• Title/Summary/Keyword: Base Curve

Search Result 425, Processing Time 0.026 seconds

A Suggestion of an Empirical Equation for Shear Modulus Reduction Curve Estimation of Sandy Soils (사질토 전단탄성계수 감소곡선 산정을 위한 경험식 제안)

  • Park, Dug-Keun
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.126-126
    • /
    • 2002
  • In dynamic analyses such as seismic ground response and soil-structure interaction problems, it is very crucial to obtain accurate dynamic shear modulus of soil deposit. In this study, an extensive data base of available experimental data is compiled and reanalyzed to establish a simple empirical formula for the dynamic shear modulus reduction curve to cover wide range of strain for sandy soils. The proposed empirical equation is to represent the dynamic shear modulus degradation with strain in terms of low-amplitude dynamic shear modulus and effective mean confining Pressure, since those factors have the most significant effect on the Position and shape of the shear modulus reduction curve for nonelastic soils. If low-amplitude shear modulus is measured, degraded modulus at any shear strain amplitude can be calculated using the proposed equation.

A Suggestion of an Empirical Equation for Shear Modulus Reduction Curve Estimation of Sandy Soils (사질토 전단탄성계수 감소곡선 산정을 위한 경험식 제안)

  • Park, Dug-Keun
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.127-138
    • /
    • 2002
  • In dynamic analyses such as seismic ground response and soil-structure interaction problems, it is very crucial to obtain accurate dynamic shear modulus of soil deposit. In this study, an extensive data base of available experimental data is compiled and reanalyzed to establish a simple empirical formula for the dynamic shear modulus reduction curve to cover wide range of strain for sandy soils. The proposed empirical equation is to represent the dynamic shear modulus degradation with strain in terms of low-amplitude dynamic shear modulus and effective mean confining Pressure, since those factors have the most significant effect on the Position and shape of the shear modulus reduction curve for nonelastic soils. If low-amplitude shear modulus is measured, degraded modulus at any shear strain amplitude can be calculated using the proposed equation.

Fitting of Soft Contact Lenses (소프트 콘택트 렌즈의 피팅)

  • Lee, Eun-Hee;Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.173-180
    • /
    • 2000
  • To determine the effect of base curve and diameter of soft contact lenses on the fitting under the various corneal curvature, the model eyes which was made of either stainless steel or ordinary wood, were used as the substitutes for human eyes. The evaluations of fit of the soft contact lenses on both wood model eyes and human eyes were found to be very similar to each other. All the contact lenses except very thin ones became flat after fit on the stainless steel model eyes because the model eye could not preserve enough moisture to hold the edge of contact lenses on the steel ball's surface. The relationships between the base curves of contact lenses and radii of cornea for the optimum (normal) fit were measured as follows : corneal curvature (C.C)<7.6 mm : base curve(B.C) 8.4 mm, C.C 7.6~7.8 mm : B.C 8.4~8.5 mm. C.C 7.8~8.1 mm : B.C 8.6 mm. It is concluded that larger base curve is required for the eyes which have abnormal bulge on its cornea. It is found that very thin soft contact lenses can be easily twisted or folded regardless of moisture content when they were fit on the relatively dry eyes(corneas).

  • PDF

The Change in the Parameters of Silicone Hydrogel Lens and Objective/Subjective Symptoms induced by Repetitive Dryness of Lens (실리콘 하이드로겔 렌즈의 반복적 건조로 인한 렌즈형태 및 자·타각적 증상의 변화)

  • Kim, So Ra;Kang, Byeong Ho;Jung, In Pil;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.381-388
    • /
    • 2012
  • Purpose: In this study, the changes in the shape of silicone hydrogel lenses, dryness of lens and objective/ subjective symptoms that could be induced by repeating dryness of lens and objective/subjective symptoms were investigated. Methods: After drying and rehydrating of silicone hydrogel lenses with different lens material and thickness for 4 times, their overall diameters and base curves were compared. Subjective symptoms, non-invasive tear break-up time (NIBUTs) and blinking rate were evaluated after wearing dehydrated silicone hydrogel lens. Results: Overall diameter and base curve increased in all tested silicone hydrogel lenses by repeating dryness and rehydration. The degree of change in over all diameter and base curve were variable on the material. There were irregular change of lens parameters in thicker lens. When the subjects wore silicone hydrogel lenses after drying and rehydrating, their NIBUTs were decreased and blink rates were increased regardless of lens material or thickness. In addition, repetitive drying of silicone hydrogel lenses affected the lens fitting. Therefore, subjective symptoms such as itching, pain, irritation, foreign body sensation, dryness tended to be increased. Conclusions: The results obtained from the study may suggest to develop durable silicone hydrogel contact lenses against dry environment since the changes in parameters of silicone hydrogel lens and the subjective discomfort were observed after repetitive drying and rehydration.

Estimating Maintenance Cost of RAPCON at Air Force Base (비행기지 RAPCON 유지보수비용 추정)

  • Bang, Jang-Kyu;Lee, Gun-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.6
    • /
    • pp.511-518
    • /
    • 2016
  • RAPCON non only controls landing/take-off procedures but also approaching air traffics within 60-70 NM range of air force base. This paper, first of all, tries to research the failure rate per operation hours, mean time between failure (MTBF) of RAPCON according to six blocks such as interrogator, receiver, power unit, display unit, data process unit and antenna. In addition, this paper estimates the maintenance cost over next 10 months based on 50 monthly maintenance cost data. Considering the maintenance cost data from RAPCON which has been used over designed service life span, it is no doubt the forecasted data proved the monthly cost would go up incrementally during the rest of economic life of the facility. Such research result is also proven to be the same with the result of bathtub curve data during operating life.

Very long life fatigue behaviors of 16Mn steel and welded joint

  • Liu, Yongjie;He, Chao;Huang, Chongxiang;Khan, Muhammad K.;Wang, Qingyuan
    • Structural Engineering and Mechanics
    • /
    • v.52 no.5
    • /
    • pp.889-901
    • /
    • 2014
  • Very long life fatigue tests were carried out on 16Mn steel base metal and its welded joint by using the ultrasonic fatigue testing technique. Specimen shapes (round and plate) were considered for both the base metal and welded joint. The results show that the specimens present different S-N curve characteristics in the region of $10^5-10^9$ cycles. The round specimens showed continuously decreasing tendency while plate specimens showed a steep decreasing step and an asymptotic horizontal one. The fatigue strength of round specimen was found higher than plate specimen. The fatigue strength of as-welded joint was 45.0% of the base material for butt joint and 40% for cruciform as-welded joint. It was found that fracture can still occur in butt joint beyond $5{\times}10^6$ cycles. The cruciform joint has a fatigue limit in the very long life fatigue regime ($10^7-10^9$ cycles). Fatigue strength of butt as-welded joint was much higher as compared to cruciform as-welded joint. Improvement in fatigue strength of welded joint was found due to UPT. The observation of fracture surface showed crack mainly initiated from welded toe at fusion areas or geometric discontinuity sites at the surface in butt joint and from welded toe in cruciform joint.

Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests (원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가)

  • Yoo, Min-Taek;Kwon, Sun-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.7
    • /
    • pp.51-58
    • /
    • 2018
  • In this study a series of centrifuge tests were carried out in dry sand to analyze the comparison of lateral pile behavior for static loading and dynamic loading condition. In case of static loading condition, the lateral displacement was applied up to 50% of pile diameter by deflection control method. And the input sine wave of 0.1 g~0.4 g amplitude and 1 Hz frequency was applied at the base of the soil box using shaking table for dynamic loading condition. From comparison of experimental static p-y curve obtained from static loading tests with API p-y curves, API p-y curves can predict well within 20% error the ultimate subgrade reaction force of static loading condition. The ultimate subgrade reaction force of experimental dynamic p-y curve is 5 times larger than that of API p-y curves and experimental static p-y curves. Therefore, pseudo-static analysis applied to existing p-y curve for seismic design could greatly underestimate the soil resistance at non-linear domain and cause overly conservative design.

Analysis of Stream Discharge Characteristic at Control Point for Runoff Model Application (유출모의를 위한 주요제어지점 유량특성 분석)

  • Lee, Sang-Jin;Lee, Bae-Sung;Ryoo, Kyong-Sik;Hwang, Man-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.11 s.172
    • /
    • pp.905-914
    • /
    • 2006
  • For an accurate rainfall-runoff simulation in the river basin, not evaluation of runoff model but accurate runoff data are very important. In this study, SSARR model was applied to the Geum River basin and these results are compared with runoff data observed at the Gongju gauging station. The model results didn't good fit the discharge data determined from the rating curve at Gongju gauging station during normal and dry season, especially. For the reliability analysis for the existing rating curve, we observed new stream discharge set from 2003 to 2005. We also estimated long term runoff data from the base flow separation method and defined the hydraulic characteristics. The results show that the new observed stream discharge is similar to the rainfall-runoff model results but existing rating curve seems to be overestimated about 10-20% during normal and dry season. We found that the continuous monitoring and update for the existing rating curve at the gaging station are needed for accurate estimation of runoff data.

LASER WELDING OF TI-NI SHAPE MEMORY ALLOY WIRE

  • Kim, Young-Sik;Kim, Jong-Do
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.139-144
    • /
    • 2002
  • Ti-50.9at%Ni wires were welded using pulsed YAG laser. The laser welded wires were tested for investigating the shape memo교 effect and the ability of super elasticity. The fatigue properties of the welded wires were investigated using the rotary bending fatigue tester specially designed for wires. Moreover, the effect of defocusing distance during laser welding on the static and fatigue properties was investigated. The shape memory effect and super elasticity of the laser welded wires were approximately identical with that of base metal at the test temperature below 353K. However, the welded wires were broken within elastic limit at the test temperature above 353k. Under the cyclic bending loading conditions, the welded wires could be useful only below the elastic limit, while the base metal had sufficient fatigue life even the stress induced M-phase region. The fatigue strength of the welded wires was about half of that of the base metal. The deterioration of the static and fatigue properties in the welded wires was proven to be from the large difference of the transformation behavior between the base metal and welded part that is caused by vaporization of Ni-content at the welded part during the welding process. The defocusing distance below 3mm acted more largely on lowering the strength of the welded wires than that of 6mm or 8mm.

  • PDF

Blast fragility of base-isolated steel moment-resisting buildings

  • Dadkhah, Hamed;Mohebbi, Mohtasham
    • Earthquakes and Structures
    • /
    • v.21 no.5
    • /
    • pp.461-475
    • /
    • 2021
  • Strategic structures are a potential target of the growing terrorist attacks, so their performance under explosion hazard has been paid attention by researchers in the last years. In this regard, the aim of this study is to evaluate the blast-resistance performance of lead-rubber bearing (LRB) base isolation system based on a probabilistic framework while uncertainties related to the charge weight and standoff distance have been taken into account. A sensitivity analysis is first performed to show the effect of explosion uncertainty on the response of base-isolated buildings. The blast fragility curve is then developed for three base-isolated steel moment-resisting buildings with different heights of 4, 8 and 12 stories. The results of sensitivity analysis show that although LRB has the capability of reducing the peak response of buildings under explosion hazard, this control system may lead to increase in the peak response of buildings under some explosion scenarios. This shows the high importance of probabilistic-based assessment of isolated structures under explosion hazard. The blast fragility analysis shows effective performance of LRB in mitigating the probability of failure of buildings. Therefore, LRB can be introduced as effective control system for the protection of buildings from explosion hazard regarding uncertainty effect.