• Title/Summary/Keyword: Base Isolation Bearing

Search Result 115, Processing Time 0.025 seconds

전동-발전기의 방진 마운트에 기인한 공진현상 및 동특성 규명 (Dynamic characteristic for vibration mount of MG-Set)

  • 유무상;오경환;주인국;김효진;노철우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.816-821
    • /
    • 2013
  • This case study presents a practical method to reduce resonant vibration of generator-motor set. The generator is driven at 1800rpm by induction integral motor. The vibration is below alarm limits, but the dominant frequency of vibration is sub-synchronous and close to that of bearing fault signal in spite of new bearings. To find an mechanism of abnormal vibration, ODS and Modal analysis is carried out. The measured modal characteristics were compared with those of FE Analysis. The ODS mode at rated speed is consistent with system natural frequency mode that is excited by bearings. To reduce vibration level, the isolation mount at system base is changed with new rubber mount for lower natural frequency.

  • PDF

Depiction of concrete structures with seismic separation under faraway fault earthquakes

  • Luo, Liang;Nguyen, Hoang;Alabduljabbar, Hisham;Alaskar, Abdulaziz;Alrshoudi, Fahed;Alyousef, Rayed;Nguyen, Viet-Duc;Dang, Hoang-Minh
    • Advances in concrete construction
    • /
    • 제9권1호
    • /
    • pp.71-82
    • /
    • 2020
  • One of the most suitable methods in structural design is seismic separator. Lead-Rubber Bearing (LRB) is one of the most well-known separation systems which can be used in different types of structures. This system mitigates the earthquake acceleration prior to transferring to the structure efficiently. However, the performance of this system in concrete structures with different heights have not been evaluated thoroughly yet. This paper aims to evaluate the performance of LRB separation system in concrete structures with different heights. For this purpose, three, 16, and 23 story concrete structures are equipped by LRB and exposed to a far-field earthquake. Next, a time history analysis is conducted on each of the structures. Finally, the performance of the concrete structures is compared with each other in the term of their response to the earthquakes and the formation of plastic hinges. The results of the paper show that the rate of change in acceleration response and the ratio of drift along the height of 8 and 23 stories concrete structures are more than those of the 16-stories, and the use of LRB reduces the formation of plastic joints.

Isolation and Characterization of PERV-C env from Domestic Pig in Korea

  • Park, Sung-Han;Bae, Eun-Hye;Park, Sang-Min;Park, Jin-Woo;Lim, Mi-Suk;Jung, Yong-Tae
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권10호
    • /
    • pp.1735-1740
    • /
    • 2008
  • Clone PERV-C (A3) env was isolated from the genomic DNA of domestic pig (Sus scrofa domesticus) in Korea to investigate the molecular properties of PERV-C. The nucleic acid homologies between the PERV-MSL (type C) reference and the PERV-C(A3) clone was 99% for env, but a single base pair deletion was found in the transmembrane (TM) region of the env open reading frame. To examine the functional characteristics of truncated PERV-C env, we constructed a replication-incompetent retroviral vector by replacing the env gene of the pCL-Eco retrovirus vector with PERV-C env. A retroviral vector bearing PERV-C/A chimeric envelopes was also created to complement the TM defect. Our results indicated that truncated PERV-C env was not infectious in human cells as expected. Interestingly, however, the vector with the PERV-C/A envelope was able to infect 293 cells. This observation suggests that recombination within PERV-C TM could render PERV-C infectious in humans. To further characterize PERV-C/A envelopes, we constructed an infectious molecular clone by using a PCR-based technique. This infectious molecular clone will be useful to examine more specific regions that are critical for human cell tropism.

납고무받침의 비선형성을 고려한 벤치마크 사장교의 복합제어 (Hybrid Control of a Benchmark Cable-Stayed Bridge Considering Nonlinearity of a Lead Rubber Bearing)

  • Park, Kyu-Sik;Jung, Hyun-Jo;Lee, In-Won
    • 한국지진공학회논문집
    • /
    • 제6권4호
    • /
    • pp.51-63
    • /
    • 2002
  • 본 논문에서는 지진하중을 받는 사장교의 진동제어 기법 개발을 위해 제공된 벤치마크 사장교에 복합제어 기법을 적용하였다. 이 벤치마크 문제는 2003년 완공 예정으로 미국 Missouri 주에 건설중인 Cape Girardeau 교를 대상 구조물로 고려하였다. Cape Girardeau 교는 New Madrid 지진구역에 위치하고 Mississippi 강을 횡단하는 주요 교량이라는 점 때문에 설계 단계에서부터 내진 문제를 중요하게 고려하였다. 벤치마크 문제에는 사장교의 상세한 설계도면에 기초해 교량의 복잡한 거동을 나타낼 수 있는 3자원 선형모델과 각 제어기법의 성능을 평가하기 위한 18개의 평가기준이 제시되어 있다. 본 연구에서 적용한 복합제어 기법은 지진하중으로 인해 구조물에 발생되는 하중을 줄이기 위한 수동제어 기법과 상판변위와 같은 구조물의 응답을 추가적으로 제어하기 위한 능동제어 기법이 결합된 제어 방법이다. 수동제어 장지로는 납고무받침을 사용하였고 Bouc-Wen 모델을 사용하여 비선형 거동을 고려 할 수 있도륵 모델링 하였다. 능동제어 장치로는 이상적인 hydraulic actuators 가 사용되었으며 제어 알고리듬은 $H_2$/LQG 를 적용하였다. 수치해석 결과 제안방법의 성능은 수동제어 방법에 비해 매우 효과적이며, 능동제어 방법에 비해서는 약간 좋은 제어성능을 나타내었다. 복합제어 방법은 수동제어 부분 때문에 능동제어 방법에 비해 보다 신뢰할 수 있는 제어 방법이다. 따라서 제안된 제어방법은 지진하중을 받는 사장교의 제어를 위해 효과적으로 사용될 수 있다.

지진격리장치를 적용한 복층구조파이핑 시스템의 내진성능평가 (Seismic Performance Evaluation of Multi-Story Piping Systems using Triple Friction Pendulum Bearing)

  • 류용희;주부석;손호영
    • 한국재난정보학회 논문집
    • /
    • 제14권4호
    • /
    • pp.450-457
    • /
    • 2018
  • 연구목적: 2016년 9월 경주 이후 구조물 및 비구조물의 지진 안전성 및 내진성능에 관한 문제가 이슈화 되고 있으며, 특히 배관 시스템의 경우 구조요소 보다 지진 발생시 내진성능에 있어서 취약하다고 볼 수 있다. 스프링클러 배관 시스템과 같은 비구조적 구성요소의 손상으로 인해 지진 발생 및 이후에 상당한 경제적 손실이나 생명 손실을 초래 할 수 있다. 연구방법: 본 연구는 Triple Friction Pendulum Bearings (TPBs)을 설치한 건물 배관 시스템을 이용한 소방 배관 시스템의 내진성능평가를 제시한다. Kobe, Kocaeli, GyeongJu 지진을 고려하여 지반 운동의 불확실성을 고려하였다. 연구결과: 빌딩 시스템과 파이핑 시스템의 첫 번째 모드는 각각 약 5.8Hz와 약 2.742Hz로 나타났으며, 또한 TPBs 시스템이 적용된 배관 시스템의 최대 변위는 Kobe, Kocaeli 및 GyeongJu 지진의 경우 각각 49%, 14.4%, 21.5%가 감소한 것으로 나타났다. 결론: 따라서 건물 배관 시스템에서 지진 격리 시스템을 사용하면 지진이 심할 때 TPB가 없는 일반적으로 설치된 걸물 배관 시스템보다 지진 위험을 줄일 수 있다.