• 제목/요약/키워드: Bare Metal Stent

검색결과 14건 처리시간 0.02초

Fabrication and Evaluation of Polyelectrolyte Complexes of Dextran Derivatives for Drug Coating of Coronary Stents

  • Jang, Eun-Jae;Lee, So-Youn;Bae, In-Ho;Park, Dae Sung;Jeong, Myung Ho;Park, Jun-Kyu
    • 공업화학
    • /
    • 제30권5호
    • /
    • pp.586-590
    • /
    • 2019
  • The aim of this study was to fabricate a dextran polyelectrolyte multi-layer on a bare metal stent (BMS) and to evaluate bio-physical properties of the layer. Diethylaminoethyl-dextran (DEAE-D) as a polycation and dextran sulfate (DS) as a polyanion were successively coated on the bare metal stent by a well-known layer-by-layer procedure. The morphology of the stent surface and its cell adhesion were studied after each coating step by scanning electron microscopy. The stent showed more blotched and slightly rougher morphology after dextran-DS coating. The contact angle of the DEAE-DS group ($39.5{\pm}0.15^{\circ}$) was significantly higher than that of the BMS group ($45.16{\pm}0.08^{\circ}$), indicating the improvement of hydrophilic. The SMC proliferation inhibition in the DEAE-DS-coated stent group ($20.9{\pm}0.04%$) was stronger than that in the control group ($21.7{\pm}0.10%$ in DS-coated group only). The DEAE-DS coating is desired for stent coating materials with biocompatibility and anti-restenosis effect.

Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis

  • Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1241-1248
    • /
    • 2023
  • Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

Coating defects in polymer-coated drug-eluting stents

  • Bedair, Tarek M.;Cho, Youngjin;Park, Bang Ju;Joung, Yoon Ki;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권3호
    • /
    • pp.131-150
    • /
    • 2014
  • Vascular stenting has a great attention as a treatment for coronary arteries diseases as compared with percutaneous balloon angioplasty. In-stent restenosis and thrombosis are side effects resulting from using bare metal stent (BMS). Employing platelet therapy allowed to reduce the rate of thrombosis, however, the rate of restenosis remains a major problem. In 2002, drug-eluting stents (DESs) were introduced as an effort to reduce the restenosis. The commercially available DESs continue to suffer from coating defects that might lead to a series of adverse effects. Most importantly, multiple concerns remain regarding the polymer coating integrity on metal surfaces or the relation of polymer irregularities to longterm adverse events.

약물 용출 스텐트와 일반 금속 스텐트에서 혈전증에 대한 발생과 예후 (Occurrence and Prognosis for the Thrombosis in the Drug-Eluting Stents and Bare-Metal Stents)

  • 김인수;최남길;장성주;한재복;장영일
    • 한국콘텐츠학회논문지
    • /
    • 제12권7호
    • /
    • pp.273-283
    • /
    • 2012
  • 급성심근경색증 환자에서 약물 용출 스텐트(drug-eluting stents, DES)는 일반 금속 스텐트(bare-metal stents, BMS)에 비해 재협착은 감소하지만 구조적인 특성으로 스텐트 혈전증(stent thrombosis, ST)이 증가한다고 알려져 있다. 이에 본 연구에서는 ST의 발생빈도, 임상양상, 그리고 1년간 예후를 알아보고자 하였다. 대학병원 심혈관센터에서 급성심근경색증으로 관상동맥 중재술을 받은 2,667명에서 스텐트 혈전증이 발생한 환자 80명을 대상으로 DES-ST를 I군(n=57), BMS-ST(n=23)를 II군으로 분류하여 양군 간의 특징을 분석하였다. 양군간의 ST는 I군에서 57명(2.7%)과 II군에서 23명(4.3%)로 양군 간에 유의한 차이는 없었다(p>0.064). ST의 유형으로는 acute ST는 I군5(8.8%), II군3(2.3%), subacute ST는 I군 29(50.9%), II군14(60.9%), late ST 는 I군11(19.3%), II군2(8.7%), very late ST는 I군12(21.1%), II군 4(17.4%)로 양군간의 차이는 없었다(p>0.605). DES와 BMS를 삽입 후 1년 예후에 미치는 인자로는 ST(OR 8.166 95% CI 2.825-23.608 p<0.001), 좌심실구혈율(<40) (OR 6.409 95% CI 2.422-16.955 p<0.001), 나이(${\geq}$75세) (OR 4.979 95% CI 1.946-12.744 p=0.001) 이었다. ST의 발생율은 양군 사이에 차이가 없었고, 1년 예후에 미치는 인자로는 ST의 발생, 좌심실 구혈률의 저하 및 환자의 연령 등 이었다.

관상동맥혈관용 스텐트의 구조해석과 재료설계 (Material Design and Analysis of Coronary Artery Stents)

  • 박중권;강태원;이기성;김태우
    • 한국세라믹학회지
    • /
    • 제44권7호
    • /
    • pp.362-367
    • /
    • 2007
  • Stent is a tiny structure made with either ceramic coating and/or bare metal. Being approximately $1{\sim}2 mm$ in diameter, it consists of holes, slots, or void space and is designed to cover entire medical lesions. Stent implantation into patients' arteries has been practiced for a little more than a decade in order to widen the blocked artery. The adoption of the stent has significantly improved the efficacy when compared with the previous medical practice by balloon angioplasty alone. Yet better biomedical performance of the stent is being demanded in order to eliminate the still existing problem of artery restenosis, which means the artery becomes narrowed again. Recent literature survey shows researches on ceramic coatings onto the stent surface, or material design to improve the mechanical response of the stent. This study focuses more on the material design and mechanical analysis. The results showed that the void configuration within the stent affects the mechanical response significantly. The rectangular shape was found to yield expansion at a relatively lower pressure than the elliptical slot for a slotted tube stent. The present results, when combined with research on coating at the stent surface, may provide stents with improved bio-medical performance.

혈액투석 접근로 기능부전에서의 비피복형 스텐트: 접근로 종류와 스텐트 위치에 따른 개통률 평가 (Bare-Metal Stent in Dysfunctional Hemodialysis Access: An Assessment of Circuit Patency according to Access Type and Stent Location)

  • 이경민;원제환;권요한;이수형;방준배;김진우
    • 대한영상의학회지
    • /
    • 제84권1호
    • /
    • pp.197-211
    • /
    • 2023
  • 목적 기능장애 혈액투석 접근로에서 나이티놀 비피복형 스텐트 설치 후 접근로 유형과 스텐트의 위치에 따른 개통성을 평가하고자 한다. 대상과 방법 2017년 1월과 2019년 12월 사이에 159명의 환자(평균 연령, 64.1 ± 13.2세)가 혈액투석 접근로 기능장애를 치료를 위해 나이티놀 스텐트를 설치하였다. 스텐트의 위치는 다음과 같다; 18개 팔머리 정맥, 51개 노쪽피부정맥궁, 40개 위팔 정맥, 10개 문합부위 인접 정맥, 7개 동정맥 문합부 및 33개 인조혈관-정맥 문합부. 12개월 개통률은 카플란-마이어 방법과 콕스 회귀 모델로 평가하였다. 결과 총 159개의 스텐트가 103개의 자가동정맥루와 56개의 인조혈관접근로에 성공적으로 설치되었다. 인조혈관접근로는 자가동정맥루에 비해 12개월 일차 및 이차 개통률이 더 낮았다(일차 개통률; 25.0%대 44.7%; p = 0.005, 이차 개통률; 76.8%대 92.2%; p = 0.014). 스텐트 설치 후 노쪽피부정맥궁 및 인조혈관-정맥 문합부에서 다른 부위에 비해 12개월 일차 개통성이 불량하였다. 결론 나이티놀 비피복형 스텐트 설치 후 자가동정맥루는 인조혈관접근로와 비교하여 더 좋은 12개월 일차 및 이차 개통률을 보인다. 노쪽피부정맥궁 및 인조혈관-정맥 문합부의 스텐트는 다른 위치의 스텐트에 비해 더 낮은 12개월 일차 개통률을 보인다.

A Novel Deposition Method of PLGA Nanoparticles on Coronary Stents

  • Joo, Jae-Ryang;Nam, Hye-Yeong;Nam, So-Hee;Baek, In-Su;Pakr, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권5호
    • /
    • pp.1085-1087
    • /
    • 2009
  • Bare metal stents which were used to treat coronary artery disease have several biochemical problems. Polymerbased drug-eluting stents (DES) have opened up a new paradigm in the treatment of in-stent restenosis. Many studies and research programmes have proved that DES can prevent restenosis. In our study, paclitaxel-loaded poly (lactic-co-glycolic acid) (PLGA) nanoparticles have been deposited along the three dimensional scaffold of coronary stents by a method using self-assembling properties of colloidal particles. We found that the nanoparticles were deposited uniformly and closely packed. The amount of paclitaxel was easily controlled by the drug content of the nanoparticles and the deposition count.

미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석 (Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography)

  • 배인호;고정태;임경섭;박대성;김종민;정명호
    • 한국방사선학회논문지
    • /
    • 제6권2호
    • /
    • pp.93-98
    • /
    • 2012
  • 미세단층촬영기법은 전임상 동물실험 분석시 고해상도의 혈관 영상화를 위한 중요한 수단이다. 이는 조직 분석과 같이 샘플 훼손이 예상되는 분석 작업 이전에 비파괴적인 방법으로 2차원 또는 3차원 이미지 재구성할 수 있는 장점이 있다. 본 연구에서는 생체 이식용 의료기기인 스텐트를 동물모델에서 전임상 분석을 하는데 있어 미세단층촬영기법의 활용방법을 제시하고 금속 스텐트(BMS)와 약물(paclitaxel)이 코팅된 스텐트(DES)의 스텐트 내 재협착정도(ISR)를 토끼 모델을 이용하여 평가하고자 하였다. BMS와 DES를 무작위적으로 토끼의 장골동맥에 식립하고 4주 후에 스텐트가 식립된 주위 혈관을 적출한 다음 스텐트 내강에 조영제를 투여하였다. 미세단층촬영기를 이용하여 50kV/200${\mu}A$의 X-ray 조사량으로 샘플을 스캔하였다. 정량적 분석을 위해 CTAN 소프트웨어를 이용하여 관심영역을 지정하여 정량적 분석을 수행하였다. 피폭 대상에 따라 각기 다른 CT값(Hounsfied Unit)을 획득할 수 있었으며(스텐트 영역; 약 1.2, 조영제 영역; 0.12~0.17, X-ray 비흡수 영역; 0~0.06), 이를 이용하여 2차원, 3차원적 영상을 획득하고 스텐트내 재협착 면적을 산출하였다. 조직병리학적 분석의 염증지수에 해당할 수 있는 확장된 스텐트의 크기를 측정하였을 때 BMS와 DES간의 유의한 차이가 나타나지 않았다. 또한 BMS 그룹의 ISR($1.52{\pm}0.48mm2$)이 DES의 ISR($0.94{\pm}0.42mm2$)에 비해 약 1.6배 높은 것으로 확인되었다. 이는 DES에 코팅된 paclitaxel이 세포 증식을 억제하여 스텐트 내강으로 증식하는 것을 저해하였기 때문으로 판단된다. 2차원적 분석 결과 BMS의 재협착 분포는 스텐트 중간 영역에서 전면부와 후면부에 비해 비교적 높은 것으로 확인되었다. 이러한 연구 결과로 볼 때 미세단층촬영기법은 비파괴적인 방법으로 분석이 가능하며 정량적 분석을 위한 기존의 복잡한 조직병리학적 분석법의 보조적인 수단으로 활용될 수 있을 것이다.