• Title/Summary/Keyword: Bar-Specimen

Search Result 285, Processing Time 0.032 seconds

A Study on the Structural Properties of Composite Beam with Attaching Method of Main Bar of Different Types of Structure. (이질구조부 보주근 정착방법에 따른 혼합구조보의 구조적 특성에 관한 연구)

  • 김상헌;임병호;이승조;박정민;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.121-126
    • /
    • 2000
  • The attaching method of different types of structure and explanation of stress transfer mechanism are at important issue as beam having definitive factor such as the anchorage of RC main bar, the stress transfer of anchorage-end S member, RC member-anchorage, anchorage-end S member in the composite beam of S and RC member. In this study, the structural properties of composite beam according to attaching method of main bar about end RC-middle S beam were investigated in order to use them as fundamental data for the development of composite structure member. Throughout a series of study, it was shown that the proof stress of main bar - flange welding specimen is the highest and there is no difference between the deformation-properties according to attaching method of main bar.

  • PDF

Development of Order Communication System - laboratory application - (처방 전달 시스템의 개발 - 검사 처방 시스템의 개발 -)

  • Kim, Jong-Won;Whang, Yoo-Sung;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.118-120
    • /
    • 1992
  • We have developed and been using laboratory order communication system which is a computerized laboratory request and reception system wi th bar code between inpatient or outpatient and the clinical laboratory in Chungbuk National Unversity Hospital. Work flows are as follows: Tests are requested by the physicians through hospital information system without issuing request forms. Bar code stickers containing demographics of patient and other informations such as sample number, slip code and specimen code are printed and attached to smaple tubes. At the department of clinical pathology, smaples are received through the bar code reader. Area numbers are automatically created and laboratory work numbers are determined. Worklists can be issued by each section of laboratory when needed. Our order communication system alleviates the human labor such as specimen labelling and making worklist and reduces clerical errors that occur from sample collection to laboratory analysis.

  • PDF

An Experimental Study on Longitudinal Shear Capacity of Composite Slab Embedded with Silence Insulator (방음재를 삽입한 합성슬래브의 수평전단성능에 관한 실험적 연구)

  • Lee, Seon-Keun;Lee, Chy-Hyoung;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.64-71
    • /
    • 2018
  • This paper provides the results for experimental study on longitudinal shear performance for new-concept composite slabs embedded with silence insulator. Longitudinal shear capacity tests are used to predict characteristics of composite action between the concrete block, silence insulator and deckplate. A total set of 7 Push-Down specimens are tested to clarify the composite action between the concrete block, silence insulator and deckplate. Parameters in this study are the width of T-type bar, the depth of reinforced bar and the thickness of silence insulator. The results from experimental study on longitudinal shear capacity for new-concept composite slabs applied T-type bar, Reinforced bar and Silence insulator are summarized as follows. In test result, the Longitudinal Shear Capacity of the new concept specimen is 2 times excellent than basic specimen with safety. It is expected that applying the proposed composite slab detail at the actual site will provide a significant safety factor in structural aspect of the existing composite slab, and greatly contribute to the improvement capacities of resisting vibration and sound.

The Behavior between Steel fiber Reinforced Concrete Both Simple and Continuous Beams (강섬유 보강 철근 콘크리트 단순보와 연속보의 거동)

  • 곽계환;김원태;김기순;장화섭
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.167-174
    • /
    • 2003
  • It is absolutely natural to be interested in durability and safety of the structure under shear behavior. To fulfill this desire, a comparison on the shear behavior between steel fiber reinforced concrete both simple and continuous beams is done to use in the field working. Several operations are conducted : First of all, plan for optimal combination is standardized. Second, resistance for shear has been generalized in that it is decided by combination of individual elements. Third, as the fracture of tensile bar leads to destruction of specimen, shear behavior of whole specimen is decided by stress working on tensile bar. It should be generalized for other specimens also. Forth, evidence of the softness of steel fiber reinforced concrete beam by experiment lead to application in the fields. Finally, numeral values of the steel fiber reinforced concrete are analyzed and the result is compared to those of experiments. With these consequences, this study was done for the application to dynamic structures such as bridges and the repair and rehabilitation.

  • PDF

Effect of Geometrical Shape and Cold Work on Deformation of the Hydrogen Absorption Metal with Hydrogen Absorption-Desorption Cycling (수소저장-방출싸이클링에 의한 수소저장금속의 변형거동에 관한 형상 및 가공의 영향)

  • Jeong, Y.G.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.3
    • /
    • pp.207-216
    • /
    • 2003
  • By using the electrochemical method, the relation between the deformation and the geometrical shape, and the effect of cold work on hydrogen absorption-desorption cycling in palladium were investigated, In order to study this problem, four kinds of the Pd specimens used were plates and bars as cold worked and annealed states. As results, it is found that the deformation of thickness direction in the palladium plates increased whereas other lateral directions decreased. But the palladium bars showed the same deformation ratio in all directions because of uniform distribution of the $\beta$ phase. Grains in the plate specimens were greatly deformed after hydrogenation cycling whereas grains in the bar specimens were pulverized. Also, deterioration of the hydrogen absorption rate of the bar specimen was larger than the plate specimen. And the effect of cold work on hydrogen absorption capacity was relatively small.

Effect of Peening on Low Temperature Fatigue Strength Behavior of STABILIZER BAR in Suspension Material (현가장치 STABILIZER BAR의 저온피로강도에 미치는 쇼트피닝의 영향)

  • Jung, Jae-Wook;Park, Keyoung-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.353-358
    • /
    • 2004
  • We got the following characteristics from fatigue crack growth test carried out in the environment of room temperature and low temperature at $25^{circ}C$, $-60^{circ}C$, $-80^{circ}C$, and $-100^{circ}C$ in the range of stress ratio of 0.3 by means of opening mode displacement. And there is a difference between shot peened specimen and unpeened specimen. The purpose of this study is to predict the behavior of fatigue crack propagation as one of fracture mechanics on the compressive residual stress. Fatigue crack growth rate of shot peened metal was lower than that of unpeened metal. The compressive residual stress made an impact on tension and compression of the plasticity deformation in fatigue crack plasticity zone. That is. the constrained force about plasticity deformation was strengthened by resultant stress, which resulted from plasticity deformation and compressive residual stress in the process of fatigue crack propagation.

  • PDF

Partial Discharge Characteristics of Ultra-High Voltage CV Cable Insulators by Electrode Shape (전극형상에 의한 초고압 CV케이블 절연체의 부분방전 특성)

  • Kim Gyun-Sig;Kim Byung-Hyun;Jeong Hyeon-Ki;Cha Kwang-Seok
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.712-717
    • /
    • 2005
  • In this thesis, it is investigated that the effect of the cross linked polyethylene(XLPE) insulator do to breakdown phenomenon by the insertion of the needle and bar electrode into XLPE which is used of electric power cable for the ultra-high voltage. The result of the partial discharge properties in the specimen showed that in case of the insertion of needle or bar electrode into XLPE, the effect of the inner discharge become large when the air void is bigger then the clearance of the electrode of the specimen. The closer the distance between the insulator and needle electrode, it takes less time to the insulation breakdown.

  • PDF

Comparative Study on Seismic Performance of Masonry Wall Strengthened by FRP Sheet or Steel-Bar Truss System (FRP 시트 및 강봉 트러스 시스템으로 보강된 조적벽의 내진성능 비교 연구)

  • Lee, Hye-Ji;Kim, Sanghee;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, the in-plane and out-of-plane seismic performance of the masonry wall strengthened using the steel bar truss system proposed by Hwang et al. (2021a, 2021b) or using FRP sheets were compared and evaluated. The maximum strength of the masonry wall reinforced with FRP sheets for the in-plane and out-of-plane loading was 71% and 85%, respectively, of that of the non-reinforced masonry wall. Meanwhile, the maximum strength of the masonry wall reinforced with the steel bar truss system was approximately 1.8 times higher than that of the non-reinforced masonry wall. Compared with the FRP sheet method, the steel bar truss system was excellent at improving the maximum load capacity, rigidity, and energy dissipation capacity. However, in the case of a masonry wall reinforced with FRP sheets, the masonry wall was overstrengthened with the FRP sheets covering the entire masonry wall, and it is considered that the overstrengthened specimen experienced sliding failure, resulting in a lower strength than the other specimens. A follow-up study is needed to compare the seismic performance of the specimen involving only a part of the masonry wall reinforced with the FRP sheets and the specimen reinforced using the steel bar truss system.

Measurement of Dynamic Fracture Toughness Using Chevron Notched Ceramic Specimen (세브론노치 세라믹시편을 이용한 동적파괴인성측정)

  • Lee, Yeon-Soo;Lee, Young-Sun;Park, Rae-Seok;Moon, Young-Deuk;Yoon, Hi-Seak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.98-104
    • /
    • 2001
  • A dynamic fracture toughness test method with a chevron notched ceramic specimens is proposed. The notch angles of the chevron specimens were 90, 100$^{\circ}$and 110$^{\circ}$. Finite element analysis(FEA) were done to determine the geometrical properties of chevron-notch specimens according to notch angles. The static fracture toughness of the chevron notched alumina specimen was 3.8MP$\alpha$√m similar to that of the general fracture specimen with a precrack. Dynamic fracture toughness was 4.5 MP$\alpha$√m slightly higher than the static one. These research showed the possibility of the split Hopkinson pressure bar test method using the newly proposed chevron notched specimens to get the dynamic fracture toughness of extremely brittle materials such as ceramics.

  • PDF

Pull-Out Bond Properties of Polymer Cement Coated Rebars in HSC (고강도콘크리트에서 폴리머 시멘트 슬러리 도장철근의 인발부착특성)

  • 김민호;김완기;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.215-220
    • /
    • 2002
  • Epoxy-coated re-bar was partly used to the structures and put to practical use, but were not economical and appeared to have defects such as the diminishing of long term bond strength between concrete. The study of polymer cement slurry coated re-bar was started in order to complement the defect of epoxy coated re-bar, and ever since the basic properties appeared to be excellent. But, study of bond properties embedded in concrete specimens was insufficient until now. This study attempts to examine the possibility of improving the bond strength of polymer cement slurry coated re-bar between concrete specimens in accordance with ACI Code and KS Code through pull-out test of 150mm$\times$150mm$\times$150mm substrates with polymer cement slurry coated re-bar having polymer cement ratios of 50%, 75% and 100%, coating thickness 250${\mu}{\textrm}{m}$, 450 ${\mu}{\textrm}{m}$ and with curing ages of 3, 7 and 28 days. High strength concrete was designed having a compressive strength of 500kgf/cm2 as specified. Practical bond length ranges of 55 and 85mm were applied to each of specimen. The bond strength of polymer cement slurry coated re-bar using St/BA-1 and St/BA-2 was compared to that of plain re-bar. The results of this study showed that the bond strength of 55mm bond length was much higher than that of 85mm bond length.

  • PDF