterns of bonding failure at experimental group (P>0.05) The result of this study showed that the method suggested in this study aid flowable resin as rebonding adhesive could be useful in clinically.

A comparative study of electroplating and electroless plating for diameter increase of orthodontic wire (교정용 선재의 직경 증가를 위한 전기도금법과 무전해도금법의 비교연구)

  • Kim, Jae-Nam;Cho, Jin-Hyoung;Sung, Young-Eun;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.145-152
    • /
    • 2006
  • The purpose of this study was to evaluate electroless plating as a method of increasing the diameter of an orthodontic wire in comparison with eletroplating. After pretreatment plating of the 0.016 inch stainless steel orthodontic wire, electroless plating was performed at $90^{\circ}C$ until the diameter of the wire was increased to 0.018 inch. During the process of electroless plating, the diameter of the wire was measured every 5 minutes to examine the increasing ratio of the wire's diameter per time unit. And to examine the uniformity, the diameter at 3 points on the electroless-plated orthodontic wire was measured. An X-ray diffraction test for analyzing the nature of the plated metal and a 3-point bending test for analyzing the physical property were performed. The electroless-plated wire group showed a increased tendency for stiffness, yield strength, and ultimate strength than the electroplated wire group. And there was a statistically significant difference between the two groups for stiffness and ultimate strength. In the electroless-plated wire group, the increasing ratio of the diameter was $0.00461{\pm}0.00003mm/5min$ (0.00092 mm/min). In the electroplated wire group, it was $0.00821{\pm}0.00015mm/min$. The results of the uniformity test showed a tendency for uniformity in both the plating methods. The results of this study suggest that electroless plating of the wire is closer to the ready-made wire than electroplating wire in terms of the physical property. However, the length of plating time needs further consideration for the clinical application of electroless plating.

평행식 진동탄환 암거 천공기의 연구 (IV)(V)-실기 설계 제작 및 보장실험-Development of Balanced-Type Oscillating Mole Drainer(IV)(V)

  • 김용환;이승규;서상용
    • Journal of Biosystems Engineering
    • /
    • v.2 no.1
    • /
    • pp.7-24
    • /
    • 1977
  • This paper is the forth and fifth one of the study on balanced type oscillating mole drainer. In the light of the results from previous reports about the model tests, some design criteria were established and a prototype machine was set up for experimental purpose. Motion characteristics and functionof the each parts of the machine were checked and analyzed. After that, performance tests of the prototype machine were carried out in thefield. Obtained results are summarized as follows ; 1. Ten centimeter of the bullet diameter was determined so as to be able to attach it to the tractors with capacity of 30 PS to 40 PS. 2. To maintain the balance between the moments of the front shank and rear shank, the oscillating amplitude of the rear bullet was determined to be larger than that of the front bullet. At the same time , the oscillating direction of the rear bullet was designed with the inclines of ten to thirty degrees. 3. An octagonal dynamo transduced was developed for measuring the compressive force of the upper link is measuring the draft force of the machine. Acceptable linear relationship between forces and strain responses from O.D.T. was obtained. 4. Analysing the balancing mechanism of the acting part of the machine , it was found that the total draft force of the machine was equal to the difference between the sum of the draft force produced from the right and left side bending moments of the lower drawber and the compressive force on the upper link. 5. There are acceptable linear relationship between the strain and twisting moment by driving shaft, and between strain and shank moment. Above results enable us to carry out the field experiment with prototype machine. 6. When the test machine was used in the field, it was possible to reduce the oscillating acceleration by forty percent in average as compared it with the single bullet mole drainer. 7. When the test machine was used under the oscillating condition, the dratt torce was reduced by 27 percent to 59 percent as compared it with the test machine under non-oscillating condition, while the draft force was increased by 7 percent to 20 percent as compared it with the mole drainer having oscillating single bullet. The reasoning behind this fact was considered as the resistance force due to the rear shank and bullet. 8. As the amplitude and frequency of the bullet were increased, the torque was increased accordingly. This tendency could be varied with the various characteristics of the given soils. And the larger frequency and amplitute, the more increasing oscil\ulcornerlating power but decreasing draft brce were needed, and draft force was increased as the velocity was increased.9. When the amplitude of the rear bullet was designed to be larger than that of the front bullet, the minimum value of the moment was lowered and oscillating acceleration was reduced. And when the oscillating direction of the rear bullet was declined back\ulcornerwards, oscillating acceleration was increased along with the increasing angle of decli\ulcornernation. When the test machine was operated in high speed, the difference between maximum moments and minimum ones became narrow. This varying magnitude of moments appeared on the moment oscillogram seems to be correlated to the oscillating acceleration and draft force. 10. From the analysis of variance, it was found that those factors such as frequency, amplitude, and operating velocity significantly affected in the oscillating acceleration, the draft resistance, the torque, the moment, and the total power required. And interaction between frequency and amplitude affected in the oscillating acceleration. 11. Within the given situation of this study, the most preferable operating conditions of the test machine were 7 Hz in oscillating frequency, 0.54 m/sec in operating velocity, and 39.1 mm in oscillating amplitude of front and rear bullets. However, it is necessary to select the proper frequency and magnitude of oscillation depending on the soil properties of the field in which the mole drainer is practiced by use of a bal1nced type oscillating mole drainer. 12. It is recommended that a comparative study of the mole drainers would be performed in the near future using two separate balanced oscillating bullet with the one which is operated by oscillating the movable bullet in a single cylinder or other balanced type which may be single oscillating bullet with spring, damper or balancing weight, and that of thing. To expand the applicability of the balanced type oscillating mole drainer in practical use, it is suggested to develop a new mechanism which perform mole drain with vinyl pipe or filling material such as rice hull.

  • PDF

A Study on the Mechanical and Physical Properties of Sawdustboard combined with Plastic Chip (플라스틱칩 결체(結締) 톱밥보드의 기계적(機械的) 및 물리적(物理的) 성질(性質)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Suh, Jin-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.44-55
    • /
    • 1987
  • In order to study the effect of sawdustboard combined with plastic chips, 0.5mm($T_1$), 1mm($T_2$), 1.4mm($T_3$) thick nylon fiber. polypropylene rope fiber(RP), and 0.23mm thick moth-proof polypropylene net fiber(NP) were cut into 0.5, 1, 2cm long plastic chips. Thereafter, sawdustboard combined with plastic chips prepared as the above and plastic non-combined sawdustboard(control) were manufactured into 3 types of one-, two-, and three layer with 5 or 10% combination level. By the discussions and results at this study, the significant conclusions of mechanical and physical properties were summarized as follows: 1. The MORs were shown in the order of 3 layer> 2 layer> 1 layer among plastic non-combined boards, and $T_3$ < $T_2$ < $T_1$ < RP (NP(5%) < NP(l0%) among plastic combined boards. In 2cm long plastic chip in 1 layer board, the highest strength through all the composition was recognized. 1 layer board showing the lower strength with 0.5cm plastic chip rendered to the bending strength improvement by 2 or 3 layer board composition. On the other hand, 2 or 3 layer combined with 1, 2cm long polypropylene net fiber chips incurred MOR's conspicuous decrease requiring optimum plastic chip combined level and consideration to combined type. 2. MOE in plastic non-combined 3 layer board exhibited sandwich construction effect by higher resin content application to surface layer in the order of 3layer>1layer>2layer with the highest stiffness of the board combined with polypropylene chip, while nylon chip-combined board had little difference from plastic non-combined board. In relevant to length and layer effect, 3 layer board combined with the 0.5cm long polypropylene net fiber chip in 5% and 10% combined level presented 34-43% and 44-76% stiffness increase against plastic non-combined board(control), respectively. Moreover, in 1 layer board, 30% stiffness increase with 10% against 5% combined level in the 1 and 2cm long polypropylene net fiber chip was obtained. 3. Stress at proportional limit(Spl) showing the fiber relationship (r: 0.81-0.97) between MOR presented in the order of 1 layer<2 layer<3 layer in plastic non-combined board. Correspondingly, combined effect by layer and plastic chip length was similar to MOR's. 4. Differently from previous properties(MOR, MOE, Spl). work to maximum load(Wml) of 2 layer board approached to that of 3 layer board. Conforming the above phenomenon. 2 layer combined with 0.5cm long polypropylene net fiber chip kept the greater work than 1 layer. The polypropylene combined board superior to nylon -and plastic non - combined board seemed to have greater anti - failing capacity. 5. Internal bond strength(IB), in contrast to MOR's tendency. showed in the order of T1

  • PDF

Comparative Study on Mechanical Properties and Dimensional Stability of Staypak and Wood-Polymer Composites from Populus alba × P. Glandulosa wood (현사시나무로 제조(製造)된 열압축목재(熱壓縮木材)와 목재(木材)-고분자(高分子) 복합체(複合體) 재질(材質)의 비교연구(比較硏究))

  • Pak, Sang-Bum;Ahn, Won-Yung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.14-34
    • /
    • 1985
  • One of the techniques for altering the properties of wood that has received considerable attention in the last twenty years is the formation of a wood-polymer composite (WPC) by irradiation and heat-catalyst polymerization of a monomer incorporated into the wood matrix. Wood-polymer composites are the new products having the superior mechanical and physical properties and the combinated characteristics of wood and plastic. The purpose of this experiment was to obtain the basic data for the improvement of wooden materials by manufacturing WPC and Staypak. The species examined was Hyunsasi-Namoo (Populus alba ${\times}$ P. glandulosa) which had not been utilized yet. Methylmethacrylate (MMA) as monomer, benzoyl peroxide (BPO) as initiator and methyl alcohol as bulking agent were used. The monomer containing BPO was impregnated into wood pieces by the dipping and the vacuum process for 2 hours. After impregnation, the treated samples were polymerized on the hot press with pressure and heat-catalyst methods. The results obtained were summarized as follows 1. The monomer loading into wood by the dipping process was 12.13 percent and 29.99 percent by the vacuum. The polymer loading into wood by the dipping process was 6.79 percent and 15.44 percent by the vacuum. 2. Comparing with Staypak, antishrink efficiency (ASE) of WPC was 12.5 to 13.6 percent on the radial direction and 14.70 to 18.63 percent on the tangential. Antiswelling efficiency (AE) was 14.40 to 17.22 percent on the radial direction and 17.18 to 42.1 8 to 42.14 percent on the tangential. Reduction in water absorptivity (RWA) was 8.19 to 15.5 percent. As a whole, the vacuum process was better than the dipping. 3. The specific gravity of control, Staypak and WPC were 0.44, 0.66 and 0.61 to 0.62, respectively. 4. In the bending strength test, the strength in case that the load direction is on the radial surface was greater than that which the load direction is on the tangential. 5. Increasing rate of stress at proportional limit in compression perpendicular to grain was 72.26 percent in case of WPC by the dipping process, 78.93 percent by the vacuum and 99.09 percent in case of Staypak.

  • PDF