• 제목/요약/키워드: Beam Radiation

검색결과 1,764건 처리시간 0.034초

Age diffusion model을 이용한 전자선량 분포에 대한 연구 (A Study on the Electron Beam Distribution based on Age-diffusion Model)

  • 김성현;서태석;나유진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.161-163
    • /
    • 1997
  • In this paper, a two-dimensional electron beam dose calculational algorithm implented for use in a two-dimensional radiation therapy planning system is described. The 2-D electron beam calculations have been in use clinically for a few decades. Our algorithm uses Age-diffusion model based int the Boltzman Transport Equation. Our implementation provides convenient user interface associated with electron beam therapy planning and displays radiation dose distribution according to different electron energy on patient images.

  • PDF

상호 간섭 영향을 고려한 평면 배열형 음향 트랜스듀서의 방사 출력 예측 (A Prediction of Radiation Power for the Planar Array Acoustic Transducer Considering Mutual Coupling Effects)

  • 이종길;서인창
    • 한국음향학회지
    • /
    • 제15권1호
    • /
    • pp.17-22
    • /
    • 1996
  • 소나 시스템에 주로 사용이 되는 평면 배열형 음향 트랜스듀서는 수중에서 음을 방사하여 빔(beam)을 형성하게 된다. 이러한 빔은 트랜스듀서 진동체에서 발생하는 음향 출력이 공간상에 분포되어 일어난다. 따라서 방사 출력의 산출은 트랜스듀서의 성능 및 효율을 예측하는데 필요하다. 본 논문에서는 무한 배플에 고정된 9개의 음향 진동체를 모델로 선정하였다. 개별 진동체에서의 음향 방사량은 자기방사 및 상호방사의 조합으로 표현이 되며 전기적 등가회로 기법을 이용하여 진동체 상호간의 음향 간섭 영향을 고려하여 평면 배열형 음향 트랜스듀서 진동체의 방사 출력 예측 기법을 제안 하였다.

  • PDF

Shielding Evaluation and Activation Analysis of Facilities by Neutron Generator for the Development of 20 Feet Container Inspection System

  • Jin-Woo Lee;Dae-Sung Choi;Gyo-Seong Jeong
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.443-449
    • /
    • 2023
  • KAERI(Korea Atomic Energy Research Institute) is conducting research and development of large-scale radiation generators and the latest radiation measuring instruments. In particular, research and development of security screening equipment using an electron beam accelerator and a neutron generator is in progress recently. Globally, 20 ft containers are used to transport imports and exports, and electron beam accelerators are radiation sources to measure the shape of the material inside the container during customs inspections in each country. KAERI is developing a device that can use an electron beam accelerator and a neutron generator sequentially to grasp the shape of various materials as well as the location of the internal target material. In this study, when using the neutron generator, the radiation dose and the degree of activation by neutron for the facility and surrounding environment, facility equipment were simulated using MCNP and FISPACT code. As a result, the shielding structures inside and outside the radiation control area were satisfactory to the reference level established conservatively based on the Korean Nuclear Act.

Modeling Phased Array Ultrasonic Testing of a Flat-Bottom Hole in a Single Medium

  • Park, Joon-Soo;Kim, Hak-Joon;Song, Sung-Jin;Seong, Un-Hak;Kang, Suk-Chull;Choi, Young-Hwan
    • 비파괴검사학회지
    • /
    • 제25권6호
    • /
    • pp.467-474
    • /
    • 2005
  • The expanded multi-Gaussian beam model has recently been developed that can calculate the radiation beam field from a single, rectangular transducer with great computational efficiency. In this study, this model is adopted to calculate the radiation beam field for a phased array transducer with various time delays to achieve steering and/or focusing. The calculation beam fields are compared to those obtained by well known Rayleigh-Sommerfeld integral that provides the exact solution in order to explore the validity of the expanded multi-Gaussian beam model And then, this study proposes a complete ultrasonic measurement model including the expanded beam model, far-field scattering model and system efficiency, Using the proposed model, phased array ultrasonic testing signals for a flat-bottomed hole with/without focusing were performed.

Improvement of Calculation Accuracy in the Electron Monte Carlo Algorithm with Optional Air Profile Measurements

  • Sung, Jiwon;Jin, Hyeongmin;Kim, Jeongho;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon;Chun, Minsoo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.163-171
    • /
    • 2020
  • Purpose: In this study, the accuracies of electron Monte Carlo (eMC) calculation algorithms were evaluated to determine whether electron beams were modeled by optional air profiles (APs) designed for each applicator size. Methods: Electron beams with the energies of 6, 9, 12, and 16 MeV for VitalBeam (Varian Medical System, Palo Alto, CA, USA) and 6, 9, 12, 16, and 20 MeV for Clinac iX (Varian Medical System) were used. Optional APs were measured at the source-to-detector distance of 95 cm with jaw openings appropriate for each machine, electron beam energy, and applicator size. The measured optional APs were postprocessed and converted into the w2CAD format. Then, the electron beams were modeled and calculated with and without optional APs. Measured profiles, percentage depth doses, penumbras with respect to each machine, and energy were compared to calculated dose distributions. Results: For VitalBeam, the profile differences between the measurement and calculation were reduced by 0.35%, 0.15%, 0.14%, and 0.38% at 6, 9, 12, and 16 MeV, respectively, when the beams were modeled with APs. For Clinac iX, the differences were decreased by 0.16%, -0.31%, 0.94%, 0.42%, and 0.74%, at 6, 9, 12, 16, and 20 MeV, respectively, with the insertion of APs. Of note, no significant improvements in penumbra and percentage depth dose were observed, although the beam models were configured with APs. Conclusions: The accuracy of the eMC calculation can be improved in profiles when electron beams are modeled with optional APs.

Oprimization Study for the CRC PIXE System Beam Transport Line

  • Jeong, Cheol-Ki;Lee, Goung-Jin
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.59-63
    • /
    • 2014
  • Proton Induced X-ray Emission (PIXE) is a MeV ion beam analysis method for use with particle accelerators. PIXE uses low-energy charged particles as an excitation mechanism to generate characteristic x-ray emission from each element in a target. In PIXE analysis, the beam current used is from a few nA to several tens of nA. Chosun University (Cyclotron Research Center) designed a $50{\mu}A$ beam line from the 13 MeV cyclotron for use with a PIXE analysis system, as well as performing beam transport line optimization research. In this study, the beam line operation conditions for the optimization process of beam transport and beam characteristics are shown.

전신 피부 전자선 조사(TSEB)시 두정부(Vertex)에서의 선량 변화 평가 (Evaluation of dose variation at the vertex during Total Skin Electron Beam)

  • Jeon Byeong-Chul;An Seung-Kwon;Lee Sang-Gyu;Kim Joo-Ho;Cho Kwang-Hwan;Cho Jung-Hee;Park Jae-Il
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.112-116
    • /
    • 2000
  • 목적 전신피부 전자선 치료시 두정부의 scalp는 항상 사방향으로 입사된다. 본 연구는 두정부에서의 선량균등성을 향상시키기 위한 목적으로 본원에서 자체 제작한 전자선 반사체(electron reflector)를 두정부의 scalp 위치에 놓아 반사되는 전자선을 이용하여 선량변화를 조사하고 전자선 반사체의 효용성을 평가하고자 한다. 대상 및 방법 두정부에서의 선량측정은 6MeV 전자선을 이용한 전리조(ion-chamber)와 열형광선량계(TLD)를 사용하였고, 산란되는 전자선의 영향을 평가하기 위해 자체 제작한 $40{\times}40cm^2$, 1 mm 두께의 전자선 반사체를 팬톰위에 위치시켜 선량을 측정하였다 결과 두정부에서의 표면선량은 전자선 반사체를 사용하지 않았을 때에 $37.8\%$로 나타났으며, 이에 반해 반사체를 사용하였을 때는 $62.2\%$의 선량증가를 나타내었다. 결론 일반적으로 시행되는 전신피부전자선조사는 두정부에서의 under-dose를 확인할 수 있었고, 본원에서 자체 제작한 전자선 반사체 사용시 두정부에서의 선량 균등성이 향상되어 추가적인 치료가 필요치 않을 것으로 생각된다.

  • PDF

Gradient based algorithm을 이용한 multiple slice IMRT optimization (IMRT optimization on multiple slice using gradient based algorithm)

  • 이병용;조병철;이석;정원균;안승도;최은경;김종훈;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.201-206
    • /
    • 1998
  • 세기변조방사선치료 (Intensity Modulation Radiation Therapy; IMRT) 의 치료계획 목적으로 사용하기 위한 선량최적화 방법을 Gradient based algorithm을 이용하여 개발하였다. 환자의 치료 관심 부위를 포함하는 약 10-30 CT 단면에 대하여 각 단면 별로 선량최적화를 실시하였고, 장기별로 최대 허용선량을 지정하였으며, 표적의 선량은 100$\pm$5 %로 제한하였다. beamlet의 크기는 8$\times$8 $cm^2$으로 제한하였고, beam size가 크지 않으므로 beam diverge는 고려하지 않았다. beamlet 하나가 만드는 선량분포를 미리 계산한 후, 선량중첩방식으로 전체 선량분포를 계산하였다. 고정된 동일평면에 대하여 5방향에서 입사하는 빔에 대한 최적화를 실시하였으며, 그 효용성을 비교하기 위해, 1, 3, 5, 7, 9 방향에 입사하는 빔과 최적화지수를 구하였다. 선량최적화에 소요되는 시간은 대체로 slice 수에 비례하였으며, 계산시간과 최적화지수를 비교할 때 빔의 개수가 3-7개 일 때 가장 적합하였다. 다중단면에 대한 선량최적화를 beam divergence를 고려하지 않을 때, 단일 단면에 대한 선량최적화를 반복 시행함으로써 얻을 수 있었다. 선량최적화의 결과가 선량중심의 위치에 따라 민감하게 변하는 경우가 발생하였으며, 이를 개선하기 위해서는 선량중심의 최적화가 개발될 필요성이 있었다.

  • PDF

횡방향 자기장이 고에너지 전자선의 선량분포에 미치는 영향 (Effect of Transverse Magnetic Field on Dose Distribution of High Energy Electron Beam)

  • 오영기;김기환;신교철;김진기;김정기;정동혁;조문준;김준상;윤선민;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권4호
    • /
    • pp.209-213
    • /
    • 2007
  • 20 MeV 전자선의 팬텀 내에서의 선량분포에 대한 횡방향 자기장 효과를 조사하기 위하여 전자석을 제작하여 자기장 인가 여부에 따른 등선량곡선 및 깊이선량율을 X-OMAT 필름으로 측정하였다. 1.5 Tesla의 자기장중심을 팬텀 표면으로부터 7.5 cm 깊이에 위치시킨 경우 팬텀 표면으로부터 4.5 cm 깊이에서 약 30%의 선량증가를 보이는 등 이론적으로 알려진 결과들과 잘 부합하고 있음을 확인하였다.

  • PDF

전자선 조사된 폴리프로필렌 부직포의 그라프트에 있어 보관조건이 미치는 영향 (Effect of Storage Conditions on Graft of Polypropylene Non-woven Fabric Induced by Electron Beam)

  • 이진영;전준표;강필현
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.57-62
    • /
    • 2015
  • In this study, we fabricated effect of storage conditions on graft of polypropylene (PP) non-woven fabric induced by electron beam. The electron beam irradiations on PP non-woven fabric were carried out over a range of irradiation doses from 25 to 100 kGy to make free radicals on fabric surface. The radical measurement was established by electron spin resonance (ESR) for confirming the changes of the alkyl radical and peroxy radical according to effect of storage time, storage temperature and atmosphere. It was observed that the free radicals were increased with irradiation dose and decreased with storage time due to the continuous oxidation. However, the radical extinction was significantly delayed due to reduced mobility of radicals at extremely low temperature. The degree of graft based on the analysis of ESR was investigated. The conditions of graft reaction were set at a temperature: $60^{\circ}C$, reaction time: 6 hours and styrene monomer concentration: 20 wt%.