• Title/Summary/Keyword: Beam Quality

Search Result 1,051, Processing Time 0.023 seconds

Trend of Laser Beam Welding Technology (고밀도 열원방식 레이저빔 용접의 연구동향)

  • Kim, H.T.;Kil, S.C.
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.481-484
    • /
    • 2011
  • The increasing interest in the laser beam welding is placing stringent demands on the manufacturing techniques and performance requirements, and the manufacture employs the high quality and efficiency laser beam welding technology. This paper covers recent research trends of the laser beam welding technology including the laser beam surfacing and laser beam cladding technology.

  • PDF

Development of non-destructive testing method to evaluate the bond quality of reinforced concrete beam

  • Saleem, Muhammad;Almakhayitah, Abdulmalik Mohammed
    • Structural Engineering and Mechanics
    • /
    • v.74 no.3
    • /
    • pp.313-323
    • /
    • 2020
  • Non-destructive tests are commonly used in construction industry to access the quality and strength of concrete. However, till date there is no non-destructive testing method that can be adopted to evaluate the bond condition of reinforced concrete beams. In this regard, the presented research work details the use of ultra-sonic pulse velocity test method to evaluate the bond condition of reinforced concrete beam. A detailed experimental research was conducted by testing four identical reinforced concrete beam samples. The samples were loaded in equal increments till failure and ultra-sonic pulse velocity readings were recorded along the length of the beam element. It was observed from experimentation that as the cracks developed in the sample, the ultra-sonic wave velocity reduced for the same path length. This reduction in wave velocity was used to identify the initiation, development and propagation of internal micro-cracks along the length of reinforcement. Using the developed experimental methodology, researchers were able to identify weak spots in bond along the length of the specimen. The proposed method can be adopted by engineers to access the quality of bond for steel reinforcement in beam members. This allows engineers to carryout localized repairs thereby resulting in reduction of time, cost and labor needed for strengthening. Furthermore, the methodology to apply the proposed technique in real-world along with various challenges associated with its application have also been highlighted.

The Development of High Speed Wavefront Sensor for Diagnosis of Beam Quality of He-Ne Laser (He-Ne 레이저 빔 품질 진단용 고속파면센서 개발)

  • Lee, Young-Cheol;Lee, Jae-Il;Kang, Eung-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.160-167
    • /
    • 2007
  • In this paper, we presented the development results of high speed wavefront sensor which is used in diagnosing the beam quality of He-Ne laser for adaptive optics system. The beam quality information of laser in AO system is necessarily required for diagnosing the optical components or correcting the distorted wavefront afterward. According to system requirements, normally, it is requested that there are high precision of measurement and real time processing speed. The developed wavefront sensor in this paper achieved maximum 30Hz of measurement rate and ${\lambda}/20(\;{@}\;{\lambda}=0.6328{\mu}m)$ of measurement precision in RMS. We also applied the developed into an experimental adaptive system and verified the performance of it by correcting the aberrated wavefront with a rate of 30Hz and $\lambda$/20 precision using the combination of the developed and PID control algorithm.

Measurement of X-ray Quality in Mammography Unit (유방촬영용 X선장치의 선질 특성)

  • Lee, In-Ja;Kim, Jung-Min;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.5-10
    • /
    • 1998
  • In the mammography, X-ray beam quality is one of the most important factors. Using X-ray mammography unit model GE/CGR Senography 600T Senix H.F, Authors studied four subjects. 1. The aluminum attenuation rate in 30 kVp when used with or without compression plate. 2. HVLs at 5 different area of the X-ray field of $26{\sim}32kVp$. 3. HVLs to know the influence of corrected measurement or parallel measurement. 4. Film density with microdensitometer along and cross to the long axis of X-ray tube, in terms of the Heel effect in the X-ray field. The following results were obtained. 1. Beam quality of anode area was harder than cathode area. 2. The dose reduction rate of compression plate was approximately $65.5%{\sim}88.1%$ and the beam quality with compression plate was hardened up to 4kVp accordingly. 3. If the X-ray beam enters the attenuation plate obliquely, HVL was $2.6{\sim}2.9%$ harder than perpendicular to it. 4. Because of heel effect, the film density of cathode area is higher than anode area to film density of 0.5.

  • PDF

Study of photon beam quality tool at magnetic field change in bending magnet (편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰)

  • Kim, Jeong-Ho;Yoo, Se-Jong;Park, Myeong-Cheol;Bae, Seok-Hwan;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

Comparison of EM 120 Multibeam Echo Sounding Data with SeaBeam 2000 Data Acquired at KODOS(Korea Deep Ocean Study) Area (한국 심해연구지역에서 획득된 EM 120과 SeaBeam 2000의 자료 비교)

  • Lee, Gun-Chang;Kim, Hyun-Sub;Ko, Young-Tak;Jung, Mee-Sook;Ham, Dong-Jin;Kim, Jong-Uk
    • Ocean and Polar Research
    • /
    • v.28 no.4
    • /
    • pp.467-473
    • /
    • 2006
  • The EM 120, a newly installed multibeam echo sounder on RM Onnuri, has several advantages over the previously installed SeaBeam 2000 in performance and thus data quality. The EM 120 system provides a bottom topographic map with high resolution by (1) increasing the number of beams, (2) increasing the across track swath range, (3) measuring the more accurate sound velocity within the water column, and (4) improving stabilization for pitching, rolling, and yawing of the ship. This study compares EM 120 and SeaBeam 2000 echo sounders in terms of the data quality from the same survey area in the Clarion-Clipperton Zone, NE Pacific. Our result shows that the EM 120 provides more precise topographic data than the SeaBeam 2000. Although overall trends of data, such as topographic direction and relief, are similar for both echo sounders, the water depths measured by the EM 120 are shallower than that of SeaBeam 2000 by 80 to 90 meters.

Evaluation of Detection Performance of TlBr Materials for the Development of Electron Beam Quality Assurance Dosimeters (전자선 Quality Assurance 선량계 개발을 위한 TlBr 물질의 검출성능 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.513-518
    • /
    • 2022
  • Electron beam quality assurance (QA) should be done regularly for accurate radiation therapy. However, QA tools used in clinical practice are designed mainly for X-rays. So, a dosimeter for electron beam QA is required. Therefore, in this study, the electron beam detection performance was measured by using a thorium bromide material as an electron beam sensor. In addition, it was evaluated whether it could be applied with an electron beam QA dosimeter. Reproducibility, linearity, and dose rate dependence were evaluated at 6 MeV and 9 MeV energies. As a result of reproducibility, it showed a maximum output change of 0.92% at 6 MeV and 1.15% at 9 MeV. The linearity result evaluation and determination coefficient were presented as 0.9998. As a result of dose rate dependence evaluation, relative standard deviation 0.51% at 6 MeV and relative standard deviation 1.07% at 9 MeV were presented. The manufactured TlBr sensor shows the ability to detect radiation that meets the criteria for evaluation of reproducibility, linearity, and dose rate dependence. These results mean that the TlBr dosimeter is applicable as an electron beam QA dosimeter.

Comparison of Beam Quality Index of High Photon Beam (고에너지 광자선의 선질 지표에 관한 비교)

  • 신동오;지영훈;박성용;박현주;김회남;홍성언;권수일;서태석;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.185-192
    • /
    • 1998
  • It is necessarily to evaluate the energy of X-ray emitted from linear accelerator in order to determine the accurate absorbed dose. The method of direct measurement for x-ray energy is very difficult and impractical. Therefore the method of using beam quality index is generally used. Several dosimetry protocols recommend the use of quality indices such as depth of dose maximum at radiation central axis, dose gradient, and dose level. The linear accelerator manufactures follow the recommendation as dosimetry protocols. The study was performed for us to select the most suitable parameter among the Quality indices as described above. For photon beams of 4, 6, 10, 15, and 21 MV nominal energies produced by four kinds of accelerators(Mitsubishi, Scanditronix, Siemens, Varian) in eleven institutions, We evaluated the x-ray energies obtained by the Quality indices as recommended by several dosimetry protocols and manufactures. Results showed that there were energy spreads according to the same accelerators and Quality indices even though nominal energies were same. It appeared that the percent depth dose at 10 cm (D$_{10}$(%)) gave the smallest deviation and spread of energies. As energies increased, the energy deviation increased for all the quality indices. It is desirable for the use of unified quality index to compare the evaluation of beam quality at different institutions.

  • PDF

Non Dosimetry Measurements Use for Patients Safety : NDD-M (환자 안전을 위한 비 계측 선량측정의 활용 : NDD-M)

  • Gil, Jong-Won;Seon, Jong-Ryoul;Song, Wol-Su
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.141-145
    • /
    • 2016
  • This study was to improve to utilization of non dosimetry measurements for X-ray radiography. Experiments was passed off varying the X-ray tube voltage and the thickness of the aluminum filter by actual dose. Calculated results was set to the first beam quality factors, calculated first correction coefficient by the Microsoft Excel program was set as the second beam quality factors. To make the non dosimetry measurements simply, the Excel program apply to the new beam quality factors, the error was compared to the previous studies, and the results verify the calculated value of smaller errors.

Fabrication Technology for Improving Pattern Quality in Two-Dimensional Photonic Crystal Structure (2차원 광결정 제작에 패턴 특성을 향상시키기 위한 공정 기술)

  • 김해성;신동훈;김순구;이진구;이범석;김혜원;이재은;한영수;최영호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.515-521
    • /
    • 2003
  • There are now many theoretical investigations and real manufactures for numerous applications of photonic crystals (PCs) associated with photonic band gap and photonic integrated circuits. However, there are some difficulties to design and fabricate the desired pattern quality. It is not easy to satisfy accurate critical dimension (CD) for patterns with arbitrary shapes and pitch sizes aligned in various directions. In this work, we report the optimum conditions to better fabricate and design, and greatly improve pattern quality in delineating two-dimensional (2D) PCs in the nanometer range using single- step e-beam lithography system with conventional exposure mode.