• 제목/요약/키워드: Baseline Searching

검색결과 23건 처리시간 0.023초

EDISON Ksec2D와 Grid Search 법을 이용한 헬리콥터 블레이드 단면의 형상 최적화 (Optimization Study of a Helicopter Rotor Blade Section Using EDISON Ksec2D and Grid Search Method)

  • 나덕환;함재준;배재성
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제5회(2016년)
    • /
    • pp.183-189
    • /
    • 2016
  • In this paper, an optimization study on a helicopter rotor blade cross-section was made. Generalization was made to the baseline cross-section to simplify the analysis. To have better performance in aeroelastic response, with the aerodynamic center being the origin of the baseline, the distance between aerodynamic center and shear center, and the distance between mass center and shear center of the blade were minimized. For efficient searching of optimum solutions over the design space, grid search method, which is a method of graphical search was used. Two design variables, radius of balancing weight at leading edge, and offset of the spar from leading edge were selected for the study. Cubic spline interpolation method was used to accommodate searching of the optimum solution. 2-Leveled searching system was devised in accordance with the interpolation method. Optimum solution was found to show 6% decrease in both distance between aerodynamic center and shear center, and mass center and shear center to the baseline.

  • PDF

An efficient Ambiguity searching method with constraints for attitude finding GPS receivers

  • Nam, Sung-Il;Son, Seok-Bo;Park, Chan-Sik;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.61.1-61
    • /
    • 2001
  • This paper describes an efficient ambiguity searching method using additional constraints in 3-dimentional attitude finding GPS receiver design. For determining the integer ambiguity, the baseline length constraint, the angle constraint, the velocity constraint and the attitude constraint can be used for reducing the searching space. This paper describes the searching space algebraically and graphically. It is confirmed that the described restrictions are reasonable and the speed and the probability of ambiguity fixing are improved when the restricted searching spaces are applied Moreover, it is possible to design receivers of better quality by applying the method proposed in this paper.

  • PDF

문서 영상의 기울기 검출을 위한 기준선 탐색 기법 (Baseline Searching Method for Document Skew Detection)

  • 신명진;김도연;차의영
    • 한국멀티미디어학회논문지
    • /
    • 제10권2호
    • /
    • pp.218-225
    • /
    • 2007
  • 본 논문은 문자 인식 등을 통한 문서 자동 처리 시스템을 위해서 스캔 과정에서 발생할 수 있는 문서의 기울기를 정확하게 검출하는 기법을 제안한다. 제안한 알고리즘은 처리 속도 향상을 위해 영상을 축소한 다음 형태학적 연산과 연결 성분 분석 방법으로 기울기 검출 대상 영역(ROI)을 먼저 설정한 후 설정된 영역 내에서 문서의 기울기 정보를 가지고 있는 기준선을 탐색하는 방법으로 정확하게 기울어진 각도를 검출할 수 있게 하였다. 기존의 형태학적 연산을 기반으로 한 기울기 검출 기법과 비교하고 다양한 종류의 대용량 문서 영상을 대상으로 한 실험 및 분석을 통해 제안한 기울기 검출 방법의 정확도 및 효율성을 증명하였다.

  • PDF

A Simple and Robustness Algorithm for ECG R- peak Detection

  • Rahman, Md Saifur;Choi, Chulhyung;Kim, Young-pil;Kim, Sikyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2080-2085
    • /
    • 2018
  • There have been numerous studies that extract the R-peak from electrocardiogram (ECG) signals. All of these studies can extract R-peak from ECG. However, these methods are complicated and difficult to implement in a real-time portable ECG device. After filtration choosing a threshold value for R-peak detection is a big challenge. Fixed threshold scheme is sometimes unable to detect low R-peak value and adaptive threshold sometime detect wrong R-peak for more adaptation. In this paper, a simple and robustness algorithm is proposed to detect R-peak with less complexity. This method also solves the problem of threshold value selection. Using the adaptive filter, the baseline drift can be removed from ECG signal. After filtration, an appropriate threshold value is automatically chosen by using the minimum and maximum value of an ECG signals. Then the neighborhood searching scheme is applied under threshold value to detect R-peak from ECG signals. Proposed method improves the detection and accuracy rate of R-peak detection. After R-peak detection, we calculate heart rate to know the heart condition.

Scalable Re-detection for Correlation Filter in Visual Tracking

  • Park, Kayoung
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권7호
    • /
    • pp.57-64
    • /
    • 2020
  • 본 논문에서는 상관필터를 이용한 영상 추적에서 탐색 영역의 크기 조절이 가능한 재탐지 방법을 제안한다. 실제 장비를 통해 영상 추적 기능을 실행할 때에는 표적이 특정 물체에 가리고 다시 나타나는 일이 빈번하게 일어나는데, 따라서 표적의 소실 판단과 재탐지 방법이 필요하다. 본 알고리즘은 강인한 추적을 위해 커널 상관필터를 사용한다. 일반적인 상관필터를 활용한 영상 추적 알고리즘에서는 표적을 탐지하는 범위가 학습된 필터의 크기에 국한된다. 하지만 표적의 가림이 오랜 시간 지속될수록 표적의 위치는 예측된 위치에서 벗어날 가능성이 커지고, 따라서 충분히 큰 범위에서 표적의 탐색이 이루어져야 한다. 제안하는 방법은 매 프레임 2%씩 탐색 범위를 넓히며 재탐지를 시도하여 성공률을 높인다. 실험은 항공에서 촬영된 4가지 영상을 활용하였고, 제안한 알고리즘은 재탐지가 어려운 데이터셋에서도 성공적인 결과를 보였다.

Fast key-frame extraction for 3D reconstruction from a handheld video

  • Choi, Jongho;Kwon, Soonchul;Son, Kwangchul;Yoo, Jisang
    • International journal of advanced smart convergence
    • /
    • 제5권4호
    • /
    • pp.1-9
    • /
    • 2016
  • In order to reconstruct a 3D model in video sequences, to select key frames that are easy to estimate a geometric model is essential. This paper proposes a method to easily extract informative frames from a handheld video. The method combines selection criteria based on appropriate-baseline determination between frames, frame jumping for fast searching in the video, geometric robust information criterion (GRIC) scores for the frame-to-frame homography and fundamental matrix, and blurry-frame removal. Through experiments with videos taken in indoor space, the proposed method shows creating a more robust 3D point cloud than existing methods, even in the presence of motion blur and degenerate motions.

독립성분 분석기법에 의한 심전도 신호의 왜곡 보정 (Suppressing Artefacts in the ECG by Independent Component Analysis)

  • 김정환;김경섭;김현태;이정환
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.825-832
    • /
    • 2013
  • In this study, Independent Component Analysis (ICA) algorithms are suggested to extract the original ECG part from the mixed signal contaminated with the unwanted frequency components and especially 60Hz power line disturbances. With this aim, we implement a novel method to suppress the baseline-wandering disturbances and power line artefacts contained in patch-electrodes sensory ECG data by separating the unmixed signal with finding the optimal weight W based on Kurtosis value. With applying brutal force and gradient ascent searching algorithm to find W, we can conclude that the unwanted frequency components especially in the ambulatory ECG data can be eliminated by Independent Component Analysis.

Korean TableQA: Structured data question answering based on span prediction style with S3-NET

  • Park, Cheoneum;Kim, Myungji;Park, Soyoon;Lim, Seungyoung;Lee, Jooyoul;Lee, Changki
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.899-911
    • /
    • 2020
  • The data in tables are accurate and rich in information, which facilitates the performance of information extraction and question answering (QA) tasks. TableQA, which is based on tables, solves problems by understanding the table structure and searching for answers to questions. In this paper, we introduce both novice and intermediate Korean TableQA tasks that involve deducing the answer to a question from structured tabular data and using it to build a question answering pair. To solve Korean TableQA tasks, we use S3-NET, which has shown a good performance in machine reading comprehension (MRC), and propose a method of converting structured tabular data into a record format suitable for MRC. Our experimental results show that the proposed method outperforms a baseline in both the novice task (exact match (EM) 96.48% and F1 97.06%) and intermediate task (EM 99.30% and F1 99.55%).

기계환기기 이탈의 성공과 관련된 생리적${\cdot}$심리적 요인에 관한 조사 연구 (A Study on the Physiological and Psychological Factors related to Successful Weaning from a Mechanical Ventilator)

  • 김조자;김화순;장연수;김은성
    • 대한간호학회지
    • /
    • 제30권4호
    • /
    • pp.995-1005
    • /
    • 2000
  • This study was performed to identify the physiological and psychological variables related to successful weaning from a mechanical ventilator. The subjects of this study were 22 patients who received mechanical ventilation therapy for more than 3 days in intensive care units. Before the weaning trial, baseline data for following physiologic variables were obtained: spontaneous respiration rate, blood pressure, pulse rate, PaO2, PaCO2, PEEP, static compliance, minute ventilation, tidal volume, rapid shallow breathing index(f/VT), SaO2, PaO2/FiO2 and mean arterial pressure. During spontaneous breathing, physiologic and psychologic variables such as vital signs, ABG, perspiration, chest retraction, paradoxical respiration, dyspnea, anxiety, confidence and efficacy were measured. Successful weaning was defined as sustaining spontaneous respiration over 24 hours after extubation. Weaning failure was defined as the development of more than one of following signs: (1) hypoxemia, (2) CO2 retention or (3) perspiration, tachypnea, chest retraction, tachycardia, arrhythmia, hypotension or hypertension. Subjects (N=18) who successfully weaned from mechanical ventilator were compared with subjects (N=4) who failed. The results are as follows; Eighteen percents of the subjects failed during the weaning trial. Most subjects in the failed group were mechanically ventilated for long-time. This result shows that the success of weaning is more difficult in long-term ventilation patients. In the baseline data that was measured before weaning trial, the mean score of PaO2 in the successfully weaned group was 121mmHg. This is significantly higher than the mean score of PaO2 in the failed group(95mmHg). However, the scores of pH, tidal volume, f/VT, pulse rates, blood pressure, mean airway pressure, SaO2, and PaCO2 were similar between the two groups. Specially the scores of f/VT index as a predominant predictor for successful weaning were not significant (f/VT=44.4) and (f/VT=47). During spontaneous breathing, the scores of dyspnea and anxiety level in the successfully weaned group were less than those of the failed group. On the contrary, the scores of confidence and efficacy in the successful group were greater than those of the failed group. In conclusion, the baseline data that were measured before weaning trial were similar between the both groups, therefore future studies are needed to focus on searching other variables besides physiological parameters related to weaning outcome.

  • PDF

An SPC-Based Forward-Backward Algorithm for Arrhythmic Beat Detection and Classification

  • Jiang, Bernard C.;Yang, Wen-Hung;Yang, Chi-Yu
    • Industrial Engineering and Management Systems
    • /
    • 제12권4호
    • /
    • pp.380-388
    • /
    • 2013
  • Large variation in electrocardiogram (ECG) waveforms continues to present challenges in defining R-wave locations in ECG signals. This research presents a procedure to extract the R-wave locations by forward-backward (FB) algorithm and classify the arrhythmic beat conditions by using RR intervals. The FB algorithm shows forward and backward searching rules from QRS onset and eliminates lower-amplitude signals near the baseline using a statistical process control concept. The proposed algorithm was trained the optimal parameters by using MIT-BIH arrhythmia database (MITDB), and it was verified by actual Holter ECG signals from a local hospital. The signals are classified into normal (N) and three arrhythmia beat types including premature ventricular contraction (PVC), ventricular flutter/fibrillation (VF), and second-degree heart block (BII) beat. This work produces 98.54% accuracy in the detection of R-wave location; 98.68% for N beats; 91.17% for PVC beats; and 87.2% for VF beats in the collected Holter ECG signals, and the results are better than what are reported in literature.