• Title/Summary/Keyword: Barrier design

Search Result 734, Processing Time 0.029 seconds

Performance Assessment of Low- and Intermediate-Level Radioactive Waste Disposal Facility in Korea by Using Complementary Indicator: Case Study with Radionuclide Flux (보조지표를 활용한 중·저준위 처분시설 성능평가: 방사성 핵종 플럭스 사례연구)

  • Jung, Kang-Il;Jeong, Mi-Seon;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.73-86
    • /
    • 2015
  • The use of complimentary indicators, other than radiation dose and risk, to assess the safety of radioactive waste disposal has been discussed in a number of publications for providing the reasonable assurance of disposal safety and convincing the public audience. In this study, the radionuclide flux was selected as performance indicator to appraise the performance of engineered barriers and natural barrier in the Wolsong low- and intermediate-level waste disposal facility. Radionuclide flux showing the retention capability by each compartment of the disposal system is independent of assumptions in biosphere model and exposure pathways. The scenario considered as the normal scenario of disposal facility has been divided into intact or degraded silo concrete conditions. In the intact silo concrete, the radionuclide flux has been assessed with respect to the radionuclide retardation performance of each engineered barrier. In the degraded silo concrete, the radionuclide flux has been explored based on the performance degradation of engineered barriers and the relative significance of natural barrier quantitatively. The results can be used to optimally design the near-surface disposal facility being planned as the second project phase. In the future, additional complimentary indicators will be employed for strengthening the safety case for improving the public acceptance of low- and intermediate-level waste disposal facility.

A Reduction Effect in Noise Reflection by Different Shapes of Soundproofing-panel (도로소음원에 대한 방음패널 형상별 반사소음 저감효과)

  • Kim, Ilho;Park, Taeho;Chang, Seoil;Lee, Haein
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.120-125
    • /
    • 2015
  • With rapid urbanization, the volume of traffic in urban area has been significantly increased. This in turn led to problem which can be described as Road Traffic Noise. Currently, to alleviate the road traffic noise damage, a demand for installation of soundproofing walls is rising. Among different shapes of soundproof walls being installed, the reflection-type acoustical insulation panel is highly drawing attentions of residents due to the fact that it does not obstruct their field of vision in contrast with the opaque acoustical insulation panel. On the other hand, improving the soundproofing wall of the reflection-type acoustical insulation barrier panel needs to be focused on since it has a possibility to cause a secondary damage by reflected sounds. Therefore, in this research, study has been carried out to improve the forms in order to minimize travelling of reflected sounds through changing the frontal surface shape and geometrical shape of the reflection-type soundproofing panel. A result from comparison between the normal reflection-type soundproofing panel and the improved soundproofing panel, with reduction effects in the noise reflection, showed that the curved type of soundproofing panel has an impact on reducing the noise up to 1.5 dB. Furthermore, from the research conducted, it appears that the increase and decrease in the reflected sounds can be changeable depending on various design factors. Thus, it turns out that the study shows a potential possibility to develop a reduction technology of the reflected sounds pertaining to overall condition on the soundproofing walls.

Influence on Short Channel Effects by Tunneling for Nano structure Double Gate MOSFET (나노구조 이중게이트 MOSFET에서 터널링이 단채널효과에 미치는 영향)

  • Jung, Hak-Kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.479-485
    • /
    • 2006
  • The double gate(DG) MOSFET is a promising candidate to further extend the CMOS scaling and provide better control of short channel effect(SCE). DGMOSFETs, having ultra thin undoped Si channel for SCEs control, ale being validated for sub-20nm scaling. A novel analytical transport model for the subthreshold mode of DGMOSFETs is proposed in this paper. The model enables analysis of short channel effect such as the subthreshold swing(SS), the threshold voltage roil-off$({\Delta}V_{th})$ and the drain induced barrier lowering(DIBL). The proposed model includes the effects of thermionic emission and quantum tunneling of carriers through the source-drain barrier. An approximative solution of the 2D Poisson equation is used for the distribution of electric potential, and Wentzel-Kramers-Brillouin approximation is used for the tunneling probability. The new model is used to investigate the subthreshold characteristics of a double gate MOSFET having the gate length in the nanometer range $(5-20{\sim}nm)$ with ultra thin gate oxide and channel thickness. The model is verified by comparing the subthreshold swing and the threshold voltage roll-off with 2D numerical simulations. The proposed model is used to design contours for gate length, channel thickness, and gate oxide thickness.

Analysis of the Effects of Drainage Systems in Wetlands Based on Changes in Groundwater Level, Soil Moisture Content, and Water Quality (지하수위, 토양수분함량 및 수질변화를 활용한 습윤화 지역의 배수시설 효과 평가)

  • Kim, Chang-Hoon;Ryu, Jeong-Ah;Kim, Deog-Geun;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.26 no.2
    • /
    • pp.251-260
    • /
    • 2016
  • Groundwater flow due to hydraulic gradients across a geologic barrier surrounding a dam reservoir can cause swamps or wetlands to form on the downstream side of the dam, thereby restricting land use. The difference in head between the reservoir level and the downstream groundwater level creates a hydraulic gradient, allowing water to flow through the geologic barrier. We constructed a drainage system at the Daecheong dam to study the effects on groundwater levels and soil moisture contents. The drainage system consisted of a buried screened pipe spanning a depth of 1-1.5 m below a land surface. Groundwater levels were monitored at several monitoring wells before and after the drainage system was installed. Most well sites recorded a decline in groundwater level on the order of 1 m. The high-elevated site (monitoring well W1) close to the reservoir showed a significant decline in groundwater level of more than 2 m, likely due to rapid discharge by the drainage system. Soil moisture contents were also analyzed and found to have decreased after the installation of the drainage system, even considering standard deviations in the soil moisture contents. We conclude that the drainage system effectively lowered groundwater levels on the downstream side of the dam. Furthermore, we emphasize that water seepage analyses are critical to embankment dam design and construction, especially in areas where downstream land use is of interest.

Fabrication of 3D Paper-based Analytical Device Using Double-Sided Imprinting Method for Metal Ion Detection (양면 인쇄법을 이용한 중금속 검출용 3D 종이 기반 분석장치 제작)

  • Jinsol, Choi;Heon-Ho, Jeong
    • Clean Technology
    • /
    • v.28 no.4
    • /
    • pp.323-330
    • /
    • 2022
  • Microfluidic paper-based analytical devices (μPADs) have recently been in the spotlight for their applicability in point-of-care diagnostics and environmental material detection. This study presents a double-sided printing method for fabricating 3D-μPADs, providing simple and cost effective metal ion detection. The design of the 3D-μPAD was made into an acryl stamp by laser cutting and then coating it with a thin layer of PDMS using the spin-coating method. This fabricated stamp was used to form the 3D structure of the hydrophobic barrier through a double-sided contact printing method. The fabrication of the 3D hydrophobic barrier within a single sheet was optimized by controlling the spin-coating rate, reagent ratio and contacting time. The optimal conditions were found by analyzing the area change of the PDMS hydrophobic barrier and hydrophilic channel using ink with chromatography paper. Using the fabricated 3D-μPAD under optimized conditions, Ni2+, Cu2+, Hg2+, and pH were detected at different concentrations and displayed with color intensity in grayscale for quantitative analysis using ImageJ. This study demonstrated that a 3D-μPAD biosensor can be applied to detect metal ions without special analysis equipment. This 3D-μPAD provides a highly portable and rapid on-site monitoring platform for detecting multiple heavy metal ions with extremely high repeatability, which is useful for resource-limited areas and developing countries.

A Study on the Analysis of Virus Barrier Materials in a Chest X-ray Laboratory to Respiratory and Droplet Infections Only Patients (호흡기 및 비말감염 환자 전용 흉부 X-선 검사실의 바이러스 차단제 분석에 관한 연구)

  • Kim, Hyeon-Ju;Lee, Jun-Ho;Choi, Kwan-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.169-175
    • /
    • 2022
  • In this study, envisioned a laboratory equipped with virus blocking equipment for chest X-ray examinations of respiratory or droplet-transmitted virus-infected patients, and the material with the least deterioration in X-ray output and image quality among the proven blocking materials that block viruses in the design process. and experimented to find the thickness. As a result, when 1 cm of acrylic was applied, the X-ray output was reduced by only about 3.27 % compared to the absence of the barrier material, the SNR was 40.7 and CNR was 30.9, which was the best. The SSIM index result was analyzed as 0.891, which was analyzed to be implemented as the most similar image compared to the original image. The barrier material applied in the research method was objective in that it used a product approved by the Ministry of Food and Drug Safety. the results of this study are expected to provide useful information when installing X-ray examination facilities for the diagnosis and treatment of respiratory-related virus-infected patients in the future.

Vehicle Collision Simulation for Roadblocks in Nuclear Power Plants Using LS-DYNA (LS-DYNA를 이용한 원자력발전소의 로드블록에 대한 차량 충돌 시뮬레이션)

  • SeungGyu Lee;Dongwook Kim;Phill-Seung Lee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.113-120
    • /
    • 2023
  • This paper introduces a simulation method for the collision between roadblocks and vehicles using LS-DYNA. The need to evaluate the performance of anti-ram barriers to prepare for vehicle impact has increased since vehicle impact threats have been included as a design criterion for nuclear power plants. Anti-ram barriers are typically certified for their performance through collision experiments. However, because Koreas has no performance testing facilities for anti-ram barriers, their performance can only be verified through simulations. LS-DYNA is a specialized program for collision simulation. Various organizations, including NCAC, distributes numerical models that have been validated for their accuracy with collision tests. In this study, we constructed a finite element model of the most critical vehicle barrier module and simulated collision between roadblocks and vehicles. The calculated results were verified by applying the validation criteria for vehicle safety facility collision simulations of NCHRP 179.

Skin Barrier Strengthening and Moisturizing Effect of Essence Containing Coptis Japonica Extract (황련 추출물을 함유한 에센스의 피부장벽강화 및 보습 효과)

  • Kyung Nam Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.936-944
    • /
    • 2023
  • The purpose of this study is to verify the effect of essence containing Coptis Japonica extract on skin barrier strengthening and moisturizing. The essence containing the Coptis Japonica extract was used by 22 subjects for four weeks, and the amount of percutaneous water loss (g/m2h) and water (A.U.) in the designated upper limit were measured. As a result of measuring percutaneous water loss using a vapometer, it was found to be 11.08±2.55 after 4 weeks of use from 14.82±4.01 before use, and the significance probability decreased significantly by 25.27% to p<0.001. The amount of skin moisture measured by the Corneometer was found to be 46.73±7.45 after use from 31.73±8.09 before use, and the significance probability increased by 47.26% to p<0.001, and the subject's subjective efficacy evaluation through a questionnaire showed that all subjects were 100% satisfied without skin adverse reactions. As a result of this, it has been confirmed that Coptis Japonica essence is effective in strengthening skin barriers and moisturizing, which is expected to be a cornerstone for the development of cosmetics using various activities of Coptis Japonica extract in the future.

Optimization of Gas Mixing-circulation Plasma Process using Design of Experiments (실험계획법을 이용한 가스 혼합-순환식 플라즈마 공정의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.359-368
    • /
    • 2014
  • The aim of our research was to apply experimental design methodology in the optimization of N, N-Dimethyl-4-nitrosoaniline (RNO, which is indictor of OH radical formation) degradation using gas mixing-circulation plasma process. The reaction was mathematically described as a function of four independent variables [voltage ($X_1$), gas flow rate ($X_2$), liquid flow rate ($X_3$) and time ($X_4$)] being modeled by the use of the central composite design (CCD). RNO removal efficiency was evaluated using a second-order polynomial multiple regression model. Analysis of variance (ANOVA) showed a high coefficient of determination ($R^2$) value of 0.9111, thus ensuring a satisfactory adjustment of the second-order polynomial multiple regression model with the experimental data. The application of response surface methodology (RSM) yielded the following regression equation, which is an empirical relationship between the RNO removal efficiency and independent variables in a coded unit: RNO removal efficiency (%) = $77.71+10.04X_1+10.72X_2+1.78X_3+17.66X_4+5.91X_1X_2+3.64X_2X_3-8.72X_2X_4-7.80X{_1}^2-6.49X{_2}^2-5.67X{_4}^2$. Maximum RNO removal efficiency was predicted and experimentally validated. The optimum voltage, air flow rate, liquid flow rate and time were obtained for the highest desirability at 117.99 V, 4.88 L/min, 6.27 L/min and 24.65 min, respectively. Under optimal value of process parameters, high removal(> 97 %) was obtained for RNO.

Optimization of Air-plasma and Oxygen-plasma Process for Water Treatment Using Central Composite Design and Response Surface Methodology (중심합성설계와 반응표면분석법을 이용한 수처리용 산소-플라즈마와 공기-플라즈마 공정의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.907-917
    • /
    • 2011
  • This study investigated the application of experimental design methodology to optimization of conditions of air-plasma and oxygen-plasma oxidation of N, N-Dimethyl-4-nitrosoaniline (RNO). The reactions of RNO degradation were described as a function of the parameters of voltage ($X_1$), gas flow rate ($X_2$) and initial RNO concentration ($X_3$) and modeled by the use of the central composite design. In pre-test, RNO degradation of the oxygen-plasma was higher than that of the air-plasma though low voltage and gas flow rate. The application of response surface methodology (RSM) yielded the following regression equation, which is an empirical relationship between the RNO removal efficiency and test variables in a coded unit: RNO removal efficiency (%) = $86.06\;+\;5.00X_1\;+\;14.19X_2\;-\;8.08X_3\;+\;3.63X_1X_2\;-\;7.66X_2^2$ (air-plasma); RNO removal efficiency (%) = $88.06\;+\;4.18X_1\;+\;2.25X_2\;-\;4.91X_3\;+\;2.35X_1X_3\;+\;2.66X_1^2\;+\;1.72X_3^2$ (oxygen-plasma). In analysis of the main effect, air flow rate and initial RNO concentration were most important factor on RNO degradation in air-plasma and oxygen-plasma, respectively. Optimized conditions under specified range were obtained for the highest desirability at voltage 152.37 V, 135.49 V voltage and 5.79 L/min, 2.82 L/min gas flow rate and 25.65 mg/L, 34.94 mg/L initial RNO concentration for air-plasma and oxygen-plasma, respectively.