• Title/Summary/Keyword: Bare Metal

Search Result 107, Processing Time 0.032 seconds

Effect of Metal Interlayers on Nanocrystalline Diamond Coating over WC-Co Substrate (초경합금에 나노결정질 다이아몬드 코팅 시 금속 중간층의 효과)

  • Na, Bong-Kwon;Kang, Chan Hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.2
    • /
    • pp.68-74
    • /
    • 2013
  • For the coating of diamond films on WC-Co tools, a buffer interlayer is needed because Co catalyzes diamond into graphite. W and Ti were chosen as candidate interlayer materials to prevent the diffusion of Co during diamond deposition. W or Ti interlayer of $1{\mu}m$ thickness was deposited on WC-Co substrate under Ar in a DC magnetron sputter. After seeding treatment of the interlayer-deposited specimens in an ultrasonic bath containing nanometer diamond powders, $2{\mu}m$ thick nanocrystalline diamond (NCD) films were deposited at $600^{\circ}C$ over the metal layers in a 2.45 GHz microwave plasma CVD system. The cross-sectional morphology of films was observed by FESEM. X-ray diffraction and visual Raman spectroscopy were used to confirm the NCD crystal structure. Micro hardness was measured by nano-indenter. The coefficient of friction (COF) was measured by tribology test using ball on disk method. After tribology test, wear tracks were examined by optical microscope and alpha step profiler. Rockwell C indentation test was performed to characterize the adhesion between films and substrate. Ti and W were found good interlayer materials to act as Co diffusion barriers and diamond nucleation layers. The COFs on NCD films with W or Ti interlayer were measured as less than 0.1 whereas that on bare WC-Co was 0.6~1.0. However, W interlayer exhibited better results than Ti in terms of the adhesion to WC-Co substrate and to NCD film. This result is believed to be due to smaller difference in the coefficients of thermal expansion of the related films in the case of W interlayer than Ti one. By varying the thickness of W interlayer as 1, 2, and $4{\mu}m$ with a fixed $2{\mu}m$ thick NCD film, no difference in COF and wear behavior but a significant change in adhesion was observed. It was shown that the thicker the interlayer, the stronger the adhesion. It is suggested that thicker W interlayer is more effective in relieving the residual stress of NCD film during cooling after deposition and results in stronger adhesion.

Development of New Materials of Ginseng by Nanoparticles

  • Yang, Deok Chun;Mathiyalagan, Ramya;Yang, Dong Uk;Perez, Zuly Elizabeth Jimenez;Hurh, Joon;Ahn, Jong Chan
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.04a
    • /
    • pp.3-3
    • /
    • 2018
  • For centuries, Panax ginseng Meyer (Korean ginseng) has been widely used as a medicinal herb in Korea, China, and Japan. Ginsenosides are a class of triterpene saponins and recognized as the bioactive components in Korean ginseng. Ginsenosides, which can be classified broadly as protopanaxadiols (PPD), protopanaxatriols (PPT), and oleanolic acids, have been shown to flaunt a vast array of pharmacological activities such as immune-modulatory, anti-inflammatory, anti-tumor, anti-diabetic, and antioxidant effects. In recent years, a number of ginseng and ginsenoside researches have increasingly gained wide attention owing to its unique pharmacological properties. Although good efficacies of ginsenosides have been reported, lack of target specific delivery into tumor sites, low solubility, and low bioavailability due to modifications in gastro-intestinal environments limit their biomedical application in clinical trials. As a result to this major challenge, nanotechnology and drug delivery techniques play a significant role to solve this problematic issue. Thus, we reported the preparation of poly-ethylene glycol (PEG) and glycol chitosan (GC) functionalized to ginsenoside (Compound K and PPD) conjugates via hydrolysable ester bonds with improved aqueous solubility and pH-dependent drug release. In vitro cytotoxicity assays revealed that PEG-CK, and PPD-CK conjugates exhibited lower cytotoxicity compared to bare CK and PPD in HT29 cells. However, GC-CK conjugates exhibited higher and similar cytotoxicity in HT29 and HepG2 cells. Furthermore, GC-CK-treated RAW264.7 cells did not exhibit significant cell death at higher concentration of treatment which supports the biocompatibility of the polymer conjugates. They also inhibited nitric oxide production in lipopolysaccharide (LPS)-induced RAW64.7 cells. In addition to polymer-ginsenoside conjugates, silver (AgNps) and gold nanoparticles (AuNps) have been successfully synthesized by green chemistry using different m. The biosynthesized nanoparticles demonstrated antimicrobial efficacy, anticancer, anti-inflammatory, antioxidant activity, biofilm inhibition, and anticoagulant effect. Special interest on the effective delivery methods of ginsenoside to treatment sites is the focus of metal nanoparticle research.In short, nano-sizing of ginsenoside results in an increased water solubility and bioavailability. The use of nano-sized ginsenoside and P. ginseng mediated metallic nanoparticles is expected to be effective on medical platform against various diseases in the future.

  • PDF

Continuous Wet Oxidation of TCE over Supported Metal Oxide Catalysts (금속산화물 담지촉매상에서 연속 습식 TCE 분해반응)

  • Kim, Moon Hyeon;Choo, Kwang-Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.206-214
    • /
    • 2005
  • Heterogeneously-catalyzed oxidation of aqueous phase trichloroethylene (TCE) over supported metal oxides has been conducted to establish an approach to eliminate ppm levels of organic compounds in water. A continuous flow reactor system was designed to effect predominant reaction parameters in determining catalytic activity of the catalysts for wet TCE decomposition as a model reaction. 5 wt.% $CoO_x/TiO_2$ catalyst exhibited a transient period in activity vs. on-stream time behavior, suggesting that the surface structure of the $CoO_x$ might be altered with on-stream hours; regardless, it is probable to be the most promising catalyst. Not only could the bare support be inactive for the wet decomposition reaction at $36^{\circ}C$, but no TCE removal also occurred by the process of adsorption on $TiO_2$ surface. The catalytic activity was independent of all particle sizes used, thereby representing no mass transfer limitation in intraparticle diffusion. Very low TCE conversion appeared for $TiO_2$-supported $NiO_x$ and $CrO_x$ catalysts. Wet oxidation performance of supported Cu and Fe catalysts, obtained through an incipient wetness and ion exchange technique, was dependent primarily on the kinds of the metal oxides, in addition to the acidic solid supports and the preparation routes. 5 wt.% $FeO_x/TiO_2$ catalyst gave no activity in the oxidation reaction at $36^{\circ}C$, while 1.2 wt.% Fe-MFI was active for the wet decomposition depending on time on-stream. The noticeable difference in activity of the both catalysts suggests that the Fe oxidation states involved to catalytic redox cycle during the course of reaction play a significant role in catalyzing the wet decomposition as well as in maintaining the time on-stream activity. Based on the results of different $CoO_x$ loadings and reaction temperatures for the decomposition reaction at $36^{\circ}C$ with $CoO_x/TiO_2$, the catalyst possessed an optimal $CoO_x$ amount at which higher reaction temperatures facilitated the catalytic TCE conversion. Small amounts of the active ingredient could be dissolved by acidic leaching but such a process gave no appreciable activity loss of the $CoO_x$ catalyst.

Performance Evaluation and Analysis on Single and Multi-Network Virtualization Systems with Virtio and SR-IOV (가상화 시스템에서 Virtio와 SR-IOV 적용에 대한 단일 및 다중 네트워크 성능 평가 및 분석)

  • Jaehak Lee;Jongbeom Lim;Heonchang Yu
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.2
    • /
    • pp.48-59
    • /
    • 2024
  • As functions that support virtualization on their own in hardware are developed, user applications having various workloads are operating efficiently in the virtualization system. SR-IOV is a virtualization support function that takes direct access to PCI devices, thus giving a high I/O performance by minimizing the need for hypervisor or operating system interventions. With SR-IOV, network I/O acceleration can be realized in virtualization systems that have relatively long I/O paths compared to bare-metal systems and frequent context switches between the user area and kernel area. To take performance advantages of SR-IOV, network resource management policies that can derive optimal network performance when SR-IOV is applied to an instance such as a virtual machine(VM) or container are being actively studied.This paper evaluates and analyzes the network performance of SR-IOV implementing I/O acceleration is compared with Virtio in terms of 1) network delay, 2) network throughput, 3) network fairness, 4) performance interference, and 5) multi-network. The contributions of this paper are as follows. First, the network I/O process of Virtio and SR-IOV was clearly explained in the virtualization system, and second, the evaluation results of the network performance of Virtio and SR-IOV were analyzed based on various performance metrics. Third, the system overhead and the possibility of optimization for the SR-IOV network in a virtualization system with high VM density were experimentally confirmed. The experimental results and analysis of the paper are expected to be referenced in the network resource management policy for virtualization systems that operate network-intensive services such as smart factories, connected cars, deep learning inference models, and crowdsourcing.

Hybrid Off-pump Coronary Artery Bypass Combined with Percutaneous Coronary Intervention: Indications and Early Results (심폐바이패스 없이 시행하는 관상동맥우회술과 경피적 관상동맥중재술의 병합요법 : 적응증 및 조기성적)

  • Hwang Ho Young;Kim Jin Hyun;Cho Kwang Ree;Kim Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.733-738
    • /
    • 2005
  • Background: The possibility of incomplete revascularization and development of flow competition after revascularization of the borderline lesion made the hybrid strategy as an option for complete revascularization. Material and Method: From January f998 to July 2004, 25 $(3.2\%)$ patients underwent hybrid revascularization among 782 total OPCAB procedures. Clinical results and angiographic patencies were evalulated. Percutaneous coronary intervention (PCI) was peformed before CABG in 8 patients and after CABG in 47 patients. Result: The causes of PCIs before CABG were to achieve complete revascularization with minimally invasive surgery (n=7) and emergent PCI for culprit lesion (n=1). The indications of PCIs after CABG were high possibility of flow competition in the borderline lesion of right coronary artery territory (n=8), diffuse atheromatous lesion preventing anastomosis of graft (n=5), severe calcified ascending aorta with no more arterial grafi available (n=3), and intramyocardial coronary lesion (n=1). Mean number of distal anastomoses was $2.3\pm1.0$. Mean number of lesions treated by PCI was $1.2\pm0.4$. There was no operative or procedure-related mortality. PCI-related complication was periprocedural myocardial infarction in one patient, and complications related to CABG were transient atrial fibrillation (n=5), perioperative myocardial infarction (n=1), and transient renal dysfunction (n=1). Early postoperative coronary angiography $(1.8{pm}1.6days)$ revealed $100\%$ patency rate of grafts (57/57). The stenosis occurred in one patient performed PCI before CABG, which was successfully treated with re-ballooning. During midterm follow-up (mean; $25{\pm}26$ months), 1 patient died of congestive heart failure. All survivors (n=24) accomplished follow-up coronary angiographics, which showed .all grafts (56/57) were patent except one string sign. In-stent restenosis was developed in 2 patients who received bare metal stents. Conclusion: In selected patients, complete revascularization was achieved with low risk by taking the hybrid strategy.

Enhancement of the Working Capacity and Selectivity Factor of Calcium-Exchanged Y Zeolites for Carbon Dioxide Pressure Swing Adsorption (이산화탄소 압력순환흡착을 위한 칼슘 이온교환 Y 제올라이트의 작업용량과 선택계수 향상)

  • Kim, Moon Hyeon
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.41-49
    • /
    • 2018
  • Y zeolites with different extra-framework cations, such as $Na^+$, $N^+$, $Ca^{2+}$, and $Cu^{2+}$, with different charge and ionic radius have been investigated to greatly enhance a working capacity (W) of $CO_2$ adsorption at $25^{\circ}C$ and a $CO_2/CO$ selectivity factor (S). A sample of NaY with a very small amount of 0.012% $Ca^{2+}$ was fully reversible for seven times repeated $CO_2$ adsorption/desorption cycles, thereby forming no surface carbonates unlikely earlier reports. Although at pressures above 4 bar, 2.00% CaY, 1.60% CuY and 1.87% LiY all showed a $CO_2$ adsorption very similar to that measured for NaY, they gave a significant decrease in the adsorption at lower pressures, depending on the metal ion. At 0.5 ~ 2.5 bar, the extent of $CO_2$ adsorption was in the order NaY > 1.60% CuY > 2.00% CaY > 1.87% LiY. All the $Na^+-based$ metals-exchanged zeolites have a FAU (faujasite) framework and a Si/Al value near 2.6; thus, there is no discernible difference in the framework topology, framework chemical compositions, effective aperture size, and channel structure between the zeolite samples. Therefore, the distinctive behavior in the adsorption of $CO_2$ with a character as a weak Lewis acid is associated with the site basicity of the zeolites, and the interaction potentials of the cations. Different trend was shown for a CO adsorption due to weaker quadrupole interactions. Adsorption of $CO_2$ and CO on samples of CaY with 0.012 to 5.23% Ca disclosed a significant dependence on the Ca loading. The $CO_2$ adsorption increased when the cation exists up to ca. 0.05%, while it decreased at higher Ca amounts. However, values for both W and S could greatly increase as the bare zeolite is enriched by $Ca^{2+}$ ions. The 5.23% CaY had $W=2.37mmol\;g^{-1}$ and S = 4.37, and the former value was comparable to a benchmark reported in the literature.

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.