• Title/Summary/Keyword: Bellows-type

Search Result 34, Processing Time 0.028 seconds

Vacuum system design using the shear stress limit of clamp and the axial stress associated with bellows contraction (Bellows 수축에 따른 축방향응력과 clamp의 전단응력한계를 이용한 진공 system 설계)

  • Jeong, Jin-Yong;Yu, Yeong-Gun;Im, Jin-Hyeong;Kim, Hyeong-Ju;Choe, Yong-Seop;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.306-307
    • /
    • 2014
  • 진공용 장비의 sealing 방법으로 Cu gasket을 이용한 CF type과 O-ring을 이용한 NW type이 있다. 이중 O-ring을 이용한 sealing 방법에는 clamp를 사용하게 되는데 Al 합금으로 제작된 clamp에 bellows의 수축 시 받는 전단응력과 전단응력한계 이상의 힘을 받았을 때의 clamp 파손에 따른 역압에 의한 TMP 손상 분석.

  • PDF

A study on influence of vehicle interior noise according to design parameters of thermoplastic turbo charger intake hose (열가소성 플라스틱 흡기 터보차져호스의 설계 변수에 따른 차량 실내 소음에 미치는 영향에 관한 연구)

  • Jin, Yong-Sun;Youn, Jee-Young;Lee, Choon-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.367-368
    • /
    • 2012
  • In resent years, engineering thermoplastics represent a means for designers to integrate parts, facilitate assembly, reduce weight and lower the costs of their parts to improve the fuel efficiency and competitiveness of the cars. Thermoplastic turbo charger intake hose is one of most sophisticated application in thermoplastics under the hood. Used as part of weight & cost reduction and performance improvement program, thermoplastic turbo charger intake hose has been developed as rubber and metal replacement. For optimized product, NVH performance is a important criteria while keeping same durability required with current system. Though a number of studies have been conducted on the resonator hose and its analytical models, the most of studies were focused on transmission loss itself. This paper presents contribution of vehicle interior noise according to design parameters like profile, bellows type, bellows position, material characteristic. And we will review the design guidance for optimized product of thermoplastic turbo charger intake hose.

  • PDF

Studies on Piston Seal Mechanism of Stirling Engine (스터링 기관의 피스톤 밀봉 기구에 관한 연구)

  • Kim, T.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.4
    • /
    • pp.305-313
    • /
    • 1992
  • Dynamic seals have been continue to be one of the major technical problems facing stirling engine designers. Most of the modern engines use some version of the dry ring seal for piston and displacer seals. Friction power losses associated with seals are typically several percent of gross output power, with piston ring seals usually being the main contributor. Much effort has been expended to develop the seal mechanism of piston, but the performance of these seal devices is very poor. This study was conducted to examine the efficiency of the various types of the trial-made piston seal mechanism with reference to leakage of working fluid and friction losses. This paper described the successful hardware implementation of a stainless steel bellows element in stirling engine application with test data in power performance. The indicated power by use of the bellows was more than two times as that by use of the piston ring types. As the result of this study, bellows was provide as a reliable and efficient seal mechanism for any stirling engine application.

  • PDF

Pressure Regulation System for Optimal Operation of the Pneumatic VAD with Bellows-Type Closed Pneumatic Circuit (벨로우즈 방식의 폐회로를 가진 공압식 심실 보조장치의 최적 작동을 위한 압력 조절 시스템)

  • Kim, Bum-Soo;Lee, Jung-Joo;Nam, Kyung-Won;Jeong, Gi-Seok;Ahn, Chi-Bum;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.569-576
    • /
    • 2007
  • Ventricular Assist Device(VAD) has switched its goal from a short-tenn use for bridge-to-transplantation to a long-tenn use for destination therapy, With this goal, the importance of long-tenn reliability gets more interests and importances, H-VAD is an portable extracorporeal biventricular assist device, and adopts an electro-pneumatic driving mechanism. The pneumatic pressure to pump out blood is generated with compression of bellows, and is transmitted in a closed pneumatic circuit through a pneumatic line. The existing pneumatic VAD adopts a air compressor which can generate stable pressures but has defects such as a noise and a size problem. Thus, it is not suitable for being used as a portable device, These problems are covered with adopting a closed pneumatic circuit mechanism with a bellows which has a small size and small noise generation, but it has defects that improper pneumatic setting causes a failure of adequate flow generation. In this study, the pneumatic pressure regulation system is developed to cover these defects of a bellows-type pneumatic VAD. The optimal pneumatic pressure conditions according to various afterload conditions for an optimal flow rate were investigated and the afterload estimation algorithm was developed, The final pneumatic regulation system estimates a current afterload and regulate the pneumatic pressure to the optimal point at a given afterload condition. The afterload estimation algorithm showed a sufficient performance that the standard deviation of error is 8.8 mmHg, The pneumatic pressure regulation system showed a sufficient performance that the flow rate was stably governed to various afterload conditions. In a further study, if a additional sensor such as ultrasonic sensor is developed to monitor the direct movement of diaphragm in a blood pump part, the reliability would be greatly increased. Moreover, if the afterload estimation algorithm gets more accuracy, it would be also helpful to monitor the hemodynamic condition of patients.

A Study on Frequency Characteristics According to the Output Transmission Method of Round Window Driving Middle Ear Implants (정원창 구동형 인공중이의 출력 전달 방식에 따른 주파수 특성 연구)

  • Seong, KiWoong;Shin, DongHo;Na, SungDae;Lee, JyungHyun;Kim, MyoungNam;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.183-187
    • /
    • 2018
  • In this paper, we investigated the efficiency according to the output transmission method of the round window driving type AMEIs (active middle ear implants) through the cadaveric experiment. For the experiment, we fabricated DRT (direct rod transducer) and FMT (floating mass transducer) type vibrational transducers based on our previous studies and conducted their output characteristics were measured. TCBT (tri-coil bellows transducer) and DFMT (differential floating mass transducer) were implemented with the same driving force and electrical characteristics as one of DRT and FMT, respectively. In the experiment using three human temporal bone, normal stapes vibration was measured with 1 Pa in front of tympanic membrane, and then was compared with each output of transducers. From the comparison, the DRT type vibration transducer was superior in overall energy transfer efficiency, especially in the low frequency range. There was no difference in implantation difficulty between the two transducers. The results of this study suggest that the DRT type vibrational transducer is more efficient and needs further study to overcome the low frequency degradation in round window approaching with FMT.

Apparatus and Method for Wave Energy Convertor using Under-water Pressure Oscillation (해수압 진동을 이용한 파력발전 장치 및 방법)

  • Song, Seung-Kwan;Park, Jin-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2260-2264
    • /
    • 2011
  • This paper describes the development of an wave energy convertor. We devise a new type of the wave energy convertor which generates electricity by means of under-water pressure oscillation. This wave energy convertor is installed on the seabed floor. That is, there is no exposed body on the surface of the sea. The wave energy convertor comprises an activated assembly which is adapted to be displaced in response to water pressure oscillation to vary the volume of bellows cavity and a power take off assembly which generates electricity in response to movement of the activated assembly.

Development of Eco-Environmental On/Off Diaphragm Valve (친환경 온/오프 다이어프램 밸브 개발)

  • Cheong, Seon-Hwan;Choi, Seong-Dae;Klm, Shin-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.4
    • /
    • pp.28-35
    • /
    • 2007
  • Currently, most of all valves using at the semiconductor & LCD manufacturing process are packless type. Such valves are needed to have the functions to protect perfectly from the leakage of fluid by using bellows and diaphragm instead of the grand packing. But not only those valves made in Korea are not available at this point, but also advanced foreign manufacturers do not open enough their data on the basic technology. Otherwise although they open the data a little, they are almost data about stainless steel for pneumatic valves. In this paper, it was focused on the fluid valves for chemical & DI water based on the data of steel valves which are already using commercially. And also this study concentrated to collect the basic developing data of Eco-On/Off diaphragm valve by ourselves.

  • PDF

Prediction of Flow coefficient according to accuracy of opening Bellows Seal Valve (벨로우즈 실 밸브의 개폐정도에 따른 유량계수의 예측)

  • Song, Xueguan;Kang, Jung-Ho;Kim, Seung-Gyu;Park, Young-Chul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.4
    • /
    • pp.3-7
    • /
    • 2007
  • The valve is used on control of flow in a ship. Flow coefficient of valve is very importance in the design of valve. In this paper, three-dimensional computer simulations by commercial code CFX were conducted to observe the valve type and to measure flow coefficient when valves with various angles and uniform incoming velocity were used in a piping system. By contrast, a group of experimental data is used to compare with the data obtained by CFX simulation to investigate the validity of numerical method.

  • PDF

The Characteristics of the Composite Ground with Sand Compaction Pile(SCP) using Large Soil Box (대형토조시험을 이용한 모래다짐말뚝이 적용된 복합지반의 침하 및 하중전이특성)

  • Kim, Oo-Seok;Park, Eon-Sang;Kim, Jae-Kwon;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.974-981
    • /
    • 2005
  • Because general laboratory tests for sand compaction pile method including unit-cell test device have fixed outside diameter, as area replacement ratio increase, diameter of sand pile increase. These condition can bring about overestimation of stiffness of composite ground. In addition, existing large soil box which consist of bellows type loading plate can occur serious mistake in checking the amount of drained water because there are additional drainage along the inside wall in device. Overcoming these shortcoming, this paper developed modified large scale soil box consist of piston type load plate. In this study, using this device, series of modified large scale soil box tests were performed, and investigated the settlement and stress transportation characteristics with area replacement ratio in sand compaction pile method.

  • PDF

The Development of Exercise Therapy Protocol Applied to an Efficacy Expectation Promoting Program in Type 2 Diabetes Mellitus Patients (효능기대증진 프로그램을 적용한 운동요법 프로토콜 개발 - 제 2 형 당뇨병 환자를 중심으로 -)

  • Hwang Ae-Ran;Kim Chun-Ja
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.3
    • /
    • pp.366-378
    • /
    • 2000
  • Type 2 Diabetes Mellitus patients have chronic metabolic disorder and they need self care for their lifetime. But most Diabetes Mellitus patients don't know how to do a self care due to the lack of adequate support from health care professionals. It has been reported that lack of exercise therapy compliance guide is very important one. This study was conducted to develop an exercise therapy protocol applied to an efficacy expectation promoting program based on Bandura's self efficacy model for type 2 Diabetes Mellitus patients. Firstly, a conceptual framework was developed through efficacy expectation promoting Program based on Bandura's self efficacy model. In order to identify the contents of program and to design a preliminary protocol, a with the consultation experts was made. A clinical validity was tested using twenty type 2 Diabetes Mellitus patients who received follow-up care regularly through the diabetic out-patient clinic from October, 1998 to May, 2000. After this process, the final protocol was developed. The results of this study are summarized as bellows : The final exercise therapy protocol applied to an efficacy expectation promoting program for type 2 Diabetes Mellitus Patients consists of individualized exercise test and prescription, a small booklet relating personal experience with Diabetes Mellitus and a telephone coaching program for 12 weeks on performance accomplishment, vicarious experience and verbal persuasion, which are all induction modes of efficacy expectation. It is concluded that the exercise therapy protocol applied to an efficacy expectation promoting program is applicable to type 2 diabetes mellitus. And this exercise therapy protocol could show a positive effect on the exercise compliance of Diabetes Mellitus patients.

  • PDF