• Title/Summary/Keyword: Beam

Search Result 19,814, Processing Time 0.04 seconds

Investigation of two parallel lengthwise cracks in an inhomogeneous beam of varying thickness

  • Rizov, Victor I.
    • Coupled systems mechanics
    • /
    • v.9 no.4
    • /
    • pp.381-396
    • /
    • 2020
  • Analytical investigation of the fracture of inhomogeneous beam with two parallel lengthwise cracks is performed. The thickness of the beam varies continuously along the beam length. The beam is loaded in three-point bending. Two beam configurations with different lengths of the cracks are analyzed. The two cracks are located arbitrary along the thickness of the beam. Solutions to the strain energy release rate are derived assuming that the material has non-linear elastic mechanical behavior. Besides, the beam exhibits continuous material inhomogeneity along its thickness. The balance of the energy is analyzed in order to derive the strain energy release rate. Verifications of the solutions are carried-out by considering the complementary strain energy stored in the beam configurations. The influence of the continuous variation of the thickness along the beam length on the lengthwise fracture behavior is investigated. The dependence of the lengthwise fracture on the lengths of the two parallel cracks is also studied.

Optimization of Prestressed Concrete Beam Section (프리스트레스트 콘크리트 보 단면의 최적설계)

  • 조선규;최외호
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.91-101
    • /
    • 2000
  • As the computer related technology evolves a study for a practical use of real structure as well as its hteory for optimum design has been greatly advanced. But the study on optimum design of pre-stressed concrete beam(PSC-beam) bridge for the construction of national roads and highways in Korea is not sufficient. Since a standard section for the PSC-beam is proposed, it is practically used in designing the PSC-beam. It is noticed that the section using the current standard PSC-beam design to be an over-designed with its surplus safety factor. Therefore, it is necessary to consider economical PSC-beam section which automatically satisfies all requirement of design specifications. Thus, in this study, the optimum design methods of PSC-beam are carried out using the gradient-based search method and global search method. As a result of the optimum design method, it was confirmed that the design of PSC-beam has a serious properties to non-linearity and discontinuity. And the section that in economical and efficinet design methods than the current standard design method is proposed.

Efficient Beam-Training Technique for Millimeter-Wave Cellular Communications

  • Ku, Bon Woo;Han, Dae Gen;Cho, Yong Soo
    • ETRI Journal
    • /
    • v.38 no.1
    • /
    • pp.81-89
    • /
    • 2016
  • In this paper, a beam ID preamble (BIDP) technique, where a beam ID is transmitted in the physical layer, is proposed for efficient beam training in millimeter-wave cellular communication systems. To facilitate beam ID detection in a multicell environment with multiple beams, a BIDP is designed such that a beam ID is mapped onto a Zadoff-Chu sequence in association with its cell ID. By analyzing the correlation property of the BIDP, it is shown that multiple beams can be transmitted simultaneously with the proposed technique with minimal interbeam interference in a multicell environment, where beams have different time delays due to propagation delay or multipath channel delay. Through simulation with a spatial channel model, it is shown that the best beam pairs can be found with a significantly reduced processing time of beam training in the proposed technique.

Environmental Friendly Construction Process of Composite Beam and its Application (친환경 층고 절감형 합성보의 시공 Process 및 시공사례)

  • Hong, Won-Kee;Park, Seon-Chee;Lee, Kyoung-Hun;Kim, Jeom-Han;Lee, Ho-Chan;Hwang, Yun-Ha
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.107-112
    • /
    • 2007
  • Recently hybrid beam system is widely used because it has many structural advantages such as short construction period and low story height etc. Generally steel wide flange beam exposure type and embedded type hybrid beams are constructed. Even though exposure hybrid beam is easily constructed, the fire proofing protection process is necessary because steel wide flange beam cannot resist to fire itself. Story height reduction type hybrid beam, which is introduced hybrid beam in this paper, does not need fire proofing protection process because it is constructed as a fully embedded type hybrid beam. Developed construction process and actual construction cases of story height reduction type hybrid beam were introduced in this study.

Portable Infrared Laser Transmitter Based on a Beam Shaper Enabling a Highly Uniform Detectable Beam Width

  • Yue, Wenjing;Kim, Haeng-Jung;Lee, Sang-Shin
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.486-490
    • /
    • 2013
  • A portable infrared laser transmitter delivering a highly uniform detectable beam was demonstrated. It incorporates a flexible beam shaper, comprising a perforated diffuser sheet in conjunction with a pinhole. The beam shaper plays the prominent role of flexibly tailoring the incoming light via both scattering and diffraction, in order to equalize the effective beam width over a long distance. The intensity profile of a generated beam was practically observed, demonstrating that a substantially uniform beam of 70-cm width was achieved for a given threshold detection level, with an average deviation of 6% over a range of 600 m.

Behaviour of RC beam-column joint with varying location of construction joints in the column

  • Vanlalruata, Jonathan;Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.29-38
    • /
    • 2021
  • According to ACI 224.3R-95 (ACI, 2013), construction joints (cold joint) in the column are to be provided at the top of floor slab for column continuing to the next floor and underside of floor slab and beam. A recent study reveals that providing cold joint of the mentioned location significantly reduced the seismic performance of the frame structures. Since, the construction joints in multi-story frame structures normally provided at the top of the floor slabs and at soffit of the beam in the column. This study investigated the effect of construction joint at various location in the column of beam-column joint such as at the top of floor slab, soffit level of the beam, half the depth of beam below the soffit of the beam and at a full depth of the beam below the soffit of the beam. The study revealed that there is an improvement in seismic capacity of the specimens as the location of cold joint is placed away from the soffit of the beam for lower story column.

A study on the Framed Structure with Triple Beam In the Korean Wooden Architecture (한국 목조건축의 삼중량(三重樑) 가구(架構)에 관한 연구)

  • Yang, Jae-Young
    • Journal of architectural history
    • /
    • v.17 no.3
    • /
    • pp.61-80
    • /
    • 2008
  • The purpose of this study is to discover the characteristics and the change of the framed structure with triple beam. 61 existing buildings with the triple beam structure were selected and analyzed extensively. The result of this study could be described in detail like below. The triple beam structure is used in the highly graded and symbolized building like the Buddhist sanctum and the Confucian sanctum. And the triple beam structure was chiefly used in $1600{\sim}1800's$. Generally, 1 Koju-type with Toikan(退間) is applied to the triple beam structure. Despite of the sameness of framed structure, there is a tendency that the rear Toikan(後退間) is used in the Buddhist sanctum and the front Toikan(前退間) is used in the Confucian sanctum. This different application of the Toikan(退間) resulted from the different spatial characteristics which reflect function and grade of the building. The application of Sangjungdori(上中道里, upper purlin) and two Danyeon(短椽, short rafter) is a necessary consequence, because Jungbo(중보, middle beam) is located between Daebo(대보, beam) and Jongbo(종보, small and high located beam) as an additional member of frame. And these are essential characteristics of the framed structure with triple beam. The triple beam structure is formed in a transitional period, as the result from eliminating the inner high-column from the 2 Koju and double beam structure. Though the Daebo is longer, the structure is more stable. But the rate of application of the triple beam structure is low, because it does not exceed the double beam structure in merits. Some of buildings with the triple beam structure has the asymmetrical characteristic in design, which is appeared in the latter period of Joseon Dynasty.

  • PDF

An Experimental Study on Internal Force By Using Fiber Rope Concrete Beam (섬유로프 인장 배치 시 콘크리트 보의 내력에 관한 실험적 연구)

  • Choi, Jae-Nam;Jin, Sung-Il;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.78-83
    • /
    • 2012
  • This is a study to confirm how to improve and substitute the existing re-bar with other material such as a fiber rope, especially super fiber rope having much more strong tensile strength. 6(b) different fiber rope reinforced beam with a section of $20{\times}30cm$ have been made and tasted as variables designed in the study. The larger diameter of fiber rope, the more capacity of the beam, even though fiber reinforced beam are increased with ten(10)percent, each. Lower capacity of fiber-reinforced beam than normal RC beam has been analyzed theoretically and empirically, based on a lot of experiences of the same size beam test. Fiber rope-reinforced concrete beam does not have sufficient capacity than RC beam due to insufficient bonding capacity of fiber rope in concrete. It leads to decrease beam bearing capacity and crack around lower center of the beam. Therefore, bonding reinforcement of fiber rope beam such as pinning a triangles steel pin in each knot of fiber rope contributes to improving bearing capacity of fiber rope reinforcing beam.

Dynamics of an elastic beam and a jumping oscillator moving in the longitudinal direction of the beam

  • Baeza, Luis;Ouyang, Huajiang
    • Structural Engineering and Mechanics
    • /
    • v.30 no.3
    • /
    • pp.369-382
    • /
    • 2008
  • An oscillator of two lumped masses linked through a vertical spring moves forward in the horizontal direction, initially at a certain height, over a horizontal Euler beam and descends on it due to its own weight. Vibration of the beam and the oscillator is excited at the onset of the ensuing impact. The impact produced by the descending oscillator is assumed to be either perfectly elastic or perfectly plastic. If the impact is perfectly elastic, the oscillator bounces off and hits the beam a number of times as it moves forward in the longitudinal direction of the beam, exchanging its dynamics with that of the beam. If the impact is perfectly plastic, the oscillator (initially) sticks to the beam after its first impact and then may separate and reattach to the beam as it moves along the beam. Further events of separation and reattachment may follow. This interesting and seemingly simple dynamic problem actually displays rather complicated dynamic behaviour and has never been studied in the past. It is found through simulated numerical examples that multiple events of separation and impact can take place for both perfectly elastic impact and perfectly plastic impact (though more of these in the case of perfectly elastic impact) and the dynamic response of the oscillator and the beam looks noisy when there is an event of impact because impact excites higher-frequency components. For the perfectly plastic impact, the oscillator can experience multiple events of consecutive separation from the beam and subsequent reattachment to it.

Influence of constraint MgO deposition onto phosphors on luminance properties in AC Plasma Display Panels

  • Jeoung, Jin-Man;OH, P.Y.;Moon, M.W.;Lee, J.H.;Jeong, J.E.;Lee, H.J.;Han, Y.K.;Lee, S.B.;Jeong, S.H.;Yoo, C.K.;Yoo, N.R.;Choi, E.H.;Ko, B.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1215-1217
    • /
    • 2005
  • One of the important problems in recent AC-PDP technology is the image sticking. In this research, we have investigated the PDP cell with constraint deposition MgO on phosphor, the electrical and optical properties in the PDP cell were examined. Also, we have investigated the correlation with image sticking and degraded MgO protective layer, phosphor in AC-PDP. As a result, we measured the secondary electron emission coefficient ${\gamma}$, discharge characteristics and Brightness for the constraint degraded phosphor are compared with those of nondegraded phosphor.

  • PDF