• Title/Summary/Keyword: Baseline Test

Search Result 1,002, Processing Time 0.029 seconds

Detection of ST-T Episode Based on the Global Curvature of Isoelectric Level in ECG (ECG 신호의 global curvature를 이용한 ST-T 에피소드 검출)

  • Kang, Dong-Won;Jun, Dae-Gun;Lee, Kyoung-Joung;Yoon, Hyung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.4
    • /
    • pp.201-207
    • /
    • 2001
  • This paper describes an automated detection algorithm of ST-T episodes using global curvature which can connect the isoelectric level in ECG and can eliminate not only the slope of ST segment, but also difference of the baseline and global curve. This above method of baseline correction is very faster than the classical baseline correction methods. The optimal values of parameters for baseline correction were found as the value having the highest detection rate of ST episode. The features as input of backpropagation Neural Network were extracted from the whole ST segment. The European ST-T database was used as training and test data. Finally, ST elevation, ST depression and normal ST were classified. The average ST episode sensitivity and predictivity were 85.42%, 80.29%, respectively. This result shows the high speed and reliability in ST episode detection. In conclusion, the proposed method showed the possibility in various applications for the Holter system.

  • PDF

ADA: Advanced data analytics methods for abnormal frequent episodes in the baseline data of ISD

  • Biswajit Biswal;Andrew Duncan;Zaijing Sun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.3996-4004
    • /
    • 2022
  • The data collected by the In-Situ Decommissioning (ISD) sensors are time-specific, age-specific, and developmental stage-specific. Research has been done on the stream data collected by ISD testbed in the recent few years to seek both frequent episodes and abnormal frequent episodes. Frequent episodes in the data stream have confirmed the daily cycle of the sensor responses and established sequences of different types of sensors, which was verified by the experimental setup of the ISD Sensor Network Test Bed. However, the discovery of abnormal frequent episodes remained a challenge because these abnormal frequent episodes are very small signals and may be buried in the background noise of voltage and current changes. In this work, we proposed Advanced Data Analytics (ADA) methods that are applied to the baseline data to identify frequent episodes and extended our approach by adding more features extracted from the baseline data to discover abnormal frequent episodes, which may lead to the early indicators of ISD system failures. In the study, we have evaluated our approach using the baseline data, and the performance evaluation results show that our approach is able to discover frequent episodes as well as abnormal frequent episodes conveniently.

Effect of Cellular Phone on Fetal Heart Rate Patterns

  • Jafarabadi, Mina;Jafarabadi, Ladan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.181-184
    • /
    • 2004
  • There are reports showing that electromagnetic fields (EMFs) emitted at non-thermal levels may be associated with biological alterations in target cells. In this study it is objected to assess the potential influences of EMFs produced by cellular phones on fetal heart rate. Non Stress Test (NST) is a widely used method of fetal monitoring and assessing fetal health and well-being. Sixty volunteers with uncomplicated term pregnancies were studied by a Spacelabs AM-67 Doppler ultrasound monitor. Fetal Heart Rate recordings were obtained while there were no Cellular Phone around for 10 minutes. Afterwards, all patients were exposed to EMFs for 10 minutes. NST was performed while they were holding the CP on stand-by mode and then on dialing mode, each for 5 minutes. The recordings were analyzed with respect to baseline heart rate, accelerations and decelerations. The Wilcoxon matched-pairs signed-ranks test was used to compare these variables. The results indicate that EMFs emitted by CP do not cause any demonstrable effects on baseline FHR, acceleration or deceleration.

  • PDF

Neural Networks-Based Damage Detection for Bridges Considering Errors in Baseline Finite Element Models (모델링 오차를 고려한 신경망 기법 기반 손상추정방법)

  • Lee, Jong-Jae;Yun, Chung-Bang;Lee, Jong-Won;Jung, Hie-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.382-387
    • /
    • 2003
  • In this paper, a neural networks-based damage detection method using the modal properties is presented, which can effectively reduce the effect of the modeling errors in the baseline finite element model from which the training patterns for the networks are to be generated. The differences or the ratios of the mode shape components between before and after damage are used as the input to the neural networks in this method, since they are found to be less sensitive to the modeling errors than the mode shapes themselves. Results of laboratory test on a simply supported bridge model and field test on a bridge with multiple girders confirm the applicability of the present method.

  • PDF

A Study on Performance evaluation of digital filter Removal of baseline wandering for accurate ST segment analysis (ST 세그먼트 분류를 의한 기저선 제거용 디지탈 필터의 성능 분석)

  • Jang, Jae-Ho;Lee, Byung-Chae;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.141-144
    • /
    • 1993
  • This paper propose a two pole phase compensated titer to remove baseline wandering and preserve ST-segment accuracy in real time environment. Bilinear transformed null phase filter(ideal filter), Standard FIR filter and Cubic spline filter are evalauated in the same condition. The proposed phase compensated filter shows better performance than standard filter in real ECG test and triangular pulse test.

  • PDF

Robust Histogram Equalization Using Compensated Probability Distribution

  • Kim, Sung-Tak;Kim, Hoi-Rin
    • MALSORI
    • /
    • v.55
    • /
    • pp.131-142
    • /
    • 2005
  • A mismatch between the training and the test conditions often causes a drastic decrease in the performance of the speech recognition systems. In this paper, non-linear transformation techniques based on histogram equalization in the acoustic feature space are studied for reducing the mismatched condition. The purpose of histogram equalization(HEQ) is to convert the probability distribution of test speech into the probability distribution of training speech. While conventional histogram equalization methods consider only the probability distribution of a test speech, for noise-corrupted test speech, its probability distribution is also distorted. The transformation function obtained by this distorted probability distribution maybe bring about miss-transformation of feature vectors, and this causes the performance of histogram equalization to decrease. Therefore, this paper proposes a new method of calculating noise-removed probability distribution by using assumption that the CDF of noisy speech feature vectors consists of component of speech feature vectors and component of noise feature vectors, and this compensated probability distribution is used in HEQ process. In the AURORA-2 framework, the proposed method reduced the error rate by over $44\%$ in clean training condition compared to the baseline system. For multi training condition, the proposed methods are also better than the baseline system.

  • PDF

The Effects of Home-Based Action Observation Training on Upper Extremity Function in Tumor-Induced Hemiparetic Patient : Single Case Study (동작관찰 훈련이 뇌종양으로 인한 편마비 환자의 상지기능과 삶의 질에 미치는 효과: 단일사례연구)

  • Jung, Jun-Sik;Park, Hae-Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.5 no.1
    • /
    • pp.55-65
    • /
    • 2016
  • Objective : This study aimed to investigate the effects of home-based action observation training on upper extremity in brain tumor patient. Methods : Among the single case study design, this experiment used ABA' design. The evaluations were carried out 4 times during pre baseline period(A) and post baseline period(A') respectively. At the intervention period(B), a total of 25 times of action observation training and 10 times of evaluation were administered. Results : Study results indicate that 9-hole peg test, Box and Block Test, Manual Function Test were increased when compared to action observation intervention(B) to pre intervention baseline(A). Conclusion : Based on these results, home-based action observation training may be an effective upper extremity intervention strategy for tumor-induced hemiparetic patient.

A Study on the accuracy of Rangefinder between vessels by use of GPS (GPS를 이용한 선간거리계의 정확도에 관한 연구)

  • 김광홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.215-226
    • /
    • 1999
  • The experimented rangefinder consist of sets of V/A-Code GPS and sets of L1 C/A-code & carrier phase receivers connected by two spread spectrum radio modems in order to measure relative range and bearing between two ship antennas by real time, comparing and analyzing accuracy of both GPS receivers at the fix point on the land by means of executing zero baseline test by C/A code and by carrier phase as well as measuring distance range 5m, 10m, 15m between each other receivers. The results from the measurement of relative range and bearing are as follows as ;1. According to the results from zero baseline test, the average error by C/A-code receiver is less than 0.1m, which proves theories from published books but when each GPS receivers track different satellites, the range accuracy error becomes up to 100m by means of S/A. Because of this sudden wide range error, rangefinder is not appropriate at relative range measurement without additional modification of the algorism of the GPS receiver itself.2. According to relative range measurement by Carrier Phase and zero baseline test at static condition, the range error is less than 3.5cm in case that it passes more than 5 minutes after GPS sets can track simultaneously more than 6 satellites. Its main reason is understood that the phase center of antenna is bigger than geodetic antenna.3. When range measurement of two receivers from 5m, to 10m to 15m, the each range error is 0.340m, 0.190m, 0.011m and each standard variation is 0.0973m, 0.0884m, 0.0790m. The range error and standard variation are in inverse proportion to distance between two receivers. 4. L1 Carrier Phase GPS generally needs 5 minutes to fix and during this ambiguity search, the relative range and bearing angle is shown to be various.

  • PDF

The Effect of Dual-task Gait Training on Balance, Gait, and Activities of Daily Living for Patients with Parkinson's Disease -A Single-subject Experimental Design- (이중과제 보행훈련이 파킨슨병 환자의 균형, 보행능력 및 일상생활동작에 미치는 효과 -단일사례연구-)

  • Park, Hyun-Ju;Lee, Eon-Ju;Na, Gyu-Min;Kang, Tae-Woo
    • PNF and Movement
    • /
    • v.17 no.3
    • /
    • pp.339-351
    • /
    • 2019
  • Purpose: This study identified the effects of dual-task gait training on balance, gait function, and activity of daily living in patients with Parkinson's disease. Methods: This study used a single-subject design. Two patients with Parkinson's disease participated in this study. Dual-task gait training was performed 1 hour per day 8 times during intervention phase. The subjects were measured 8 times in the baseline phase, 8 times in the intervention phase, and 8 times in the follow-up phase. The outcome measurements included a timed up and go test (TUG), a Berg balance scale (BBS), a 10 meter walk test (10MWT), a 6 minute walk test (6MWT), a dynamic gait index (DGI) and a Korean modified Barthel index (K-MBI). Results: When compared to the average of the baseline process, the data collected during the intervention period showed that the TUG and 10MWT results improved and the tendency line was above the baseline. In addition, BBS, 6MWT, DGI, and K-MBI values for both patients increased remarkably after the training. Conclusion: The results of this study revealed that dual-task gait training may be helpful to improve balance, walking function, and activity of daily living for patients with Parkinson's disease. Further studies need to confirm our findings.

A comparative study of the clinical effects of chitosan nanofiber membrane in the treatment of mandibular class II furcation defects (하악 2급 치근 이개부 병소에서 키토산 나노 차폐막을 이용한 치주조직 재생의 임상적 효과에 관한 비교 연구)

  • Choi, Han-Sun;Jeong, Lim;Kim, Jeong-Bin;Hong, Ki-Seok;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.703-718
    • /
    • 2005
  • The purpose of this study was to evaluate the clinical efficacy of guided tissue regeneration(GTR) technique using chitosan nanofiber membrane and to compare it to the clinical efficacy following GTR using PLA/PLGA(copolymer of polvlactic acid and polylacticglycolic acid) membrane in mandibular class II furcation defects in human. The chitosan nanofiber membranes were applied to the mandibular class II furcation defects of 13 patients(test group) and PLA/PLGA membranes were applied to those of 11 patients(control group). Probing pocket depth, clinical attachment level, gingival recession, plaque index and gingival index were measured at baseline and 3 months postoperatively. Vertical and horizontal furcation defect depth were measured at surgery. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-Whitney Test using SPSS program. The results were as follows: 1. Probing pocket depth, clinical attachment loss and gingival index were significantly reduced at 3 months postoperatively compared to values of baseline in both groups(p<0.05). 2. Gingival recession and plaque index were not significantly decreased at 3 months postoperatively compared to values of baseline in both groups. 3. No significant difference between two groups could be detected with regard to changes of probing pocket depth, gingival recession, clinical attachment level, plaque index and gingival index at 3 months postoperatively. In conclusion, chitosan nanofiber membrane is effective in the treatment of human mandibular class II furcation defects and a longer period study is needed to fully evaluate the outcomes.