• Title/Summary/Keyword: Base plate

Search Result 614, Processing Time 0.026 seconds

Performance Enhancement of 3-way Doherty Power Amplifier using Gate and Drain bias control (Gate 및 Drain 바이어스 제어를 이용한 3-way Doherty 전력증폭기와 성능개선)

  • Lee, Kwang-Ho;Lee, Suk-Hui;Bang, Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.77-83
    • /
    • 2011
  • In this thesis, 50W Doherty amplifier was designed and implemented for Beyond 3G's repeater and base-station. Auxiliary amplifier of doherty amplifier was implemented by Gate bias control circuit. Though gate bias control circuit solved auxiliary's bias problem, output characteristics of doherty amplifier was limited. To enhance the output characteristic relativize Drain control circuit And To improve power efficiency make 3-way Doherty power amplifier. therefore, 3-way GDCD (Gate and Drain bias Control Doherty) power amplifier is embodied to drain bias circuit for General Doherty power amplifier. The 3-way GDCD power amplifier composed of matching circuit with chip capacitor and micro strip line using FR4 dielectric substance of specific inductive capacity(${\varepsilon}r$) 4.6, dielectric substance height(H) 30 Mills, and 2.68 Mills(2 oz) of copper plate thickness(T). Experiment result satisfied specification of amplifier with gains are 57.03 dB in 2.11 ~ 2.17 GHz, 3GPP frequency band, PEP output is 50.30 dBm, W-CDMA average power is 47.01 dBm, and ACLR characteristics at 5MHz offset frequency band station is -40.45 dBc. Especially, 3-way DCHD power amplifier showed excellence efficiency performance improvement in same ACLR than general doherty power amplifier.

On the Circumorbital Bone of the Cyprinid Fishes in Korea (한국산 잉어과(Cyprinidae) 어류의 안와환부골(眼窩環部骨)에 대하여)

  • Nam, Myung-Mo;Yang, Hong-Jun
    • Korean Journal of Ichthyology
    • /
    • v.10 no.1
    • /
    • pp.128-138
    • /
    • 1998
  • Comparative studies on the morphological characters of the circumorbital bone were made in order to investigate the phylogenetic relationships of the family Cyprinidae. In this paper, forty four species from Korea and three species of Gobiobotia and Saurogobio dabryi from China were studied. Pungtungia herzi, Pseudopungtungia nigra and Pseudopungtungia tenuicorpus were similar in morphological structure on points of the first infraorbital elongated. In Hemibarbus, the base portion of the opened sensor canal was transformed into a lateral plate in the infraorbital. Microphysogobio was characteristic in that the infraorbital series were large, and had close relationship with Pseudogobio esocinus and Saurogobio dabryi. Gobiobotia were reduced to a bony canal with dermal bone. Culter brevicauda had a short supraorbital. Cyprininae were characterized by larger fourth and fifth infraorbitals. Leuciscinae were divided into two groups: Moroco and Zacco. The former includes Phoxinus phoxinus, Moroco oxycephalus and Moroco kumgangensis, and the latter includes Zacco platypus, Zacco temmincki and Opsariichthys bidens. Moroco group was distinguished from Zacco group in points of having a short supraorbital and a elongated the first infraorbital.

  • PDF

Classification and Characterization of Bacteriophages of Lectobacillus casei (Lactobacillus casei Bacperiophage의 분류 및 특성에 관한 연구)

  • 김영창;박민철;강국희;윤영호;이광웅
    • Korean Journal of Microbiology
    • /
    • v.17 no.4
    • /
    • pp.165-178
    • /
    • 1979
  • Phages of Lactobaciilus casei (PLC) isolated from plant drainage were classified and characterized. The results are as follows : 1. On the basis of host range pattern, phages could be divided into 2 groups (PLC-B and PLC-C). PLC-B group phages could be further divided into 5 sub-groups $(B_1, \;B_2, \;B_3, \;B_4, \;and\;B_5)$. Although PLC-C group phages had the same host range, they could be also divided into 2 sub-groups $(C_1\;and\;C_2)$ by morphlogical type. 2. It was $B_3$ group phages that represented a major proportion (44.4%) of phages tested. However, $B_1$ group phages were shown to have the widest host range. 3. Electron micrographs revealed that the phages fell into three different morphological types. $(B_1, \;B_2, \;and\;B_3)$ group phages hd a hexagonal head (52nm in diameter) and a sheathless noncontractile (245 nm in length). $B_4\;and\;C_2$ group phages had a hexagonal head (56 nm) and a short flexible tail (169nm) having no sheath. $B_5\;and\;C_1$ group phages were shown to have a hexagonal head (81 nm) and a contractile tail (140 nm) having a sheath, a base plate and tail fibers. 4. The inactivation of the phages by antisera indicated that serological relationships correlated completely with morphological types. 5. $B_1, \;C_1\;and\;C_2$ group phages produced a large (1, 2 mm in diameter) plaque with a clear ring. The morphology of plaques of $B_3\;and\;B_5$ group phages was the same as those produced by the above, but the average plaque sizes for $B_3\;and\;B_5$ were 0.8 mm abd 0.5 mm, respectively. $B_2\;and\;B_4$ group phages produced a small (0.5 mm) turbid plaque with an irregular edge. 6. The latent period and the average burst size of $B_1\;and\;B_3$ group phages were 90 min and 100, respectively. These phages reuqired calcium ions for their miltiplication. 7. $B_3$ group phages could not be absrobed to R-variant $KC_1$. 8. The order of resistance of phages to heat was $B_2\;>\;B_1, B_4\;and\;B_5\;>\;B_3\;and\;C_2, \;B_5$ group phages were more stable than $B_3$ in various pH values. $C_2$ group phages were more sensitive to UV irradiation than $B_1\;and\;B_3$ group phages. 9. Strains YIT9018 and IAM 1043 were induced by mitomycin C treatment. Phage particles detected in the lysates had a hexagonal head (38 and 49 nm, respectively), but no tail. Any sensitive indicator strain could not be isolated in spite of repaeated trials.

  • PDF

Study of Spin Jig Development for Cleaning of the PCB component (PCB기판 세척용 스핀 지그개발에 관한 연구)

  • Lee, Seung-Chul;Park, Suk-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4736-4741
    • /
    • 2014
  • This study examined PCB component cleaning on a PCB component surface, which has defects of precipitation type washing (existing rinse method), sealant and foreign material formed in the adhesive process that could not be removed easily. The spin jig was developed for PCB component cleaning, in which the PCB component settled down, to solve the conventional problem of the removal of foreign material with the centrifugal force by high speed rotation. The results are as follows. With decreasing fraction defect in PCB component washing, the development and substrate damage decreased by more than 80% according to the abstergent in the rotary type using the centrifugal force in the existing precipitation type. When the base plate showed a large difference with the time to include the process after washing the design using the existing method, easy attachment and separation of the PCB component could be possible. The washing time was enhanced 90% compared to the existing time. The reliability of the security and washing collaboration of the design and stability of the cleaning process could be secured so that there was no phenomenon of secession, the PCB component fixed for a cleansing rotation jig could maintain a fixed force by the centrifugal force. The stability and reliability of the washing process and the defective rate could be improved to less than 1%.

Sensitivity Analysis of Dynamic Characteristics of Structural Systems by the Transfer Matrix Method and the Combined Finite Element-Transfer Matrix Method (전달매트릭스법 및 유한요소-전달매트릭스 결합방법에 의한 구조계의 동특성 감도해석)

  • D.S. Cho;K.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.1
    • /
    • pp.143-157
    • /
    • 1992
  • For the design of structural systems having the prescribed or optimum dynamic characteristics, some design changes of the initially designed system are required. In these cases, if the sensitivity analysis which can predict the changes of dynamic characteristics due to the changes of design variables is applied, the design changes can be carried out rationally and very efficiently. For many structural systems, it is well known that the analysis by the transfer matrix method(TMM) and the combined finite element-transfer matrix method(FETMM) is more efficient than the analysis by the finite element method. However, most known studies on the sensitivity analysis of structural systems premise using the finite element method. In this paper, the sensitivity analysis methods by the TMM and the FETMM are presented and some numerical investigations on the beam-column with elastically restrained ends and intermediate contraints and the stiffened plate having subsystems are carried out. The results of the numerical examples show good accuracy and computational efficiency of the presented methods, and show that the application of sensitivity analysis in the dynamic characteristic reanalysis give good results within the practically changeable range of design variables.

  • PDF

Functional repair of the cleft lip and palate using Delaire method (Delaire 법을 이용한 구순구개열 환자의 구순 및 코 교정수술)

  • Song, In-Seok;Yi, Ho;Lee, Su-Yeon;Lee, Il-Gu;Myoung, Hoon;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin;Seo, Byoung-Moo
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.9 no.2
    • /
    • pp.93-100
    • /
    • 2006
  • Although the delayed type of rhinoplasty is currently acceptable in the correction of cleft lip and nasal deformity, Delaire tried to achieve the simultaneous nasolabial reconstruction and muscular rearrangement that affect the subsequent skeletal growth of the face. the anatomic muscular reconstruction can be achieved by making the anchorage of the nasolabial muscles of the cleft side to the nasal septum and muscles on the non-cleft side. Two cleft lip patients of 6 and 7 year-old without any previous operation history were treated with the functional cheilorhinoplasty. One patient with incomplete cleft lip underwent a cheiloplasty along with the rearrangement of orbicularis oris muscle. The other patient had a complete cleft lip and palate with accompanying nasal deformity, who underwent the functional cheilorhinoplasty with the reconstruction of anterior nasal base. All the operation was done under the general anesthesia and patients healed without any significant complications. In the incomplete case, the shapes of Cupid's bow was restored, and the length of columella was regained comparable to the non-affected side. In the complete cleft lip and palate case, the depressed nostril was reconstructed with acceptable symmetry by complete releasing of deformed alar cartilage undermined with a dissecting scissors. In summary, the functional repair of cleft lip and nose could be possible at the same time by using Delaire method. This method is effective to correct the primary nasolabial deformity, which results in the restoring favorable anatomy and its function.

  • PDF

A study on monitoring for process time and process properties by measuring vibration signals transmitted to the mold during injection molding (사출성형공정에서 금형에 전달되는 진동 신호 측정을 이용한 성형 단계별 공정시간과 공정특성의 모니터링에 대한 연구)

  • Lee, Jun-han;Kim, Jong-Sun
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.8-16
    • /
    • 2020
  • In this study, the vibration signal of the mold was measured and analyzed to monitoring the process time and characteristics during injection molding. A 5 inch light guide plate mold was used to injection molding and the vibration signal was measured by MPU6050 acceleration sensor module attached the surface of fixed mold base. Conditions except for injection speed and packing pressure were set to the same value and the change of the vibration signal of the mold according to injection speed and packing pressure was analyzed. As a result, the vibration signal had a large change at three points: "Injection start", "V/P switchover", and "Packing end". The time difference between "injection start" and "V/P switchover" means the injection time in the injection molding process, and the time difference between "V/P switchover" and "Packing end" means the packing time. When the injection time and packing time obtained from the vibration signal of the mold are compared with the time recorded in the injection molding machine, the error of the injection time was 2.19±0.69% and the error of the packing time was 1.39±0.83%, which was the same level as the actual value. Additionally, the amplitude at the time of "injection start" increased as the injection speed increased. In "V/P switchover", the amplitude tended to be proportional to the pressure difference between the maximum injection pressure and the packing pressure and the amplitude at the "packing end" tended to the pressure difference between the packing pressure and the back pressure. Therefore, based on the result of this study, the injection time and packing time of each cycle can be monitored by measuring the vibration signal of the mold. Also, it was confirmed that the level and trend of process variables such as the injection speed, maximum injection pressure, and packing pressure can be evaluated as the change of the mold vibration during injection molding.

THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS (치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 -)

  • Lee Yong-Keun;Lee Keon-Il;Jung Sung-Woo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

A Study of Facial Deformity in the Patient with Bilateral Cleft Lip before the Primary Cheiolplasty (양측성 구순열 환자의 안모 변형에 대한 연구)

  • Yoon Bo-Keun;Soh Byung-Soo;Baik Jin-Ah;Shin Hyo-Keun
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.4 no.2
    • /
    • pp.51-68
    • /
    • 2001
  • Midfacial hypoplasia in patients with clefts of the lip and palate is considered to be the result of congenital dysmorphogenesis. And cleft lip and palate developes facial deformity, jaw abnormality, speech problem, which is most frequent hereditary deformity in maxillofacial region. So cleft lip and palate is characterized by midface deformity which shaws maxillary anterior nasal septal deviation and deformity. Our study describes congenital correlates of midfacial hypoplasia by examining the displacement of a normal complement of parts, a triangular tissue deficiency low on the lip border on the columellar side, and a linear deficiency and displacement in the line of the bilateral cleft lip. 15 patients with bilateral cleft lip and palate were taken impression before operation, but the patient who had other abnormalities and complications were excluded. Average age is 3.4 months and they were classified into both complete, both incomplete and complete & incomplete group. The obtained results were as follows 1. There were no differences on intercanthal width and canthal width between each of the groups. 2. Both complete group had longer lateral ala length than both incomplete group, but there were no differences between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 3. Columella length was greater in both incomplete group than in both complete group, but there was no difference between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 4. Both complete group had longer ala width & ala base width than both incomplete group had. But there were no differences between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 5. There were no differences between each of the groups on upper lip length, but nose/mouth width ratio was greater in both complete group than in both incomplete group. 6. Pronasale(pm), subnasle(sn), la~rale superioris(ls), stomion(sto) points were located around the central vertical line of face but deviated to incomplete side in com. & incom. group. 7. Nasal tip protrusion was greater in both incomplete group and com. & incom. group than both complete group, but there was no difference between both incomplete group and com. & incom. group.

  • PDF

Weldability with Process Parameters During Fiber Laser Welding of a Titanium Plate (I) - Effect of Type and Flow Rate of Shielding Gases on Weldability - (티타늄 판재의 파이버 레이저 용접시 공정변수에 따른 용접특성 (I) - 실드가스 종류 및 유량에 따른 영향 -)

  • Kim, Jong Do;Kim, Ji Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1047-1053
    • /
    • 2016
  • In this study, welding of pure titanium was carried out by using a continuous wave fiber laser with a maximum output of 6.3 kW. Because brittle regions form easily in titanium as a result of oxidation or nitriding, the weld must be protected from the atmosphere by using an appropriate shielding gas. Experiments were performed by changing the type and the flow rate of shielding gases to obtain the optimal shielding condition, and the weldability was then evaluated. The degree of oxidation and nitriding was distinguished by observing the color of beads, and weld microstructure was observed by using an optical microscope and a scanning electron microscope. The mechanical properties of the weld were examined by measuring hardness. When the weld was oxidized or nitrified, the bead color was gray or yellow, and the oxygen or nitrogen content in the bead surface and overall weld tended to be high, as a result of which the hardness of the weld was thrice that of the base metal. A sound silvery white bead was obtained by using Ar as the shielding gas.