• Title/Summary/Keyword: Bearing capacity increase ratio

Search Result 129, Processing Time 0.021 seconds

Bearing Capacity of Waste Landfill Reinforced by Geosynthetics (토목섬유로 보강된 폐기물 매립지반의 지지력 특성)

  • Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.3
    • /
    • pp.39-46
    • /
    • 2007
  • Many industrialized countries of the world have many problems about the reuse of waste landfill area because the increase of terminated waste disposal landfill. Especially, the effective use of the terminated waste disposal landfill nearby the urban area has been demanded, because of the lack of the usable land. However, the reuse of terminated waste disposal landfill site is needed an adequate stabilization of ground for increasing the bearing capacity and reduce the allowable settlement for the given structure. This study is to evaluate the applicability of geosynthetics for the increment of bearing capacity of solid waste landfill ground. The in-situ cyclic plate loading tests were performed to determine the dynamic and static behaviors of reinforced ground with geosynthetics. Four series of test were conducted with variations of geosynthetics, number of geogrid layer. Based on the cyclic plate load test results, the bearing capacity ratio, subgrade modulus of ground, and the elastic rebound ratio were determined.

  • PDF

A Study on the Estimation of Ultimate Bearing Capacity of Granular Group Piles Reinforced with Steelpipe Skirts (강관스커트 보강 조립토 군말뚝의 극한지지력 평가에 관한 연구)

  • 김홍택;황정순;강인규;고용일
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.79-98
    • /
    • 1999
  • In the present study, a simple finite element method of analysis to predict non-uniform settlements at the interface between the mat foundation and foundation soils is proposed. Based on the proposed finite element method of analysis, the method to evaluate load sharing ratios of the foundation soils adjacent to the granular group piles is also presented. Further proposed is a procedure to estimate ultimate bearing capacity of the skirted granular group piles in a square pattern. To verify validity of the proposed methods and the estimated ultimate bearing capacity of the skirted group piles, comparisons are made with the results analyzed by using the PENTAGON3D FEM program. Finally, behavior characteristics with different reinforcement patterns of the skirts and the effect of an increase of ultimate bearing capacity due to the skirts are analyzed in connection with the design parameters.

  • PDF

Research on seismic performance of regionally confined concrete circular column with trapezoid stirrups

  • Longfei Meng;Hao Su;Yanhua Ye;Haojiang Li
    • Steel and Composite Structures
    • /
    • v.51 no.6
    • /
    • pp.587-600
    • /
    • 2024
  • In order to investigate the seismic performance of regionally confined concrete circular column with trapezoid stirrups (TRCCC) under high axial compression ratio, the confinement mechanism of regionally confined concrete was analyzed. Three regionally confined concrete circular columns with trapezoid stirrups were designed, and low cyclic loading tests were conducted at three different axial compression ratios (0.9, 1.1, 1.25) to study the failure mode, hysteresis curve, skeleton curve, deformation capacity, stiffness degradation and energy dissipation capacity of the specimens. The results indicate that the form of regional confinement concrete provides more uniform confinement to the normal confinement, and the confinement efficiency at the edges is 1.4 times that of normal confined concrete. The ductility coefficients of the specimens were all greater than 3 under high axial compression ratios, and the stiffness and horizontal bearing capacity increased with the increase of axial compression ratio. Therefore, it is recommended that the code of design specifications can appropriately relax the axial compression ratio limit for TRCCC. Finally, the spacing between stirrups of TRCCC was analyzed using ABAQUS software. The results showed that as the spacing between the stirrups decreased, the cracking load and peak load of TRCCC increased continuously, but the rate of increase decreases.

Eccentric performance of CFST columns jacketed with steel tube and sandwiched concrete

  • Weijie Li;Yiyan Lu;Yue Huang;Shan Li
    • Steel and Composite Structures
    • /
    • v.48 no.1
    • /
    • pp.89-102
    • /
    • 2023
  • This study investigates the eccentric performance of concrete-filled steel tubular (CFST) stub columns strengthened with steel tube and sandwiched concrete (STSC) jackets. It was revealed that the STSC jacketing method effectively weakened the cracking of concrete in CFST columns on the convex side and the crash on the concave side. Substantial increases in the eccentric bearing capacities were demonstrated after strengthening. A numerical study was further conducted. The decrease in diameter-to-thickness ratio and increase in strength of outer tube contributed to increase in peak load of all components, whereas the increase in sandwiched concrete strength resulted in load increase on itself and had negligible effects on other components. The parametric study showed the effect of inner concrete strength on columns' bearing capacity was magnified after strengthening, whereas that of inner tube thickness was reduced. Within the parameters investigated, high-strength concrete and high-strength steel can be applied without the concern of early abrupt failure of inner low-strength concrete or steel tube.

Horizontal Bearing Characteristics of Micropiles with the Length Ratio and Installation Angle of Pile (파일길이비와 파일설치각도에 따른 마이크로파일 수평지지특성)

  • Oh, Joung-Bae;Hwang, Tae-Hyun;Huh, In-Goo;Shin, Jong-Ho;Kwon, Oh-Yeob
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.6
    • /
    • pp.5-13
    • /
    • 2015
  • Micropile was mainly used as one of underpinnig methods, and recently has been used for the various purposes such as foundation for new structure or slope stability etc. However, despite of the increase of the usage of micropile, studies about the horizontal bearing characteristic of micropile are insufficient. Thus the model test has been conducted to investigate the horizontal bearing characteristics of micropile with the length ratio and installation angle of pile. Consequently, micropiles at the installation angle of $+30^{\circ}$ and $-30^{\circ}$ effectively increase the horizontal bearing capacity, respectively for L/d ${\leq}25$ and L/d > 50.

Experimental and analytical research on geopolymer concrete beams reinforced with GFRP bars

  • Suleyman Anil Adakli;Serkan Tokgoz;Sedat Karaahmetli;Cengiz Dundar
    • Structural Engineering and Mechanics
    • /
    • v.91 no.4
    • /
    • pp.335-347
    • /
    • 2024
  • This paper presents the behavior of geopolymer concrete beams reinforced with glass fiber reinforced polymer (GFRP) bars. In the study, ordinary Portland cement concrete and geopolymer concrete beams having GFRP bars were prepared and tested under four-point loading. The load-deflection diagrams and load capacities of the tested beams were obtained. It was observed that the tested beams exhibited good ductility and significant deflection capacity. The results showed that increasing the tension GFRP reinforcement ratio caused enhancement in the strength capacity of geopolymer concrete beams. In addition, the tested beams were analyzed to obtain the load capacity and the load-deflection responses. The theoretical load-deflection curves and load bearing capacities have been predicted well with the test results. Parametric study has been performed to determine the influences of concrete strength, shear span to depth ratio (a/d) and reinforcement ratio on the behavior of geopolymer concrete beams longitudinally reinforced with GFRP bars. It was concluded that increasing concrete strength led to an increase in load capacity. Besides, the ultimate load increased as the reinforcement ratio increased. On the other hand, increasing a/d ratio reduced the ultimate load value of GFRP reinforced geopolymer concrete beams.

A Study on Determining the Design Parameter ($N_c$, $T_i$) of the Surface Reinforcement Method for Soft Ground (연약지반 표층처리공법 설계정수(지지력계수$N_c$, 인장력$T_i$) 산정방법에 관한 고찰)

  • Ham, Tae-Gew;Seo, Se-Gwan;Cho, Sam-Deok;Yang, Kee-Sok;You, Seung-Kyong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.750-758
    • /
    • 2009
  • This study, as basic research which was intended to develope the surface reinforcement method using reinforcement material which is applicable to very soft ground in Korea, was aimed at proposing the design parameter for the surface ground improvement method. To that end, a wide width tensile test using geotextile, geogrid and steel bar (substitute for bamboo) and 25 kinds of the laboratory model tests with the end restraint conditions of the reinforcement that comprises the constrained and partially constrained (3 types) conditions were conducted. And the result indicated that the modulus of subgrade reaction or $N_c$ value (5.3) apparently overestimated the bearing capacity of very soft ground such as dredged ground. Moreover, as a result of model test by partially constraining the preload of 23.0kgf using geotextile, the effect of bearing capacity($q_1$) appeared to be the largest till the loading stress was $0.4tf/m^2$ due to cohesion, while it reached 75% of the maximum bearing force after $0.4tf/m^2$ due to increase in the effect of bearing capacity($q_2$) caused by the tensile force of the reinforcement. Such results tended to have appeared constantly or very similarly with each other, irrespective of the type of reinforcement (geogrid, steel bar) and constraint conditions.

  • PDF

A Study on the Behavior of Piled Raft Foundation Using Triaxial Compression Apparatus (삼축압축 시험기를 이용한 말뚝 지지 전면 기초 거동 연구)

  • 이영생;홍승현
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.387-395
    • /
    • 2003
  • Model tests were conducted to study the behavior of the piled raft foundation system on sands. Especially in this study, the method using the triaxial compression apparatus was devised and used to apply the confining pressure which is considered difficult in the existing model test on the soil. Steel rods (6mm dia.) and aluminum plates (8mm thickness, 50mm dia.) were used to simulate piles and rafts respectively. Jumunjin standard sands were used to ensure the homogeneity of the sample. After the sample with the piled raft model was laid inside the triaxial cell, the confining pressure was applied and then the compressive force was applied. The increase and/or decrease ratio of the bearing capacity, the load distribution ratio between raft and piles and the effect of settlements decrease depending on the confining pressure, the number of piles and the length of piles were analyzed and the bearing capacity and skin friction of the pile was calculated. By the results of these experiments, the bearing capacity increased and the settlement decreased with this piled raft foundation system. Especially the effect was larger with the increase of the number of piles than with the increase of length of piles. Hereafter, the study of the load transfer mechanism of piles under confining pressure would be made possible using these small model tester like triaxial compression apparatus.

Seismic behavior and strength of L-shaped steel reinforced concrete column-concrete beam planar and spatial joints

  • Chen, Zongping;Xu, Deyi;Xu, Jinjun;Wang, Ni
    • Steel and Composite Structures
    • /
    • v.39 no.3
    • /
    • pp.337-352
    • /
    • 2021
  • The study presented experimental and numerical investigation on the seismic performance of steel reinforced concrete (SRC) L-shaped column- reinforced concrete (RC) beam joints. Various parameters described as steel configuration form, axial compressive ratio, loading angle, and the existence of slab were examined through 4 planar joints and 7 spatial joints. The characteristics of the load-displacement response included the bearing capacity, ductility, story drift ratio, energy-dissipating capacity, and stiffness degradation were analyzed. The results showed that shear failure and flexural failure in the beam tip were observed for planar joints and spatial joint, respectively. And RC joint with slab failed with the plastic hinge in the slab and bottom of the beam. The results indicated that hysteretic curves of spatial joints with solid-web steel were plumper than those with hollow-web specimens. The capacity of planar joints was higher than that of space joints, while the opposite was true for energy-dissipation capacity and ductility. The high compression ratio contributed to the increase in capacity and initial stiffness of the joint. The elastic and elastic-plastic story deformation capacity of L-shaped column frame joints satisfied the code requirement. A design formula of joint shear resistance based on the superposition theory and equilibrium plasticity truss model was proposed for engineering application.

Research on damage of solid-web steel reinforced concrete T-shaped columns subjected to various loadings

  • Xue, Jianyang;Zhou, Chaofeng;Liu, Zuqiang
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.409-423
    • /
    • 2017
  • This paper presents an experimental study on damage evolution laws of solid-web steel reinforced concrete (SRC) T-shaped columns along the direction of the web under various loadings. Ten specimens with a scale ratio of 1/2 and a shear span ratio of 2.5 were designed and fabricated. The influences of various parameters, including the axial compression ratio, steel ratio, and loading mode, were examined. The mechanical performances including load-displacement curve and energy dissipation capacity under the monotonic and low cyclic loadings were analyzed. Compared with the monotonic loading, bearing capacity, ultimate deformation capacity, and energy dissipation capacity of the specimens decrease to some extent with the increase of the displacement amplitude and the number of loading cycle. The results show that the damage process of the SRC T-shaped column can be divided into five stages, namely non-damage, slight-damage, steadily-developing-damage, severe-damage and complete-damage. Finally, based on the Park-Ang model, a modified nonlinear damage model which combines the maximum deformation with hysteretic energy dissipation is proposed by taking into account the dynamic influence of the aforementioned parameters. The results show that the modified model in this paper is more accurate than Park-Ang model and can better describe the damage evolution of SRC T-shaped columns.