Comminuted fractures of the patella mostly occur at the inferior pole and require appropriate reduction and fixation to restore the extensor mechanism. Conventional methods such as tension-band wiring are not enough to gain proper fixation strength. Numerous methods have been reported, including circumferential cerclage wiring, osteosynthesis, and suture anchors depending on the fracture pattern. Herein, the author reports a relatively rare case of a comminuted fracture of the upper pole of the patella, for which we used augmented Krackow sutures in the quadriceps and fixation with tying of the suture limbs through patellar bone tunnels. Satisfactory results were obtained in terms of reduction and extensor mechanism recovery.
An 8-month-old, 3.5 kg intact female Toy Poodle was presented for non-weight-bearing lameness on left hindlimb. In radiological testing, left proximal tibal type II Salter-Harris physeal fracture and fibular fracture were seen. Following open reduction, the fracture was stabilized with cross-pins, tension band wires, and a hinged transarticular external skeletal fixator (HTAESF). The range of the HTAESF was increased to $25^{\circ}$ at 7 days postsurgery and to $70^{\circ}$ at 14 days post-surgery. The HTAESF was removed 3 weeks after surgery. At 6 weeks post-surgery, the fracture was successfully healed with no complications and the patient recovered a normal gait. Seven months post-surgery, the patient had a normal gait and a normal stifle joint range of motion compared to the contralateral normal limb. This is a case in which the combined use of cross-pins, tension band wires, and HTAESF was successful for treatment of a proximal tibial physeal fracture in a dog. It is thought that these methods are beneficial for stability of fracture site and recover of joint's normal range of motion through early joint movement.
Journal of the Korean Institute of Electrical and Electronic Material Engineers
/
v.18
no.1
/
pp.62-67
/
2005
Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.
Journal of the Korea Academia-Industrial cooperation Society
/
v.22
no.3
/
pp.492-498
/
2021
This feasibility study evaluated an optically transparent planar antenna using liquid salt-water as the conducting material. The most significant reason behind using liquid salt-water for transparent antenna applications is its excellent average optical transparency (OTav) (> 95% at a salinity of 40 ppt) compared to other typical solid transparent thin-film electrodes, such as indium tin oxide (ITO:> 73%) or multi-layer films (MLF: > 78%). Each conductive arm of the proposed dipole is constructed from a salt-water layer held between two clear planar acrylic layers (r = 2.61, tan = 0.01, OTav > 90%) (acrylic/salt-water/acrylic; ASA) due to surface tension. To examine the electrical and optical properties of the ASA structure, the surface tension was measured to determine the thickness of the salt-water layer that finalized its sheet resistance and OTav. The average gain and efficiency of the antenna were 1.72 dBi and 74%, respectively, in the operating UHF (Ultra high frequency) band (470-771 MHz). Therefore, the proposed antenna can be a good candidate for applications as a transparent planar antenna using salt-water.
Proceedings of the Korean Society for Noise and Vibration Engineering Conference
/
2009.10a
/
pp.270-275
/
2009
Sound absorption characteristics of membrane system which are used in stadiums and arenas were investigated. Theoretical studies on acoustic properties of single and double leaf permeable membrane conducted. Also, experimental studies on sound absorption characteristics of combined membrane system that is composed of outer and inner membrane material were conducted. In this study, sound absorption characteristics of each membrane were investigated by experiments in reverberation chamber. 4 types of permeable membranes and a non-permeable membrane were used for experiments. Air space behind membrane material and tension on the membrane was varied. Sound absorption performance of permeable membrane materials was confirmed. As increasing air space behind the membrane material, sound absorption coefficient was increased. In a resonance absorption frequency band sound absorption coefficient varied more dramatically. Sound absorption characteristics were flat in mid and high frequency range and sound absorption coefficient was from 0,3 to 0,5. Also sound absorption coefficient was increased by the increment of surface density and air permeability of membrane. However, over the certain value of air permeability, sound absorption coefficient was decreased. These results can be used as design factors and method for the room acoustic design of dome-stadiums and large free-form buildings.
The purpose of this study was to examine the effects of Task-oriented training on the balance, lapse time and MVC(Maximum Voluntary Contraction) of CVA(cerebral vascular accident) patients. The active balance equipment was used to measure of the static balance, lapse time and task-oriented training. The EMG technique was used to record muscle activitie of affected side of gluteus medius and vastus medialis. The raw EMG data were filtered with band pass filter (60Hz) to remove artifacts and then low pass filtered (20Hz) to find the linear envelope which resemble muscle tension curve. The experiment had been conducted at the department of physical therapy in J hospital in M city during 8weeks. The thirty patients experienced the stroke were participated: training group (15), control group (15). They were ambulatory with or without an assistive device. They were assessed on central perturbation(mm) in the static balance, lapse time(s) and MVC test(mV). The data were analyzed using repeated measured ANOVA. The results were as follows: After Task-oriented training, central perturbation and lapse time was significantly differences in both groups(p<.001), and MVC in gluteus medius were no significant differences in both groups, but vastus medialis was significant differences in both groups (p<.001).
Park, Woo-Yeol;Jang, Ho-Su;Kim, Jung-Ho;Park, Dong-Sam
Journal of the Korean Society of Manufacturing Technology Engineers
/
v.21
no.4
/
pp.613-618
/
2012
The Ultrasonic metal welding is used in the solid-phase welding method at room temperature or low temperature state. In welding process, the high frequency vibration energy is delivered to the welding part under the constant pressure for welding. In this study, we aimed to design and manufacture a 40,000 Hz band horn through finite element analysis. By performing modal analysis and harmonic response analysis, the modal analysis result is that the horn frequency was 39,599Hz and the harmonic response result that the horn frequency was 39,533Hz. These results were similar. In order to observe the designed horn's performance, about 4,000 voltage data was obtained from a light sensor and was analyzed by FFT analysis using Origin Tool. The result RMS amplitude was approximately $8.5{\mu}m$ at 40,000Hz, and maximum amplitude was $12.3{\mu}m$. Using this manufactured horn along with an ultrasonic metal welder and tension tester, the weldability of Cu sheets was evaluated. The maximum tensile force was 66.53 N in the welding condition of 2.0 bar pressure, 60% amplitude, and 0.32 s welding time. In excessive welding conditions, it was revealed that weldability is influenced negatively.
A number of dynamic stabilization systems have been used to overcome the problems associated with spinal fusion with rigid fixation recently and the demand for an ideal dynamic stabilization system is greater for younger patients with multisegment disc degeneration. Nitinol, a shape memory alloy of nickel and titanium, is flexible at low temperatures and regains its original shape when heated, and the Nitinol shape memory loop (SML) implant has been used as a posterior tension band mostly in decompressive laminectomy cases because the Nitinol implant has various characteristics such as high elasticity and a tensile force, flexibility, and biological compatibility. The reported short-term outcomes of the application of SMLs as posterior column supporters in cervical and lumbar decompressive laminectomies seem to be positive, and complications are minimal except for the rare occurrence of pullout and fracture of the SML. However, there was no report of neurological complications related to neural compression in spite of the use of the loop of SML in the epidural space. The authors report a case of delayed development of radiating pain caused by subsidence of the SML resulting epidural compression.
Kim, Jae-Hwa;Lee, Soon-Chul;Cho, Duck-Yun;Yoon, Hyung-Ku;Lee, Yoon-Seok
Clinics in Shoulder and Elbow
/
v.9
no.1
/
pp.124-129
/
2006
Distal clavicular fracture frequently requires operative treatment due to high rate of non-union. The operative technique includes the tension band wiring, K- wire fixation, and cerclage wiring etc. Each method has disadvantages somewhat like pin migration or acromioclavicular joint injury and so on. For the distal clavicular fracture type 2a, because of its oblique fracture line, the cerclage wiring is suitable. We performed the cerclage wiring percutaneously under minimal incision without injury to periosteum for the patient who had the distal clavicular fracture type 2a, and the result was favorable.
Since the olecranon fractures are caused by relatively low-energy injuries, such as a fall from standing height, they are usually found without comminution. Less commonly they can be developed by high-energy injuries and have severe concomitant comminution or injuries to surrounding structures of the elbow. Because the fracture by nature is intra-articular with the exception of some avulsion-type fracture, a majority of olecranon fractures are usually indicated for surgical treatment. Even if there is minimal displacement, surgical treatment is recommended because there is a possibility of further displacement by the traction force of triceps tendon. The most common type of olecranon fracture is displaced, simple non-comminuted fracture (that is, Mayo type IIA fractures). Although tension band wiring was the most widespread treatment method for these fractures previously, there is some trends toward fixation using locking plates. Primary goal of the surgery is to restore a congruent joint and extensor mechanisms by accurate reduction and stable fixation so that range of motion exercises can be performed. The literature has shown that good clinical outcomes are achieved irrespective of surgical fixation technique. However, since the soft tissue envelope around the elbow is poor and the implants are located at the subcutaneous layer, implant irritation is still the most common complication associated with surgical treatment.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.