• Title/Summary/Keyword: Beam Factor

Search Result 1,017, Processing Time 0.036 seconds

Analysis of Electrical Properties of Ti/Pt/Au Schottky Contacts on (n)GaAs Formed by Electron Beam Deposition and RF Sputtering

  • Sehgal, B-K;Balakrishnan, V-R;R Gulati;Tewari, S-P
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • This paper describes a study on the abnormal behavior of the electrical characteristics of the (n)GaAs/Ti/Pt/Au Schottky contacts prepared by the two techniques of electron beam deposition and rf sputtering and after an annealing treatment. The samples were characterized by I-V and C-V measurements carried out over the temperature range of 150 - 350 K both in the as prepared state and after a 300 C, 30 min. anneal step. The variation of ideality factor with forward bias, the variation of ideality factor and barrier height with temperature and the difference between the capacitance barrier and current barrier show the presence of a thin interfacial oxide layer along with barrier height inhomogenieties at the metal/semiconductor interface. This barrier height inhomogeneity model also explains the lower barrier height for the sputtered samples to be due to the presence of low barrier height patches produced because of high plasma energy. After the annealing step the contacts prepared by electron beam have the highest typical current barrier height of 0.85 eV and capacitance barrier height of 0.86 eV whereas those prepared by sputtering (at the highest power studied) have the lowest typical current barrier height of 0.67 eV and capacitance barrier height of 0.78 eV.

Development of Design Formulas for Pipe Loops Used in Ships Considering the Structural Characteristics of Curved Portions (곡선부의 구조 특성을 고려한 선박용 파이프 루프 설계식 개발)

  • Park, Chi-Mo;Bae, Byoung-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.87-93
    • /
    • 2012
  • Many longitudinally-arranged pipes in ships are equipped with loops as a measure to reduce stresses caused by displacement loads conveyed from the hull girder bending and/or thermal loads of carried fluid of non-ambient temperature. But as the loops have some negative effects such as causing extra manufacturing cost and occupying extra space, the number and the dimensions of the loops need to be minimized. In the meanwhile, a design formula for pipe loops has been developed by modeling them as a spring element of which stresses and axial stiffness are calculated based on the beam theory. But as the beam theory turns out to be inappropriate to deal with the complex structural behavior in the curved corner portion of the loop, this paper aims at improving the previously developed design formula by adopting correction factors which can allow for the gap between the results of beam theory and a more accurate analysis. This paper adopts a finite element analysis with two-dimensional shell elements with some validation work for it. The paper ends with a sample application of the proposed formulas showing their accuracy and efficiency.

Simple Method of Analysis for Reinforced Concrete Slab Bridges (간단한 방법에 의한 철근콘크리트 슬래브 교량의 해석)

  • Han, Bong-Koo;Kim, Duk-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.81-89
    • /
    • 2003
  • The simple supported reinforced concrete slab bridges are analyzed by the specially orthotropic laminates theory. This method, however, may be too difficult for some practising engineers. In this paper, the result of analysis for such plate by means of the beam theory with unit width is reported. By using the "correction factor", the accurate solution for the plate can be obtained by the beam theory. The result of this paper can be used for reinforced concrete slab bridges analysis by the engineers with undergraduate study in near future.

The study and design of a deuteron drift tube linear accelerator for middle energy neutron source

  • Tianhao Wei;Yuanrong Lu;Zhi Wang;Meiyun Han;Ying Xia
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3933-3941
    • /
    • 2024
  • The paper concerns a room-temperature cross-bar H-mode (CH) drift tube linac (DTL) with KONUS (Kombinierte Null Grad Struktur) [1,2] beam dynamics. To make the acceleration in DTL cell more efficient, we studied the correlation between transit time factor (TTF) and structural coefficients, first. Furthermore, we developed a new code with Python to demonstrate the longitudinal dynamics more clearly. The code computationally generates clusters, bunch centers, and emittance growth in a single figure. Thus, the stabilization region and cluster evolution at various negative phases can be studied. Based on the above studies, we designed a 162.5 MHz CH-DTL to accelerate 10 mA D+ from 2.11 MeV to 3.25 MeV in continuous-wave (CW) mode. The proposed CH-DTL is a part of the Middle Energy Neutron Source (MENS). The dynamics and RF design were iterated to make the gap voltage error lower than 1 %. The initial beam is assumed to come from a Radio Frequency Quadrupole accelerator (RFQ). The geometries of the CH-DTL are optimized by using CST. Multiparticle tracking from LEBT to RFQ is performed with TraceWin and the transmission efficiency in the CH-DTL is 100 %.

Study on the Validation of the Gated Cone-Beam Computed Tomography on Radiation Therapeutic Linear Accelerator (방사선치료용 선형가속기를 이용한 Gated Cone-Beam CT의 유용성 연구)

  • Seo, Jeong-Min;Kim, Chan-Hyeong;Park, Byoung-Suk;Park, Cheol-Soo;Jang, Hyon-Chol;Kim, Joung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6932-6939
    • /
    • 2015
  • The respiration is one of important factor in the radiation therapy. The existing commercial method of cone-beam computed tomography on LINAC does not consider respiratory motion of patient hence the images are both distorted and inaccurate. In this study, the cone-beam computed tomography images have been reconstructed from back projection radiography of specific phase on breathing cycle which concerned about respiratory movement in radiation therapy. This study investigated how different between cone-beam CT images with and without gating respiratory movement, and this paper provides that guide and implementation of gated cone-beam CT on radiation therapeutic equipment.

Flexural behaviour of fully concrete encased steel castellated section with different configuration of openings

  • G. Velrajkumar;M.P. Muthuraj
    • Advances in concrete construction
    • /
    • v.17 no.5
    • /
    • pp.273-284
    • /
    • 2024
  • The steel-concrete composite system has been playing a vital role in the construction sector for the past two decades. By using steel and concrete together, we achieve strong load resistance with minimal deflection and bending stress. The study focuses on the numerical and analytical behaviour of concrete encased steel castellated beams and compared them with previous experiments. The study used five composite beams, including one control reinforced concrete beam (CC), one fully concrete encased steel beam (FCES), and three fully concrete encased castellated beams. The major variable is the opening configuration of the castellated beam, such as openings along the longitudinal axis, above the longitudinal axis, and below the longitudinal axis. The 150 mm × 250 mm cross section and 2000 mm in length of beams were used. Using the finite element software ANSYS, we conduct nonlinear finite element analysis for the entire beam and compare it with test data. The numerical load carrying capacity of concrete encased steel castellated beam with a hexagonal opening above the longitudinal axis (FCESCB H2) is 160 kN is closer to the experimental observation. Von Mises strain of FCESB is 0.004232, which is lower than CB and composite castellated beam. The ductility factor and energy absorption capacity of FCESB are 5.090 and 1688.47 kNm. It was observed that the configuration of the opening will influence the strength of the composite beam. Plastic moment methods were employed to estimate the ultimate load carrying capacity of the beam. In the analytical study the beams were assumed as perfectly plastic. The ultimate analytical load carrying capacity of FCESCB H2 is 21.87% higher than FCESB. It found that performing FCESCB H2 is superior to the entire specimen.

Characteristics of the Eigenvalue Sensitivities to the Change of Element Correction Factors for Beams

  • Lee, Gun-Myung;Park, Young-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.955-960
    • /
    • 2004
  • Some characteristics of the eigenvalue sensitivities have been found for beams in the paper. For cantilever beams and simply supported beams, the sensitivities of the eigenvalues to the stiffness correction factor of one element are equal and opposite to the sensitivities to the mass correction factor of the symmetrically positioned element. For beams with other boundary conditions, however, the relationship does not hold. The relationship has been proven analytically for simply supported beams.

Development of Impact Factor Response Spectrum based on Frequency Response of Both Ends-Fixed Beam for Application to Continuous Bridges (연속교 적용을 위한 양단고정지지 보의 진동수 기반 충격계수 응답스펙트럼 개발)

  • Roh, Hwasung;Lee, Huseok;Park, Kyung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.301-306
    • /
    • 2016
  • In bridge performance assessments, a new load carrying capacity evaluation model of simple bridges was proposed, which is based on the developed simple support impact factor spectrum. In this paper, a conservative assumption that the inner span with the both ends fixed boundary condition is ideal for applying the impact factor response spectrum for continuous bridges. The impact factor response spectrum has been proposed based on this assumption. The response spectrum by comparing the numerical analysis result and actual measurement data verified the applicability. The analysis was loading the moving load of DB-24 in a six-span continuous bridge, which was the same as the actual measurement data, the dynamic response was measured in the fourth span. The frequency of the bridge was obtained by FFT on the acceleration response and the span-frequency of sample bridge was calculated by the frequency. The impact factor of the sample bridge was determined by applying the span-frequency of the bridge to the proposed response spectrum; it was similar to the result of comparing the actual measured impact factor. Therefore, the method using the impact factor response spectrum based on the frequency response of both ends-fixed beam was found to be applicable to an actual continuous bridge.

The Study of the Measurement Point for Wedge Factor (쐐기 인자 결정 깊이에 관한 연구)

  • 김현자;이병용;김계준;배훈식;최은경;장혜숙;안기정
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.13-22
    • /
    • 1992
  • Traditionally. the wedge factor of universal wedge is regarded as constant for small depth. Recently. some investigators have reported the beam hardening effect from wedged beam even in small depth. suggesting that the wedge factors are depth dependent values. Here authors performed the study to determine the proper depth of measurement for wedge factor. In this study. we have measured the wedge factors (nominal wedge angles 15, 30, 45, and 60) not only for depth maximum. but also for each depth, for several energies (4MV, 6MV, 10MV, and 15MV) of various machines (Varian, Siemens, Mitsubishi). And we have analysed the treatment depth of 614 patients who had been treated with wedged field at our hospitals to determine of the proper depth of the measurement point for wedge factor. More than 60% of the patients are treated at the depth of 8cm$\pm$2.5cm with the wedged field for various machines. energies, and wedge angles. The results of the wedge factor measurements show that the systemic error of average 2% (maximum 4%) might be inherently originated for the patients who had been treated with wedged field if we adapt the depth maximum as the wedge factor determination depth due to beam hardening effect. But we could achieve average error less than 0.5% (maximum within 1.7%) if we use 8cm for wedge factor measurement point We conclude that the measurement depth point for wedge factor should be 8cm in order to deliver more accurate dose to target for Korean patients. instead of depth maximum.

  • PDF

A Consideration on Deformation Characteristics of Soil Nailed Retaining-Walls on Field Measurements (현장계측에 의한 쏘일네일링 보강벽체의 변형특성에 관한 고찰)

  • Yoon, Bae-Sic;Lee, Jong-Moon;Kang, In-Kyu;Kwon, Young-Ho;Kim, Hong-Taek
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.534-537
    • /
    • 2007
  • The soil nailing was generally using method in practical business, in application of the soil nailing, the analysis was primarily used to Beam-Colum Method, Finite Element Method and Limit Equilibrium Method. Beam-Colum Method and Finite Element Method were able to examine transformation but widely using Limit Equilibrium Method wasn't able to examine transformation and displacement Therefore, this study was focused on presenting stability in comparison with former study-results about horizontal displacement of the soil nailing retaining-walls satisfing a criterion safety factor of Limit Equilibrium. There were performing comparison field measurements and former study-results in first step.

  • PDF