• 제목/요약/키워드: Beam-on time

검색결과 1,783건 처리시간 0.027초

DLC 박막을 이용한 Ion Beam 배향 TN 셀의 전기광학특성에 관한 연구 (A Study on Electro-Optical Characteristics of the Ion Beam Aligned TN Cell on the DLC Thin Film)

  • 황정연;조용민;노순준;이대규;백홍구;서대식
    • 한국전기전자재료학회논문지
    • /
    • 제15권8호
    • /
    • pp.726-730
    • /
    • 2002
  • Electro-optical (EO) performances of the ion beam (IB) aligned twisted-nematic (TN)-liquid crystal display (LCD) with ion beam exposure on the new diamond-like carbon (DLC) thin film surface were investigated. A good voltage-transmittance (V-T) curve of the ion beam aligned TN-LCD with oblique ion beam exposure on the DLC thin film surface for 1 min was observed. Also, the fast response time of the ion beam aligned TN-LCD with oblique ion beam exposure on the DLC thin film surface for 1 min can be achieved. Finally, the residual DC voltage of the ion beam aligned TN-LCD on the DLC thin film surface is almost the same as that of the rubbing aligned TN-LCD on a polyimide (Pl) surface.

Transient response of 2D functionally graded beam structure

  • Eltaher, Mohamed A.;Akbas, Seref D.
    • Structural Engineering and Mechanics
    • /
    • 제75권3호
    • /
    • pp.357-367
    • /
    • 2020
  • The objective of this article is investigation of dynamic response of thick multilayer functionally graded (FG) beam under generalized dynamic forces. The plane stress problem is exploited to describe the constitutive equation of thick FG beam to get realistic and accurate response. Applied dynamic forces are assumed to be sinusoidal harmonic, sinusoidal pulse or triangle in time domain and point load. Equations of motion of deep FG beam are derived based on the Hamilton principle from kinematic relations and constitutive equations of plane stress problem. The numerical finite element procedure is adopted to discretize the space domain of structure and transform partial differential equations of motion to ordinary differential equations in time domain. Numerical time integration method is used to solve the system of equations in time domain and find the time responses. Numerical parametric studies are performed to illustrate effects of force type, graduation parameter, geometrical and stacking sequence of layers on the time response of deep multilayer FG beams.

시간에 따라 변하는 회전 속도와 함께 회전하며 전개하는 보의 진동 분석 (Vibration Analysis of a Deploying and Spinning Beam with a Time-dependent Spinning Speed)

  • 주극비;정진태
    • 한국소음진동공학회논문집
    • /
    • 제25권12호
    • /
    • pp.874-880
    • /
    • 2015
  • This paper presents the vibration analysis of a deploying beam with spin when the beam has a time-dependent spinning speed. In the previous studies for the deploying beams with spin, the spinning speed was time-independent. However, it is more reasonable to consider the time-dependent spinning speed. The present study introduces the time-dependent spinning speed in the modeling. The Euler-Bernoulli beam theory and von Karman nonlinear strain theory are used together to derive the equations of motion. After the equations of motion are transformed into the weak forms, the weak forms are discretized. The natural frequency and dynamic response are obtained. The effect of the time-dependent spinning speed on the dynamic response is studied.

TomoTherapy: 치료 소요시간 및 영향 요인 분석 (TomoTherapy: Analysis of treatment time and influencing factor)

  • 손종기;강현성;황철환;서세정;최민호
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.119-128
    • /
    • 2017
  • 목 적: 본 연구의 목적은 TomoTherapy 치료시에 평균 실제 치료시간을 측정하고, 치료과정에서 실제 치료시간에 영향을 미치는 절차들의 소요시간을 조사하고자 한다. 환자 및 방법: TomoTherapy치료를 받은 31명의 환자를 대상으로 치료과정에서 절차에 의한 소요시간을 측정하였다. Beam-on time, Image registration time, 그리고 Set-up with scan time, Actual treatment time을 측정하고 단계적 선형 회귀분석을 수행하였다. 결 과: 치료부위 당 평균 실제 치료시간은 21.44 - 23.92분 이었다. Beam-on time, Image registration time, 그리고 Set-up with Scan time들이 실제치료 시간에 영향을 미치는 중요한 요인이었으며, 가장 큰 영향요인은 Beam-on time이었고, 그 다음으로 Set-up with Scan time이었다. 그리고 Image registration time은 영향이 적은 것으로 분석되었다. 결 론: TomoTherapy 치료환자 1명당 실제 치료시간은 평균 $22.68{\pm}3.37$분이었다. 정규시간 8시간 이내에 약 21명의 환자가 치료받을 수 있을 것으로 예상된다. 그러나 치료가 중단되거나 치료과정에서 절차의 진행시간이 달라지면, 일일 치료환자들의 스케줄에 영향을 미치며, 업무 부하량이 늘어날 것으로 생각된다.

  • PDF

Multilayered inhomogeneous beam under prescribed angle of twist and displacements: A delamination analysis

  • Victor I. Rizov
    • Coupled systems mechanics
    • /
    • 제13권2호
    • /
    • pp.153-170
    • /
    • 2024
  • The problem considered in this theoretical paper is the delamination of a multilayered inhomogeneous beam structure that has viscoelastic behaviour under angle of twist, horizontal and vertical displacements which vary smoothly with time according to prescribed laws. The cross-section of the beam is a rectangle. The layers are made of different materials which are smoothly inhomogeneous along the length of the beam. The beam under consideration represents statically undetermined structure since it is clamped in its two ends. The problem of the strain energy release rate is solved. For this purpose, the strain energy stored in the beam structure is analyzed. In order to verify the solution obtained, the strain energy release rate is found also analyzing the time-dependent compliances of the beam under prescribed angle of twist and displacements. A parametric investigation is carried-out by applying the solution obtained. Special attention is paid to the effect of the parameters which control the variation of the angle of twist and the displacements with time on the strain energy release rate.

a-C:H 박막을 이용한 액정 배향 효과 및 TN-LCD 의 전기광학 특성 (Liquid Crystal Alignment Effect and Electro-Optical Characteristics of TN-LCD on a-C:H Thin Films)

  • 황정연;조용민;노순준;백홍구;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.124-127
    • /
    • 2002
  • LC aligning capabilities and the variation of pretilt angles with ion beam irradiation on the a-C:H thin films, and electro-optical (EO) performances of the ion beam aligned twisted nematic (TN)-liquid crystal display (LCD) with oblique ion beam exposure on the a-C:H thin film were studied. A high pretilt angle of $3.5{^{\circ}}$ via ion beam irradiation on the a-C:H thin film was measured. Also, the LC pretilt angle decreased due to the increase in surface roughness at over 2 min of IB exposure time. It is considered that this roughness increase due to increasing IB exposure time that generated destroy of oriented rings of atoms related to LC alignment. An excellent voltage-transmittance (V-T) curve of the ion beam aligned TN-LCD was observed with oblique ion beam exposure on the a-C:H thin film for 1 min. Also, a faster response time for the ion beam aligned TN-LCD with oblique ion beam exposure on the a-C:H thin film for 1 min can be achieved. Finally, the residual DC property of the ion beam aligned TN-LCD with ion beam exposure of 1 min on the a-C:H thin film is almost same as that of the rubbing aligned TN-LCD on a PI surface.

  • PDF

레이저빔 직경변화에 대한 광경화성 수지의 경화특성 고찰 (Study of Cure Properties in Photopolymer for Stereolithography using Various Laser Bean Size)

  • 이은덕;김준안;백인환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1089-1092
    • /
    • 2001
  • In the stereolithography process, build parameters are laser power, scan velocity, scan width, bean diameter, layer thickness and so on. These values are determined according to product accuracy and build time. Build time can be reduced by improving of scan velocity, laser power, layer thickness, hatching space and so on. But variation of these parameters influence part accuracy, surface roughness, strength. This paper observed cure properties in various beam diameter. In order to examine these, relationships of scan velocity and cure depth, scan velocity and cure width according to various beam diameter in one scan line are measured. And cure thickness is measured according to beam diameter and scan velocity in scan surface of one layer. For reduction of build time, beam diameter and scan velocity is proposed in stereolithography process.

  • PDF

a-C:H 박막의 물성 변화에 따른 액정 배향 특성에 관한 연구 (A study on liquid crystal alignment characteristics by the properties of hydrogenated amorphous carbon thin films)

  • 이대규;노순준;백홍구;황정연;조용민;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.839-844
    • /
    • 2002
  • This letter focuses on the liquid crystal alignment characteristics according to the properties of hydrogenated amorphous carbon(a-C:H) thin film deposited by RPECVD(Remote Plasma Enhanced Chemical Vapor Deposition) method using $C_2H_2$ and He gases. The properties of the deposited thin films were controlled by the ion beam irradiation time and ion beam energy. The results show that not ion beam energy but ion beam irradiation time plays an important role in the properties of a-G:H thin films. As the ion beam irradiation time increases, not only the sp2 concentration in a-G:H thin films but also liquid crystal pretilt angle was varied.

  • PDF

빔-호핑 위성 전송 시스템을 위한 카운터 기반의 연속적인 beam allocation time schedule (BATS) 변경 기법 (Seamless beam allocation time schedule (BATS) change method based on counter for beam-hopping satellite transmission systems)

  • 오종규;오덕길
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송∙미디어공학회 2018년도 추계학술대회
    • /
    • pp.114-116
    • /
    • 2018
  • 본 논문에서는 빔-호핑 위성 전송 시스템을 위한 카운터를 기반의 연속적인 beam allocation time schedule (BATS) 변경 기법을 제안한다. 제안하는 기법은 BATS 를 처음 변경할 때, 카운터를 기반으로 gateway (GW)와 space craft (SC) 양단에서 BATS 변경 시점을 동기화 시킨다. 이 후, BATS를 계속 변경하더라도 전송 데이터 손실 없이 BATS 를 변경할 수 있다.

  • PDF

빔 위치 관련 제어인자가 집속이온빔 패턴 증착공정에 미치는 영향 (The Influence of Parameters Controlling Beam Position On-Sample During Deposition Patterning Process with Focused Ion Beam)

  • 김준현;송춘삼;김윤제
    • 대한기계학회논문집A
    • /
    • 제32권3호
    • /
    • pp.209-216
    • /
    • 2008
  • The application of focused ion beam (FIB) depends on the optimal interaction of the operation parameters between operating parameters which control beam and samples on the stage during the FIB deposition process. This deposition process was investigated systematically in C precursor gas. Under the fine beam conditions (30kV, 40nm beam size, etc), the effect of considered process parameters - dwell time, beam overlap, incident beam angle to tilted surface, minimum frame time and pattern size were investigated from deposition results by the design of experiment. For the process analysis, influence of the parameters on FIB-CVD process was examined with respect to dimensions and constructed shapes of single and multi- patterns. Throughout the single patterning process, optimal conditions were selected. Multi-patterning deposition were presented to show the effect of on-stage parameters. The analysis have provided the sequent beam scan method and the aspect-ratio had the most significant influence for the multi-patterning deposition in the FIB processing. The bitmapped scan method was more efficient than the one-by-one scan type method for obtaining high aspect-ratio (Width/Height > 1) patterns.