• 제목/요약/키워드: Base Fluid

검색결과 420건 처리시간 0.025초

경남(慶南) 함안(咸安)-군북지역(郡北地域)의 동광화작용(銅鑛化作用)에 관(關)한 연구(硏究) (Copper Mineralization at Haman-Gunbuk Mining District, Kyeongnam Area)

  • 박희인;최석원;장호완;채동현
    • 자원환경지질
    • /
    • 제18권2호
    • /
    • pp.107-124
    • /
    • 1985
  • More than fifty copper veins are emplaced around late Cretaceous granitoid stock in Haman-Gunbuk district, southernmost part of Korea. These veins cut both late Cretaceous granitoids and hornfels of Jindong formation which is intruded by the granitoids. The paragenesis of veins is nearly the same, consisting of (1) an early vein stage in which most iron oxide minerals, tourmaline and other silitcate minerals were deposited, (2) a calcite and quartz with base·metal sulfide stage and (3) late vein lets of barren calcite stage. Fluid inclusion studies reveal highly systematic trends of salinity and temperature during mineralization. Ore fluids of early vein stage were complex NaCl-KCl rich brines. Salinities of polyphase inclusions in quartz and scapolite in thie stage reached up to 72 wt.% and gradually decreased to 10.5wt. % in closing stage. Homogenization temperatures of inclusions in the beginning of this stage were up to $490^{\circ}C$ and then declined steadly to $290^{\circ}C$ in the late stage. Salinities of fluid inclusions in quartz and calcite of base·metal sulfide stage were 37.4~5.7wt. % and homogenization temperatures range from $373^{\circ}C$ to $170^{\circ}C$. Intermittent boiling of early vein fluid is indicated by fluid inclusions in quartz. Potassic alteration of granodiorite adjacent to early vein seems to be related to early saline vein fluid. Fluid inclusion data of base-metal sulfide stage of this area reveal nearly the same range as those of Koseong copper mining district about 30km apart from this area.

  • PDF

이중관 내부 나노유체의 강제대류에 관한 수치적 연구 (Numerical Study of Forced Convection Nanofluid in Double Pipe)

  • 임윤승;최훈기
    • 융합정보논문지
    • /
    • 제9권12호
    • /
    • pp.147-156
    • /
    • 2019
  • 동심 이중관에서 기본유체 물과 나노입자 산화알미늄의 혼합인 나노유체를 적용한 대향유동을 유한체적법의 수치적 방법으로 열전달 특성을 규명하였다. 고온유체는 내부 원형관으로 흐르며 열을 외부 환형관으로 흐르는 저온유체로 전달한다. 고온유체와 저온유체의 체적유량 및 나노입자의 체적농도를 변수로 두어 열전달 및 유동 특성을 조사했다. 결과는 나노입자의 체적농도와 체적유량의 증가함에 따라 열전달 성능이 증가함을 보였다. 외부와 내부 관 모두에서 나노유체인 경우가 기본유체보다 나노입자의 체적농도가 8%일 때 나노유체가 열전달 성능이 최대 17% 증가하는 것을 확인했다. 또한 기본유체에 비해 환형관의 대류열전달 계수는 최대 31% 증가함을 보였으며 열교환기의 유용도는 약 20%가 상승함을 확인하였다. 하지만 나노입자의 체적농도가 8%일때 마찰인자가 최대 136% 커지는 것을 확인하였다.

Multi-Layer Onlay Graft Using Hydroxyapatite Cement Placement without Cerebrospinal Fluid Diversion for Endoscopic Skull Base Reconstruction

  • Kim, Young-Hoon;Kang, Ho;Dho, Yun-Sik;Hwang, Kihwan;Joo, Jin-Deok;Kim, Yong Hwy
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권4호
    • /
    • pp.619-630
    • /
    • 2021
  • Objective : The skull base reconstruction step, which prevents cerebrospinal fluid (CSF) leakage, is one of the most challenging steps in endoscopic skull base surgery (ESS). The purpose of this study was to assess the outcomes and complications of a reconstruction technique for immediate CSF leakage repair using multiple onlay grafts following ESS. Methods : A total of 230 consecutive patients who underwent skull base reconstruction using multiple onlay grafts with fibrin sealant patch (FSP), hydroxyapatite cement (HAC), and pedicled nasoseptal flap (PNF) for high-flow CSF leakage following ESS at three institutions were enrolled. We retrospectively reviewed the medical and radiological records to analyze the preoperative features and postoperative results. Results : The diagnoses included craniopharyngioma (46.8%), meningioma (34.0%), pituitary adenoma (5.3%), chordoma (1.6%), Rathke's cleft cyst (1.1%) and others (n=21, 11.2%). The trans-planum/tuberculum approach (94.3%) was the most commonly adapted surgical method, followed by the trans-sellar and transclival approaches. The third ventricle was opened in 78 patients (41.5%). Lumbar CSF drainage was not performed postoperatively in any of the patients. Postoperative CSF leakage occurred in four patients (1.7%) due to technical mistakes and were repaired with the same technique. However, postoperative meningitis occurred in 13.5% (n=31) of the patients, but no microorganisms were identified. The median latency to the diagnosis of meningitis was 8 days (range, 2-38). CSF leakage was the unique risk factor for postoperative meningitis (p<0.001). Conclusion : The use of multiple onlay grafts with FSP, HAC, and PNF is a reliable reconstruction technique that provides immediate and complete CSF leakage repair and mucosal grafting on the skull base without the need to harvest autologous tissue or perform postoperative CSF diversion. However, postoperative meningitis should be monitored carefully.

유체-구조물 상호작용을 고려한 면진구조물의 추계학적 응답해석 (Stochastic Analysis of Base-Isolated Pool Structure Considering Fluid-Structure Interaction Effects)

  • 고현무;김재관;박관순;하동호
    • 대한토목학회논문집
    • /
    • 제14권3호
    • /
    • pp.463-472
    • /
    • 1994
  • Random 지반운동에 대한 면진수조구조물 응답의 추계학적 해석방법을 연구하였다. 유연한 벽체와 내부유체간의 유체구조물 상호작용은 유체운동의 유한요소 모델링에 의하여 얻어지는 부가질량행렬 형태로 고려되었다. 정상(定常)(Stationary)지반운동으로는 수정된 Clough-Penzien Spectral Model이 사용되었으며, 비정상(非定常)(Nonstationary)지반운동으로는 상기모델에 포락함수를 적용한 모델을 사용하였다. 운동을 지배하는 Lyapunov Covariance Matrix 미분방정식의 해를 구하여 두 종류 면진시스템의 정상응답 및 비정상응답을 해석하였다.

  • PDF

점성유체 감쇠기의 동특성에 관한 실험적 연구 (An Experimental Study of the Dynamic Characteristics of Viscous Fluid Dampers)

  • 권형오
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.243-248
    • /
    • 1998
  • This study was performed to obtain a numerical model for a viscous fluid damper from an experimental testing. The input signals for displacement were chosen as two types : a triangular and a sinusoidal forms. The performing test parameters were the area of the resistant plate, relative velocity between resistant plate and base plate, oil film thickness of the viscous fluid, but the temperature effect was neglected. The numerical model was established by assuming an non-Newtonian fluid behavior. The test results were summarized by the equation of F= 0.0308(ν/d)0.5125. Using the obtained for a real structure design was introduced.

  • PDF

Improving Flow Distribution in a Suction Channel for a Highly Efficient Centrifugal Compressor

  • Yagi, Manabu;Shibata, Takanori;Kobayashi, Hiromi;Tanaka, Masanori;Nishida, Hideo
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권3호
    • /
    • pp.100-108
    • /
    • 2012
  • Design parameters for suction channels of process centrifugal compressors were investigated, and an optimization method to enhance stage efficiency by using the new design parameters was proposed. From results of computational fluid dynamics, the passage sectional area ratios $A_c/A_e$, $A_e/A_s$ and $A_c/A_s$ were found to be the dominant parameters for the pressure loss and circumferential flow distortion, where $A_c$, $A_e$ and $A_s$ are passage sectional areas for the casing upstream side, casing entrance and impeller eye, respectively. The Base suction channel was optimized using the new design parameters, and the Base and Optimized types were tested. Test results showed that the Optimized suction channel achieved 3.8% higher stage efficiency than the Base suction channel while maintaining the same operating range.

면진수조의 2차원 동적 해석기법 개발 (2-D Dynamic analysis method of base-isolated pool structure)

  • 전영선;최인걸;김진웅
    • 전산구조공학
    • /
    • 제8권3호
    • /
    • pp.67-74
    • /
    • 1995
  • 본 연구에서는 면진수조의 2차원 동적 해석기법을 개발하고 축소모델을 사용한 진동대실험을 통하여 해석기법의 타당성을 검증하였다. 수조의 벽체는 집중질량을 사용하여 모델링하였으며 유체의 부가질량을 벽체의 절점에 부가함으로써 유체의 동수역학적인 영향을 고려하였다. 면진수조의 운동방정식은 벽체와 유체로 구성된 상부구조의 운동방정식과 바닥슬래브와 면진장치로 구성된 하부구조의 운동방정식을 연계하여 구하였다. 진동대 실험에서는 투명한 아크릴로 제작한 모형수조를 사용하였으며 면진장치는 4개의 고감쇠 적층 고무베어링(High Damping Laminated Rubber Bearing)을 사용하였다. 축소모델에 의한 실험결과는 대체적으로 해석결과와 잘 일치하였으며 계산결과가 다소 보수적인 것으로 나타났다.

  • PDF

내부유체를 가진 Pin Fin의 최적화 (고정된 핀 체적 기준) (Optimization of a Pin Fin with inside Fluid (based on Fixed Fin Volume))

  • 강형석
    • 산업기술연구
    • /
    • 제29권B호
    • /
    • pp.3-7
    • /
    • 2009
  • A cylindrical pin fin with inside fluid is optimized based on fixed fin volume by using the one dimensional analytic method. Heat loss from the fin and the pin fin radius for fixed fin volume is presented as a function of the fin length. Temperature variation of the fin with the variation of ambient and inside fluid convection characteristic numbers and fin base thickness is listed. The maximum heat loss at the practical fin length and corresponding optimum fin length and radius are presented as a function of fin base thickness, inside convection characteristic number, fin volume and ambient convection characteristic number. One of the results shows that the optimum pin fin shape becomes relatively fatter as the fin volume increases.

  • PDF

장방형 용기내 자성유체의 Benard유동에 대한 전열 제어 특성에 관한 연구 (A Study on the Heat Transfer Control Characteristics of Benard Flow a Magnetic Fluids in a Rectangular Enclosure)

  • 안종국;서이수;박길문
    • 한국유체기계학회 논문집
    • /
    • 제7권4호
    • /
    • pp.32-39
    • /
    • 2004
  • This study deals with the Benard Flow of Magnetic Fluids in a rectangular cavity which the ratio between height and width is 1 : 4 and the base side or left side is a heating face while other sides are to be cooling faces. When Magnetic field was equally impressed, considering the internal rotation of the elementary ferromagnetic particle, we found the following result from the numerical analysis of the GSMAC algorithm applied to the equation of the magnetic fluid. Benard flow is controlled by intensity and direction of magnetic fields, and critical point appears when especially magnetic field with a heating base and side area near H=-7000 and H=-10000 is applied.

다구찌법을 이용한 ER 댐퍼의 강건 설계 (Robust Design of an ER Damper using Taguchi Method)

  • 윤영민;배광식;김재환;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.157-162
    • /
    • 2003
  • This Paper presents a robust design of an Electrorheological(ER) damper using Taguchi method. Taguchi method is a robust design method that determines control parameters in the presence of noise effect. Electrode length, electrode gap, base oil viscosity and the weight ratio of ER particles are chosen for the control parameters and the temperature is considered to be a noise factor. The sensitivity of each factor with signal-to-noise(S/N) ratio and analysis of variance are investigated. The analysis results show that the electrode length and base oil viscosity of the ER fluid mostly affect the damping force in the absence of electric field. On the other hand, when the voltage is applied to the ER damper, the electrode length and the weight ratio of ER fluid exhibit significant effect. Based on the Taguchi method, an optimal configuration was designed and the robustness of the designed ER damper was validated by comparing the analysis and experimental results.

  • PDF