• Title/Summary/Keyword: Bang wall

Search Result 113, Processing Time 0.03 seconds

An Economic Analysis of Steel Framed Modular Housing: Compared with Case of Urban Type Living Housing of Wall-slab (강재 프레임 주택형 모듈러의 경제성 분석: 벽식구조인 도시생활형주택과의 사례비교를 통해)

  • Bang, Jong-Dae;Chun, Chu-Young;Park, Ji-Young;Kim, Jong-Yeob;Kim, Gap-Deug;Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.305-314
    • /
    • 2014
  • The technology-intensive unit modular method of factory production method is attracting attention by the limit of the labor-intensive and field centered wet construction method. In recent years, the unit modular method has been applied to the construction of schoolhouse and BOQ(bachelor offices' quarters), dormitories, etc. But the modular method still is not used in housing construction by the lack of verification of resident performance and construction cost. Therefore, this study analyzed the economics of modular house to vitalize the constructed residential building by modular method and to develop the modular method. According to the study results, the construction cost of the modular house was analysed more about 6.2% expensive than that of the existing housing. However, if the construction duration of modular house is shortened or the productivity of modular house is increased, the construction cost of modular house will be similar to the that of the existing house.

A Study on the Effect of the Stemming Hole medium to the Blasting Separation Distance of Structure (공내 매질이 구조물의 발파이격거리에 미치는 영향에 관한 연구)

  • Kang, Hee-Seop;Jeong, Jung-Gyu;Bang, Myung-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.100-108
    • /
    • 2017
  • Because of urbanization, Industrialization and expansion of transportation network, blasting works are recently increasing in construction field. The blasting work influences environmental effects to residents and the safety of facilities around the working place, so the development of blasting technology is needed to reduce the damage to residents. The blasting mechanism in the hole was studied and tested in the blasting sites by the difference of diameter between explosives and drilling hole, which is named by the decoupling effect. This effect was tested by changing the medium between explosives and hole wall in three working sites(railway, highway and industrial complex). The vibration velocity of blasting was recorded and vibration equations were produced by regression analyses. Finally, the structure separation distance was derived using these equations. The testing results show that the specific gravity of medium is larger, the separation distance is smaller and the duration time of blasting is shorter in case of large specific gravity of medium, so the vibration effect stops more fastly in the water compared with the air.

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.104-104
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.

  • PDF

Identification of a Mature form and Characterization of Thermostability of a Serine-type Protease from Aquifex pyrophilus

  • Kim, Yun-Kyeong;Choi, In-Geol;Nam, Won-Woo;Yu, Yeon-Gyu
    • BMB Reports
    • /
    • v.33 no.6
    • /
    • pp.493-498
    • /
    • 2000
  • Aquifex pyrophilus, a hyperthermophilic bacterium, has a serine-type protease that is located at the cell wall fraction with a mature size of 43 kDa. Molecular cloning of the protease gene revealed that it has an ORF of 619 amino acids with homologous catalytic site of serine-type proteases [Choi, I.-G., Bang, W.-K., Kim, S.-H., Yu, G. Y., J. Biol. Chem. (1999), Vol. 274, pp. 881-888]. Constructs containing different regions of the protease gene, including a alanine-substituted mutant at the active site serine, were constructed, and the factors affecting the expression level of the cloned protease gene in E. coli were examined. The presence of the C-terminus hydrophobic region of the protease hindered over-expression in E. coli. Also, the proteolytic activity of the expressed protein appeared to toxic to E. coli. An inactive form that deleted both of the N-terminal signal sequence and the C-terminal polar residues was over-expressed in a soluble form, purified to homogeneity, and its thermostability examined. The purified protein showed three disulfide bonds and three free sulfhydryl group. The thermal denaturation temperature of the protein was measured around $90^{\circ}C$ using a differential scanning calorimeter and circular dichroism spectrometry. The disulfide bonds were hardly reduced in the presence of reducing agents, suggesting that these disulfide bonds were located inside of the protein surface.

  • PDF

Vector mechanics-based simulation of large deformation behavior in RC shear walls using planar four-node elements

  • Zhang, Hongmei;Shan, Yufei;Duan, Yuanfeng;Yun, Chung Bang;Liu, Song
    • Structural Engineering and Mechanics
    • /
    • v.74 no.1
    • /
    • pp.1-18
    • /
    • 2020
  • For the large deformation of shear walls under vertical and horizontal loads, there are difficulties in obtaining accurate simulation results using the response analysis method, even with fine mesh elements. Furthermore, concrete material nonlinearity, stiffness degradation, concrete cracking and crushing, and steel bar damage may occur during the large deformation of reinforced concrete (RC) shear walls. Matrix operations that are involved in nonlinear analysis using the traditional finite-element method (FEM) may also result in flaws, and may thus lead to serious errors. To solve these problems, a planar four-node element was developed based on vector mechanics. Owing to particle-based formulation along the path element, the method does not require repeated constructions of a global stiffness matrix for the nonlinear behavior of the structure. The nonlinear concrete constitutive model and bilinear steel material model are integrated with the developed element, to ensure that large deformation and damage behavior can be addressed. For verification, simulation analyses were performed to obtain experimental results on an RC shear wall subjected to a monotonically increasing lateral load with a constant vertical load. To appropriately evaluate the parameters, investigations were conducted on the loading speed, meshing dimension, and the damping factor, because vector mechanics is based on the equation of motion. The static problem was then verified to obtain a stable solution by employing a balanced equation of motion. Using the parameters obtained, the simulated pushover response, including the bearing capacity, deformation ability, curvature development, and energy dissipation, were found to be in accordance with the experimental observation. This study demonstrated the potential of the developed planar element for simulating the entire process of large deformation and damage behavior in RC shear walls.

A Study on Syngas Co-Combustion Characteristics in a 0.7 MWth Water-Tube Boiler with Single Heavy Oil Burner (중유 싱글 버너 수관식 보일러에서의 합성가스 혼합연소 특성 연구)

  • Choi, Sin-Yeong;Yang, Dong-Jin;Bang, Byoung-Yeol;Yang, Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.5
    • /
    • pp.452-459
    • /
    • 2010
  • This study is aimed to investigate changes of combustion characteristics and heat efficiency when syngas from gasification process using low-rank fuel such as waste and/or biomass is applied partially to an industrial boiler. An experimental study on syngas co-combustion was performed in a 0.7 MW (1 ton steam/hr) water tube boiler using heavy oil as a main fuel. Three kinds of syngas were used as an alternative fuel: mixture gas of pure carbon monoxide and hydrogen, syngas of low calorific value generated from an air-blown gasification process, and syngas of high calorific value produced from an oxygen-blown gasification process. Effects of co-combustion ratio (0~20%) for each syngas on flue gas composition were investigated through syngas injection through the nozzles installed in the side wall of the boiler and measuring $O_2$, $CO_2$, CO and NOx concentrations in the flue gas. When syngas co-combustion was applied, injected syngas was observed to be burned completely and NOx concentration was decreased because nitrogen-containing-heavy oil was partially replaced by the syngas. However, heat efficiency of the boiler was observed to be decreased due to inert compounds in the syngas and the more significant decrease was found when syngas of lower calorific value was used. However, the decrease of the efficiency was under 10% of the heat replacement by syngas.

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.486-497
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate, A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side has a shape of annulus around vertical tube and the lost heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 11 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348∼3.282kg/hr, of inlet air mass fraction 11.8∼55.0%. The investigation of the flooding is preceded to find the upper limit of the reflux condensation. Onset of flooding is lower than that of Wallis' correlation. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the increase of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed by 165 data of the local heat transfer. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17.7% between the results by the experiment and by the correlation.

  • PDF

Biliary Obstruction Caused by Non-Hodgkin Lymphoma Involvement: A Case Report

  • Jae Hyun Lim;Huapyong Kang;Jung Hyun Jo;Hee Seung Lee;Jeong Youp Park;Seungmin Bang;Seung Woo Park;Si Young Song;Moon Jae Chung
    • Journal of Digestive Cancer Research
    • /
    • v.6 no.1
    • /
    • pp.32-35
    • /
    • 2018
  • Non-Hodgkin's lymphoma is known to be a rare and unusual cause of biliary obstruction. We report a case of biliary obstruction that a 25-year-old male showed icteric sclera and yellow discoloration of his skin caused by metastasis of non-Hodgkin lymphoma. Initial imaging & endoscopic work-up led us to an impression of either cholangiocarcinoma or IgG4-related disease, yet the pathological results weren't diagnostic. Through our thorough re-examination, we found a 5cm sized round, fixed, non-tender sternal mass, and additional imaging studies were suggestive of lymphoma, which was also consistent with the results of incisional chest wall biopsy. Biliary obstruction by lymphoma was successfully treated by endoscopic plastic stent insertion procedure and chemotherapy. Although it is widely accepted that lymphoma accounts for very few portion of malignant biliary obstruction, due to the fact that lymphoma and cholangiocarcinoma are often indistinguishable, careful diagnostic approach should be done.

  • PDF

Radiotherapy in Locoregional Recurrent Breast Carcinoma (국소 재발된 유방암의 방사선치료)

  • Ha Sung Whan;Yang Mi Gyoung;Chung Woong Ki;Park Charn Il;Bang Yung Jue;Kim Noe Kyung;Choe Kuk Jin
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.203-209
    • /
    • 1988
  • Thirty eight women with recurrent breast carcinoma involving chest wall and/or regional lymph nodes after surgery with or without systemic therapy were treated with radiation between 1979 and 1986. Among them, 5 patients were excluded from analysis because of incomplete treatment. The median follow up of survivors was 30 months (randged 1-79 months). Fifteen (45%)patients had their disease confined to the chest wall and eighteen patients had lymph node involvement as some of their locoregional recurrent disease. Within 36 months after the initial treatment, 87% of recurrences manifested themselves. All patients had radiotherapy to at least the site of involvement. In 8 patients, recurrent tumors were treated with complete excision followed by radiation. Of the remaining 25 patients,18 (72%) had complete response (CR) following radiotherapy. The actuarial 3-year survival of all patients following locoregional recurrence was 50% Three year survival was 24% in those 25 patients who had recurrences within 24 months of the initial treatment. For those 8 patients whose recurrences occurred after more than 24 month disease free interval, the 3-year survival was 100%. For those patients with recurrences confined to chest wall alone, 3-year survival was 57% The patients who had lymph node involvement as part of their locoregional recurrences had a 43% 3-year survival. The majority of them developed distant metastases. Those patients who had a CR showed 63% 3-year survival. On the other hand, 1 year survival was only 33% for those patients who had a less than CR. Three patients developed carcinoma of the contralateral breast following radiotherapy. Three year survival following locoregional recurrence was 40% for patients whose initial treatment for their primary breast carcinoma was surgery and adjuvant systemic therapy. For those patients whose primary breast carcinoma was treated by surgery alone, the 3-year survival following locoregional recurrence was 71%. In patients who had subsequent recurrence after radiotherapy, the actuarial survival was 25% at 2 years.

  • PDF

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF