• Title/Summary/Keyword: Ballast Water Treatment System

Search Result 66, Processing Time 0.022 seconds

Filtering System Design and Structural Analysis for Intake Water of Ship's Ballast Tank (선박 밸러스트 탱크 유입수 필터링 시스템 설계 및 구조해석)

  • Yun, Sang-Kook;Park, Byung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.282-287
    • /
    • 2009
  • As current international guideline and IMO regulation give severe restrictions for ships to manage ballast water to reduce unintentional organism transfers, several ballast water treatment systems recently have been being developed together with filtration. That is because discharging ballast water from ships causes many pollutions by foreign biological invasive species. The primary treatment system being considered in this study was based on fine screen filtration technology applied to ballast water filter in ballast tank in order to reduce the load of ballast water treatment system. New ballast water filtration system was invented and analysed. The structural stress and strain analysis for ballast filtration systems which are current and invented filters were carried out using UGS and Ansys. The results showed that the structure of current filtering module was not designed to meet the requirement of sea water filtration during ballasting operation. The studies also showed that the invented design of filtration system equipped with back washing and automatic scrapper for eliminating cake of bio-species might be a potentially effective technology for ballast water management of ship's ballast tank.

A Study of the Technical Treatment within an Environmental Appetency for the Ballast Water

  • Nam, Chung-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1313-1323
    • /
    • 2004
  • In accordance with adoption of new convention for the control of ship's ballast water at the diplomatic conference held in London Feb, 2004, every country has to regulate the ballast water and deposit matters. When this Resolution comes into effect in 2009, all vessels engaged in international voyage must have ballast water control program, ballast water records, equipments which are suitable to the standard of exchange and performance for the ballast water. This study estimates objectively their performances, merits and demerits of the ballast water treatment technique and exchanging techniques for safe operation of ships. It is desirable to design an equipment to control the ballast water using the brush-type vacuum suction nonstop reverse cleaning system to overcome the clogging phenomenon and the direct disc filtering to maximize filtering area for the optimum process considering biological availabilities. It will be expected to protect against marine pollution and to maintain clean sea if it is secured to develop new ballast water treatment techniques. And it will also be expected to cope with the Resolution and each regulation of the developed countries from the ballast water.

Shipboard Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Kim, Ki-Wook;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.391-398
    • /
    • 2010
  • This study is currently giving priority to developing the ballast water treatment system using ozone(Ozone BWTS). The Ozone BWTS, were equipped on the real merchant vessel named as M. V. Hyundai Hong Kong to carried out shipboard tests of ballast water treatment system in accordance with orders of IMO G8 Guidelines. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-.2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

Life-Cycle Cost Analysis of Ballast Water Treatment System (LCC 분석에 의한 Ballast Water 처리 시스템의 경제성 평가)

  • Kim, Je-Eun;Kim, Soo-Young;Kim, Hyung-Man;Seo, Guan-Hui
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.673-678
    • /
    • 2005
  • IMO adopted ' International Convention for The Control and Management of Ships' Ballast Water and Sediments ' on February 13th 2004. According to this convention, a ballast water treatment system should be installed in all ships obligatorily up to a standard date. When the system is installed, economic propriety should be considered. The economic propriety analysis examines the profit of a relevant project which can be presented by a equation, (Profit) = (income) - (expense) - (tax). However, the ballast water system is not for the profit during the life cycle but for the satisfaction of the regulation. Therefore, the expense should be minimum against the profit. This study presents the LCC(Life-Cycle Cost) analysis for economic evaluation of several ballast water system of foreign products.

Land Based Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Yoon, Seung-Je;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.383-390
    • /
    • 2010
  • This study is currently giving priority to developing the ship's ballast water treatment system using ozone (Ozone BWTS). The Ozone BWTS was tested in a full scale land-based mobile barge to evaluate performance according to the IMO G8 Guidelines. Test cycles using the mobile-barge were conducted in seawater and brackish water in the vicinity of the Port of Busan and Nakdong River, Republic of Korea. All tests were conducted according to the requirements of the G8 Guidelines. Test results show that the Ozone BWTS meets the Ballast Water Performance Standard contained in Regulation D-2 of the IMO Ballast Water Management Convention, as well as all of the operational, safety, and environmental testing requirements of the G8 Guidelines, as required for type approval of IMO. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

Development of the Electrolysis Ballast Water Treatment System and Test (직접 전기분해식 선박평형수 처리장치 개발과 시험에 관한 연구)

  • Bag, Og-Yeol;Moon, Jang;Park, Jun-Mo;Kong, Gil-Young
    • Journal of Navigation and Port Research
    • /
    • v.41 no.3
    • /
    • pp.79-86
    • /
    • 2017
  • Ballast water filled into and discharged from the ballast tank of a ship has a negative impact on local marine environment due to various aquatic organisms contained therein. The IMO developed and adopted "The International Convention for the Control and Management of Ships Ballast Water and Sediments, 2004" with the purpose of protecting the marine environment from transfer of harmful aquatic organisms in ballast water carried by ships. The IMO BWM Convention was approved in September 2016 and ships must be equipped with ballast water management system after September 2017. Ships' ballast water treatment methods are divided into using active substances as electrolytic type, ozone type, chemical dosing type and using physical treatment type as filter type, ultraviolet type. It is also used with a combination of two methods. Electrolysis is superior in terms of cost and efficiency. In this study, basic principles, components, and land base test contents of electrolysis ballast water treatment system, a direct electrolyzed ballast water treatment system, were examined. Land base test was conducted with 300m3/h capacity device at the KIOST Geoje plant where the government test facility was installed. This test validated that the system meets IMO standards.

Design and Fabrication of Ballast Water Treatment System using Fuzzy PID Controller (퍼지 PID 제어 기법을 이용한 선박평형수 처리 시스템 설계 및 제작)

  • Lee, Young-Dong;Ahn, Byeong-Gu;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.3
    • /
    • pp.108-114
    • /
    • 2015
  • Ballast water is carried by ships to ensure stability, trim and structural integrity. When a ship loads cargo, the ballast water is discharged. When foreign marine microorganisms are introduced into new marine environments, they pose a threat to the local marine ecological system. UV system is commonly used for the disinfection of waste and surface water. This method would not be as efficient because some species do survive to form viable populations, much of the sediment and organisms at the bottom of tanks, and may become serious pests. In this paper, we designed and implemented ballast water treatment system using fuzzy PID controller to prevent lamp damage, and to reduce the formation of the viable populations. The experiments were conducted with ballast water treatment system using fuzzy PID controller with short time exposure to the temperature above $40^{\circ}C$. This system was shown to be effective by significantly reducing bacterial population and lamp life extension through appropriate temperature of ballast water.

A study on the strategy of concerned parties with regard to the performance standards and implementation schedule of ballast water treatment systems (평형수처리장치 성능기준 및 시행시기 차이에 의한 관련 당사자들의 대응전략 연구)

  • Kim, Kyong-Min;Kim, Hoi-Jun;Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.325-332
    • /
    • 2014
  • In installing ballast water treatment system, the cost of the system is high and many technical aspects are to be considered and also it takes significant time to retro-fitting on the existing ships. In addition, in the current circumstance which the Ballast Water Management Convention has not been entered into force, the 28th IMO Assembly adopted a resolution to mediate the implementation schedule of the treatment systems. In the mean time, California State and New York State have declared more stringent discharge requirements of ballast water and are planning to implement them earlier than the schedule of the Convention. In these circumstances, the implication in the difference between ballast water treatment system manufacturers and ship owners need to be considered. In this study, through the review on the considerations when installing the system onboard, stringent requirements of United States of America, and determent or mediated implementation schedules of Convention and California and New York States, the author would like to suggest the strategy of concerned parties for anticipated entrry into force of the Convention and implementation of the stringent requirements of United States of America.

A study of Ballast water Treatment using a Disk filter (디스크 여과장치를 이용한 선박 밸러스트수 전처리 연구)

  • Park, Sang-Ho;Lim, Jae-Dong;Park, Sun-Jung;Kim, Dong-Geun;Kim, In-Soo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.149-150
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic back washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop oft the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 2.6bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF