• 제목/요약/키워드: Basement structure

검색결과 210건 처리시간 0.03초

중진지역 건축물의 묻힌온통기초에 작용하는 토압과 말 뚝변위에 대한 지진해석 (Seismic Analyses of Soil Pressure against Embedded Mat Foundation and Pile Displacements for a Building in Moderate Seismic Area)

  • 김용석
    • 한국지진공학회논문집
    • /
    • 제21권1호
    • /
    • pp.69-76
    • /
    • 2017
  • Seismic analyses of a pile under a large rigid basement foundation embedded in the homogeneous soil layer were performed practically by a response displacement method assuming a sinusoidal wave form. However, it is hard to take into account the characteristics of a large mat foundation and a heterogeneous soil layer with the response displacement method. The response displacement method is relevant to the 2D problems for longitudinal structures such as tunnel, underground cave structure, etc., but might not be relevant with isolated foundations for building structures. In this study, seismic pile analysis by a pseudo 3D finite element method was carried out to compare numerical results with results of the response displacement method considering 3D characteristics of a foundation-soil system which is important for the building foundation analyses. Study results show that seismic analyses results of a response displacement method are similar to those of a pseudo 3D numerical method for stiff and dense soil layers, but they are too conservative for a soft soil layer inducing large soil pressures on the foundation wall and large pile displacements due to ignored foundation rigidity and resistance.

Evaluation of early age mechanical properties of concrete in real structure

  • Wang, Jiachun;Yan, Peiyu
    • Computers and Concrete
    • /
    • 제12권1호
    • /
    • pp.53-64
    • /
    • 2013
  • The curing temperature is known to influence the rate of mechanical properties development of early age concrete. In realistic sites the temperature of concrete is not isothermal $20^{\circ}C$, so the paper measured adiabatic temperature increases of four different concretes to understand heat emission during hydration at early age. The temperature-matching curing schedule in accordance with adiabatic temperature increase is adopted to simulate the situation in real massive concrete. The specimens under temperature-matching curing are subjected to realistic temperature for first few days as well as adiabatic condition. The mechanical properties including compressive strength, splitting strength and modulus of elasticity of concretes cured under both temperature-matching curing and isothermal $20^{\circ}C$ curing are investigated. The results denote that comparing temperature-matching curing with isothermal $20^{\circ}C$ curing, the early age concretes mechanical properties are obviously improved, but the later mechanical properties of concretes with pure Portland and containing silica fume are decreased a little and still increased for concretes containing fly ash and slag. On this basement using an equivalent age approach evaluates mechanical properties of early age concrete in real structures, the model parameters are defined by the compressive strength test, and can predict the compressive strength, splitting strength and elasticity modulus through measuring or calculating by finite element method the concreted temperature at early age, and the method is valid, which is applied in a concrete wall for evaluation of crack risking.

아파트 지하주차장의 균열방지 대책 - 현장사례조사를 중심으로 - (A Study on the Flaw Prevention Countermeasure of Crack in Apartment House Underground Parking Area)

  • 정순오;서상욱
    • 한국건설관리학회논문집
    • /
    • 제3권1호
    • /
    • pp.115-123
    • /
    • 2002
  • 공간의 효율적 이용 및 법정 주차대수 확보 등으로 아파트 단지의 지하층은 대부분 지하주차장으로 활용되고 있으며, 주차장상부도 시공 중에 성토 및 포장공사가 완성되지 않은 상태에서 작업차량의 통로 및 자재 야적장으로 사용되고 있어 과하중이 작용되고 있는 실정이다. 그러므로 시공중이거나 완공된 지하구조물에서 지속적으로 균열 및 누수현상이 발생하여 구조물의 성능저하는 물론 많은 금액의 하자보수비 투입, 민원유발 및 대외적인 신뢰도 저하 등 많은 문제점이 발생하고 있다. 따라서 본 연구의 목적은 시공중인 아파트와 준공된 아파트 지하주차장을 대상으로 현장조사를 실시하고, 그동안 실시한 안전진단 사례를 참고하여 아파트 지하주차장의 균열 및 누수현상 원인을 파악하고 그에 따른 설계 및 시공상의 방지대책을 마련하는데 있다.

미국흰불나방(Hyphantria cunea Drury) 정소(精巢)에 관한 연구 I. 정소(精巢)의 미세구조(微細構造) (Studies on the Testis of the Fall-web worms, Hyphantria cunea Drury I. Fine Structure of the Testis)

  • 문명진;이근옥;김창환;김우갑
    • Applied Microscopy
    • /
    • 제18권1호
    • /
    • pp.49-59
    • /
    • 1988
  • Fine structures of the testis and vas deferens in the fall-web worm, Hyphantria cunea Drury, are studied with electron microscope. Adult worms have single testis close to the midlines of the abdomen. Testis is composed of 4 follicles which are incompletly separated from each other and bounded together by a peritoneal sheath. The peritoneal sheath consisted of outer cuticular layer and two kinds of inner layers, in which glycogen particles are dispersed commonly. These two layers are divided by the morphology of cytoplasmic granules. Follicular epithelium forming the wall of the follicles have melanin pigment granules, and trachea or tracheoles are extended through this epithelium. In the cysts of adult testis, matured spermatozoa are grouped together in bundles and after releasing the sperm bundles to the vas deferens, lamellar shaped lysosomes appeared in the cytoplasms of the cyst cells. The number of spermatozoa per cyst is exactly 256 ($2^8$), this number is characteristics of the Lepidoperan species. Vas deferens is a tube with a fairly thick bounding epithelium, a basement membrane and a layer of circular muscle outside it. At the apical portion of the epithelial cells, microvilli are well developed. And in the cytoplasms of these cells, numerous excretory granules are observed.

  • PDF

Raffles City in Hangzhou China -The Engineering of a 'Vertical City' of Vibrant Waves-

  • Wang, Aaron J.
    • 국제초고층학회논문집
    • /
    • 제6권1호
    • /
    • pp.33-47
    • /
    • 2017
  • This mixed-use Raffles City (RCH) development is located near the Qiantang River in Hangzhou, the capital of Zhejiang province, located southwest of Shanghai, China. The project incorporates retail, offices, housing, and hotel facilities and marks the site of a cultural landscape within the Quianjiang New Town Area. The project is composed of two 250-meter-tall twisting towers with a form of vibrant waves, along with a commercial podium and three stories of basement car parking. It reaches a height of 60 stories, presenting views both to and from the Qiantang River and West Lake areas, with a total floor area of almost 400,000 square meters. A composite moment frame plus concrete core structural system was adopted for the tower structures. Concrete filled steel tubular (CFT) columns together with steel reinforced concrete (SRC) beams form the outer moment frame of the towers' structure. The internal slabs and floor beams are of reinforced concrete. This paper presents the engineering design and construction of this highly complex project. Through comprehensive discussion and careful elaboration, some conclusions are reached, which serve as a reference guide for the design and construction of similar free-form, hybrid, mix-use buildings.

무당개구리(Bombina orientalis Boulenger)皮膚 黃色素細胞(Xanthophore)의 分化에 관한 硏究 (The Cutaneous Xanthophore Differentiation in Bombina orientalis)

  • 문명진;김우갑;김창환
    • 한국동물학회지
    • /
    • 제29권4호
    • /
    • pp.261-271
    • /
    • 1986
  • 무당개구리(Bombina orientalis Boulenger)背皮의 청록색 발현에 관여하는 黃色素細胞(xanthophore)의 분화과정을 광학 및 전자 현미경으로 관찰하였다. 성체의 개구리에서 관찰되는 황색소세포는 pterinosome과 carotenoid vesicle등 2가지 색소과립을 함유하고 있으며, 진피의 다른 색소세포들과 複合體를 이루어 기저막을 따라 길게 세포질의 돌기를 뻗고 있었다. 최초의 황생소세포는 幼生期의 섭식시기를 전후하여 진피층에 나타나는 rER이 풍부한 세포와 Golgi complex가 풍부한 세포로부터 發生, 分化하며 변태의 각 단계를 거치면서 점진적으로 색소과립의 형성이 이루어진다. 변태가 완료되는 시기를 전후하여 pterinosnme의 급격한 증가현상이, 그리고 동면기 이후에는 carotenoid vesicle의 증가 현상이 관찰되는데, 이들 색소과립은 분화의 정도에 따라 여러 가지 구조를 나타내었다.

  • PDF

구한말 서울 정동의 러시아공사관에 대한 복원적 연구 (A Study on the Restoration of the Russian Legation in Jeongdong Seoul in the Latter Era of Choseon Dynasty)

  • 김정신;발레리 알렉산드로비치 사보스텐코;김재명
    • 건축역사연구
    • /
    • 제19권6호
    • /
    • pp.61-78
    • /
    • 2010
  • Old Russian Legation(1890) has been attracted public attention in terms of politics and foreign affairs than architectural style because of conditions of location and historical incident. Though it was heavily damaged during the Korean war, and only the tower has been restored, it is very important in architectural history in Korea, because it is the oldest western style brick building which is existing with the old bishop's house in Myeong-Dong. But it has been impossible to reveal exactly the original form as there has been few reliable materials(picture, drawing, document) and it's remains were nearly destroyed owing to development of the surroundings. Recently the decisive document(site outline map) was found, and new research on the architect Sabatine was studied. So I can get into close with the original form by the results. In this study, I tried to conjecture the original form of the old Russian legation(the size, style, plan and indoor space, arrangement of attached facilities) and I checked the location and structure of the room where King Gojong stayed when he took refuge, and the use of the passage in the basement.

How to reduce short column effects in buildings with reinforced concrete infill walls on basement floors

  • Bikce, Murat
    • Structural Engineering and Mechanics
    • /
    • 제38권2호
    • /
    • pp.249-259
    • /
    • 2011
  • Band windows are commonly used in reinforced concrete structures for the purpose of ventilation and lighting. These applications shorten the lengths of the columns and, consequently, they are subject to higher shear forces as compared with those of hollow frames. Such short columns may cause some damages during earthquakes. Hence, these effects of short columns should be minimized by choosing the dimensions of the band windows properly in order to prevent serious damages in the structure. This can be achieved by taking into account the parameters that are crucial in causing short column effect. Hence, in this study, the effects of those parameters such as the widths and heights of the band windows, the number of bays and storeys within the frame, and the heights of storeys are examined. The effects of the parameters are analyzed using time history analysis. One of the important results of these analyses, is that, the widths of the band windows should be less than 60% of the clear span between the columns, whereas, their heights should be greater than 35% of the clear storey height in order to decrease the short column effects substantially during the design of the reinforced concrete structures.

Structural Design of High-Rise Concrete Condominium with Wall Dampers for Vibration Control

  • Tsushi, Takumi;Ogura, Fumitaka;Uekusa, Masahiro;Kake, Satoshi;Tsuchihashi, Toru;Yasuda, Masaharu;Furuta, Takuya
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.201-209
    • /
    • 2019
  • This paper presents a structural design of the "(Tentative Name) Toranomon Hills Residential Tower" which is currently under construction in Tokyo. The building is a reinforced concrete high-rise residential complex building with 54 stories above ground, 4 basement levels, and a building height of about 220 m. It is a requirement to provide the highest grade of residence in Japan, and in terms of the structural design, it is required to provide wide and comfortable spaces with high seismic performance. These requirements are satisfied by providing a total of 774 vibration control walls of two types. Also, to further improve the structural performance, steel fibers at the rate of 1.0vol% are provided in the ultra-high strength concrete used in the column members.

노후 건축물의 콘크리트 탄산화 깊이 측정과 시차열 중량분석을 통한 탄산화도 및 CO2 흡수량 실험적 평가 (Measurement of carbonation depth of concrete in old buildings and experimental evaluation of carbonation degree and CO2 absorption using differential thermal gravimetric analysis)

  • 이상현;기전도;조홍범;박창건;김영선;문형재
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2022
  • Based on the carbonation depth measurement by the indicator for concrete collected from old structures and the quantitative analysis of Ca(OH)2 and CO2 in the carbonation section before and after the carbonation depth and in the non-carbonation section, the absorbable CO2 amount and carbonation degree measurement result is as follows 1) The carbonation depth of the 40-year-old reinforced concrete structure was measured to be about 22 mm. (basement interior wall, marble finish, strength 30MPa) 2) The amount of CO2 absorbed by the concrete was about 4.3% of the sample weight, and the carbonation degree was estimated to be about 53%.

  • PDF