• 제목/요약/키워드: Base plate

검색결과 614건 처리시간 0.025초

A new base plate system using deformed reinforcing bars for concrete filled tubular column

  • Park, Yong-Myung;Hwang, Won-Sup;Yoon, Tae-Yang;Hwang, Min-Oh
    • Steel and Composite Structures
    • /
    • 제5권5호
    • /
    • pp.375-394
    • /
    • 2005
  • An experimental study was conducted to develop a new base plate anchorage system for concrete filled tubular column under an axial load and a moment. The column was connected to a concrete foundation using ordinary deformed reinforcing bars that are installed at the inside and outside of the column. In order to investigate the moment resisting capacity of the system, horizontal cyclic loads are applied until the ultimate condition is reached with the axial load held constant. To derive a design method for moment resisting capacity, the reinforced concrete section approach was investigated with the assumption of strain compatibility. The results by this approach agreeded well with those of experiments when the bearing pressure of confined concrete and tangent modulus of steel bars are assumed appropriately. Also, it was found that the column interaction curve can be used to predict the yield strength of the base plate system.

휨을 받는 고장력볼트 체결부에서 과대공에 따른 사용성에 관한 연구 (A Study on Serviceability of Oversized Bolt Hole in High-Tension Bolt Joint Subjected to Bending)

  • 박정웅;양승현;장석인
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2831-2836
    • /
    • 2009
  • 고장력볼트를 이용한 강부재의 연결부에서 마찰력을 초과하는 설계하중이 작용하여 미끄럼이 발생하는 점을 기점으로 볼트와 모재의 전단강도 및 지압강도에 의해 설계하중을 지지하게 된다. 미끄럼량은 볼트의 장력, 접촉면의 마찰계수, 모재구멍내에서 볼트의 위치에 따라 결정되어 질 수 있다. 본 연구에서는 모재 및 덮개판에 대하여 볼트구멍의 크기를 변화시켜 제작된 고장력볼트 체결부에 순수굽힘과 인장력이 작용하는 경우 표준공과 과대공에 따른 미끄럼을 측정하고 비교분석하였다. 표준공을 가지는 경우보다 과대공을 가지는 경우에 $74\sim94%$ 작은 하중에서 미끄럼이 발생하였다. 인장력을 받는 부재에서는 과대공치수가 클수록 미끄럼 하중비가 작게 나타났으며 모재의 과대공치수가 덮개판의 과대공치수보다 미끄럼하중변화와 연관성이 많은 것으로 나타났다.

Al-Si계 필러메탈을 이용한 A1050알루미늄의 브레이징 접합조건에 관한 연구 (A Study on the Brazing Bondinf Conditions of A1050 Using Al-Si Alloy Filler Metal)

  • 김정일;김영식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권1호
    • /
    • pp.66-72
    • /
    • 1993
  • The brazing of Al to Al using Al-Si alloy filler metal was performed under different bonding conditions such as ratio of lap length to plate thickness, surface roughness and joint clearance of the lap joint. The adopted thickness of the base metal in this experiments were two kinds of 4mm and 7mm which were most commonly used in various field. Influence of several bonding conditions of Al/Al joint was quantitavely evaluated by bonding strength test, and microstructural analysis at the interlayer were performed by optical microscope. From above experiments, the optimum bonding conditions of the brazing bonding of Al/Al using Al-Si alloy filler metal was determined. The major results obtained are as follows. 1) The fracture occurs at brazed joint in the conditions of that the ratio of lap length to plate thickness is less than 2 in case of 7mm plate thickness. 2) The ratio of lap length to plate thickness which the fracture occurs at base metal is decreased with the decreasing of the plate thickness. 3) The joint strength is not affected by the surface roughness and joint clearance of the brazed part. 4) The heat-treatment of the brazed joint contribute to eliminate the boundary between the base metal and filler metal. However, the joint strength is not affected by the heat-treatment.

  • PDF

연강 판재의 맞대기 용접에서 아크에 작용하는 자기력의 해석 (Analysis of Electro-Magnetic Force Acting on Arc Column in Butt-Joint Welding of Mild Steel Plate)

  • 배강열
    • Journal of Welding and Joining
    • /
    • 제23권4호
    • /
    • pp.73-80
    • /
    • 2005
  • Arc blow being occurred by Electro-Magnetic force(EMF) during the electric arc welding prevents the formation of a sound weldment. In this study, the effects of arc position, groove size, tack weld and base plate on the EMF in a butt-joint welding of mild steel plate are analyzed by a computer simulation based on the finite element method. The EMF can be numerically identified to be caused by a difference of the magnetic flux-density between ahead of and behind the arc in case that the workpiece locates asymmetrically around the uc. When there exists an air gap of groove ahead of the arc in the welding direction, the similar magnetic force has been producted regardless of the arc position and the gap size. The tack weld alleviates the magnetic force to about one fourth at the finish end of the workpiece. The magnetic force can be also significantly reduced with the base plate to about one fifth at the start end of the workpiece containing a tack weld.

Parametric Studies for the Optimum Design of a Hexagonal Plate Monopole Antenna

  • Park Seong-Bae;Park Joung-Min;Ahn Bierng-Chearl;Kim Kyung-Seok
    • Journal of electromagnetic engineering and science
    • /
    • 제6권1호
    • /
    • pp.53-61
    • /
    • 2006
  • In this paper, we present parametric studies for the optimum design of a hexagonal plate monopole antenna. The dependence of the antenna performance on various geometric parameters is investigated using a commercial electromagnetic software, from which an optimum design of a hexagonal plate monopole antenna is derived. Guidelines for determining initial parameter values are given. The diameter of the circular ground plane is minimized tlo 1/5 wavelength at the lowest operating frequency. The antenna impedance matching is controlled by adjusting the gap between the plate and the ground plane, the plate base width, and the base bevel angle. The antenna proposed in. this paper shows a reflection coefficient less than -10 dB and a $2.0{\sim}6.2$ dBi gain over $3{\sim}20$ GHz frequencies.

PZT 계 압전세라믹스의 전기 및 음향특성에 관한 연구 (a study on the Electrical and acoustical properties of PZT ceramic.)

  • 김소정;김호기;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.333-334
    • /
    • 1989
  • Electrically active part of the piezoelectric sound element is a ceramic thin circular disk cemented to a metal base plate (using a type of thermosetting epoxy). The active part is a thin lead zirconate titanate disk (PZT). The piezoelectric sound element is so dimensioned that its basic resonance frequency is approximately if the center of the audible frequency band: This frequency is mainly determined by the geometry and the sort of the metal base plate materials. In this study, four kinds of PZT ceramic and two classes of thin metal base plate were prepared. It is observed that dielectric and pizoelectric properties relate to acoustical properties (particularly sound pressure level).

  • PDF

Strength degradation of reinforced concrete piers wrapped with steel plates under local corrosion

  • Gao, Shengbin;Ni, Jie;Zhang, Daxu;Ge, Hanbin
    • Steel and Composite Structures
    • /
    • 제24권6호
    • /
    • pp.753-765
    • /
    • 2017
  • This paper aims to investigate the strength degradation of reinforced concrete piers wrapped with steel plates which corrode at the pier base by employing a three dimensional elasto-plastic finite element formulation. The prediction accuracy of the employed finite element analysis method is firstly verified by comparing the analytical results with test results. Then, a series of parametric studies is carried out to investigate the effects of steel plate's corrosion position along width direction, corrosion depth along plate thickness, corrosion range along width direction, and steel plate-concrete bonding degradation on the strength of the piers. It is observed that the strength degradation of the piers is closely related to steel plate's corrosion position, corrosion depth and corrosion range in the case of local corrosion on the webs. In contrast, when the base of flanges corrodes, the strength degradation of the piers is only related to steel plate's corrosion depth and corrosion range, and the influence of corrosion position on the strength degradation is very gentle. Furthermore, the strength of the piers decreases with the degradation of steel plate-concrete bonding behavior. Finally, the maximum strength of the piers obtained from numerical analysis corresponding to different bonding behavior is compared with theoretical results within an accepted error.

힘/모멘트 측정기능을 갖는 6축 로봇 베이스 플랫폼 개발 (Development of a 6-axis Robotic Base Platform with Force/Moment Sensing)

  • 정성훈;김한성
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.315-324
    • /
    • 2019
  • This paper present a novel 6-axis robotic base platform with force/moment sensing. The robotic base platform is made up of six loadcells connecting the moving plate to the fixed plate by spherical joints at the both ends of loadcells. The statics relation is derived, the robotic base platform prototype and the loadcell measurement system are developed. The force/moment calibrations in joint and Cartesian spaces are performed. The algorithm to detect external force applied at a working robot is derived, and using a 6-DOF robot mounted on the robotic base platform, force/moment measurement experiments have been performed.

The Pumping Characteristics of the Valveless Peristaltic Micropump by the Variation of Design Parameters

  • Chang, In-Bae;Park, Dae-Seob;Kim, Byeng-Hee;Kim, Heon-Young
    • KSTLE International Journal
    • /
    • 제3권2호
    • /
    • pp.101-109
    • /
    • 2002
  • This paper presents the fabrication and performance inspection of a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of base plate, mid plate, top plate and connection tubes fur inlet and outlet. In detail, the base plate is composed of two diffuser nozzles and three chambers, the mid plate consists of a glass diaphragm for the volumetric change of the pumping chamber. The inlet and outlet tubes are connected at the top plate and the actuator fur pressing the diaphragm is located beneath the top plate. The micropump is fabricated on the silicon wafer by DRIE (Deep Reactive ion Etching) process. The pumping performances are tested by the pneumatic test rig and compared with the simulated results fur various dimensions of diffuser nozzles. The pumping characteristics of the micropump by the volumetric change at the pumping chamber is modeled and simulated by the commercial software of FLOW-3D. The simulated results shows that reverse flow is the inherent phenomena in the diffuser nozzle type micropump, but it can be reduced at the dual pumping chamber model.

다방향 접합철물 삽입형 기둥-기초 접합부 모멘트 저항성능평가 (Evaluation of Moment Resisting Post-Base Connection Using Multi-directional Connector)

  • 김건호;이상준
    • 한국가구학회지
    • /
    • 제25권4호
    • /
    • pp.331-337
    • /
    • 2014
  • The purpose of this paper is to evaluate the moment resistance of glulam post-to-base connections by applying quasi-static cyclic loads. The connectors consisted of inserted plates and drifted pins according to the load direction. The connection types employed in this study were total three including two unidirectional types (H, V) and the multi-directional type (M). The moment resistance of 8 mm-plate M-type is compared to 6 mm plate. Total four types of Post-to-base connection are prepared and tested under pseudo-static reversed cyclic loading. Test results showed that the yield moment of multi-directional connection is about 2 times higher than that uni-directional connections. The ductility ratio of multi-directional connection determined by EEEP was higher that that of uni-directional connection. It was becoming higher as the thickness of plate is increased. The Finite Element Analysis was conducted to estimate the stress distribution behavior of tested connections. Results showed the failure of multi-directional type were caused by the split of pined hole and the shear failure of lifted part of post.

  • PDF