• Title/Summary/Keyword: Beam Radiation

Search Result 1,746, Processing Time 0.031 seconds

ML-6M선형 가속기에서의 BEAM 특성에 대한 고찰

  • Mun, Eon-Cheol;Yun, Byeong-Un;O, Yang-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.5 no.1
    • /
    • pp.115-119
    • /
    • 1992
  • The beam characteristics and dosimetric measurements of the 6MV X-ray and 6MeV electron beam from a ML-6M linear accelerator are examined. The Percent Depth Dose(PDD) table and the tissue Maximum Ratio(TMR) table are taken from measurement as a function of the field size and the depth. The calculated TMR table from PDD table is compared with those from measurement. Other beam characteristics such as output factor, beam profile(including flatness, symmetry and penumbra), wedge, and the variation of Dmax are presented. All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

Sound radiation of curved beam under the action of harmonic line forces (조화분포하중을 받는 원환보의 음향방사)

  • 지창헌
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.10-16
    • /
    • 1997
  • The problem of sound radiation from curved beam under the action of harmonic line forces is studied. The reaction due to fluid loading on the vibratory response of the curved beam is taken into account. The curved beam is assumed to occupy the plane y=0. The curved beam material and the elastic foundation are assumed to be lossless including a tension force(T), damping coefficient(C) and stiffness of foundation($k_s$) will be employed. The non-dimensional sound power is derived through integration of the surface intensity distribution over the entire curved beam. The expression for sound power is integrated numerically and the results are examined as a function of wavenumber ratio($\gamma$) and stiffness factor($\psi$).

  • PDF

Modified Transmission Line Type Antennal for the Beam Tilt (Beam Tilt를 위한 변형된 전송선로형 안테나)

  • 이종철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.2
    • /
    • pp.141-148
    • /
    • 1998
  • For developing a beam shaping antenna, the circumference and the length of the vertical and horizontal elements of the Modified Transmission Line type Antenna(MTLA) are varied. The vertical radiation pattern of MTLA which has various shape was analyzed by the moment method in order to verify the beam tilt characteristics. From the analysis, it is confirmed that the condition of the maximum beam tilt is determined by the length of the vertical elements of the antenna. The antennal with the maximum beam tilt was designed and its input impedance and the radiation pattern was calculated theoretically and measured experimentally.

  • PDF

Characteristics and Effects of Radiation Treatment on Wood Pulping Process (목재 펄프 제조 공정에서의 방사선 효과 및 특성)

  • Won, So Ra;Shin, Hye Kyoung;Jeun, Joon Pyo;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.227-230
    • /
    • 2011
  • Pulps were separated from wood chips using an Electron beam irradiation (EBI) treatment without a NaOH-AQ (anthraquinone) treatment for cooking. The methods were based on a hot water treatment after EBI and two-step bleaching processes. Chemical compositions and FT-IR spectroscopy demonstrated that the content of lignin and hemicellulose in the bleached wood pulps treated with various EBI dose decreased with an increase of EBI doses. Specifically, the lignin in the bleached with pulps treated at 600 kGy of EBI dose was almost completely removed. Moreover, TGA analysis showed that a thermal stability increased with increasing the content of cellulose but the lignin decomposed slowly over the wide region.

Morphological, Physical Characterization of Poly(acrylic acid) Nanogel Prepared by Electron Beam Irradiation

  • Park, Jong-Seok;Choi, Jong-Bae;Gwon, Hui-Jeong;Lim, Youn-Mook;Jeong, Sung-In;Shin, Young-Min;Kang, Phil-Hyun;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.29-34
    • /
    • 2014
  • Nanogels are internally cross-linked particles of sub-micrometer size made of hydrophilic polymers and are considered a distinct type of macromolecules, compared with linear and branched polymers or macroscopic gels. In this study, we studied a method of radiation induced synthesis of nanogels, which allows us to obtain tailored intra-molecularly crosslinked macromolecules of independently chosen molecular weight and dimensions. Thus, we report the possibility of applying the prepared nanogels using poly(acrylic acid) through electron beam irradiation for potential application as biomaterials. The nanogels were characterized by scanning electron microscopy (SEM). In addition, the size and zeta-potential of nanogels were measured by a particle size analyzer (PSA). The nanogels were prepared at an approximate size of 180 nm at 100 kGy and were spherical in shapes. The size of the nanogels decreased with increasing irradiation doses, and the absolute value of zeta potential increased with increasing irradiation doses.

History of the Photon Beam Dose Calculation Algorithm in Radiation Treatment Planning System

  • Kim, Dong Wook;Park, Kwangwoo;Kim, Hojin;Kim, Jinsung
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.54-62
    • /
    • 2020
  • Dose calculation algorithms play an important role in radiation therapy and are even the basis for optimizing treatment plans, an important feature in the development of complex treatment technologies such as intensity-modulated radiation therapy. We reviewed the past and current status of dose calculation algorithms used in the treatment planning system for radiation therapy. The radiation-calculating dose calculation algorithm can be broadly classified into three main groups based on the mechanisms used: (1) factor-based, (2) model-based, and (3) principle-based. Factor-based algorithms are a type of empirical dose calculation that interpolates or extrapolates the dose in some basic measurements. Model-based algorithms, represented by the pencil beam convolution, analytical anisotropic, and collapse cone convolution algorithms, use a simplified physical process by using a convolution equation that convolutes the primary photon energy fluence with a kernel. Model-based algorithms allowing side scattering when beams are transmitted to the heterogeneous media provide more precise dose calculation results than correction-based algorithms. Principle-based algorithms, represented by Monte Carlo dose calculations, simulate all real physical processes involving beam particles during transportation; therefore, dose calculations are accurate but time consuming. For approximately 70 years, through the development of dose calculation algorithms and computing technology, the accuracy of dose calculation seems close to our clinical needs. Next-generation dose calculation algorithms are expected to include biologically equivalent doses or biologically effective doses, and doctors expect to be able to use them to improve the quality of treatment in the near future.

Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study

  • Hwajung Lee;Do Hoon Oh;Lee Yoo;Minsoo Chun
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.100-106
    • /
    • 2023
  • Background: As breast tissue expanders consist of metallic materials in the needle guard and ferromagnetic injection port, irradiation can produce radioactivation. Materials and Methods: A CPX4 (Mentor Worldwide LLD) breast tissue expander was exposed using the Versa HD (Elekta) linear accelerator. Two photon energies of 6 and 10 MV-flattening filter free (FFF) beams with 5,000 monitor units (MU) were irradiated to identify the types of radiation. Furthermore, 300 MU with 10 MV-FFF beam was exposed to the CPX4 breast tissue expander by varying the machine dose rates (MDRs) 600, 1,200, and 2,200 MU/min. To assess the instantaneous dose rates (IDRs) solely from the CPX4, a tissue expander was placed outside the treatment room after beam irradiation, and a portable radioisotope identification device was used to identify the types of radiation and measure IDR. Results and Discussion: After 5,000 MU delivery to the CPX4 breast tissue expander, the energy spectrum whose peak energy of 511 keV was found with 10 MV-FFF, while there was no resultant one with 6 MV-FFF. The time of each measurement was 1 minute, and the mean IDRs from the 10 MV-FFF were 0.407, 0.231, and 0.180 μSv/hr for the three successive measurements. Following 10 MV-FFF beam irradiation with 300 MU indicated around the background level from the first measurement regardless of MDRs. Conclusion: As each institute room entry time protocol varies according to the working hours and occupational doses, we suggest an addition of 1 minute from the institutes' own room entry time protocol in patients with CPX4 tissue expander and the case of radiotherapy vaults equipped with a maximum energy of 10 MV photon beams.

Fabrication and Characterization of a Fiber-Optic Radiation Sensor for High Energy Electron Beam Therapy (치료용 고에너지 전자선 계측을 위한 광섬유 방사선 센서의 제작 및 특성 분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Lee, Bong-Soo;Yi, Jeong-Han;Tack, Gye-Rae;Cho, Hyo-Sung;Kim, Sin
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.332-336
    • /
    • 2006
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator for high energy electron beam therapy. The intensities of scintillating light from a fiber-optic radiation sensor are measured with different field size, electron beam energy and monitor unit of a clinical linear accelerator. To obtain percent depth dose(PDD), the amount of scintillating light is measured at different depth of polymethylmethacrylate(PMMA) phantom. Also the intensity of Cerenkov light is measured and characterized as a function of incident angle of electron beam and a subtraction method is investigated using a background optical fiber to remove a Cerenkov light.

Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation (전신방사선조사(Total Body Irradiation) 시 Beam Spoiler와 환자 간의 거리에 관한 고찰)

  • Choi, Jong-Hwan;Kim, Jong-Sik;Choi, Ji-Min;Shin, Eun-Hyuk;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.51-54
    • /
    • 2007
  • Purpose: Total body irradiation is used to kill the total malignant cell and for immunosuppression component of preparatory regimens for bone-marrow restitution of patients. Beam spoiler is used to increase the dose to the superficial tissues. This paper finds the property of the distance between beam spoiler and patient. Materials and Methods: Set-up conditions are 6 MV-Xray, 300 MU, SAD = 400 cm, field size = $40{\times}40cm^2$. The parallel plate chamber located in surface, midpoint and exit of solid water phantom. The surface dose is measured while the distance between beam spoiler and patient is altered. Because it should be found proper distance. The solid water phantom is fixer and beam spoiler is moving. Results: Central dose of phantom is 10.7 cGy and exit dose is 6.7 cGy. In case of distance of 50 cm to 60 cm between beam spoiler and solid water phantom, incidence dose is $14.58{\sim}14.92cGy$. Therefore, The surface dose was measured $99.4{\sim}101%$ with got near most to the prescription dose. Conclusion: In clinical case, distance between beam spoiler and patient affect surface dose. If once $50{\sim}60cm$ of distance between beam spoiler and patient, surface dose of patient got near prescription dose. It would be taken distance between beam spoiler and patient into account in clinical therapy.

  • PDF