• 제목/요약/키워드: Base plate materials

검색결과 93건 처리시간 0.028초

치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 - (THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS)

  • 이용근;이건일;정성우
    • 치과방사선
    • /
    • 제26권2호
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

PHOTOCATALYTIC ANTIEUNGAL ACTIVITY AGAINST CANDIDA ALBICANS BY $TiO_2$ COATED ACRYLIC RESIN DENTURE BASE

  • Yang Ji-Yeon;Kim Hee-Jung;Chung Chae-Heon
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.284-294
    • /
    • 2006
  • Statement of problem. Proliferation of Candida albicans is primarily within the plaque on the fitting surface of the denture rather than on the inflamed mucosa. Consequently, the treatment of the denture is equally important as treatment of the tissue. Cleansing and disinfection should be efficiently carried-out as the organisms can penetrate into the voids of the acrylic resin and grow in them, from which they can continue to infect and reinfect bearing tissues. Purpose. The purpose of this study was to evaluate the applicability of photocatalytic reaction to eliminate Candida albicans from acrylic resin denture base, and to investigate the anti-fungal effect with various UVA illumination time. Materials and Methods. The specimens were cured by the conventional method following the manufacturer's instruction using thermal polymerized denture base resin (Vertex RS: Dentimex, Netherlands). $TiO_2$ photocatalyst sol(LT), which is able to be coated at normal temperature, was made from the Ti-alkoxide progenitor. The XRD patterns, TEM images and nitrogen absorption ability of the $TiO_2$ photocatalyst sol(LT) were compared with the commercial $TiO_2$ photocatalyst P-25. The experimental specimens were coated with the mixture of the $TiO_2$ photocatalyst sol(LT) and binder material (silane) using dip-coater, and uncoated resin plates were used as the control group. Crystallinity of $TiO_2$ of the specimen was tested by the XRD. Size, shape and chemical compositions were also analyzed using the FE-SEM/ EDS. The angle and methylene blue degradation efsciency were measured for evaluating the photocatalytic activity of the $TiO_2$ film. Finally, the antifungal activity of the specimen was tested. Candida albicans KCTC 7629(1 ml, initial concentration $10^5$ cells/ ml) were applied to the experiment and control group specimens and subsequently two UVA light source with 10W, 353 nm peak emission were illuminated to the specimens from 15cm above. The extracted $2{\mu}l$ of sample was plated on nutrient agar plate ($Bacto^{TM}$ Brain Heart Infusion; BD, USA) with 10 minute intervals for 120 minute, respectively. It was incubated for 24 hours at $37^{\circ}C$ and the colony forming units (CFUs) were then counted. Results. Compared the characteristics of LT photocatalyst with commercial P-25 photocatalyst, LT were shown higher activity than P-25. The LT coated experimental specimen surface had anatase crystal form, less than 20 nm of particle size and wide specific surface area. To evaluate the photocatalytic activity of specimens, methylene blue degradation reaction were used and about 5% of degradation rate were measured after 2 hours. The average contact angle was less than $20^{\circ}$ indicating that the LT photocatalyst had hydrophilicity. In the antifungal activity test for Candida albicans, 0% survival rate were measured within 30 minute after irradiation of UVA light. Conclusion. From the results reported above, it is concluded that the UVA-LT photocatalytic reaction have an antifungal effect on the denture surface Candida albicans, and so that could be applicable to the clinical use as a cleaning method.

측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향 (EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES)

  • 서덕규;민선홍;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제34권2호
    • /
    • pp.145-153
    • /
    • 2009
  • 본 연구에서는 측정장치의 compliance유무가 복합레진의 중합수축응력 측정에 미치는 영향을 알아보았다. 변위센서, cantilever load cell과 부궤환 (negative feedback) 시스템을 적용하여 compliance를 허용하는 것과 허용하지 않는 두 가지 모드로 중합수축응력의 측정이 가능한 stress-strain analyzer를 제작하였다. 한 종의 flowable (Filtek Flow: FF) 복합레진과 두 종의 universal hybrid (Z100: Z1 and Z250: Z2) 복합레진이 사용되었다. Load cell의 끝과 base plate에 고정된 직경 3.0 mm의 금속 막대에 silane을 처리하였다. 1.0 mm의 거리로 고정한 두 개의 금속 막대 사이 에 복합레진을 적용한 후 광중합을 하였다. 복합레진의 수직 중합수축률과 중합수축응력을 10 분 동안 기록하였고 인장탄성계수도 구하였다. 통계처리는 일원분산분석과 paired t-test를 시행하였고 95% 유의수준에서 Tukey's test로 사후 검정하였다. 측정된 중합수축 응력은 재료와 compliance의 유무에 따라 큰 차이를 보였다. Compliance를 허용한 모드에서 중합수축응력은 FF: 3.11 (0.13)이 가장 컸으며 Z1: 2.91 (0.10), Z2: 1.94 (0.09) Mpa의 순서였다. 측정장치의 compliance를 허용하지 않은 경우에는 Z1 17.08 (0.89)이 가장 컸고 FF: 10.11 (0.29), Z2: 9.46 (1.63) MPa의 순이었다. 또한 Z1, Z2, FF의 인장탄성계수는 각각 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa 이었다. 중합수축응력은 compliance mode에서는 복합레진의 수직 중합수축률이 주요 영향 요인이었으며, compliance를 배제한 모드에서는 탄성계수의 효과가 지배적이었다.

Polyetherketoneketone의 연마 특성이 Candida albicans의 부착에 미치는 영향 (Polishing characteristics of polyetherketoneketone on Candida albicans adhesion)

  • 김현영;이종혁;이성훈;백동헌
    • 대한치과보철학회지
    • /
    • 제58권3호
    • /
    • pp.207-216
    • /
    • 2020
  • 목적: 최근 치과에 도입된 polyetherketoneketone (PEKK)의 연마 특성이 Candida albicans의 부착에 미치는 영향을 기존 의치상재료인 polymethylmethacrylate (PMMA)와 비교하고자 하였다. 재료 및 방법: PEKK(그룹 E)와 PMMA(그룹 M)를 사용하여 직경 8 mm, 두께 2 mm인 원판 형태 시편을 제작한 후 연마 정도에 따라 각각 2개 그룹으로 세분하였다(ER, MR: rough; EP, MP: polished, 각 그룹당 시편 12개). 연마는 SiC 연마지로 시행하였으며, ER과 MR 그룹에서는 600 grit SiC 연마지만으로, EP와 MP 그룹에서는 600, 800, 1,000, 1,200 grit SiC 연마지로 단계적으로 연마하였다. 표면의 평균 거칠기는 원자력간 현미경(AFM)을 사용하여 Sa값을 측정하였고 주사전자 현미경으로 1,000배와 20,000배 확대하여 표면을 관찰하였다. 24-well 세포배양 용기에 연마된 시편 및 C. albicans 현탁액을 넣고 37℃에서 2시간 동안 배양하여 C. albicans의 부착을 유도하였으며, 부착된 진균을 피펫팅을 통해 분리하고 현탁액을 10 배씩 단계적으로 103 배까지 희석한 후, Sabouraud dextrose 고체배지에 스프레더를 이용하여 접종하였다. 48시간 후 각 고체배지에 형성된 집락의 개수(CFU/plate)를 세어 기록하였다. 측정된 값들의 통계적 차이를 확인하기 위해 one-way ANOVA와 Tukey HSD test를 수행하고 유의수준을 0.05로 정하였다. 결과: 평균 Sa 값은 MR 그룹이 다른 그룹에 비해 유의하게 더 높게 나타나 단계적 연마지 연마법은 PMMA 시편에서만 유의한 효과가 있었음을 확인할 수 있었다 (P < .05). MP 그룹과 EP 그룹간에 Sa 값은 유의한 차이가 없었다. 주사전자현미경 관찰결과 PEKK 시편들의 표면에서 다수의 보풀 같은 돌기가 형성되어 있는 것을 볼 수 있었고 EP 그룹에서 더 심해진 것을 관찰할 수 있었다. CFU/plate의 평균값은 EP 그룹에서 가장 높게 나왔으며 가장 낮은 MP 그룹과 유의한 차이를 보였다 (P < .05). 결론: PMMA와 비교하여 PEKK에서는 단계적 연마지를 이용한 연마를 시행 시 C. albicans의 부착 증가로 이어질 수 있으며, 임상에서도 이러한 점에 대한 신중한 고려가 필요할 것으로 사료된다.

AZ61 마그네슘 합금 마찰교반용접부의 기계적 특성 평가 및 미세조직 분석 (Evaluation of Mechanical Properties and Analysis of Microstructure of AZ61 Magnesium Alloy Butt Joints by Friction Stir Welding)

  • 선승주;김정석;임재용;이우근;고요한;김영민;유봉선
    • 한국철도학회논문집
    • /
    • 제19권4호
    • /
    • pp.417-426
    • /
    • 2016
  • 본 연구에서는 AZ61 압출 판재 마찰교반용접부의 기계적 강도 평가와 미세조직 평가를 수행하여 최적의 용접조건을 도출하였다. 용접조건은 용접 툴의 회전속도 400, 600, 800rpm, 이송속도 200, 300, 400mm/min으로 선정하였다. 인장시험 및 경도시험을 통해서 용접부의 기계적 강도 평가를 하였으며, 파단면 관찰과 용접부 단면 미세조직 관찰을 통해서 용접부의 결함 유무를 확인하였다. 용접부 특성 평가 결과 본 연구에서 제시한 용접조건 내에서 AZ61 압출 판재의 최적용접조건은 회전속도 800rpm, 이송속도 200mm/min이었고, 용접부의 인장강도, 항복강도 그리고 연신율은 모재 대비 79.0%, 65.4%, 30.1%로 측정되었다.

드럼형 자동공구교환장치의 설계에 관한 연구 (A study on the Design of Drum Type Automatic Tool Changer)

  • 최현진;이한규
    • 한국기계가공학회지
    • /
    • 제19권7호
    • /
    • pp.52-59
    • /
    • 2020
  • Automatic tool changers (ATCs) can be divided into drum and chain types. Drum-type ATCs contain a magazine, where the tools are mounted, and a cam gearbox, which swaps the tools via roller gear and grooved plate cams. Drum-type ATCs are advantageous in that the operating time for the tool magazine is more rapid than that of chain-type ATCs and the length of the unit is shorter. Thus, drum-type ATCs can be fabricated into various shapes and forms depending on the number of tools and the magazine size in accordance with machining center requirements and consumer demand. In particular, the price competitiveness of a machining center with a drum-type ATC is higher, while drum-type ATCs are more rigid with fewer parts, possibly reducing the need for regular servicing. This study aims to verify the structural stability and design validity of the magazine base, which is the main structure of a drum-type ATC, using finite element analysis. This study kinematically verifies the specifications of the selected drive motor and reducer and assessed the design of the cam gearbox. It also conducts a structural analysis of the roller camp, which is the core component of the cam gearbox, based on the results of the kinetodynamic analysis, thus validating the structural design.

Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

  • Nam, Ki-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.207-214
    • /
    • 2014
  • PURPOSE. This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS. Polymerized PMMA denture acrylic disc ($20mm{\times}2mm$) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and $100{\mu}L$ of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at $37^{\circ}C$ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe. RESULTS. PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted. CONCLUSION. This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required.

스털링 엔진에 대한 스크롤 팽창기 : 압축기의 적용성 (Applicability of Scroll Expander-compressor for Stirling Engine)

  • 김성준;김현진;김영민
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.94-102
    • /
    • 2009
  • Conceptual design of scroll expander and scroll compressor for 10kW-class Stirling engine utilizing solar energy as heat source has been carried out to estimate the applicability of scroll mechanism for Stirling cycle. CO2 was chosen as working fluid, since it has lower expansion index and higher density among probably usable gases. Gas temperature at the expander inlet was set at $700^{\circ}C$, and that at the compressor inlet was at $40^{\circ}C$. System efficiency reached maximum at the pressure ratio of about 2.5, and the peak efficiency increased with increasing high side pressure. Due to safety concern, the pressure condition of 6 MPa/2.5 MPa was chosen as design condition. Orbiting scroll members for the expander and compressor were designed to have double-sided structure in order to reduce the overall scroll size and to cancel out the axial gas forces acting on the orbiting scroll base plate. By parametric study on the scroll profile, smaller possible size for the scroll members was obtained. With the shaft speed of 3600rpm, the shaft output of the designed scroll expander was calculated to be 45.4kW, while input power for the scroll compressor was 34.5kW, yielding 10.9kW for the output power of the Stirling engine. System efficiency was estimated to be about 7.3%, and overall efficiencies of the scroll expander and compressor were around 84.1% and 88.3%, respectively.

다공성 TiO2-SiO2 복합 단열재의 열전도율 평가 (Evaluation of Thermal Conductivity of Porous TiO2-SiO2-Base Thermal Insulation)

  • 최병철;김종호;김종범;정우남;이상현
    • 융복합기술연구소 논문집
    • /
    • 제8권1호
    • /
    • pp.21-25
    • /
    • 2018
  • We developed nano-porous $TiO_2-SiO_2$ composites (commercial name : PTI, porous titania insulator) with low thermal conductivity as thermal insulating material as well as function of photocatalyst. The objectives of this paper are, firstly, to evaluate of the thermal conductivity of the PTI powder in the temperature range from -160 to $250^{\circ}C$, secondly to evaluate of thermal conductivities of insulation materials that is applied PTI powder. The structure of the PTI powder that has the pores size of 20-30 nm and the particle diameter of 2-10 nm. The PTI had a high surface area of $400m^2/g$ and a mean pore size of $45{\AA}$, which was fairly uniform. The thermal conductivity was measured by GHP(guarded hot plate) method and HFM(heat flux method). The PTI structure is a three-dimensional network nano-structures composed by a pearl-necklace that involved a precious stone in the center of the necklace. The thermal conductivities of PTI-PX powder by the GHP and HFM were 0.0366 W/m.K, 0.0314 W/m.K at $20^{\circ}C$, respectively. This is similar to values that are proportional to the square of the absolute temperature of the thermal conductivity of static air. The thermal conductivities of insulating sheets coated with PTI powder were similar results with that of the PTI powder.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • 제16권1호
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.