• 제목/요약/키워드: Battery industry

검색결과 227건 처리시간 0.02초

전기자동차 파우치형 배터리 열관리 시스템의 냉각성능 향상에 대한 연구 (A Study on the Cooling Performance Improvement of Pouch Battery Thermal Management System for Electric Vehicles)

  • 신정훈;이준경
    • 한국산업융합학회 논문집
    • /
    • 제25권5호
    • /
    • pp.715-724
    • /
    • 2022
  • In many electric vehicles, large-capacity pouch-type lithium-ion battery packs are mainly used to increase the mileage on a single charge. The lithium ion battery should be operated within the temperature range of 25℃ to 40℃ because the battery performance can be rapidly deteriorated due to an increase in internal temperature. Battery thermal management system (BTMS) can give the suitable temperature conditions to battery by water cooling method. In this research, the heat transfer characteristics (the battery temperature distributions and the water flow characteristics) were analyzed by CFD method to investigate the thermal performance of the cooling plate with 4-pass water flow structure. Moreover, the effect of the presence of fins between the battery cell was identified. The fins made smooth temperature distributions between the battery cells due to the heat spreading and lower the average battery cells temperature.

한국 이차전지기업의 글로벌 생산공간 재구성 연구 (A Study on the Restructuring Global Production Space of Korean Rechargeable Battery Companies)

  • 최자영
    • 한국경제지리학회지
    • /
    • 제25권4호
    • /
    • pp.499-513
    • /
    • 2022
  • 본 연구는 최근 급성장하고 있는 이차전지산업을 대상으로 한다. 이차전지산업은 전기차 산업과 밀접한 관련이 있다. 그러나 그 외에도 다양한 요인들이 영향을 미치고 있다. 현재 이차전지 기업들은 기존의 입지 외에도 다양한 요인들에 의해 생산공간을 구축하는 패턴을 보인다. 이러한 생산공간의 재구성 원인을 도출하기 위해 지역 및 국가 단위의 스케일에서 영향을 미친 요인들을 집중적으로 분석했다. 그 결과 이차전지 관련 기업들은 완성차 기업과의 협력 관계, 정부의 정책적 조절행위, 주요 소재 공급의 안정성 등에 따라 입지요인이 결정되었고, 배터리 셀 기업, 소재기업, 혹은 연계를 통한 공간전략을 구사하여 글로벌 생산공간의 입지를 결정하고 있었다.

SOC 및 SOH 추정을 위한 파라미터 추정기법에 관한 연구 (A Study on the Parameters Estimation for SOC and SOH of the Battery)

  • 박성준;송광석;박성미
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.853-863
    • /
    • 2020
  • As the battery ages, the internal resistance of the battery increases, so the loss due to the internal resistance increases at the same charging current, causing the battery temperature to rise, which further accelerates battery aging. Therefore, it is necessary to optimize the charging conditions according to the aging of the battery or the current charge amount, and to accurately estimate this, estimation of the parameters of the equivalent circuit is most important. This paper proposes a new measurement technique that can measure the internal resistance of a battery by analyzing a specific high frequency voltage and current applied to the battery. In addition, in order to test the validity of the proposed measurement technique, the current charging amount was estimated based on the measured internal resistance, and the terminal voltage of the constant current charging mode was automatically set and operated. As a result, good results were obtained regardless of the battery voltage. If this equipment is installed in the charging device, it is believed that it will be of great help in the stability management of the aging reusable battery.

배터리 잔량과 태스크에 따른 저전력 알고리즘 연구 (A Study on Low Power Algorithm for Battery residual capacity and a Task)

  • 김재진
    • 디지털산업정보학회논문지
    • /
    • 제9권1호
    • /
    • pp.53-58
    • /
    • 2013
  • In this paper, we proposed low power algorithm for battery residual capacity and a task. Algorithm the mobile devices power of the battery residual capacity for the task to perform power consumption to reduce the frequency alters. Task is different in power consumption according to kinds of in time accomplishment device to use. Adjustment of power consumption analyzes kinds of given tasks from having the minimum power consumption task to having the maximum power consumption task. Control frequency so that power consumption waste to be exposed to battery residual capacity can be happened according to the results analyzed. Experiment the frequency by adjusting power consumption a method to reduce using [7] and in the same environment power of the battery residual capacity consider the task to perform frequency were controlled. Efficiency was proved compare with the experiment results [7]. The experiments results show increment in the number of processing by 45.46% comparing with that [7] algorithm.

다중 마이크로콘트롤러를 사용한 배터리 관리 시스템의 개발 (Development of Battery Management System using Multiple Microcontroller)

  • 최정원;장운근
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.329-335
    • /
    • 2018
  • In an electric vehicle and Energy Storage System(ESS), a large number of batteries are connected in series or parallel to obtain high voltage and current. The battery management system(BMS) is needed because battery has a characteristic that explode in overcharging and overcurrent situations due to the nature of the battery material and the battery life is dramatically reduced when the battery is overdischarged below the specified voltage. In this paper, we proposed a system that can manage a large amount of batteries through the communication of master-slave type with multiple microcontroller. We confirmed the stable operation of the proposed system through the balancing-charging and storage mode experiments.

2-스위치 플라이백 컨버터를 이용한 배터리 밸런싱 기법 (Battery Balancing Method using 2-Switch Flyback Converter)

  • 김우준;김의진;박성미;박성준;손경종
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.451-459
    • /
    • 2022
  • Recently, in accordance with the demand for a large capacity of a secondary battery according to an increase in the demand for energy storage devices, a modular series battery configuration is essential. Accordingly, various cell balancing techniques have been proposed to prevent high efficiency and performance degradation of the battery. In this paper, propose a battery voltage balancing topology consisting of a flyback DC/DC converter type of a SIMO (Single-Input-Multiple Output) two-switch configuration for a series battery configuration. The proposed topology shows a structure in which a DC/DC converter connected to each module and a battery cell share one transformer. The topology cell balancing operation is a principle in which the voltage balancing converter of the battery converges to the same value through a transformer that shares a magnetic flux with the cells constituting the module through a single high-frequency transformer. In this paper, the dynamic characteristics analysis of the proposed circuit using PSIM was based and it was verified through experiments on one module.

Analysis of the Closed-Loop Supply Chain Focusing on Power Batteries in China

  • Chen, Jinhui;Jin, Chan-Yong
    • Journal of information and communication convergence engineering
    • /
    • 제19권2호
    • /
    • pp.84-92
    • /
    • 2021
  • The research on waste power batteries in China in the past ten years reveals that the power battery recycling industry is enormous but marred with several challenges. A study of China's current power battery closed-loop supply chain revealed some issues in the power battery recycling industry, such as imperfect supply chain, small recycling scale, asymmetric information, and imperfect profit distribution mechanism. This paper uses the theory of corporate social responsibility and consumer choice to propose a closed-loop network of power batteries based on block chain technology and analyzes the existing closed-loop supply chain of power batteries. Consequently, this study provides a new idea for developing the power battery closed-loop supply chain by proposing the closed-loop network of power batteries based on blockchain technology.

업종별 공기중 납입자의 입경별 분포특성에 관한 조사 연구 (A Study on the Characteristic of Airborne Lead Particle Size by Industry)

  • 박동욱;백남원
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.160-171
    • /
    • 1995
  • The size characteristics of lead particle which is one of the important factors associated with absorption of lead were ignored in establishing lead standard. This study was conducted to investigate distribution of lead particles by operation of industry. Aerodynamic Mass Median Diameters (MMD) of airborne lead particles in the battery and litharge manufacturing industry were $14.1{\mu}m$ and $15.1{\mu}m$, respectively. There was no significant difference between those two values(p>0.05). However, the diameters in radiator manufacturing and secondary smelting industry were $1.3{\mu}m$, $4.9{\mu}m$, respectively. Those were significantly smaller than the particle sizes in other industries(p<0.05). Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Concentrations of lead particles smaller than $1{\mu}m$ defined as respirable fraction by OSHA's CPA model assumption were $72.4{\mu}g/m^3$ in the secondary smelting industry, exceeding $50{\mu}g/m^3$. The relationship of concentrations between total lead and lead of particles smaller than $1{\mu}m$ was log Y = 0.46 logX + 0.06(n=119, $r^2=0.44$, p=0.0001). Relationship of respirable lead concentrations between OSHA and ACGIH was significantly detected in the litharge and battery manufacturing industry(p=0.0001), but was not significant in the radiator(p=0.2720) and secondary smelting manufacturing industry(p=0.2394). As MMDs of lead particles generated in industry were small, difference of respirable lead concentration between OSHA and ACGIH became smaller. There was a significant difference between concentrations respirable lead defined by two organizations such as OSHA and ACGIH in the battery and litharge manufacturing industry. Average concentration of respirable lead by ACGIH definition was 43.3 % of total lead in secondary smelting and 48.9 % in radiator manufacturing industry, and lower fractions were indicated in battery and litharge manufacturing industry. Relationships of total lead with IPM, TPM, and RPM were significant respectively(p=0.0001) and lead concentrations by particle size could be estimated using this relationship. Linear regression equation between total lead concentration(X) and ACGIH-RPM concentration(Y) was log Y = 0.76 log X - 0.40($r^2=0.89$, p=0.0001).

  • PDF

해수 전지용 탄소계 촉매와 Hydrogel 촉매의 제조 및 이들의 전기화학적 특성 비교 (Preparation and Electrochemical Performances Comparison of Carbon and Hydrogel Electrocatalysts for Seawater Battery)

  • 김경호;나영수;이만성
    • 전기화학회지
    • /
    • 제21권4호
    • /
    • pp.61-67
    • /
    • 2018
  • 새로운 전자 기기들이 등장함에 따라 시판되고 있는 리튬 이온 배터리 (lithium ion battery, LIB)는 다양한 문제에 직면해 있으며, 이와 관련하여 많은 해결 노력들이 시도되어 왔다. 차세대 이차 전지의 개발이라는 관점에서 LIB의 문제들을 해결하기 위해, 우리는 mesoporous carbon based on waste biomass (MCWB) 와 Polypyrrole (PPY) hydrogel과 같은 두 가지 종류의 촉매를 성공적으로 개발하였다. MCWB와 PPY hydrogel 촉매들은 전형적인 H3 타입 BET isotherm을 나타내었으며, 이는 micropore와 mseopore가 존재한다는 증거이다. 특히 PPY hydrogel을 기반으로 하는 해수 전지(seawater battery, SWB)의 경우, galvanostatic charge-discharge 시험에서 voltage efficiency성능은 MCWB를 적용한 battery보다 높았지만 Pt/C를 적용한 battery보다는 낮았다. 더욱 흥미롭게도, PPY hydrogel 기반의 SWB는 20 사이클(480hrs) 동안 우수한 가역적인 충/방전 특성을 나타내었으며, voltage efficiency성능은 70.32%에서 77.35% 범위의 우수한 특성을 나타내었다. 상기 연구 결과는 차세대 이차 전지를 위한 비귀금속 촉매 개발에 기여하는 결과라고 사료된다.

이동식 에너지 뱅크용 대용량 배터리 충전 시스템의 개발 (Development of the High Power Battery Charging System for Portable Energy Banks)

  • 김수연;김동옥;이정환;박성준
    • 한국산업융합학회 논문집
    • /
    • 제24권4_2호
    • /
    • pp.491-499
    • /
    • 2021
  • Batteries are widely used for energy storage, such as ESS(Energy Storage System), electric vehicles, electric aircraft, and electric powered ships. Among them, a submarine uses a high power battery for an energy storage. When the battery of a submarine is discharged, a diesel generator generates AC power, and then AC/DC power converter change AC power to DC power for charging the battery. Therefore, in order to lower the current capacity of the diesel generator, it is necessary to use an AC/DC converter with a high input power factor. And, a power converter with a large power capacity must have high stability because it can lead to a major accident when a failure occurs. However, the control algorithm using the traditional PI controller is difficult to satisfy stability and dynamic characteristics. In this paper, we design the high power AC/DC converter with high input power factor for battery charging systems. And, we propose a stable control algorithm. The validity of the proposed method is verified through simulation and experiments.