• 제목/요약/키워드: Basement Wall

검색결과 80건 처리시간 0.03초

합성 지하벽의 전단내력 산정에 관한 실험적 연구 (Experimental Study on the Shear Capacity of Composite Basement Walls)

  • 김성만;이성호;서수연;이리형;홍원기;장재호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.379-384
    • /
    • 2001
  • This paper presents the experimental result of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector. Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, arrangement of shear connector, thickness of wall, shear span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

  • PDF

지하외벽슬래브의 부재력 분포에 대한 수치적 연구

  • 김영찬;김동건
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2002년도 춘계 학술논문발표회 논문집
    • /
    • pp.271-276
    • /
    • 2002
  • A numerical study using linear finite element analysis is performed to investigate the behavior of basement wall subject to soil and water pressure in this study, parametric studies are peformed to investigate the variation of moment and shear force according to column-to-wall stiffness ratios and aspect ratios. Scaled factors applicable to the design of basement wall are proposed with the illustration of design examples.

  • PDF

합성 지하벽의 전단성능 (Shear Capacity of Composite Basement Walls)

  • 김성만;이성호;서수연;이리형
    • 콘크리트학회논문집
    • /
    • 제14권3호
    • /
    • pp.321-330
    • /
    • 2002
  • 본 연구는 H-pile과 철근콘크리트 벽체를 전단연결재인 스터드 볼트를 사용하여 합성시킨 합성지하벽의 전단성능에 대한 실험연구 결과와 전단내력 산정시 적용시킬 수 있는 방안을 제시하고 있다. 합성지하벽의 전단성능에 영향을 미칠 합성율, 스터드볼트의 배치방법, 콘크리트벽체의 두께, 전단스팬비 및 전단보강근량을 주요변수로 선정하여 12개의 실험체를 제작하였다. 합성율을 제외한 주요 변수들은 합성지하벽의 전단내력에 영향을 미치는 것으로 나타났다. 아울러 합성지하벽의 전단내력 산정시 V=(Vc+Vre)+Vs라는 전단내력식을 기본식으로 하여 기존의 철근 콘크리트 전단내력식으로 제안된 ACI 318-99와 Zsutty식, Bazant식 그리고 철골의 전단내력식으로 제안된 강구조 한계상태 설계법에서 제시하고 있는 식으로 계산한 결과가 실험결과와 유사하게 나타남을 볼 수 있었다. 또한 소정의 합성율이 확보될 경우, 철골부재와 콘크리트벽체가 최대내력시까지 일체로 거동하며, 이를 고려하여 전단내력 산정시 합성부재의 전체깊이를 적용한 경우, 기존의 내력식을 이용하여 합성지하벽의 전단내력 예측이 가능할 것으로 판단된다.

Investigation of three-dimensional deformation mechanisms of box culvert due to adjacent deep basement excavation in clays

  • Bu, Fanmin;Yu, Wenrui;Chen, Li;Wu, Erlu
    • Geomechanics and Engineering
    • /
    • 제30권6호
    • /
    • pp.565-577
    • /
    • 2022
  • In this study, a series of three-dimensional numerical parametric study was conducted to investigate deformation mechanisms of an existing box culvert due to an adjacent multi-propped basement excavation in clays. Field measurements from an excavation case history are first used to calibrate a baseline Hardening Soil Small Strain (HS-small) model, which is subsequently adopted for parametric study. Results indicate that the basement-box culvert interaction along the basement centerline can be considered as a plane strain condition when the length of excavation (L) reaches 14 He (i.e., final excavation depth). If a plane strain condition (i.e., L/He=12.0) is assumed for analyzing the basement-box culvert interaction of a short excavation (i.e., L/He=2.0), the maximum settlement and horizontal movement of the box culvert are overestimated significantly by up to 15.7 and 5.1 times, respectively. It is also found that the deformation of box culvert can be greatly affected by the basement excavation if the distance between the box culvert and retaining wall is less than 1.5 He. The induced deformation in the box culvert can be dramatically reduced by improving the ground inside the excavation or implementing other precautionary measures. For example, by adding jet grouting columns within the basement and installing an isolation wall behind the retaining structures, the maximum settlements of box culvert are shown to reduce by 37.2% and 13.4%, respectively.

Passive p-y curves for rigid basement walls supporting granular soils

  • Imad, Elchiti;George, Saad;Shadi S., Najjar
    • Geomechanics and Engineering
    • /
    • 제32권3호
    • /
    • pp.335-346
    • /
    • 2023
  • For structures with underground basement walls, the soil-structure-interaction between the side soil and the walls affects the response of the system. There is interest in quantifying the relationship between the lateral earth pressure and the wall displacement using p-y curves. To date, passive p-y curves in available limited studies were assumed elastic-perfectly plastic. In reality, the relationship between earth pressure and wall displacement is complex. This paper focuses on studying the development of passive p-y curves behind rigid walls supporting granular soils. The study aims at identifying the different components of the passive p-y relationship and proposing a rigorous non-linear p-y model in place of simplified elastic-plastic models. The results of the study show that (1) the p-y relationship that models the stress-displacement response behind a rigid basement wall is highly non-linear, (2) passive p-y curves are affected by the height of the wall, relative density, and depth below the ground surface, and (3) passive p-y curves can be expressed using a truncated hyperbolic model that is defined by a limit state passive pressure that is determined using available logarithmic spiral methods and an initial slope that is expressed using a depth-dependent soil stiffness model.

도심지 지하굴착에 적용된 Top-Down 공법의 수치해석과 실측비교 (Top-Down Method of Deep Basement Construction in Urban Area : a Comparison of Numerical Analysis and Field observation Data)

  • 김학문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1991년도 추계학술발표회 논문집 지반공학에서의 컴퓨터 활용 COMPUTER UTILIZATION IN GEOTECHNICAL ENGINEERING
    • /
    • pp.312-331
    • /
    • 1991
  • 런던시내의 역사적 건물들 주변에서 LONDON CLAY층을 굴착하고 지하 5층의 주차장 건설에 TOP-DOWN공법이 적용되었다. 인접 구조물들의 안전진단을 수치해석(F.E.M)으로 예측하고 현장에서 실측한 자료와 비교분석하였다. 사용된 탄소성 COMPUTER 모델은 현장계측값들과 비교적 잘 일치하고 있으며, 지하 연속벽(DIAPHRAGM WALL)을 이용한 TOP-DOWN공법이 주변지반 변형을 감소시킬 수 있는 가장 효과적인 방법으로 판명되었다.

  • PDF

고강도 강관파이프 스트러트 흙막이공법 사례연구 (Case Study of Braced Wall System with High-strength Steel Pipe Strut)

  • 신재민;박현영;주진규;신윤석;김광희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.19-20
    • /
    • 2012
  • According to develop urban area, the depth and floor area of basement tend to become deeper and larger. Excavation work for basement floor work is very important because its cost take 20% of total construction cost. Therefore, many studies of developing retaining wall system have performed for feasibility and safety in deep excavation work. In this study, new supporting system used high-strength pipe for retaining wall is introduced to reduce the construction cost and improve the safety and constructability by analyzing case study.

  • PDF

초고층 주상복합 건물에의 초고강도 콘크리트의 시공 및 구조적 성능 (the Application and Structural Behavior of Ultra High Strength Concrete on Sam Sung Sin-Dae Bang project.)

  • 신성우;이광수;최종수;유석형;안종문;윤영수;성상래;백승준;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.313-318
    • /
    • 1994
  • This paper present the application and Structural Behavior of Ultra-High Strength Concrete on Samsung Sin Dae-Bang Housing-Commercial Combined building with 28 story including 8 story basement in seoul. 70 MPa compressive strength has been placed for all 8 basement shear wall. 42 MPa design strength concrete was used for other basement and frame up to 10th floor which us used for commercial purposes

  • PDF

범용 생산설비를 활용한 PC 더블월 제작 및 시공성에 관한 연구 (Fabrication and Constructability of a General-Purpose Manufactured Precast Concrete Double Wall)

  • 박순전
    • 한국건축시공학회지
    • /
    • 제23권4호
    • /
    • pp.465-476
    • /
    • 2023
  • 공동주택 지하층 공사시 발생하는 생산성 저하 문제를 해결하기 위한 개선책으로 필요한 PC 더블월(Double Wall) 공법을 개발하였다. 개발 공법은 기존의 PC 더블월 공법과 차별화되어, 지하 주동부의 다양한 PC 형상에 대응할 수 있고, 수평 및 수직 재하 등 부담 하중의 축력비에 충분히 견딜 수 있는 구조적으로 안전한 PC 더블월 공법으로서, 현장 테스트베드를 통하여 설계 및 제작기술, 그리고 시공기술의 적용성 분석하고 개발 공법의 실물 사이즈에 대한 목업테스트를 통해 품질성능을 검토하였다. 목업 테스트 수행 결과, PC 더블월의 기립 설치 및 내부 채움 콘크리트 타설시 균열이나 변형은 관측되지 않아, 구조적으로 안전한 것으로 나타났으며, 내부 채움 콘크리트는 양호한 품질 상태를 유지하였다. 복합적인 요인으로 인해 개발 공법을 실제 APT 주동부 지하층에 적용하지 못해 개발공법의 시공성 분석은 개발 자료를 기반으로한 설치 전문가들의 인터뷰를 통해 분석하였다. 개발 디테일을 적용하여 PC 더블월을 두가지 폭(W=2.4m, W=3.2m)으로 제작하여 설치하는 경우에 대해 PC 부재 설치 전문가 3명과 인터뷰를 수행하였다. 재래식 현장 타설 공법이 통상 47일/층~68일/층 소요되는 데 반해, 제안공법을 적용하면 공기일수가 20일/층~29일/층 소요되는 것으로 나타나, 공기단축 측면에서 효과가 큰 것으로 나타났다. 추후 연구 수행 방향으로서, 실제 APT 주동부 지하층에 적용하여, 시공상 관리 이슈를 추가적으로 도출하고, 공기단축 및 품질 유지에 대한 결과를 검증할 예정이다.

전단경간비에 따른 합성지하벽의 거동과 접촉면의 조건을 고려한 유한요소 해석 (Structural Behavior of Composite Basement Wall According to Shear Span-to-Depth Ratio and FE Analysis Considering the Condition of Contact Surface)

  • 서수연
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권6호
    • /
    • pp.118-126
    • /
    • 2011
  • 본 연구의 목적은 전단경간비에 따른 합성지하벽의 거동을 실험적으로 연구하고 유한요소해석 프로그램인 ADINA를 활용하여 합성지하벽 (Composite Basement Wall, CBW)의 비선형 거동의 예측이다. 특히 각 층 바닥 부근과 같이 콘크리트가 압축응력상태일 때의 합성벽의 거동을 연구하였다. 특히 강재와 콘크리트가 접촉되는 부분의 모델링 방법에 따른 해석방법의 적합성을 검토하고자 하였다. 콘크리트 벽체부분이 압축응력상태에 있는 합성지하벽의 거동을 이해하기 위하여 합성지하벽에 대한 실험을 실시하고 ADINA 프로그램을 이용하여 유한요소해석을 실시하였다. 해석의 편의를 위하여, 철근은 별도의 독립 요소로 모델링하지 않고, 콘크리트에 등분포되어 콘크리트와 함께 거동하는 것으로 하고 모든 요소는 소성거동을 표현하기 위하여 이선형 모델로 하였다. 강재와 콘크리트의 접촉면과 관련해서는 접촉면의 연결조건에 따라, AGO, SEGO-T 그리고 SEGO-NT로 모델링하여 해석을 실시한 뒤 각 조건에 따른 응력흐름과 집중정도를 관찰하고 그 결과를 실험결과와 비교하였다. 연구결과, 합성지하벽은 전단경간비가 비록 1에 가깝더라도, 강재의 소성변형에 의해 충분히 연성적인 거동을 보이는 것으로 나타났으며, 이와 같은 거동을 묘사하기 위하여 ADINA 프로그램을 이용하여 콘크리트와 강재 및 스터드볼트의 비선형특성을 고려하고 접촉면 요소로서 강재와 콘크리트의 접합면을 모델링하여 해석한 결과 접촉면연결과 모든 절점공유 옵션을 사용한 모델을 적용할 경우, 실험결과와 근사한 예측이 가능한 것으로 나타났다.